Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹29.0 L+₹99,960.26 (3.57%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹30.4 L+₹2.5 L (8.84%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹31.7 L+₹3.7 L (13.3%)Rejected-Finance GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹32.5 L+₹4.5 L (16.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA PIN 184121
COMPREHENSIVE MAINT IN MD ACCN THROUGH IVRS BASED COMPLAINT RECTIFICATION UNDER GE SAMBA BR AND EM
2025_MES_701034_1
GE/SMB/T-76/2024-25
Open Tender
Miscellaneous Works
Item Rate
334 days
GE SAMBA
CLASS D a (i) b (i)
8 documents required · 8 mandatory
₹500
GE SAMBA
₹60,000
Yes
2 Jul 2025
11 Mar 2025
3 Apr 2025
11 Mar 2025
1 Apr 2025
25 Mar 2025
Amount
Resecuring or easing and adjusting without taking down of shutter Area exceeding 1.00 sqm but not exceeding 2.00 sqm each of complete all as specified and directed
M&L for taking down shutter and refixing in same opening after easing same shutter area exc 1 Sqm but n exc 2 Sqm each of complete all as specified and directed
S&F in repair 150mm ordinary rat rail, rod pattern mild steel springs ISI marked including roller and roller plate complete including all necessary welding if required complete all as specified and directed.
Taking down shutters of any description exc 1Sqm but n exc 2Sqm each.
S & F Magnetic door catches with sticking plate of standard size for cupboard doors approved by GE
M&L non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick in CM 1:6 incl Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, complete all as specified and directed.
M&L Glazed ceramic coloured tiles of size 450 x 350 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4, incl Dismantling of wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, all as specified and directed.
M&L vitrified ceramic joint free tiles 8-9 mm thick ( sq/ rect) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6incl Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises complete all as specified and directed.
M&L 75mm thick plain cement concret type C-2 1:3:6 (using 20mm graded crushed stone aggregate) as in flooring/Sub base/Plinth protection all as spd and directed.
S&F in repairs 300mm long Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S&F in repair butt hinges 100mm, cold rolled medium weight mild steel all as specified.
S&F in repair 125mm size, extruded aluminium alloy handles, fabricated type, anodised.
S&F in repair 150mm long aluminium tower bolts (ISI Marked) extruded type all as specified.
S&F 100mm Hasp and staple, safety type, aluminum anodised including bolt to hinge plate and fixed with screws complete
S&F Continuous (Piano) hinges, mild steel , bright finish or electrogalvanised with wide of flaps 30mm in repairs all as specified and directed.
M&L for Taking down cement plaster on brick or concrete surface and description including raking out joints hacking for key scrubbing down with water,
M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement mixed with including scaffolding at any height complete all as specified and directed by Engineer-in-charge.
M&L Rendering 10mm thick in cement mortar 1:6 on fair aces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L two coats of cement base paint over a coat of primer on newly plastered surface of wall including preparation of surface and curing after applying each coat complete all as specified and directed.
M&L one coat of cement base paint on wall including preparation of surface complete all as specified & directed by Engr-in-Charge.
M&L Complete removal of existing treatment from internal surfaces of walls by wire brushing and washing, rubbing down and stopping of surfaces , applying 1mm wall care putty on walls and make the surface of level, clean and repair disturbed edgs of bricks/concrete walls finish to even and smooth and applying two coat of oil bound distemper over a coat of primer all as spd and directed by Engr-in-Charge.
Supply and fixing Rotational moulded polyethylene water storage tanks of 500 litres capacity,(cylindrical vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified.
Supply and fixing Rotational moulded polyethylene water storage tanks of 1000 litres capacity,(cylindrical vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified.
M&L 20mm Gun metal globe or gate walve with iron wheeled head, screwed both ends for iron and fixed in repairs.
Disconnecting existing tanks, exc 250 ltr n exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified & directed
Disconnecting existing tanks, exc 500 ltr n exc 1000 ltr setting aside (orlowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified & directed
S&F in repair vitreous china wash down water closet pan (Orissa patern) white with integral foot rest of of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 'P' and 'S' trap complete incl making good to floor complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan and trap, (pedestal pattern) including fixing bolts and connecting to drain pipe, including white seat cover plastic flat bottom and MS Chromium plated hinging device and connection to flush pipe, anti symphonic pipe etc complete all as specified and directed and including 'P' and 'S' trap complete incl making good to floor complete all as specified and directed.
S&F in reapairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F 100mm m cast iron sanitary connection ‘S’ /'P' trap, with branch 370 to 450mm long excluding joint
S&F low level 10 ltrs capacity PVC valveless symphonic action type flusing cistern low level white with inlet ball valve float ovel handle including 32mm dia PVC flushing pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washer and waste including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overallsize 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
S&F in repairs S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm
S&F in repair bib taps long body, fancy type, chromium plated, cast copper aloy ISI marked with crutch or butter fly handle high pressure screwed down for iron pipe of 15mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair fancy type Pillar tap cast copper alloy chromium plated with capstan heads screwed down high pressure or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed.
S&F in repairs 15mm bore angle valve chromium plated screwed down fancy type high pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repair centre hole basin mixture valve, cast copper alloy fancy type 15mm brass chromium plated mixer (central hole basin mixer w/o pop up waste system) for mixing hot & cold water screwed down for iron pipe , complete all as specified.
S&F in repair steel curtain rods 25mm dia factory fixed all as directed and as approved by Engr in Charge.
S&F in repair bracket prepainted with screw, hole suitable for 25mm dia rod fixed with screws and gutties in wall.
All as per above here-in-before, but end caps with wall ornament and fixed to curtain rod with screws of design/shape all as specified and directed.
S&F in Galvanised mild steel wire cloth 0.46mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples/ wooden beding complete all as specified and directed.
S&F in repair PVC cabinate mirror of size 300x450mm fixed with screw and PVC gutty on wall complete all as specified and directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc. 0.50 Sqm in each pane all as specified.
S & F 3mm thick figured Sheet glass pin headed type and glazing with oil putty and pins in square n exc 0.5 sq. m in each pane on complete all as specified and directed.
Hacking out old brocken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounds, gazed with putty or fixed with beads.
S&F GI tube 15mm bore medium grade galvanised ISI marked with all fittings incl taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, complete on walls complete all as specified and directed.
S&F GI tube 20mm bore medium grade galvanised with all fittings and fixed to short length incl Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, complete all as specified and directed.
S&F, Stainless steel Plate rack 775X750X 0.6mm thick, complete all as specified and directed.
M&L for Sheet glass 5.5 mm thick heat absorbing/solar control film/ tinted and glazing with oil putty/aluminium bedding in square n exc 0.5 sq. m in each pane
S & F in repairs for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed.
Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
S&F in repair 20mm ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified.
S&F in repairs SS Tubular towel rail of chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete.
S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair chromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed."
S&Fin repairs soap dish dish type of milld steel Chromium plated and wooden/plastic cleats , complete all as specified and as directed.
S&F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
S&F for Sheet glass shelf assembly consisting of 5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 50cm long
S&F for Corner glass shelf assembly consisting of 5mm thick sheet glass shelf 30cm wide with chromium plated bracket guard and railing.
S&F in repairs concealed type 15mm bore angle valve chromium plated screwed down fancy type high pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore ,PVC (SWR) 'P' trap as in repair complete all as specified and directed.
S&F for 75mm bore ,PVC (SWR) 'floor' trap as in repair complete all as specified and directed.
S&F for PVC waste pipe 32mm dia, 60 cm long for WHB with cup, fixed in repairs complete.
S&F grating round 100 mm size of stain less steel as in repair, complete all as specified and directed.
S&F in repair Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 45gms/40mm 60 gms complete all as specified and directed
Material & labour for applying one coat of synthetic enamel paint on old wooden surface on any description not otherwise described over 10cm width or girth including preparation of old painted surfaces all as specified and directed by Engineer-in-Charge.
All as per above here-in-before, but one coat of synthetic enamel paint on old steel surfaces all as specified and directed.
S&F in repairs brass spindal for bib tap/ pillar tap etc all as specified and directed by Engineer-in-Charge.
S&F PVC long bend for flushing cistern all as specified and directed by Engineer-in-Charge.
S&F in repairs satinless steel cloth hanger all as specified and directed by Engineer-in-Charge.
S&F in repairs satinless steel coupling of any size for sink all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and PVC rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls except pipes complete all as specified and directed
S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls except pipes complete all as specified and directed
S&F PVC (SWR) 110mm bore bends any radius
S&F PVC (SWR) 110mm bore bends any radius with access door
S&F PVC (SWR) 110mm bore branch piece, single (single Y) equal or unequal
S&F PVC (SWR) 75mm bore vent cowl complete all as specified and directed
Supply and fixing in repairs Cast iron 50 mm dia internal bore, sand cast, soil, waste and went pipes, in any length with or without ears with cement joints, fixed to wall complete all as specified and directed.
Supply and fixing in repairs Cast iron 75 mm dia internal bore, sand cast, soil, waste and went pipes, in any length with or without ears with cement joints, fixed to wall complete all as specified and directed.
Supply and fixing in repairs Cast iron 100 mm dia internal bore, sand cast, soil, waste and went pipes, in any length with or without ears with cement joints, fixed to wall complete all as specified and directed.
S&F Cast iron cowls, sutable to fix in 50 mm dia pipe complete all as specified and as directed.
S&F cast iron Bends, 75mm bore, diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F cast iron branch pieces, single /double Tee 75mm bore (equal or unequal ) , ordinary or inverted (Spigot or socket type) or parallel branches etc complete all as specified and as directed.
S&F cast iron Bends, 100 mm bore, diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F cast iron 100 mm bore, Branch pieces, single Tee (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches , including oval access door complete all as specified and directed.
Taking down soil/waste/vent pipes of any description, size 50/75/100 mm bore incl all fittings, bends etc., all as specified and directed.
Supply and fixing CI oval door access for 100 mm bore pipe fitting including necessary drilling, nut & bolt and provision of rubber washers to make the joint water tight, fixed in repair up to 4th floor complete all as specified and as directed by Engr-in-charge.
Supply and fixing CI oval door access for 75 mm bore pipe fitting including necessary drilling, nut & bolt and provision of rubber washers to make the joint water tight, fixed in repair up to 4th floor complete all as directed by Engr-in-charge.
S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F factory made 18 mm (+0.7mm) thick HDHMR Board manufacured by an ISO 9001-2008 certified company. HDHMR Board for Shelf/Partitions/Drawer , One side lemination and other side balancing white lamination and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete as per manufacturer's specifications and drawing and as directed.
Prelaminated MDF board 19 mm thick as in shutters/shelves (exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame worknincluding lipping (15 mm thick three sides and 20 mm thick lipping hinge side) around the shutter complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) ground floor to second floors and pavings n exc 15 cm thickness (below or above ground level ) and removing the rubbish from the work site out side defence premises complete all as specified.
Rendering 15mm thck in CM 1:3 or Plain Cement Concrete as in sunken floors without extra cement on walls/floors and including mixing of water proofing compound (WPC shall be measured and paid separately)
Cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or euqivalent make of approved by GE cold applied.Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equavalent make as approved by GE, created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm. Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller. Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note : Application of water proofing treatment will be done by authorised applicator only.
M&L Cement concrete type E-2, 1:5:10 ( 40 mm graded agregate) in Sunkan filling and mass concrete complete all as specified and directed by Emgr-in-charge.
M&L 40 mm dia G I tubing heavy grade galvanised laid over floors as a spout pipe in sunken floors all as specified.
Supply only Water proofing compound liquid.
M&L for point wiring in repair for light/fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed boxes, including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as speicified. Note: Colour coding is to be maintained (Ph-Red, N-Black, Half-Yellow, Earth-Green).
All as per items no. 1 here-in-before but for call Bell point complete all as specified and directed.
All as per items no. 1 here-in-before but for one 5 pin 5 Amps socket outlet independent board complete all as specified and directed.
All as per items no. 1 here-in-before but for one 3 pin 5 Amps socket outlet on same board complete all as specified and directed.
M&L for point wiring in repair for light/fan controlled by one switch with 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 4 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed boxes, including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as speicified. Note: Colour coding is to be maintained (Ph-Red, N-Black, Half-Yellow, Earth-Green).
S & F in replacement of switch piano flush type one way 5 Amps SP 240 Volts complete all as specified and directed.
S & F in replacement of switch piano flush type one way 15 Amps SP 240 Volts complete all as specified and directed.
S & F in replacement of socket outlet 2 in 1, 3 pin 5 amps flush type 240 Volts complete all as specified and directed.
S & F in replacement of socket outlet 2 in 1, 5 pin 5 and 15 amps flush type 240 Volts complete all as specified and directed.
S & F in replacement of switch bell push, flush type, 5 amp one way complete all as specified and directed.
S & F in replacement of bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified.
S & F in replacement of old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed
S & F in replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type with pvc box all as specified and directed.
S & F in replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 15 Amp flush type with pvc box all as specified and directed.
Supply & fixing in replacement of old unserviceable capacitor 2.5 mfd ISI marked complete all as spd.
All as per Srl item No 3 above but 3.15mfd complete all as spd.
S & F in replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
S & F in replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting all as directed.
S & F in replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
S & F in replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
S & F in replacement of existing old u/s tube light fitting with batten type 18/20 watt energy efficient tube light fittings LED complete with minimum 3.5/4 feet long with all accessories prewired and making connection with copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and as directed.
S & F in replacement of LED Bulk head light fitting 1 X 9/10 watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
S & F in replacement of existing old u/s tube light fitting with batten type 10 watt energy efficient tube light fittings LED complete with minimum 2 feet long with all accessories prewired and making connection with copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and as directed.
S & F in replacement of LED lamp 7 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
S & F in replacement of LED lamp 15 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
S & F in replacement of LED lamp 12 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
S & F in replacement of sheet metal enclosure 4 way , with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge
S & F in replacement of sheet metal enclosure 8 way, with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge
S & F in replacement of sheet metal enclosure 12 way, with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge
Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN ,240 volts, 32 amps, with rupturing capacity 10 KA, complete all as spd and directed by Engr-in-chrage.
Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN ,240 volts 40 amps, with rupturing capacity 10 KA, complete all as spd and directed by Engr-in-chrage.
Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN ,240 volts any rating from 63 amps, with rupturing capacity 10 KA, complete all as spd and directed by Engr-in-chrage.
Supply and fix in replacement of existing old u/s MCB TPN with 63 amp MCB TPN ,415 volts breaking capacity 10 KA, complete all as spd and directed by Engr-in-chrage.
Supply and fix in replacement of existing old u/s MCB TPN with 40 amp MCB TPN ,415 volts breaking capacity 10 KA, complete all as spd and directed by Engr-in-chrage.
Supply and fix in replacement of existing old u/s MCB TPN with 32 amp MCB TPN ,415 volts breaking capacity 10 KA, complete all as spd and directed by Engr-in-chrage.
S & F VTPN DBs Double Door 4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed
M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
Supply and fix in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Supply and fix in replacement MCB single pole 240 volts any rating 40 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Supply & fixing in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed by Engr-in-charge
S & F High performance IP66 LED Streetlight 35 watt, housing made of die-cast aluminium, with street optic lens,with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5 sqmm from ceiling rose, and 35W LED light etc. drawn through and including 32mm bore GI light grade protecion pipe upto 1.5 m length with suitable fixing accessories on walls, complete all as specified and as directedcomplete all as specified and as directed.
S & F in replacement Gang Box for 15 Amp Switch socket combined including 15 Amp combination complete all as specified and directed.
S & F in replacement Gang Box for 5 Amp Switch socket combined including 5 Amp combination complete all as specified and directed.
S & F for providing/cutting the round/square hole of required size in wall finishing the disturbed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilation fans single phase, 230 volts, 225/230 mm or 9" H.D EX Fan (900 RPM) complete and supply and grounting the ragged bolts in wall, fixing the frame on the exhaut side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 Sqmm copper cable from ceiling rose to exhaust fan motor and MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed.
Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account. (ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. Rate quoated above items No.01 to 107 here in before inclusive provision as under : Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Infrastructure required in Complaint cell i.e. computer, telephone, furniture, stationary, transport and other necessary items/materials to establish a new complaint centre able to receive and manage complaints from the users by all means ie Manual complaint mechanism, Telephonic complaints mechanism, SMS complaint Mechanism and e-mail complaint mechanism through automation tools/application i.e Service Request Tracking and Response System (STARS) developed by VYNUS SOLUTIONS and to maintain a consolidated list of complaints and its redressal mode indicating all its relevant data. (b) Computer data operator shall be able to manage all the necessary activities and having qualification as Graduate in any discipline with minimum one year certificate course of computer applications (from a Govt recognized institute), (c ) Provision and maintenance of all tools, plants, equipment and safely gear required for tradesmen under this contract (d) Provision of communication facilities to supervisor and tradesmen. (e) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (f) Updating status of lodged complaints before change of eight hour shift. (g) Provision of motorized conveyance for deployment to all tradesmen under this contract. (h) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone
(j) On lodging the complaint, the Complaint No. will be assigned for reference . Also system should indicate an approximate time for repairs. Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen. (k) On both copies of complaint slip, status of the complaint attended shall be endorsed by the complaint/user. One copy to be retained by the complainant and second copy to be with tradesmen for handing over in the complaint centre. Reasons for non attending of complaint etc shall be recorded alongwith estimate of expected time to attend and rectifying the complaint. (l) At the end of each day, summary of complaints shall be prepared and generated indicating No of complaints lodged, attended in time, Reasons for not attending , probable time required for attending the pending complaints etc . (m) Timing of complaints will be 9:00 AM to 6:00 PM including sundays and holidays. (n) JE in charge of MES will review the complaints recorded in the system daily and will carry out personal inspection of complaints attended and its status and will take remedial measures in this regard. (o) AGE will visit the complaint cell at least thrice a week and GE at least once a weak to check the efficacy of the system and record their remarks accordingly. Note : Contractor shall be responsible for followings :- (i) Installation of landline telephone connection with internet broadband facility, obtaining SIM cards for mobile phones for supervisor and workers, deployed by the contractor. (ii) Implementation of Bio-metric system for attendance of supervisors and workers, deployed by the contractor. (iiii) Payment of telephone bills, internet charges, mobile bills, expenses etc shall be borne by the contractor and no claim whatsoever on this account will be admissible by the department.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 97,460.00 and any other reduction if any from quoted amount.
M/S RAJESH SHARMA & CO. (BID ID -3274894)
M/s Swastik Engineers (BID ID -3271867)
AAR KAY BEE ENTERPRISES (BID ID -3274999)
Ms Narinder Kumar Sehgal (BID ID -3274814)
M/S BAWA TRADING CO (BID ID -3274377)
VISHNU DUTT AGANIHOTRI & SONS (BID ID -3274101)
M/S RUDHRAKSH TRADING CO (BID ID -3274164)
M/S SINGHAL ENGINEERS (BID ID -3274122)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .