Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAdmitted-Finance | ₹3.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.0 Cr+₹20.3 L (5.39%)Admitted-Finance BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹4.0 Cr+₹20.3 L (5.39%) | L2 | Admitted-Finance |
| 3 | L3₹4.1 Cr+₹37.2 L (9.87%)Admitted-Finance | ₹4.1 Cr+₹37.2 L (9.87%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAJESH N D L1 | Bankers Construction L2 | DIMEBAG SOLUTIONS PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00Roof truss and sheeting | ||||||
| 1.01 | 2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil | 1,800 | sqm | 28.68 ₹51,624 Lowest | 28.68 ₹51,624 Lowest | 58.68 ₹1,05,624 |
| 1.02 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 794.13 | cum | 296.94 ₹2,35,808.37 Lowest | 296.94 ₹2,35,808.37 Lowest | 326.94 ₹2,59,632.21 |
| 1.03 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 516.18 | cum | 258.57 ₹1,33,469.96 Lowest | 258.57 ₹1,33,469.96 Lowest | 298.57 ₹1,54,117.36 |
| 1.04 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 537.96 | cum | 106.37 ₹57,222.49 Lowest | 106.37 ₹57,222.49 Lowest | 216.37 ₹1,16,397.76 |
| 1.05 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 18.78 | cum | 6,814.89 ₹1,27,970 Lowest | 6,814.89 ₹1,27,970 Lowest | 6,814.89 ₹1,27,970 Lowest |
| 1.06 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 132.31 | sqm | 335.31 ₹44,365.54 Lowest | 335.31 ₹44,365.54 Lowest | 335.31 ₹44,365.54 Lowest |
| 1.07 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 244.17 | sqm | 863.64 ₹2,10,872.39 Lowest | 863.64 ₹2,10,872.39 Lowest | 863.64 ₹2,10,872.39 Lowest |
| 1.08 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 10,381.4 | kilogram | 98.3 ₹10,20,491.82 Lowest | 188.3 ₹19,54,818 | 188.3 ₹19,54,818 |
| 1.09 | 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | 18,234.81 | kg | 98.3 ₹17,92,481.82 Lowest | 158.3 ₹28,86,570.42 | 188.3 ₹34,33,614.72 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
15 Feb 2023, 6:00 pmClosed
Manager Projects
KEL Kochi
CONSTRUCTION OF MAGIC SHELL AT KINFRA PARK, THIRUVANANTHAPURAM
2023_KEL_556397_1
KRO/ BDC/1325/2023
Open Tender
Civil Works - Others
Item Rate
360 days
KEL Kochi
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,850
₹1 L
Yes
17 Feb 2023
7 Feb 2023
17 Feb 2023
7 Feb 2023
15 Feb 2023
7 Feb 2023
7 Feb 2023 - 15 Feb 2023
Amount
Roof truss and sheeting
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
od354406/2021_2022 : Fabrication and commissioning of Structural steel tubular space frame structure of in IS2062 Grade and accessories as per approved specifications, drawings and directions of dept officer at site including painting with two coast of approved make and colour synthetic enamel paint over two coats of approved make epoxy primer, cost of material, labour, machinery, incidental and handling charge etc complete
od353646/2021_2022 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.60 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
6.2.2 : Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick
od354588/2021_2022 : Supplying and erection of structural steel with painted MS angles/flats of required sizes in the trenches, on roof etc., The angles/channels shall be welded/grounded in the trench/walls/truss structure. The rate shall include grounding, welding and fixing complete.( for fixing flood light luminaires on truss structure)
Storm Water Collection and Drainage system
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
12.41.2 : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
12.42.1.2 : Coupler110 mm
12.42.3.2 : Single tee with door110x110x110 mm
12.42.5.2 : Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.5<sup>0</sup>110 mm bend
12.42.6.2 : Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionShoe (Plain)110 mm Shoe
12.43.2 : Providing and fixing unplasticised- PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Electrification Works
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.10 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.12 : Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
od353564/2021_2022 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required...
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
od353837/2021_2022 : Supply and installation of 9W, 600 lumens, integral LED bulk head fitting with 4000K LED and constant current electronic driver with all fixing materials for mounting on wall. (Make: Philips Endura Bulkhead WT202W- LED6S NW-PSU-S2-PC or equivalent)..
od353838/2021_2022 : "Supply and installation of 20W - 1600 Lumen - LED surface mounted down lighter with 4000K LED and constant current electronic driver complete with all fixing materials for mounting on ceiling...(Make: PHILIPS-Cirrus MINI PRO SM200C-..LED16S-4000-PSU-OD-WH or equivalent)"..
od353839/2021_2022 : "40W - 4000 Lumen - LED batten 6500K LED and constant current electronic driver complete with all fixing materials ...(Make: Philips Smartbrite Xtra BN100C LED40S 6500 L120 PSU GR or equivalent))"..
od353840/2021_2022 : "Supply and installation of 155W - 18500 Lumen - IP66 LED flood light with 5700K LED and constant current electronic driver complete with all fixing materials for mounting on specially fabricated arms (fabrication and supply of arm not included in this item)...(Make: PHILIPS-Tango LED Floodlight - BVP483 LED185 CW SWB PSU GR or equivalent)"..
od353841/2021_2022 : "Supply and installation of 195W - 22500 Lumen - IP66 LED flood light with 5700K LED and constant current electronic driver complete with all fixing materials for mounting on specially fabricated arms (fabrication and supply of arm not included in this item)...(Make: PHILIPS-Tango LED Floodlight - BVP483 LED235 CW SWB PSU GR or equivalent)"..
od353842/2021_2022 : Supply and installation of 1200 mm sweep super efficient 5 star rated BLDC ceiling fans model with the rated voltage 160V - 265V, frequency 48 - 52 Hz. Input power: 35 Watts, Min. air delivery 230 m3 speed: 385 RPM with 3 leaf, 6 key remote, ON / OFF, 5 speeds completely prewired upto terminal block complete as required...
od353843/2021_2022 : Supply, installation, testing and commissioning of 300 mm sweep light duty exhaust fan complete with bird guard, louvers etc and other fixing accessories as required.(Havells model Turbo Force, Bajaj model No.Freshee mk2 300mm, Crompton model no. TA-300-AG, Usha model No.JET DELUXE)..
od353844/2021_2022 : Supply, installation, testing and commissioning of Single phase, 450 mm wall bracket fan , 1250 RPM, 230V, 60W, including mounting arrangement and other accessories complete as required. (Crompton Greaves model WM HIFLO 16 or Bajaj model SPECTRUM)...
od353845/2021_2022 : FLOOR MOUNTED PANEL..63 A, 4P MCCB, 16 KA - 6 nos...
od353846/2021_2022 : Supply and Providing 100A 4 pole on load change over switch in SS enclosure with provision for cable entry and exit..
od353847/2021_2022 : Fabrication, supply & installation of dust and vermin proof, wall mounting, meter box of required size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit including 100A 4 pole Switch disconnector, Cut out Fuse arrangemments, 100/5A CTs of required class - (3 Nos), neutral link etc complete as required at site..
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
od353848/2021_2022 : Supply, installation testing and commissioning of following TPN Loop in Loop out boxes, with 32A 4pole Epoxy/Bakelite connectors for connecting the cables including knockouts for glanding and termination of two nos of 4x10sqmm armoured copper cables ( for tapping connections to three nos light fixtures installed on the trusses)...
od353849/2021_2022 : Supply, installation testing and commissioning of following TPN Loop in Loop out boxes, with 32 A Epoxy/Bakelite connectors for connecting the cables including knockouts for glanding and termination of two nos of 4x10sqmm armoured copper cables ( for tapping connections to single light fixtures installed on the trusses)...
2.17 : Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
od353850/2021_2022 : Supply of following size 1.1 KV cross -linke polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code...3.5 core 70sqmm..
od353851/2021_2022 : Supply of following size 1.1 KV cross -linke polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code...3.5 core 50sqmm..
od353852/2021_2022 : Supply of following size 1.1 KV cross -linke polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code...3.5 core 25 sq mm..
od353853/2021_2022 : Supply of following size 1.1 KV cross -linke polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code...4 core 10 sq mm ..
od353854/2021_2022 : Supply of following size 1.1 KV cross -linke polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code...2 core 10 sq mm ..
od353855/2021_2022 : Supply of following size 1.1 KV cross -linke polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code...2 core 6 sqmm..
7.3.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
7.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 35 sq. mm and upto 95 sq. mm
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness
14.15.2 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
14.15.3 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
od353862/2021_2022 : Providing and fixing of Insulating Elastomeric (a generic term that includes rubbers,latex and elastomeric compounds that may be natural or synthetic or a mixture or a combination of both) mat with ISI mark 1 mtr wide and 2mm thick to withstand 1.1 KV dielectric strength as per IS 15652-2006. (Make: Electromat, Safevolt)..
od353863/2021_2022 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision..
od353864/2021_2022 : Supply & fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as required. (approximate front area 1.20sq.metre) in English,Hindi &Malyalam...
od353865/2021_2022 : Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side as required. Medium m Voltage -size 200mm x150mm..
od353868/2021_2022 : Providing and fixing Dry Chemical Powder (DCP) type fire extinguishers confirming to IS 2878 -1976 and cylinders fully charged of following capacity. 4.5 KG..
od353869/2021_2022 : Providing of set of 4 Nos. 9.5Litre capacity GI bucket painted in post office red colour with prior coat of redoxide paint and written with white paint FIRE and mounted on MS angle iron frame with bracket of appropriate size & capacity I/c filling sand etc...
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
od353877/2021_2022 : Providing maintenance free Earthing system as per IS 2309, IEC 62305 part3, IEC 60364, IEC 62561 part 2, IS 3043, UL 467 UL 96 standards.Providing maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3 m length (1m (219 20 CU) x 3 nos), having a diameter of 20mm with copper coating thickness of 250 microns with self-coupling peg & bore arrangement with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. Universal Clamp (2730 20 VA) made of SS 304 for clamping. Impact point (219 20 IP) on the bottom rod for easy insertion. Earth enhancing mineral compound (ECS GB 25 kg) is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have minimum 25 Kg of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 190mm with a weight bearing capacity of 50KN...
od353892/2021_2022 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)..
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
od353894/2021_2022 : "Supply, installation, testing and commissioning of 62.5KVA, three phase 415V,0.8pf 50hz liquid cooled diesel engine driven generator set with standard control panel, acoustic enclosure etc of the following specification. Diesel generating set comprising of diesel engine, alternator fuel tank. Diesel engine shall be suitable for continuos operation of generator set inclusive of fly wheel, flexible coupling, air cleaner, corrosion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 12V battery,..a) Alternator: 62.5kVA, 415V, 3 phase alternator with Automatic voltage regulator...b) Diesel Engine: 38.5 BHP, 4cylinder diesel engine with base frame made of channel suitable for coupling with alternator...c) Control Panel: 100A, 25kA, FP Microprocessor based MCCB set at 70A, 1Set volt meter, 3Nos. ammeters with CT, frequency meter, etc. ..d) ACOUSTIC ENCLOSURE( Integral type): Exhaust pipe inside the enclosure upto and including silencer shall be enclosed with Al.cladding over thermal insulation...(Energy meter& CTs shall be tested and certificate shall be obtained from electrical inspectorate lab and Sanction from electrical inspectorate)"..
od353895/2021_2022 : Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 20 m in stages of following sizes including suitable rain gaurd for top.Fixing shall be done with proper clamps,expansion bolts,support angle of size 40X40X6 mm fixed on the wall...
od353896/2021_2022 : Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energisation certificates from Electrical Inspectorate & KSEB, obtaining power allocation & power connection etc. for commissioning of the whole installation in the premises. All statutory payments remitted for obtaining sanction will be reimbursed on production of the original receipts...
od353897/2021_2022 : Supply, installation, testing & commissioning of 8 M High Galvanized pole with base plate similar to Keselec model no LIP 08 S A1, powder coated, including foundation bolt, nuts, washer and wiring on poles from junction box to light fixtures with 3x2.5 sq.mm FRLS PVC insulated stranded copper conductor wire including earthing etc. as required as per specifications and approved drawings on the existing RCC foundation...
od353898/2021_2022 : Supply, installation, testing & commissioning of Twin Arm style bracket equivalent to keselec model no STB D C B LIP A1 bracket 1 metre length for the 8 mtr pole...
od353899/2021_2022 : Supplyig, installaton, testing and commissioning of following LED Street Lighting luminaire having die cast aluminium housing with IP 66 body, with In-built integrated constant current Electronic LED driver, THD<10%, conforming to IS10322 Part 5 / Sec1: 2012, IS13383 Part 2 suitable for operation on 230 volts single phase, 50 Hz, AC supply including making connections etc. as required.(LM 79280 Test report to be submitted for verification) with system lumens not less than 7000 lumens, power rating not more than 120W(Make :BRP 340 LED 150 CW HO SLC S2 PSU GR, Keselec make Beluga MINI 90W NW LED or equivalent)..
5.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
9. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Bankers Construction
DIMEBAG SOLUTIONS PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .