Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹37.5 L+₹88,298 (2.41%)Rejected-Finance 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹41.5 L+₹4.9 L (13.3%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-Finance Being 3rd Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
5 Sept 2022, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR MAINT OF CI / GI / DI / PVC PIPE LINES, ENTIRE DISTRIBURION NETWORK, ALLIED WORKS INCLUDING REPAIRS TO MOTOR PANELS AND PUMPING EQUIPMENTS UNDER GE (E) BAREILLY.
2022_MES_544149_1
8218/E8
Open Tender
Civil Works
Item Rate
183 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹98,000
Yes
29 Sept 2022
8 Aug 2022
7 Sept 2022
8 Aug 2022
5 Sept 2022
22 Aug 2022
8 Aug 2022 - 15 Aug 2022
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope / gradient for laying cables/pipes etc. including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed
Removal of surplus excavated soil exc. 50 mtr but n. exc. 250 mtr distance and depositing where directed at a level not exceeding 1.5 M above the starting point etc. complete all as specified and directed.
Supply and laying new dry river sand laid in trenches 8.0cm below the cable and 15.0cm above the cable and gently punned to 18.0cm as cable cushioning and covering complete all as specified and directed. (Note:- Only punned 18 CM thick sand cushioning shall be measured and paid)
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed
M&L for boring the holes under roads pavements, hardstanding by treanch less techonology, using ultrasound technique and necessary machine including CI Pipe of 100 mm/150 mm bore suitable for 0.4 mpa working pressure complete all as specified and directed.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed
M&L for 100 mm thick, PCC 1:2:4, type B2 (using 40 mm graded stone aggregate) as in floor / sub base complete all as specified and directed.
M&L for 40 mm thick, PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in floor, finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete making good as per existing surface etc., complete all as specified and directed .
Supply and laying 25 mm bore steel water tubing medium grade fixed with wall / laid under floor with all GI fittings as required at site including taking down old 25 mm bore steel tubing with connections, complete all as specified and directed.
All as per Srl item No. 10 here in before but 20 mm bore
All as per Srl item No. 10 here in before but 15 mm bore
S&F 50mm bore, gun metal iron gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe including dismantling the old unserviceable existing valve complete all as specified and directed.
All as per Srl item No. 13 here in before but 40 mm bore
All as per Srl item No. 13 here in before but 25mm bore
All as per Srl item No. 13 here in before but 20 mm bore
All as per Srl item No. 13 here in before but 15mm bore
S&F 80 mm bore 'D' Joint complete all as specified and directed.
All as per Srl item No. 18 here in before but 100 mm bore
All as per Srl item No. 18 here in before but 150 mm bore
All as per Srl item No. 18 here in before but 200 mm bore
M&L for repair / rectification of leakage / blockage to water supply distribution lines of 15mm to 20mm bore GI tubing by necessary excavation, returning / filling as required, tightening of lose joints of union, elbow, socket nipple as per site requirement including for replacement of GI union, socket, nipple as required complete all as directed.
All as per Srl item No. 22 here in before but 25 mm to 40mm bore
All as per Srl item No. 22 here in before but 50 mm bore
M&L for dewatering trenches manually for repairing joints by cocking and inserting spurn yarn and Run lead joint, making good / leakless the existing 80 mm bore joint including necessary excavation and earth work like returning, filling and removal etc., complete all as specified and directed.
All as per Srl item No. 25 here in before but 100 mm bore
All as per Srl item No. 25 here in before but 150 mm bore
All as per Srl item No. 25 here in before but 200 mm bore
M&L for dewatering trenches, Repair / rectification of leakage and blockage of 110 mm bore PPR pipes manually repairing joints by inserting proper accessories and fittings of PPR pipes making good / leakless the existing joint including necessary excavation and earth work like returning, filling and removal etc., complete all as specified and directed.
All as per Srl item No. 29 here in before but 90 mm bore
All as per Srl item No. 29 here in before but 75mm bore
Supply and fixing CI fittings for Socketed pipe, CI Bends, connecting pieces, bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed.
Supply and fixing DI fittings for Flanged pipe, DI Bends, connecting pieces, bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed.
S&F of 150 mm bore, Non Return Valve at various pump houses complete as specified and directed. Make: KIRLOSKAR, RAMCO or equivalent as approved by GE.
All as per Srl item No. 34 here in before but NRV of size 100 mm bore
M&L for provision of new wash out points at 150 mm bore pipe by proper cutting and screwing of existing DI / CI / GI pipe fixing reducer tee of suitable size, supplying and fixing, Jointing, testing CI sluice valve by fixing 02 Nos at each wash out point with flanged ends including necessary mountings nuts, bolts washers and packing fibers gasket on both end and making pit chamber including iron frame cover 3.15 mm thick with locking arrangements complete all as specified and directed.
All as per Srl item No. 36 here in before but Wash out point at 100 mm bore pipe
All as per Srl item No. 36 here in before but Wash out point at 80 mm bore pipe
S&F in replacement PTMT bib cock of 15 mm bore size, white, standard with male thread, complete all as speciifed and as directed.
S&F sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 150 mm bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. including taking out old existing unservicable sluice valve including making arrangement for safe working complete all as specified and directed. Make: BIR, KIRLOSKAR, Kartar
S&F sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 100 mm bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed. Make: BIR, KIRLOSKAR, Kartar
M&L for sluice valve for 80 mm to 200 mm bore, high tensile stainless steel spindle, including nuts, bolts and gas kit, glands and refixing after repair etc. or dismantling and taking out old sluice valve any size, complete all as specified and directed.
Supply & laying / fixing in floor / trench, 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes of size PN-16, 75mm OD (SDR– 7.4), ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints including taking down PP-R and PVC pipe and connections complete all as specified and as directed
All as per Srl item No. 43 here in before but PN-16 pipe, 90mm OD (SDR – 7.4)
S&F in replacement PPR gate valve (brass insert) of size 75 mm bore including connection and testing complete all as specified and directed.
S&F in replacement PPR gate valve (brass insert) of size 90 mm bore including connection and testing complete all as specified and directed.
M&L for screwing existing steel tubing of bore 40/50mm in position for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
M&L for screwing existing steel tubing of bore 20 mm in position for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
M & L for construction of brick masonry valve pit of size 90x90x90cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) both externally and internally, external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including 40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil including demolition of old unserviceable existing valve pit & pit cover complete all as specified & directed.
M&L for running welding in any position as and where directed n.exc 6mm gitrh (thickness of metal to be welded) complete all as specified and as directed.
Laying only 80 mm bore steel water tubing with and including all GI fittings as required at site including taking down old unserviceable steel tubing and connections complete all as specified and directed. (Note:- GI pipe shall be issued under Sch B free for fixing.)
All as per Srl item No. 51 here in before but 50 mm bore tubing
All as per Srl item No. 51 here in before but 40 mm bore tubing
Taking up cast iron/ PVC / HDPE water mains of 100 mm 150 mm bore of pipes (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead.
Supply and laying of 150 mm bore centrifugally cast (Spun) ductile iron pressure pipe with spigot & socket end, class K-9 in any length laid in trenches, conforming to IS-8329/2000 with cement mortar lining with and including rubber gasket jointing conforming to IS-15382 tyton joint complete with all fittings e.g Tee, Bends etc all as specified and directed.
All as per Srl item No. 55 here in before but 100 mm bore
M&L for run lead joint Spigot and socketed pipes and fittings, for the 100 mm bore pipe complete all as specified and directed.
All as per Srl item No. 57 here in before but 150 mm bore
M&L for making connection of PP-R distribution branches 50 to 75 with PP-R main by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
M&L for making connection of PP-R distribution branches 16 to 40 with PP-R main by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
M&L for making connection of PP-R distribution branches 75 to 110 with PP-R main by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
S&F in replacement Pneumatic Actuator valve of size 80mm bore as per site requirement complete all as specified and as directed.
S&F in replacement foot valve 100 mm all as specified and as directed.
M&L for preparation of old concrete / plastered surfaces by scrapping, brooming etc and applying two coats of exterior weather proof acrylic based anti-fungal paint (100% acrylic) smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories over dome, wall, columns, beams including all pipe lines etc of overhead reservoir using scaffolding & necessary safety precaution complete all as specified and directed for the following RCC over head reservoir:- (a) RCC overhead reservoir 100000/50000/25000 gallon capacity, 50 to 60 feet staging. Note :- Colour status shall be as under :- (i) Rising main - Blue colour. (ii) Delivery main - Green colour. (iii) Washout main - Red colour. (iv) Overflow main - Yellow colour.
S&F in replacement MS ERW column pipe screwed 150 mm nominal bore having wall thickness not less than 7.11 mm electric resistance welded with MS flanged 16 mm thick heavy duty confirming to IS 6392 including 2 mm thick rubber sheet and steel nuts and bolts 10 mm long with washer complete all as specified and directed.
S&F in replacement submersible pump & motor electric driven 415 Volts, TP suitable for 200/250 mm dia bore well casing pipe of size 200/250 mm supply complete of 41 HP complete all as specified and directed.
S&F in replacement submersible pump & motor electric driven 415 Volts, TP suitable for 200/250 mm dia bore well casing pipe of size 200/250 mm supply complete of 50 HP all as specified and directed.
Supply install in repair and commissioning of Granular chlorination dosing pump of high pressure single head gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U S GPD and adjustable high pressure of up to 100 PSI (7 kg/cm2) or more, power input 230 V, 50 HZ self priming with nonmetalic with connecting nuts, ferrules with all accessories including lead, tubing connection injection check valve complete all as specified and directed. Make :- Declibac, Briozing, potter & watts
Supply install and commissioning in repair of Multi-Cavity water sanitiser/ conditioning stationproportinal dosing arrangement at zero discharge of the power ree automatic system, 100 Ltr. Tank, Cavities are compieted with Lids. Attachement -Centrifugal pump with following specifications:- Power-1 HP,0.75 KW,pipe size (suction ), 1",Delivery pipe 1",Total Head up to 6 bars, Discharge- up to 3700 LPM,Over flow valve,water inlet valve,outlet valve ( for o line automatedgravity flow ) drain valve with all assessary complete all as specified and directed. Model-STEQUA ADS PRO System. Make- Declibac technologies or equivalent as approved by GE
Supply only Chlorine tablets contained in plastic cylindrical -sealed disposable sanitizer refill for disinfeetion of drinking water with arrangement for controlled relese of disinfectant in water suitable for operation through for recommended dosing system. Relacecement indication visual & weight variation water cotact orifice design: Sealed when dry, exposed upon immersion oxperation type, Non contct, non inhalatory complete all as specified and directed. Note :- Each Set of 25 refill shall be measured for payment purpose
Supply, installation, Commissioning and testing LT Busbar chamber, size of 600x600x400 mm for 3 phase, 6 wire, 415 Volts, AC , 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape/ size canopy on top, made out of 3.15 mm thick MS sheet with using 25mm x 25mm x 5mm angle iron frame and supports, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement and including PCC work for fixing panel legs and bus bar of Copper conductor suitable shape and size, 6 Nos of 200 amps rating including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size and dismantling and taking Out old U/S LT Busbar chamber of P/H-29 & 24.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor size of 120 sqmm,3.5 core, 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road / path / drains / along wall / floor / pole / equipment etc. cross sectional area including cable lugs of following size including taking down of existing cable complete all as specified and directed.
K.S.Traders
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .