EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Carrying out Restoration, Upgradation of defunct damaged electric system of ground floor of Sainik Bhawan Batamaloo Zila Sainik Welfare Office Srinagar
2026_PWDJK_301723_1
NIT No.268/2025-26 Dt/29/01/2026
Open Tender
Electrical Works
Percentage
10 days
Batamaloo srinagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹8,005
29 Jan 2026
29 Jan 2026
14 Feb 2026
29 Jan 2026
13 Feb 2026
29 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge )single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge )single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.)
Wiring for 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.)
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. For AC's
Supplying and fixing following modular switch/ socket ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.) with modular plate and cover including switch box and connections etc. as required.
5/10 amps switch
15/16 amp switch
3 pin 5/10 amp socket outlet
6 pin 15/20 amp socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ), single core cable in surface/ recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit as required.
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
(f) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, complete
Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/Crompton/ Trilux /Wipro make / sample to be approved before installation..
Supply installation testing and commissioning of 7 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/Crompton/ Trilux /Wipro make / sample to be approved before installation..
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Havell Coral / eq. make to be approved by EIC.
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor / eq. make to be approved by EIC incl. PVC Block.
S/F testing and comm. Of 20 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro/ eq. make. sample to be approved before installation..
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/Hager / eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
4 way, Double door ( 12+4)
8 way, Double door ( 24+4)
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. legrand / Schinider/ L&T ./equivalent make as directed by engineer incharge.
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
c) 40-63amp TPN MCB
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Design, Fabrication of panels of different sizes, Supplying, Installation, Testing and Commissioning of panels, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
a)200A 4P MCCB 50 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
b) 4 No. of Aluminium Bus Bar of 400 Amp.
c)Digital meters and phase indicators -1 set.
d) onload Change over switch 160 Amp for generator.Front operated.
e) 4 No. of Aluminium Bus Bar of 300 Amp.
c)Digital meters and phase indicators -1 set.
d) onload Bypass Change over switch 160 Amp for generator.Front operated.
Inverter Incommer
(a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB / eq. make to be approved by EIC.
(b) 200 Amp 2 strip bus bar
c)Digital meters and phase indicators -1 set.
OUTGOING:
a)100 amp DP MCB 10 K Legrand/ Shinider/ABB make, sample to be approved before installation..
b) 40-63amp DP MCB
c) space for 12 way MCB's
Providing of Chemical earthing as per IS standards by way of digging 2 mt. deep pit then embedding 2 meter copper bound G.I Earthing electrode , 80mm dia. connecting the plate with main control board by copper wire/ strip ( to be paid seperately) . Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
Engaging of highly skilled labour / Electrician/ IT Related personal for carrying out I.T repairs at site, Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets, servicing of panels and allied works, complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out repairing works etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_978933.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .