Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹56.7 LAccepted-AOC 35 A 60 RAMPUR GARDEN BAREILLY UP | BAREILLY | BAREILLY | UP | L-1 | Accepted-AOC Accepted | |
| 2 | L2₹62.7 L+₹2.3 L (3.83%)Rejected-AOC R O 89 PRABHAT NAGAR NEAR RAM JANKI MANDIR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L2 | Rejected-AOC Being higher bid | |
| 3 | L3₹65.8 L+₹5.3 L (8.81%)Rejected-AOC | L3 | Rejected-AOC Being higher bid | |
| 4 | L4₹66.8 L+₹6.4 L (10.5%)Rejected-AOC 160 PREM NAGAR BAREILLY | L4 | Rejected-AOC Being higher bid |
Tender Value
₹1.7 L
EMD Value
₹1.7 L
Closing Date
13 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Office BAREILLY
HQ, CWE, MES, Station Road, Bareilly
CA NO.CWE BLY/GE (W) / 45 OF 2023- 202SPECIAL REPIARS/REPLACEMENT TO BLDG NO T-92,T-94 OF JAT REGT CENTRE AND REPLACEMENT OF AC SHEETS OF BLDG NO T-95 (NE PENSION OFFICE) TO GALVANISED SHEET ALONGWITH FALSE CEILLING OF JRC UNDER GE (WEST) BAREILLY
2023_MES_627383_1
8100/B/778/E8
Open Tender
Civil Works
Item Rate
270 days
GE WEST BAREILLY
As Per NIT
6 documents required · 6 mandatory
₹1,000
GE West Bareilly
₹1.7 L
Yes
29 Jan 2024
8 Nov 2023
15 Dec 2023
8 Nov 2023
13 Dec 2023
29 Nov 2023
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove complete all as specified and directed.
Dismantling of old existing tiles including bedding layer and M&L for non-skid ceremic coloured tiles 8 to 10 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match of tiles over and including 15mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
All as per serial item No 2 as above but as in vertical surfaces of tiles and rendering 10 mm thick in cement mortar 1:4 complete all as specified and directed.
Dismantling of old existing kota stone and M&L for 20-25 mm thick machine cut pre mirror polished kota stone slab as in floor, jointed and pointed with grey cement slurry fixed with pigment to match to shade of the slab including over and including 20 mm thick bedding layer of cement mortar 1:6 complete all as specified and directed.
All as per serial item No 04 as above but as in tile in vertical surfaces but over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified.
M&L for Providing & injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar 1:2 to match the existing apron complete all as specified and directed.
M & L for Post Construction Anti TermiteTreatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor sall as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 to match the existing surface complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 to match the existing surface complete all as specified and directed.
S&F for 125x60mm pressed steel frames ( made from PBI sheet 2mm thick) for door with one or more rebate, inner surface of the frame shall be treated with a coat of bituminous paint, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS flat at bottom of the frame etc, PCC 1:3:6 Type C0(using 12.5 mm stone agreegate) as in filling for pressed steel frame with and including two coats of wooden texture finished paint over a coat of red oxide primer on the frame surface complete all as specified and directed.
S&F for 105x60mm pressed steel frames ( made from PBI sheet 2mm thick) for door with one or more rebate, inner surface of the frame shall be treated with a coat of bituminous paint, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS flat at bottom of the frame etc, PCC 1:3:6 Type C0(using 12.5 mm stone agreegate) as in filling for pressed steel frame with and including two coats of wooden texture finished paint over a coat of red oxide primer on the frame surface complete all as specified and directed.
S&F for 30 mm thick flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specsified & directed.
M & L for 35mm thick plain framed glazed and skeleton shutter open rebated & prepared to receive glass, gauge etc, with sash bar edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass including campsule mesh tightly fixed with the glazed and skelton door shutter etc, of 2nd class hard wood, members of shutters as specified in SSR Part - I Section 8 clause 8.24 (a) fitted to chowkats complete all as specified and directed.
S&F for 100mm long stainless steel butt hinges ISI marked complete all as specified and directed.
S&F for 200mm long aluminum anodised, barrel tower bolts of extruded section and fixed.
S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, brass body and tongue with hard drawn steel spring fixed to door complete all as specified and directed.
S&F for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 300 mm size, MS ordinary rat tail rod pattern springs including roller and roller plate complete including fixed to wooden and steel chowkats complete all as specified and directed.
M&L Preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L painting to wood and wood based surfaces of any description exc 10cm with or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of newly or previously untreated surface complete all as specified and directed.
M & L preparation of old steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for painting to steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface complete all as specified and directed.
M & L for Plain Cement Concrete 1:3:6 type C-1(using 20 mm graded aggregate) as in bed blocks for hold fast and similar work etc complete all as specified and directed.
Taking down existing cement plaster and M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using WPC @ 3% by weight of cement or as per manufacturer's instruction which is more finishing the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed. Note :- WPC shall be measured and paid seperately.
M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using WPC @ 3%by weight of cement or as per manufacturer's instruction which is more newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed. Note :- WPC shall be and paid seperately.
Supply only liquid water proofing compound conforming to IS specification.
Taking down existing cement plaster and M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed.
M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed.
Taking down existing cement plaster and M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) finished including taking down plaster the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed.
M&L for applying 1 mm thick layer of Birla wall care putty on wall surfaces including preparation of surface complete all as spcified and directed.
M&L Preparation of old decorated surfaces and applying one coat of white wash on ceilings surfaces and rubbing down with sand paper to have even and smooth surfaces complete all as specified & directed.
M & L for complete removal of existing treatment on wall by scrapping with mechanical sander (having mechanical vaccum machanisum) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour and applying two coats of oil bound distemper on wall surface with airless electric sprayers over a coat of primer applied using electric spayers complete all as specified and directed.
M & L applying two coats of oil bound distemper on new plastered wall surfaces with airless electric spayer over a coat of primer appiled using airless electric sparyer complete all as specified and directed.
M & L applying one coat of cement based paint on old decorated or undecorated wall, roof surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified.
M&L Two coats of cement base paint on new plastered or unplastered wall surfaces over a coat of primer of any description including preparation of surfaces complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan to any radius in half brick thick walls built in CM (1:4) all as spd and directed
M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of sunshades, shelves, lintels, Chajja ( up to IIIrd floor) etc making good, cutting out exc 10cm and not exc 20 cm girth in RCC chajjas in brick walls complete all as specified and as directed.
Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs, cupboards and stair case similar work carefully and matching to adjoining disturbed surfaces all as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for.
M & L form work to edges of concrete rough finished surface flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work for rough finish surface complete all as specified and directed.
Form work to soffits of suspended slabs flat surface of concrete for rough finished surfaces of concrete not exceeding 200mm thick complete all as specified and directed.
M & L formwork to sides and soffits of lintels,lintel bend, beams etc rough finished surfaces of concrete complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F TMT bars 5mm and over upto and including 10mm dia as in stirrups/spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specified and directed.
M&L RCC 1:1.5:3 type B1 using 20 mm graded stone aggregate as in slab, shelves and stair case etc.all as specified and directed.
M&L RCC type B 1, 1:1.5:3 (20mm graded agg) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and directed..
Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx 50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and two coat of Dr fixit /pidilite new coat ezee at interval of 8 hours cure for the surfaces complete all as specified as directed.
Demolition of cement concrete (un-reinforced), in any position and paving n.exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair including forming 10 mm wide joints at not exceeding 3 m distance between adjoining slabs shall not exceed 10 mm in thickness and shall be filled with bitumen mastic i.e. bitumen and sand in proportion 1:2 all as specified or as directed.
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floors, sub base, apron etc and finishing the surface evn and smooth without using extra cement complete all as specified and directed.
Dismantling of exiting tile/stone and M&L for 18-20 mm thick polished Granite stone (black colour only) work as in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing and jointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm screed bed in cement mortar 1:6 complete all as specified and directed.
Rounding/moulding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed
S&F in repairs stainles steel (304 Grade) Curtain Rod 25 mm dia of approved quality with two number decorative design as approved brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod complete all as directed and specified.
S&F steel windows with pressed steel frame of size 95mmx45mm (thickness of PBI Sheet 1.25 mm ) side hung shutter including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar ( open out side ) and wie gauged openable shutter without glazing bar ( open inside ) dovetailed or welded complete all as specified and all as per DRG No TD/088 dt 07 Jan 2002 ' Note :- (i) Two shutters ie wire guaged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit ' (ii) rate for filling PCC 1:3:6, type C0(using 12.5 mm graded syone aggregate )in frame deemed to be included in quoted rates ' (iii) MS grill shall be measured and paid seperatly under relevant item of schedule
S&F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed.
S&F sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in square exc 0.5 Sqm each pane complete all as specified and directed
Dismatling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs / blankets, any thickness, including cover fillets & electrical fitting carefully for reuse on the same on the new ceiling complete all as specifeid and directed.
M&L for E-board false ceiling consisting of powder coated GI wall angle, main T and cross T of 25mmX 25 mm X 1.40 mm thick grid frame work, joist, angle/ Tee as directed and mild steel wire hook not less than 6 mm dia with arrangement for adjusting height of ceiling and including provn of 4 mm thick E- Classic board in pannelof size 600X600mm with necessary off cut complete all as specified and directed.
Dismatling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based profile sheet (Mangalore pattern) steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling framed timber scantlings 40 sq. cm and over in section, in any complete all as specified and directed.
Dismantling unframed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position complete all as specified and directed,
Dismantling unframed timber scantlings in fillets, rails, posts, rafters, purlins, etc. 40 sq. cm and over in section, in any position complete all as specified and directed,
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade Fe-410 gde st- 240 complete all as specified and directed.
S&F for computerised reflective letter / bldg number on ACP sheet (size 45mm x 45mm) and fixing with 04 nos of screw, rawal plug etc on wall in front of building complete all as specified and directed.
S&F 6 mm thick solid PVC boards one side prelaminated and other side plain white lamination, fixed on back side of wall for cupboards & cabinets etc, fixed with SS screws, fasteners and adhesive as per instructions of manufacturer, complete all as specified and directed.
S & F in repairs for powder coated aluminium shutter glazed with 5.50 mm thick glass and openable one or both side, using aluminium anodised powder coated section, thickness of anodising not less than 15 micron including aluminium cleat, PVC rubber gasket track, handle, lock,etc complete and repairing distrubed surfacr of wall with cement surface complete all as specified and directed. Note :- (a) Bottom /top section of the track 65 mm x 40 mm x 1.5 mm. (b) Rails section 50 mm x 40 mm x 1.5 mm (c) Styles 60 mmx 40 mm x1.5 mm
S & F in repairs for 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
M & L for wrought timber framed and fixed for Second class hardwood (Sal) in scantlings , roof truss etc complete all as specified and directed.
M & L for fixed unframed timber second class hard wood (Sal) scantlings as in fillets, rails, posts, rafters, purlins, etc. in clean sawn in any position complete all as specified and directed.
Providing & fixing false ceiling of PVC sheet of size 600 mm x 600 mm and minimum 3 mm thickness in multi colour geometrical designs & light in weight, 100% waterproof, flame retardant,can be made available in semi perforated / perforated structure stuck with high density EPS for sound acoustic applications , placed on aluminium / powder coated metal grid complete all as specified and directed.
S & F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
Taking down carefully UNSV main switch DBs of any description of an size in any position complete all as specified.
Taking down submain wiring of any description including all accessories complete all as specified and directed.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable (FRLSH) with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes and covered with 3 mm thick plastic laminated sheet cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- (a) One light / fan/ exhaust fan point controlled by one switch.
(b) One 5 pin 5/6Amp switch socket out let point on an independent board complete all as specified and directed.
(c) One 5 pin 5/6 Amp socket out let point controlled by one switch on same board complete all as specified and directed.
All as per above, Item No 81 here in before but for one 15/16 Amp 5/6 Pin switch socket out let independent with 4 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 4.0 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified.
S&F switch piano flush type 6 Amp single pole one way.
S&F socket out let 2 in 1 flush type 6 Amp 5 Pin complete.
S&Fswitch piano type 16 Amp flush type 240 Volt complete.
S&Fsocket out let 6 Pin 2 in 1, 6/16 Amp flush type 240 Volt complete.
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed.
Supply and fix in replacement of fan regulator 150 watts electronic flush socket type with five stepped range hum free complete all as specified and directed .
Supply and fixing surface mounting LED light fitting aluminium extruded T-5 batten , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed.
M & L for replacement of lamp holder, PVC / Poly carbonate, insulated body modular type with back plate batten/angle type for batten fittings complete all as specified and & directed
Taking down carefully ceiling fan and keeping in safe custody for reuse at site after bldg repair incl Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. painting and minor repairs etc complete all as spd and directed.
Taking down carefully wall fan of any description and keeping in safe custody for reuse at size after bldg repiar incl, cleaing all dust etc and minor repiars etc complete all specified and directed.
Supply & Fixing security light fitting, LED type, 30 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source with integrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm (FRLSH) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLSH) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 4.0 sqmm (FRLSH) and one run of 2.5 sqmm (FRLSH) copper conductor shall be measured as one unit length.)
S&F MCB SPN 40 to 63 Amp 240 volt, 10 KA, 'C' series complete all as specified and directed.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed by the Engr-in-Charge.
S&F MCB TPN 40 TO 100 Amp 415V 'C' curve 10KA complete all as specified and directed.
S&F in replacement flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete all as specified and directed.
S&F in replacement sheet metal enclosure TPN DB 4 way 415 V with double door IP-42 protection deachable gland plates, flush mounting for MCB fitted with bus bar, earth bar and netural links complete all as specified and directed.
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced and as per Electrical Plate No. 3 of SSR Part-I complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note : Two runs of 6.0 sqmm (FRLS) and one run of 6.0 sqmm (FRLS) copper conductor shall be measured as one unit length.)
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
MARUTI BUILDERS
Harsha Consultant and Builders
Builders Harpal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .