Municipal Commissioner, Ahmedabad
Augmentation of Civil Work with SITC of Pumping Machinery with Related Mechanical, Electrical and Instrumentation work of Baldevnagar Water Distribution Station in Vejalpur Ward of the South West Zone of AMC.
361854
E-Tender Notice/2026-27 T.No.6
Open
Miscellaneous Works
Works
Ahmedabad
3 documents required · 3 mandatory
₹3,600
Municipal Commissioner, Ahmedabad
₹2.6 L
2 Nov 2026
2 Nov 2026
2 Nov 2026
25 Nov 2026
2 Nov 2026
120 days
(4) Date of e-Tender (Technical Bid)
Municipal Commissioner
Ahmedabad Municipal Corporation Green Design & Engineering services Pvt.Ltd.
Sardar Patel Bhavan 520-521, Shivalik Square,
Ahmedabad – 380 001 Nr. Adani CNG Pump,
Gujarat (INDIA) Ramapir No Tekro, Old Vadaj,
Fax : (091) – 79 – 25350926 Email- [email protected]
Website : www.egovamc.com
AHMEDABAD MUNICIPAL CORPORATION
Water Project Department
NAME OF WORK :-Augmentation of Civil Work with SITC of Pumping Machinery
with Related Mechanical, Electrical and Instrumentation work of Baldevnagar Water
Distribution Station in Vejalpur Ward of the South West Zone of AMC.
SUMMARY OF COST FOR ESTIMATE
SR NAME OF WORK AMOUNT
i Augmentation of Civil Work
B MECHNICAL ELECTRICAL WORKS
i Mechanical Work
ii Instrumentation Work
iii Electrical Work
Total Cost Without GST (A + B)
Bidder’s Stamp and Initials
AHMEDABAD MUNICIPAL CORPORATION
WATER OPERATION
NAME OF WORK :-Augmentation Work of Baldevnagar Water Distribution Station in Vejalpur Ward
of the South West Zone of AMC.
ABSTRACT SHEET OF CIVIL WORK
(COMPOUND WALL, TOILET BLOCK & OTHER REPAIRING WORK)
Item no. Description Qty. Rate Unit Amount
Demolition of Brick work & stone masonry
including stacking of serviceable materials and
disposal of unserviceable materials with all lead
and lift. (i) In cement Mortar.
Demolition and disposal of unserviceable
2 materials with all lead and lift.(i) Unreinforced 20.00 609.26 Cmt
cement concrete
Demolition and disposal of stacking of
serviceable materials and disposal of
unserviceable materials with all lead and lift (i)
Clearing and grubbing road land including
uprooting rank vegetation grass
bushes,shrubs,sapling and trees girth up to
4 0.10 28393.04 Hectare
mm removal of stumps of trees cut earlier and
disposal of unserviceable materials (C) By
mechanical means in area of light jungle
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
5 architraves, holdfasts and other attachment etc. 65.00 187.71 Each
complete and stacking them within all lead and
lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
6 architraves, holdfasts and other attachment etc. 20.00 251.34 Each
complete and stacking them within all lead and
lift.(ii) Exceeding 3 Sq.M. in area.
Dismentling barbed wire in fencing including
making rolls and also including dismentling
fencing posts including all earth work concrete
7 in base and making good the disturbed ground 250.00 66.81 Rmt
stacking useful materials as directed and
disposing as directed and disposing of the
unserviceable materials with all lead and lift.
Removing and scraping of old deteriorated
plaster of any thickness from all Structural &
Non Structural member including stacking of
serviceable material and disposal of
unserviceable from site of work with all lead
Supplying Electric breakar machine for RCC
9 slab or Asphalt demolishing work on site by 10.00 1082.14 Shift
using operator, fuel, power supply etc. complete
as directed.(no payment should be allowed for
non working condition of machinary and for
pipeline excavation and M.H. work.allowed
only for break down work)(based on previously
approved rate by CE Sir)
Boring holes 3.5 m deep in ordinary soil (for
cast in situ piles) and getting out the soil and
10 disposal of the surplus excavated soil as 50.00 1524.09 Each
directed within a lead of 50 Meter for following
diameter of pipes.(iii) 300 mm
Add to or deduct from the rate for Bore Holes
of 3.5 m Depth, if bore holes are made deeper
or shallower than 3.5M. for Piles of following
diameter.(iii) 300 mm
Providing and Laying of Rubber Moulded
Paver Block Grey/Coloured 60 mm thick, M-35
Grade of any size ; shape (Usually Uni-Paver
Blocks) using black trap good quality aggregate
of 20 mm nominal size for footpath, parking
areas, service lanes and other areas as
mentioned in the drawing / instruction of
engineer in charge. Cost includes formworks
using rubber mould, Rate providing and laying
paver blocks as per required grading and
specification. The paver block shall be
mechanically compacted. The work of paving
blocks shall be executed in line and level by
skill mason of flooring work only. It should be
laid in such a way that the no cutting of the
paver block to be necessary. If cutting of paver
block necessary then it should be cut by
machine only and carting. The finished surface
of the paver block shall have reasonably good,
plain finished. Paver blocks shall be compacted
and shall be relaid if necessary. Gravel or such
type of materials shall not be allowed for
production. Laying on 5 cms thick sand
Supplying and fixing of 300 mm-L x 150 mm-
B x 380 mm-H Kerb block for Footpath in M-
20 grade using 20 mm nominal size black trap
aggregate of Sevaliya/Timba or equivalent
quality for pre-cast blocks, reasonably exposed
finish/ formwork , mould with well equipped
with vibratory system for kerb stones of
approved design including curing, etc.
complete, including the cost of formwork etc.
complete. The rate shall also include necessary
cutting of asphalt, fixing the Kerb stones in line
and level on 5 cm thick sand bedding with
necessary equipments and materials. The rate
shall also include the flush pointing in CM (1:3)
for all joints of the kerbstones. Filling of zari
alone the sides of the kerb stone fixed with
Bituminous concrete Bituminous concrete /
C.C. mixed in proper position to flush with the
road surface as directed by Engineer in change
to form a portable mixture.Laying on 5 Cms
thick sand Bedding
Laying on 5 Cms thick sand Bedding 265.00 354.40 Rmt
Excavation for foundation for loose and soft
soil including sorting out and stacking of useful
materials and disposing of the excavated stuff
up to 50 meter lead.
Conveyance charge of earth, lime, murrum,
building rubbish, manual garbage, sludge,
excavated rock, fly ash, aggregate of any kind
etc. Upto 5.0 Km lead.
Conveyance charge of earth, lime, murrum,
building rubbish, manual garbage, sludge,
excavated rock, fly ash, aggregate of any kind
etc. 5Km to 10 Km lead.
Filling with available excavated earth
(excluding rock) in trenches, plinth, sides of
17 foundation in layers not exceeding 20 cm in 330.00 130.39 Cu.m.
depth consolidating each deposited layer by
ramming and watering.
Providing and casting in situ C.C. in grade M-
15 (approx. corresp. to prop. 1:2:4) (proportions
as per mix design or as per Table 9 of IS456
2000 in masses by weigh batching ) using
granite, quartzite trap metal of size 6 mm to
mm for RCC work, including scaffolding
centering, form work, needle vibrated
consolidation, curing comp. (excluding cost of
reinforcement and neat finishing) with
centering and shuttering/deshuttering etc.
comp. for structure for other than water
retaining. Footing (with form work)
Providing and casting in situ C.C. in grade M-
15 (approx. corresp. to prop. 1:2:4) (proportions
as per mix design or as per Table 9 of IS456
2000 in masses by weigh batching ) using
granite, quartzite trap metal of size 6 mm to
mm for RCC work, including scaffolding
centering, form work, needle vibrated
consolidation, curing comp. (excluding cost of
reinforcement and neat finishing) with
centering and shuttering/deshuttering etc.
comp. for structure for other than water
retaining. Footing (without form work)
Providing and cast in situ C.C. in grade M-30
proportions of ingredients as per mix design by
weigh batching using granite, quartzite trap
metal of size 12 mm to 20 mm and or 6 mm to
12 mm including scaffolding centering
formwork, needle vibrated consolidation, -
curing and hydraulic testing etc. complete
(excluding cost of reinforcement) with
20 centering and shuttering/deshuttering etc.
camp. up to 6 meter height /depth Av. G.L.for
all water retaining structures
a) R.C.C. Raft and footings with shuttering 30.00 8213.00 Cu.m.
b) R.C.C. walls 85.00 8083.00 Cu.m.
c) R.C.C. Staircase 0.00 8213.00 Cu.m. -
c) R.C.C. Beams 50.00 8486.00 Cu.m.
d) Columns 10.00 9317.00 Cu.m.
e) Top Slab of Sump 35.00 8213.00 Cu.m.
Providing and cast in situ C.C. in grade M-20(
proportions as per mix design or as per table of
IS456 2000 in masses by weigh batching) using
granite, quartzite trap metal of size 6 mm to
mm for RCC Work including scaffolding
centering formwork, needle vibrated
consolidation, curing complete up to 6 meter
depth or height (excluding cost of
reinforcement and neat finishing) with
21 centering and shuttering/ deshuttering etc.
complete for structure other than water
A) RCC Footing 365.00 5520.00 Cu.m.
B) RCC column 25.00 7363.00 Cu.m.
C) RCC Beam 50.00 6722.00 Cu.m.
D) RCC Coping 0.00 6722.00 Cu.m. -
E) RCC Slab 5.00 6504.00 Cu.m.
F) RCC Wall 110.00 6779.00 Cu.m.
Supply cutting, Bending, Binding and placing
in position steel as per plan and design and as
per ISS 2502 including cost of steel and binding
wire for reservoirs/ structures only including lift
up to 6 meter height or depth below G.L. for all
Deformed(TMT)bars confirming to relevant IS
Fe-500 grade for all diameters.
Brick work using common burnt clay building
bricks having crushing strength not less than
35kg / Sq. C. M. in ramp, steps and Foundation
23 & Plinth in cement morter1:5 (1 cement : 5 25.00 4051.78 Cu.m.
coarse sand) including racking out joints,
curing, scaffolding required if any etc.
complete, as directed. (B) Conventional
Brick masonry in cement mortar (1:5) using
common burnt clay building bricks having
crushing strength not less than 35kg/cm2
including scaffolding,curing, etc. complete for
walls, parapets, etc. at all levels.
20 mm thick sand faced cement plaster on walls
upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M.
1:3 (1-cement : 3-sand) and 8 mm thick
finishing coat of C.M. 1:1 (1-cement : 1 sand)
Providing and applying 15 mm thick cement
plaster in single coat on brick work with
floating coat of net cement slurry for interior
plastering of pumphouse and outside plastering
26 of sump upto finished even and smooth in 630.00 224.79 Sq.mt
Cement motar 1 : 3 (1 cement : 3 sand)
including racking out joint curing, scaffolding
required if any, with necessary cement finishing
etc. complete as directed.
Interior plain faced 15 mm thick cement plaster
(1:3) with floating coat of neat cement slurry on
Underneath Ceiling of top of UG tank where
27 specified on drawings and or engineer in 250.00 298.86 Sq.mt
charge at all levels including scaffolding,
curing, etc. complete. This rate shall include
moulding where specified.
Providing and applying 20 mm thick inside
cement plaster with water proofing agent on
inside of sump consisting of 12 mm thick
backing coat of CM 1:2 (1 cement : 2 sand) and
8 mm thick finishing coat of CM 1:1 (1 cement
: 1 sand) etc. complete including necessary
curing, scaffolding required if any etc.
Writing letter or figures on any surface with
black japan paint (stops, comas, hyphens and
29 the like not to be measured and paid for 30.00 3.18
separately) (i) Block (Letters/Figures) (Per
Letter pet CM.HT)
Providing throating or plaster strip / ghishi and
moulding as instructed by Engineer in charge.
Providing in line level plumb, fabricating and
fixing three row horizontal barbed wire fencing
and punched tape concertina coil of 9 turns per
meter of 610 mm diameter fixied with clips on
top of the angle iron posts. The punched tape
concertina coil having sharp barbs at every
mm spacing shall be 0.5 mm thick and 19 mm
width and weighting 13 Kg./100 mtr. (Average)
as per manufacture's specification. The rate
shall also include providing and fixed 1.20 mt.
total long MS angle 40 x 40 x 6 mm @ 3.00 mt.
c/c spacing embedded in RCC column, angle
posts shall be painted with one coats of red
oxide and two coats of enamel paint of
approved quality at top of compound wall.
Supplying, fabricating and embedding M.S.
anchor bolts, channels, angles, chequered
plates all other type of Structural Steel in
concrete members during concreting as per
drawings and instructions in all positions and at
any level including keeping them in correct
position and alignment, including adjustment of
reinforcement and shuttering, etc complete and
including two coats of approved oil paint over
red oxide primer of exposed surfaces for above
mentioned inserts after embedment, etc. all as
specified.2.2 m height and 6 m wide main
wicket gate or as per drg. and Toilet Block
White washing with lime on wall surface (two
coats) to give an even shade including
thoroughly booming the surface to remove all
dirt, dust; mortar drops and other foreign matter
Providing and laying broken Chine Mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
Cement mortar 1:3 to plain or slope and to be
34 tempered to bring mortar crème out upto 470.00 747.29 Sq.mt
surface using white cement including rounding
of junctions and extending them upto 15 cm.
along the wall, clearing with water and oxalic
acid etc. as directed.
Applying two coats of Birla (white cement
based) or Asian (acryliclapy putty) or
equivalent & two coats of primer of approved
brand and manufacture on new wall surface to
give an even shade including thoroughly
brushing the surface free from mortar dropping
and other foreign matte rand sand papered
Distempering (two coats) with oil bound
distemper of approved brand and manufacture
and of required shade on undecorated wall
surface to give an even shade, over and
including a priming coat with distemper primer
of approved brand and manufacturer after
thoroughly brushing the surface free from
mortar dropping and other foreign matter also
including preparing the surface even and sand
papered smooth.
Finishing wall with weather proof exterior
emulsion paint on wall surface (two coats) to
give an required shape even shade after
thoroughly brushing the surface to remove all
dirt and remains of loose powdered materials.
Providing and fixing wash down watercloset
(Europeantype,W.C.Pan) with integral Por S
trap including jointing the trap with soil pipei n
Cement Mortar1:1(1-Cement:1-fine sand) (Seal
38 and cover to beme asured and paid for 1.00 1894.44 No
separately) (A)vitreous China Pattern :(i) in
32 dia. C. P. brass half turn flush cock complete
including earthwork, bed concrete of 1:4:8.
Providing and fixing flat back white colour
vitreous china wash basin 550 mm x 400 mm
size with CI brackets painted white. Wash basin
shall have 15 mm dia GI supply pipe, overflow
chase, 15 mm dia pillar cock and stop cock with
PVC bottle trap and PVC pipe piece upto wall
39 plus 32 mm dia PVC waste pipe upto floor level 1.00 2105.55 No
connected to 32 mm dia CI pipe below floor and
connected to nearby floor trap complete with
unions and plumber's white soldered joints with
necessary cleaning eye, complete. All chases
cut in wall for fixing pipes shall be made good
Providing and fixing Flat Back Urinal (
Hindware- 44cmx31.5cmx26.5cm) or
equivalent approved and of approved shade
including fixing the same in concealed CI
40 brackets, CP spreader, CP dome shaped waste 1.00 1550.99 No
coupling, CP bottle trap with flanges, CP angle
cock flush pipe making inlet and out let
connections all complete as per the instruction
of Engineer - In - Charge
Providing, laying and jointing in true line and
level U.P.V.C. Pipe (SCH-40) for including
fittings make PRINCE / SUPREME / ASTRAL
/ FINOLEX or equivalent as approved by
Engineer In Charge. Pipe shall be fixed on the
wall with the help of clamp at every two metre
C/C or shall be concelled as directed including
necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing & fixing gun metal check or non
return full way wheel valve -
Providing and fixing brass screw down stop tap.
Providing and fixing screw down bib taps of
following size.(C)Gun metal screw down bib
tap. i) 15mm dia.
Providing and fixing 150 mm x 100 mm
45 intercepting sewer trap embedded in concrete 2.00 976.00 No
complete including excavation and backfilling.
Constructing Manhole with R.C.C. top slab in
1:2:4 mix (1-cement: 2-coarses and :4- graded
stone aggregate 20 mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand : 6-Brick bats 40+50 mm size)
inside plastering 15 mm thick with Cement
Mortar 1:5 (1-Cement : 5-coarse sand)finished
with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-
Cement: 2-Coarses and : 4-stone aggregate
mm nominal size) finished smooth complete
46 including curing and festing (i) Inside size 1.00 11427.16 No
900mm x 1200 mm and 2.0 M. deep including
C.I. cover with frame size 560mm diameter
total weight of cover and frame to be not less
than 128kgs. (Wt. of cover 64Kg. and Wt. of
frame 64Kg.) (A) With 230 mm thick walls of
brick msonry using brick having crushing
strength not less than 35Kg./Sq.cm. in Cement
Mortar 1:5 (1-Cement : 5-Coarse sand) (1) A
type depth 0.90 Metre for 150 mm diameter
Providing and fixing in position PVC vent pipes
of 160 mm dia 3 m length.
Providing and fixing cast iron (Spun) Nahni
trap of the following nominal diameter of self
cleaning design with C.I. screaed down or
hinged grating including cost of cutting and
making good the walls and floor 100mm inlet
and 50mm outlet. (C) 100mm dia.
Providing and fixing S.W. gully trap with C.I.
grating brick masonry chamber and water tight
C. I. cover with frame of 300 mm x 300 mm
size (inside) with standard weight. (i) Square
mouth traps.(B) 150mm x 100mm size P or R
Providing and fixing100mm size P or S trap for
water closet squatting pan including jointing the
trap with the pan and soil pipe in cement
Mortar1:1 (1-Cement : 1-Fine sand) (A)
Vitreous China.
Providing and laying (to level or slopes) and
jointing with stiff mixture of Cement Mortar in
proportion 1:1 Selt glazed stone ware pipes
including testing of pipes and joints
complete.(B)150mm dia. (upto 10 ton)
Constructing brick masonry chamber for under
ground C.I. Inspection chamber and bends with
bricks having crushing strength not less than
35Kg.Cm 2in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23Kg.) and
Wt. of frame 15Kg.) (R.C.C. top slab e with
1:2:4 mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete. (ii) Inside dimensions
500mmx700mm and 450mm deep for pipe line
with one or two inlets. (upto 10 ton)
Providing erecting and fixing double coated ISI
water tank of required capacity each with all
necessary fittings and connection etc. complete
Providing and fixing 600mm x 450mm bevelled
edge mirror of superior glass mounted on 6mm
54 thick A.C sheet or plywood sheet and fixed to 1.00 833.73 No
wooden plugs with C.P brasss crews and
Providing and laying white glazed tiles 6 mm
thick in flooring, treads of steps,walls and
55 landing laid on a bed of 12 mm thick cement 22.42 917.25 Sq.m
mortar 1:3 (1 cement : 3 coarse sand) finishing
with flush pointing in white cement.
Constructing Slab type M.H. Chamber of the
following size including excavation, refilling,
brick bats cement concrete (1:5:10) of thickness
15 C.M., CC Channel (1:2:4) of thickness
C.M., finished 15 mm thick cement plaster
inside & outside (Only for shaft) in CM 1:3,
finishing with cement slurry, P/F 4 mm dia
M.S.Steel HDPE coated steps 35 cm c/c at
cm staggered in masonary CM 1:5, RCC Slab
in CC 1:1.5:3 of thickness 23 C.M., including
Cantering & reinforcement (double jalli at
C.M. c/c bothway 12 mm dia.) but excluding
the cost of machine hole seat cover
etc..completed. of Size 1.00 X 1.40 meter
(Inside Clear,M.H. length should be parallel to
the flow, for pipe dia <= 800 mm) 1.00 to
meter depth, (Slab at Ground level) for
Rainwater Collection Chamber
Constructing Chamber of following size
including excavation, refilling, BBCC (1:5:10)
for foundation, C.C.Channel (1:2:4), finished
15 mm thick cement plaster inside in CM 1:3,
finishing with cement slurry, Brick masonary in
CM 1:5 & excluding the cost of chamber seat
cover etc..completed.
0.60 X 0.45 mt. size Inside Clear, Depth from
0.0 to 0.90meter for pipe dia <=150 mm.
chamber for dewatering
Providing & Fixing F.R.C. MH seat cover incl.
carting to the work site etc. comp. Directed.
(Based on rate of central store) FRC medium
duty Chamber seat cover (FRC) cover 706 x
556 x 50 mm rectangular cover frame size
x 450 mm clear opening outer size 816 x 666 x
100 mm (MD-10) cover for dewatering
Providing F.R.C. MH seat cover incl. carting to
the work site etc. comp. Directed. (Based on
rate of central store) F.R.C. Extra Heavy Duty
(EHD-35) machine hole Covers & Frames
Cover : 728mm ø & 100 mm thick circular
cover, 35.00 MT load design, 100x2mm MS
flat allround, 16mm ø plain round bar for lifting
the cover & should be fitted with plastic cups.
Frame : 560 mm ø clear opening, outer size-
888x888x175 mm. On the upper periphery of
frame 25 x 3 mm wide MS flat should be well
embed in concrete to protect the edges of frame.
FRC E.H.D.-35 machine hole cover & frame
described as above
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be -
well repaired as per instructions. etc..complete.
(Based on Drainage SOR 2009-10)
connection for dewatering
a) 150 mm to 300 mm dia. 2.00 1352.68 No
b) 400 mm to 600 mm dia. 2.00 2254.46 No
c) 700 mm to 900 mm dia 2.00 3156.25 No
Kota stone in Jams and Sills of the window and
61 ventilation and Door with one molding as 50.00 1107.00 Smt
directed by Engineer-in-charge.
Providing and fixing window having extruded
aluminum Colour anodized section frame main
outer size 95mm x 24mm x 1.17 mm (of Jindal
62 Section no : 2459 @ wt. of 0.738 Kg/mt), 60.00 1583.95 Smt
horizontal Three track member size 92mm x
31.75 mm x 1.30 mm (of Jindal Section no.
8688, @ Wt. 1.07 Kg/mt), vertical member of
size 92mm x 31.75mm x 1.50 mm (of Jindal
Section no. 8933, @ Wt. 1.06 Kg/mt.) with
sliding shutters of horizontal member size
40mm x 18mm x .29 mm (of Jindal section no.
8947 @ wt. 0.456 Kg/mt.) vertical member of
size 40mm x 18mm x 1.29mm (of Jindal
Section no. 8949 @ wt. of 0.456 Kg/mt with
mm thick transparent bronze colour tinted float
glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass
fixing to frame as per details etc. PH Window
and LT room Windows
Providing and fixing standared extruded of
alluminimum section of size 63mm x 38.10mm
x 1.2mm (Jindal Section : 2434, @ Wt.
Kg/mt.) with colour powder coated alluminium
frame for ventilation with 5 mm thick frosted
glass as details etc complete for Ventilation
Providing & fixing in position aluminium grill
with 15 micron natural matt brush finish
anodised as per over all size shown on the
drawings and aluminium sections of approved
make conforming to IS:733 and IS : 1285, made
out of DG - 104 design ( Jindal or equivivelent
) fixed with required size F channel, rawl plugs
and screws or with fixing clips, or with
expansion hold esters including necessary
filling up of gaps at junctions, at top, bottom
and sides with required PVC/neoprene felt etc.
and aluminium snap beading for glazing /
panelling, C. P.brass/stainless steel screws,
including standard anodised aluminium fittings
and fixtures of approved make and of adequate
size and in adequate numbers, including cost
and fixing of fixtures etc. complete as per
detailed drawings with all lead and lifts.
Providing upto floor two level precast cement
concrete jali or grill 1:2:4 mix (1- Cement : 2-
coarse sand : 4-graded stone aggregate 6mm
65 nominal size) reinforced with 1.6 mm dia. Mild 25.00 646.60 Smt
steel wire including roughening,cleaning,
fixing and finishing in cement mortar 1:3 and
curing complete. (B) 40mm thick
Supplying, fixing Push and Pull, 20 gauge
rolling shutter of approved make for the sizes
indicated on drawings including hood cover,
channel sliding assembly, helical coil springs,
66 brackets, interlocking latches, locking 40.00 4277.00 Smt
arrangements, painting with 2 coats of enamel
paint over one coat of approved primer paint
etc. complete. Shutters having width below
3.5M (gear Operated)
Providing and laying cement concrete flooring
1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) including water
proofing compound finishing with a floating of
neat cement slurry etc. complete laid in one
layer finished including necessary curing at
bottom of sump.
Average 50 mm thick
Providing and laying polished Kota stone slab
flooring over 20 mm (average) thick base of
cement mortar 1:6 (1 cement : 6 coarse sand)
laid over and jointed with grey cement slurry
including rubbing and polishing etc. 30 mm
Providing and laying polished Kota stone slab
25 mm thick in riser of steps, skirting Dedo &
pillars laid on 10 mm thick cement mortar 1:3
(1 cement : 3 coarse sand) and jointed with grey
cement slurry including rubbing and polishing
Providing and fixing 40mm dia. GI pipe
medium weight quality as openable type with
angle iron support at 1.5 m c/c using 75 x 75 x
10 mm angles, 1 m long with three rows of
pipes as railing including necessary painting
with two coats of approved quality oil paint
over one coat of approved primer including
necessary welding, bolting required, if any.
Painting two coats including priming coat on
new steel & other metal surfaces with enamel
71 paint, brushing, interior to give an even shade 105.00 122.49 Smt
including cleaning the surface of all dirt, dust,
other foreign matter.
Providing, Fabricating & fixing WDS name
board of Size 3.00mX0.60 made from ISA
50X50X5 mm M.S angle with 3 Nos supports
at back side vertical member of angle size 1.1m
ht incl 0.3 m hold fast inserted in compound
wall with necessary dismantling and fixing with
cement concrete. The rate shall also incl 16 g
M.S sheet of size 3.00X0.60 mt incl ACP Sheet
with Printing letter with AMC logo as directed
by EIC. rate shall incl painting board with
coat of enamal paint over one coat of anti-
corrosive primer.
Providing, Fabricating & fixing caution board
of size 1.50m x 0.60m made from ISA 40 x
x 5 mm MS angle with 2 nos. supports at back
73 side vertical member of of angle size 1.10m 7900.00 No.
height (inclu. 0.30m hold fast inserted in
compound wall with necessary dis-mantling
and fixing with cement concrete. The rate shall
also include 14g MS sheet of size 1.50mt x
0.60mt incl ACP Sheet with Printing letter with
logo as directed by EIC. rate shall incl painting
board with 2 coat of enamal paint over one coat
of anti-corrosive primer.
Providing and fixing Radium sign board of size
3.00mt x 0.60 mt made from ACP sheet with
74 writing coloured reflected letter of WDS name 7400.00 Nos.
board with necessary clamp for hanging board
at pump house etc. comp as directed by EIC
Removing any kind of pavement incl stacking
75 of serviceble material disposal of unserviceble 1500.00 14.00 Smt
material with 50 meter lead and lift.
Labour work for fixing interlocking blocks /
any kind of pavement on up to 50 mm th sand
76 bedding, levelling, watering and fixing in line 70.34 Smt
& level as well cleaning the site with all lead
etc.comp. as directed.
Providing and fixing smooth surfaces,
homogeneous, best quality 10 mm thick clay
tiles of approved make, colour and shade on a
77 10 mm (1:3) thick cement plaster including 2 673.00 Smt
coats of apex paint around Pump house,
Chlorine room, Stair cabin, Toilet block and
H.T AEC room etc.
Grouting with 1:3 cement, sand mortar for
anchor bolt pockets, machine bases, pipe
78 sleeves, pockets holes, etc. including 4536.00 Cmt
roughening and cleaning of concrete surfaces,
curing, etc. complete.
79 Drilling holes for grouting -
Drilling 40 mm Dia. Holes in masonry/concrete
structures with providing and fixing 500 mm
long GI Pipeline for pressure grouting including 458.04 Rmt
supply of material, machineries and labour cost
80 Making 15 mm groove in RCC work on road
and finished it good incl. all labour charges etc 30.00 Rmt
comp as directed.
81 Constructing Bombay Pattern Type Catch Pit of
size 0.60 x 0.60 depth up to 1 mt including
excavation, B.B.C.C. (1:5:10), 23 cms thick
brick maso. wall in the prop. of CM (1:6) with
40 mm thick IPS flooring in the prop M15 at 3156.25 Nos
bottom and 15 mm thick cement plaster inside
the catch pit in the proportion of CM (1:3) with
out jali etc. comp. as directed. (As per R.A.
Based on Building SOR 2015-16)
82 Catch Pit Jali Fixing P/F FRC catch pit jali with
frame 600mm x 600mm clear opening etc.
comp.. As directed by engineer in charge.
(Based on Central Store Rate)
83 Providing and fixing in position 6.0 m high
aluminium water level indicator made of
mm width and 4 mm thick aluminium sheet
fixed on angle 50 X 50 X 6 mm frame and 10627.00 Nos
bracing and fixing in concrete base as per
specification or as directed by Engineer-
84 Providing and supplying lSI Standard R.C.C.
pipes(of Sulphate Resisting Cement) in
standard lengths of following class and
diameter suitable for either collar joints or
rubber ring joints including all taxes. insurance.
transportation. freight charges. octroi,
inspection charges, loading , unloading,
conveyance to departmental stores, stocking
Note: One collar should be supplied with
each full length plain ended RCC pipe, cost
included in rates below. One rubber ring
should be supplied with each full length
socketed pipe, cost included in rates below.
(a) 300 mm dia.
85 Providing and laying Trimix with dewatering
machine and floater machine on constructed
RCC work including cost of machine and
labour etc. compact directed .
86 Providing And Jointing Stoneware Pipes Incl.
Excavation Up to 2 Mt. Refilling, Transporting
Pipes To Work Site, Unloading, Lowering In
Trench, jointing material Such As Cement,
sand, Hemp Bitumen As Directed, Incl.
Watering The Trenches Spreading And Carting
away Of Surplus material as directed by
engineer in charge.
87 Fixing of Rebar on concrete structure for
connection with new structure using
Hilti/Fischer or equivalent technology -
including all labour, tools & tackels temporary
arrangement, safety meaasures etc. complete.
10 mm dia. Bar 50.00 351.00 Nos
12 mm dia. Bar 75.00 420.00 Nos
16 mm dia. Bar 75.00 490.00 Nos
20 mm dia. Bar 25.00 560.00 Nos
88 Providing and supplying in standard length ISI
mark rigid unplasticised PVC pipes suitable for
potable water with ring fit joint including cost
of rings, as per IS specification no. 4985/1988
including all local and central taxes,
transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to the departmental stores and
including cost of jointing meterial etc. -
Note:One coupler / ring shall be provided
with each full length pipe cost of which is
included in rates below.
3% (Three) Discounted rate to be consider
for Coupler jointed pipe
Test Pressure 10 Kg/cm2.
89 Lowering, layi ng, fixing and jointing
PVC/uPVC/cPVC pipes and specials of
following class and diameter including cost of
conveyance from stores to site of works -
including cost of labour, material, cement
solvent, giving satisfactory hydraulic testing as
Name Augmentation and SITC of Pumping Machinery with Related Mechanical, Electrical and Instrumentation Work For Baldevnagar
of water Distribution station at South West Zone of Ahmedabad Municipal Corporation (AMC).
MECHANICAL WORK
Sr. Total Amount
Sr. Total Amount
Item Qty Unit Unit Rate
1.1.1 SUBMERGED CENTRIFUGAL PUMPSETS 2 Nos. 13,91,040.00
SITC Submerged centrifugal pumpsets(water immersed, dry air filled, class "F"
insulated TEWC motor integrally mounted on volute casing pumpsets for water
duty, 3-phase, 50Hz±3%,415V±10% along with suitable foundation/ installation
device with cable length from pumps to panels & of following Material of
Impeller- SS CF8M, Casing-C.I. FG 260, Wearing Ring -SS, TC mechanical seal,
CS/S.S.bearing, S.S shaft with sleeve, SS strainer & MS motor body. & with 25Mt.
length round submersible Power & control cable, (25m, 4 core round copper
conductor, PVC insulated power cable of reqd size & 1.5 sq. mm control cables of
required core for each pump motor set) with necessary electrical termination
connection at junction box / starter panel and precast foundation blocks for auto
coupling & delivery bend, guide pipe etc. as per the specification / IS. Also
including in scope any other parts / accessories / fittings requried to complete the
work in all respects & satisfactory operation of pump set.
Capacity SCF Pump: 625 m³/hr.
Motor Rating: 110 KW (or higher as per pump manufacturer reco.)
Supply, installation, testing and commissioning of Manually gear operated CI/DI
Double Flanged, Rising Spindle type, Sluice Valve, integral starter,etc.
conforming to IS 14846 PN 1.0 with SS 304 seat rings and SS spindle with all hot
dipped galvanised hardware's, bolts, nuts & washers, gaskets, etc. as per data sheet.
Size : 100 mm NB (Manually Operated - On Header Drain Pipe )
2.2.1 VALVES 2 Nos. 26,212.00
Supply, installation, testing and commissioning of Manually gear operated CI/DI
Double Flanged, Rising Spindle type, Sluice Valve, integral starter,etc. conforming
to IS 14846 PN 1.0 with SS 304 seat rings and SS spindle with all hot dipped
galvanised hardware's, bolts, nuts & washers, gaskets, etc. as per data sheet.
Size :300 mm NB (Manually Gear Operated - Delivery of SCF pump)
2.3.1 Supply, installation, testing and commissioning of double flanged CI/DI Dual 2 Nos. 37,587.00
Plate Check Valve conforming to API 594 Class 300 / PN 1.6 with CS dual door,
hinge pin & stop pin of SS 410 , springs of AISI 304 and seat rings of SS 304 (
renewable ), along with all required accessories, gaskets and hardwares,etc. and as
per specification.
Size : 300 mm NB (On Delivery of SCF pump)
2.4.1 Supply, installation, testing and commissioning of Electrically & gear operated 1 Nos. 1,67,945.00
CI/DI DF Butterfly Valve, conforming to IS 13095 / BS EN 593, PN 1.0 with SS
304 renewable seat rings , indicator, gear box with bolts, nuts & washers, gaskets,
etc. as per specifications.
Size: 300 mm NB (Elec. Operated on Header Pipe after Flowmeter)
2.5.1 SITC of CI/DI Tempor proof Flanged Air Valve with Isolation Sluice Valve as 1 Nos. 11,600.00
per IS 14845 PN-1.0 & IS-14846 PN-1.0 respectively with SS304 float, gun metal
nozzle, complete hardware's, bolts, nuts & washers, gaskets etc. including all taxes,
Insurance, Transportation, freight charges, Inspection charges, loading, unloading,
conveyance to departmental stores, stacking, security etc. as per IS and
Size: 50 mm NB - Pn 1.0 (On Header line)
3.1.1 C.I. PIPES & SPECIALS 2000 kg 58.00
Manufacture, Supply and delivery of CI flange ended Pipes complete as per IS
1536 / 1537, Class B or its latest revision for various dia meter and classes The
delivery of pipes to be made to Pump house/site including all taxes , loading
carting, unloading, stacking, insurance, octroi, inspection charges etc. complete as
per IS and as per specifications.
Size : 200 mm NB and Above ( For Delivery side)
3.1.2 Labour Charge of CI flange ended Pipes complete as per IS 1536 / 1537, Class B 2000 kg 11.00
or its latest revision for various dia meter and classes The delivery of pipes to be
made to Pump house/site including all taxes , loading carting, unloading, stacking,
insurance, octroi, inspection charges etc. complete as per IS and as per
specifications.
Size : 200 mm NB and Above ( For Delivery side)
3.2.1 CI FITTING & SPECIALS 503 kg 58.00
Supply of delivery , header , testing and commistioning of Flanged CI fittings and
specials like 90 deg, bend, Blind Flanges, Reducer/ Expander, Duck Foot Bend,
TEE etc, conforming to IS 1538 and complete in all respect.
Size : 200 mm NB and Above ( For Delivery side)
3.2.2 Labour Charge of delivery , header , testing and commistioning of Flanged CI 502 Kg 11.00
fittings and specials like 90 deg, bend, Blind Flanges, Reducer/ Expander, Duck
Foot Bend, TEE etc, conforming to IS 1538 and complete in all respect.
Size : 200 mm NB and Above ( For Delivery side)
3.3.1 Supply and installation of CI Blind flange conforming to IS- 1538 with gaskets, 1 Nos. 1,856.00
hardware and required accessories as per specifications.
Size : 300 mm (Blind) - On Main Header end
3.4.1 Supply, installation, testing and commissioning of double flanged Expansion 3 Nos. 10,200.00
Bellows confirming to EJMA/IS standard with PN 1.0 rating & all necessary St.St.
Size : 300 mm x 300 mm ( L ) (On Delivery of Each Pump and Header pipe)
3.5.1 Flanged Joints of Pipes, Fittings and Specials: 4 Nos. 434.00
Supply, Installation, Making of IS 1538 Flanged CI & GI Pipes, Fittings and
Specials Joints with all jointing materials, rubber packing, nut bolts, labour etc.for
complete connection.
Size: 50 mm dia
3.5.2 Size: 100 mm dia (For Header Drain Pipe ) 4 Nos. 477.00
3.5.3 Size: 300 mm dia (Each Pump Del. Flange and Header Flanges) 30 Nos. 1,223.00
3.6.1 M.S. PIPES & SPECIALS 50 RMT 3,106.00
Supply, Gas cutting of pipe, Fabrication, welding, Installation, testing and
commissioning of MS pipe & Specials etc. conforming to IS 3589 & flanges
confirming to IS 6392-PN-1.0, fabricated from MS. plate with necessary supports
& anchoring. Pipe fabricated from MS plate. (Excluding supply of flange)
Size: 300 mm NB X 5.6 mm Thk
3.7.1 MS FITTINGS & SPECIALS: 200 kg 70.67
Supply, Fabrication, Gas cutting of pipe, welding, Installation, testing and
commissioning of MS flanged / plain ended specials and fittings like MS reducer,
expander, Metering bends, Tees, etc. conforming to IS 3589, flanges confirming
to IS 6392-PN- 1.0, fabricated from MS. plate with necessary supports &
anchoring. Pipe fabricated from MS plate. (Excluding supply of flange)
Size: 300 mm NB mm x 5.6 mm Thk
The scope also includes civil work, casting PCC thrust block, chipping, grouting,
supporting,etc. require for laying & connecting the MS pipes & fittings as require
outside the pump house
4.1.1 Supply, welding , Installation, testing & commissioning of MS flat machined 2 Nos. 1,074.00
faced flanges confirming to IS 6392 & drilled as per IS-1538 with drilling off
centre bolt holes and flange thickness as per PN 1.0 including cutting &
welding.Provide as per Actual Site Requirements.Size : 50 mm NB Drilled (For
Air Valve Piping On Header Pipe)
4.1.2 Size : 100 mm NB Drilled ( For Header Drain Valve on Header Pipe) 2 Nos. 1,242.00
4.1.3 Size: 300 mm NB Drilled ( For Pump Delivery Pipe and Header Pipe ) 20 Nos. 3,931.00
4.1.4 Size: 300 mm NB Drilled( Blind Flange For SCF Pump Header) 1 Nos. 4,253.00
5.1.1 G.I. PIPES & FITTINGS: 5 RMT 387.00
Supply, installation, connection with equipments as required, testing and
commissioning of GI pipe conforming to IS-1239 , Medium Duty with coupling,
tee, bend, union, elbow, flanges , etc as all required fittings for connection
complete with gaskets, hardware, and required accessories as per IS &
Size: 50 mm NB(on Header for Air Valve Piping & Header Drain Piping)
6.1.1 Supplying & Fixing SMC Chequered plate having 10 mm thickness, made out of 10 Sq. 4,493.00
SMC Confirming to IS 13410 & by Hot press Compression Moulding technique Mtr.
Suitable cut & fixed with MS Angle Frame to Fit Trench Widths as per site
requirement approved by engineer incharge. Provide as per Actual Site
7.1.1 Manual Chain Hoist With H.O.T. 1 Nos. 35,520.00
SITC of Manually operated Spur Gear travelling trolley suitable to monorail
girder with manual hand operated Chain Hoist, lifting hook, load chain, hand
chain & locking device, suitable for vertical lifting/ lowering and manufactured
as per IS: 3832 - 2005-Class-M4, complete with chain hoist, chain-gear, safety
device and all other required accessories like fasteneres, epoxy painting, etc. and
tested to 25% over load complete as per specifications and complete in all
Cap : min. 3 Ton. ( Above Ex. Sump for lowering / Lifting for SCF Pump )
Lift : 15.00 mtr as Mini. Or as per Site Requirement.
Length of Hand chain : 10.00 mtr Or as per Site Requirement
7.2.1 Construction of Shed : 10 Sq. 216.10
1.80 mm FRP sheet used for Construction of Shed for Electric Chain Hoist and Mtr.
Pump. Shad size and installation location should be as per instruction given by
Engineer In-Charge.
8.1.1 Providing and Supplying at site of work with M.S. anchor bolts, channels, angles, 1500 kg 72.91
chequered plates, all other type of inserts, ladder, ISMB etc. in concrete members
during concreting as per instructions in all positions and at any level including
keeping them in correct position and alignment, including adjustment of
reinforcement and shuttering, etc. complete and including two coats of approved
oil paint over one coat of zinc-rich primer over exposed surfaces of above
mentioned inserts after embedment, etc. all as specified."Providing and
Supplying at site of work with M.S. anchor bolts, channels, angles, chequered
plates (12mm thick), all other type of inserts, ladder, ISMB etc. in concrete
members during concreting as per instructions in all positions and at any level
including keeping them in correct position and alignment, including adjustment of
reinforcement and shuttering, etc. complete and including two coats of approved
oil paint over one coat of zinc-rich primer over exposed surfaces of above
mentioned inserts after embedment, etc. all as specified. (min. 250 mm I-Beam
gireder for Vertical & Horinzontal column, for Monorail etc. as required to
complete the work in all respects & satisfactory operation of Electric Chain Hoist)
For Construction of monorail girder for Chain Pulley Block with all required
accessories and hardware and as per instruction given by Engineer In-
8.1.2 Labor Charges for lowering,laying,fixing with fabrication at site with M.S. anchor 1500 kg 11.37
bolts, channels, angles, chequered plates, all other type of inserts, ladder, ISMB
etc. in concrete members during concreting as per instructions in all positions and
at any level including keeping them in correct position and alignment, including
adjustment of reinforcement and shuttering, etc. complete and including two coats
of approved oil paint over one coat of zinc-rich primer over exposed surfaces of
above mentioned inserts after embedment, etc. all as specified. (min. 250 mm
I-Beam gireder for Vertical & Horinzontal column, for Monorail etc. as required
to complete the work in all respects & satisfactory operation of Electric Chain
Construction of monorail girder for Chain Pulley Block with all required
accessories and hardware and as per instruction given by Engineer In-
Charge.Size : 350 x
9.1.1 CHLORINATION SYSTEM 4 Plant 2,10,642.00
SITC of wall mounted, FRP cabinet type, Vacuum operated Chlorination plants
with required piping, fitting, valves, safety and testing kit, etc. Complete
arrangement shall be as per attached standard drawing for one complete system
combining the Two plants complete in all respect as per IS and as per specification.
(Without Chlorine Cylinder).
Capacity: 5 kg/hr. for each plant making one complete plant as per attached
standard drawing and shall include the followings:
(1) 1 No. Submersible Pump motor set with continuous Cable from pump to starter
panel without any Joint with proper conduit piping and clamping. (2) 1 No.
Diffusers, (3) 1 No. Ejector, (4) 1 No Chlorinator , (5) 1 No. Vacuum Regulators,
(6) 1 No. Strainer , (7) 5 Nos. Isolation Ball Valves , (8) 1 Non Return Valve, (9)
1 Nos. Yoke clamp (for cylinder), (10) 1 No. Pressure Gauge with require piping
and isolation valve, (11) 1 No. Chlorine Gauge at Cl2 manifold (12) 1 Lot of piping,
fittings, valves & instruments, (13) Vaccum Gauge , 14) MS support of 50 mm x
50 mm x 4 mm thk, (15) 3C copper armour power cable from PMCC panel to
Chlorine room of required size with proper piping & Clamping as equired., (16) 1-
lot inter connecting piping of identical pipe size of Cl2 booster pumps delivery line
with isolation valve, (17) 1 No. common Starter panel with TPNB MCB with
necessary cabling & electrical connections etc. and other necessary items as per IS
& Tender Specification and Data sheet for Cl2 booster pumps, (18) 1 no common
3/4" Cl2 gas manifold of Carbon steel suitable for two cylinder.
(2 Nos. Chlorination Plant Installation at other WDS as per Instructed by E-
9.1.2 Supply of safety kit & testing as specified in the specifications. 1 Set 83,241.00
(1) 1 Set Chloroscope
(2) 1 set. Air breathing apparatus for 45 min as per IS with O2 bottle,
(3) 1 set. Emergency tool kit
(4) 1 No. Amonia Torch
9.1.3 TRAY FOR CHLORINE SOLUTION uPVC PIPES 100 RMT 357.00
Providing & Fixing approved make Perforated C type tray made from CR sheet
along with required accessories to sustain the weight of uPVC pipe with bends,
tees and clamps for fixing of uPVC pipe and all the fittings as required as per site
condition. The Perorated type tray shall be single or double needed as per required
and as per IS 2062/1079 and shall be coated with hot deep galvanised as per IS
2629/4759 with coupler plate/Fish plate and GI hardware like nut-bolt and washers,
etc. erected providing support as per specification and as per instruction of E-I-C.
Size: 100 x 50 x 1.5 mm thk
10.1.1 MISCELLANEOUS:Providing, Supply of Structure Steel at site of work with 478.5 kg 64.83
freight, loading, unloading carting, etc. including all taxes and duties complete such
as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat, Plates,
Chequered plates (below 10mm thickness) etc. required for support structure of
Elecrto-Mechanical equipments etc. for support on floor / wall / beam / brackets
etc. as per tender and IS.
10.1.2 Labour Charges for lowering, laying, Fixing with fabrication various size section 478.5 kg 11.36
of MS such as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat,
Plates, Chequered plates etc Complete with two coats of red oxide and two coats
of approved colour shade of epoxy paint as per relevant IS and as per specification.
TOTAL ESTIMATE OF MECHANICAL WORK (Without GST)
Name Augmentation and SITC of Pumping Machinery with Related Mechanical, Electrical and Instrumentation Work For
of Baldevnagar water Distribution station at South West Zone of Ahmedabad Municipal Corporation (AMC).
INSTRUMENTATION WORK
Item Qty Unit Unit Rate Amount
1.1.1 PRESSURE MEASURING SYSTEM 3 Nos. 1,412.00
Supply, installation, testing & commissioning of Bourden type Pressure Guage
glycerene filled having 150 mm dial with necessary fittings/accessories (Manifold
valve, nipples, etc. shall be in SS 316 only) as per specifications & complete in all
Range : 0 - 6 kg / sq.cm.
( Delivery Side of each Pump, 01 No. for Header Pipe).
1.1.2 Supply, installation, testing and commissioning of Digital Pressure Transmitter along 3 Nos. 29,147.00
with, manifold valve, required fittings, tubing (all valves, fittings, tubings, etc. shall be
in SS 316 only) all accessories, hardware, etc. complete in all respects as per
specifications and having following measurement ranges:
Range : 0 - 6 Kg/cm² (On Delivery of Side of Each Pump, 1 No. Header Pipe)
2.1.1 LEVEL MEASURING SYSTEM 1 Nos. 59,436.00
Supply, installation, testing and commissioning of Ultrasonic type Level Transmitter
along with all required accessories with Large Display, hardware, hardware, etc.
complete in all respects with local and remote display, as per specification. The scope
also includes providing 4" flanged , puddle pipe approximate 300 mm long including
fixing of the same in civil structure slabe of pump house for mounting of level
Transmitter. The work also include all necessary work like make hole, repair /
modification in existing slab, etc. Level Transmitter having following measurement
ranges for liquid (Water) application:
Meas. Range: upto 6 m For Sump (OR as per Actual depth as per site requirement)
2.1.2 Supply, installation, testing and commissioning of Float type Level Switch along with 1 Nos. 12,802.00
10 mtr. Cable and WP Junction Box (at wet well for dry run protection of pumps)
complete in all respects and as per specification.The scope also includes providing 4"
flanged , puddle pipe approximate 300 mm long including fixing of the same in civil
structure slabe of pump house for mounting of level switch.The work also include all
necessary work like make hole,repair / modificationin existing slab, etc.
Meas. Range: upto 6 m For ESR (OR as per Actual depth as per site requirement)
2.1.3 Supply, installation, testing & commissioning of Float & Board type level indicator 1 Nos. 17,718.00
along with all accessories, hardware, etc.
complete in all respects as per specifications and having following measurement ranges:
Meas. Range: upto 6 m for Sump (OR as per Actual depth as per site requirement)
3.1.1 ELECTRO MAGNETIC FLOW METER 1 Nos. 1,34,422.00
Supply, installation, testing and commissioning of remote type Full Bore
Electromagnetic flow meter comprising of IP-68 Sensor, IP-65/66 remote transmitter
with 10m cable between sensor and transmitter,Panel mounted flow indicator cum
Totalizer along with all mounting accessories, hardware, etc. complete in all respect and
as per specs and shall have following size and measurement range. The scope also
includes necessary connection with header pipe.
Meter Size : 300 mm For Header
Pipe size: 300 mm
Pipe Material : C.I. / M.S.
3.2.1 HOOKUP WITH EXISTING PLC PANEL 1 Job 50,000.00
Hookup of New Proposed Pump, MFM, PT, LT, Large Display, MOV,etc. with existing
PLC Panel shall be carried out by success full bidder and AMC shall be arrange to
provide the access in Existing PLC Panel to succesfull bidder for data hook of Proposed
items andprogramming in PLC for auto operation of pump as per instruction of Client/
4.1.1 INSTRUMENT CABLE & ACCESSORIES 100 MTR 147.00
'Supply, Laying, Installation, Connection, Termination, Testing & Commissioning of
Instrument Cables, along with cable glands, lugs, cable trays, required junction boxes,
fittings and accessores as per specs.
The unit rate shall include
a. Supply, loading & unloading of the cable at site from store.
B. Shifitng of cable from site store to place of installation.
c. Fixing of cable clamps, brackets, supports, route markers etc. where ever required to
fix the cables safely.
d. Excavation, back filling and levelling of ground alongwith laying of fine sand,
protection bricks and other necessary civil material for laying cables outside the
e Testing and submission of sketches & reports of all the cables laid.
4.1.2 CONTROL CABLE 100 MTR 128.00
4.1.3 SIGNAL CABLE 100 MTR 150.00
4.2.1 INSTRUMENT CABLE TRAY 100 MTR 302.00
GI Perorated type cable tray shall be made out of galvanized MS sheets of 2.0 mm
thickness with required asccessories . All material shall be Hot dip galvanised (816
g/m2) as per IS 2629 as mentioned in specification and tray hardware shall be in GI.
50 x 25 mm - Perforated type
4.3.1 CABLE END TERMINATION AND CONNECTION 16 Nos. 151.00
'Supply, fixing, connection, testing and commissioning of double compression brass
cable glands and crimping type Bimetalic lugs / sockets with necessary tools and
equipments as specified in specifications and IS complete in all respects. The glands
and lugs / sockets shall be suitable for cable size and type mentioned above. The job
also includes earthing the glands and armour of the cable with common earth bar or
flexible copper mesh as applicable.
4.3.2 CONTROL CABLE 16 Nos. 143.00
4.3.3 SIGNAL CABLE 16 Nos. 135.00
TOTAL ESTIMATE OF INSTRUMENTATION WORK (Without GST)
Augmentation and SITC of Pumping Machinery with Related Mechanical, Electrical and Instrumentation Work For
Baldevnagar water Distribution station at South West Zone of Ahmedabad Municipal Corporation (AMC).
ELECTRICAL WORK
Item Qty. Unit Unit Rate Amount
1.1.1 Power Supply Board 1 Lot 51,828.00
TPN MCCB (For LT Service Obtaining Requirement)
SITC of 400 A TPN microprocessor MCCB (50kA) with O/L, S/C & E/F
protection with Extended rotary handle, Terminal spreader, Auxiliary change
over& Trip contact, with Outdoor Enclosure with canopy 2mm thick
Single/double door & Wall mounted/ stand mounted as per site requirement (with
incoming & outgoing cable entry at bottom )with Cable end boxes with RYB
indicating lamp, Digital voltmeter, VSS, ON,OFF & Trip indicating lamp etc as
per Power supply company requirements & location. Including all civil works
for fixing of panel on wall.
(A) 4 Pole, MCCB with Breaking Capacity of Icu=50 KA at 415V (Ics =100%
of Icu), Microprocessor release
(Wall mounted at Location as per PSC req.)
1.2.1 MCC PANEL BOARD (MCC): 1 Nos. 11,55,600.00
SITC of suitable Stand-alone MCC Panel (50kA) suitable for Manual & Auto
Operation-Local & through PLC/SCADA operation as per site conditions
complete in all respects as per SLD / Specification / IS and including following
(1) One nos. FP 320A Microprocessor MCCB for I/C with Digital Voltmeter
with Voltmeter Selector Switch, Digital Power Factor Meter, Digital Ammeter
with Ammeter selector switch, MFM with RS-485, R, Y, B, on, off, trip
Indicating lamps & ON, E-STOP, Reset Pushbutton, etc.
(2) 320 A TPN Main busbars. (Main & Auxilary bus-bars size with current
density 0.8A/Sq.mm)
(3) Two Nos. (1W+1S) Soft starter for min. 110 KW Motor or higher as per pump
manufacturer reco. with suitable derating and with 320 A TPN Motor Duty
MCCB, 250A AC3 duty line & Internal / External bypass contactor, Ten channel
temprature scanner with potential free contacts, fast acting fuse, PMU, MFM
with RS-485, door display key pad & digital MPR+SPP with CBCT, on,off,trip
Indicating lamps & ON, E-STOP, Local/Remote, Auto/ Manual selector switch
& LCS for Pump- MOV Actuator with Indication & push button etc.
(4) APFC 70 kVAR separate cubical Capacitor compartment with soft starter
Cubical Panel (Part of Soft Starter cubical) Comprising of 1 no. 125A FP
Microprocessor MCCB (50kA) with adjustable Overload and adjustable short
circuit, 7 step APFC Relay with RS-485, 125A/5A CT Cl:1.0 for Ammeter,
Digital Ammeter, ASS, A/M Switch, On delay timer, push button etc. complete
in all respects as per specification, IS & SLD.
(4.1) 1nos. 30 kVAR capacitor bank with 63A 'D' curve MCB & 30 kVAR
Capacitor duty contactor with timer.
(4.2) 1 nos. 20 kVAR capacitor bank with 40A 'D' curve MCB & 20 kVAR
Capacitor duty contactor with timer.
(4.3) 1 nos. 10 kVAR capacitor bank with 20A 'D' curve MCB & 10 kVAR
Capacitor duty contactor with timer.
(4.4) 1no. 5 kVAR capacitor bank with 16A 'D' curve MCB & 5 kVAR Capacitor
duty contactor with timer.
(4.5) 2nos. 2 kVAR capacitor bank with 16A 'D' curve MCB & 5 kVAR
Capacitor duty contactor with timer.
(4.6) 1 no. 1 kVAR capacitor bank with 16A 'D' curve MCB & 5 kVAR Capacitor
duty contactor with timer.
(4.7) All capacitors shall be Gas Filled type with dielectric losses ≤ 0.2w/kVAR.
(Suitable for 0.95 or better Correction).
(5) One nos. 63ATPN MCCB feeders (for Spare)
(6) One no.32A TPN MCCB Feeder (for Spare)
(7) 2 nos. 32A 'C' curve MCB feeders (for spare feeders)
(8) 2 nos. 16A DP MCB feeders
(9) 2 no. LCS (PBS) with 16A FP MCB, indicating lamp,Push Button, SP MCB,
etc. (for Butterfly Valve and spare)
(10)3nos. 320A/1A, Cl.-0.5 metering CT
(11)1nos. 320A/1A, Cl.-1. APFC CT
(12) 2nos. Multiplication relay for dry run protection of pumps
1.2.2 SITC of Schneider make a Soft starter for min. 180 kW Motor or higher as 2 Nos. 3,61,935.00
per pump Manufacturer reco. with suitable derating and with 400A TPN Motor
Duty MCCB, 315A AC3 Inbuilt/external bypass contactor and other all
accessories for completing the satisfactory work in contractor scope.
Note: Contractor must be verifying the Existing PMCC Panel Soft Starter
Feeder details and procure the same. is same Model not available at that
time, then provide same technical confugation of Soft starter for ease of
2.1.1 SITC of Lighting Distribution Board (LDB) as under:3 Phase 4 Wire TPN, 6 1 No. 6,502.00
way Prewired LDB (One each for Indoor & Outdoor Lighting) Suitable to house
:Incoming: 32A FP, ELMCB (30mA)Outgoing: 20A SP MCB 'C' curve (9
nos.) & 16A SP MCB 'C' curve (9 nos.)(At Panel Room)
2.1.2 SITC of Power Distribution Board (PDB) for MOV as under: 1 Nos. 9,051.00
3 Phase 4 Wire TPN, 8 way Prewired MOV-PDB for Actuator of valves power
supply (For MOV Pump delivery valves, valve at Header & spare):
Incoming: 63A TPN, MCB 'C' Curve
Outgoing: 10 nos. 32A TP MCB 'C' Curve
2.1.3 Local Control Station 2 Nos. 2,800.00
SITC of Pendant type ON_OFF (E-Stop) LCS pushbutton set complete with
Enclosure, necessary mounting/ fixing arrangement on wall / pipe support etc. to
be installed near motors for remote operation, etc. as per IS and specifications.
(Including structural steel)
(For each Pumps)
2.1.4 SITC of Local Control Station with pendant type Open_Stop_Close pushbutton 3 Nos. 4,500.00
set and with Open, Close, Trip & Local / Remote Indicating Lamps complete
with Enclouser, necessary mounting/ fixing arrangement on wall / pipe support
etc. to be installed near motors for remote operation, etc. as per IS and
specifications (including structural steel)
(For Each Actuator Pumps delivery Valves, Header)
2.1.5 SITC of stand / wall mounting type MS Junction Box, minimum 2.5mm thick, 2 Nos. 2,050.00
with detachable cable gland plate of 3mm thick, duly powder coated, with
earthing terminals, steel structure stand for mounting of JB, etc. for
Jointing/Termination suitable for 1.1 kV Submersible Flexible Copper Power
cable with Aluminium/ Copper armoured power cable from PMCC . Scope shall
include providing suitable rating AL busbars, Support
insulators, Crimping type lugs,nuts,bolts,washers etc. complete in all respects as
instructed by E.I.C. Drawing shall be got approved before SITC of the same.
Lugs of cables shall not be connected directly. (Structure steel for Stand shall be
measured separately)
JB of minimum Size: 300mm x 300mm x 75mm or higher as required. or higher
as required (for 2 nos. Pump)
3.1.1 LOW VOLTAGE (LT) CABLES 250 Mtr 783.00
Supply and unloading & delivery at site, storage & security at site of 1.1 kV,
A2XFY/2XWY XLPE insulated (IS 7098) / PVC insulated (IS 1554) AL / Cu
conductor cables as per specification & IS. The cable when laid outside the
building shall be laid underground in excavated trench, as per specified method
and shall be laid in prepared trench on cable tray when laid inside the building.
3.5C x 240 sq. mm. A2XFY Cable (1 run From Existing PMCC to PSB To MCC
3.1.2 3C x 240 sq. mm. A2XFY Cable (1 Runs for MCC Panel to SCF Pump Motor) 150 Mtr 678.00
3.1.3 4C x 6 sq. mm. A2XFY Cable (For WR-DB with TPN MCB at Sump & Pump 100 Mtr 78.00
House, ,.Each Nos. MOVPDB )
3.1.4 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For TPN MCB for Monorail EOT at 100 Mtr 81.00
Pump House, Each MOV at Main Pump and MOV at Header )
3.1.5 2C x 2.5 sq. mm. 2XWY/2XFY Cable (For Each Motor space heater(as 100 Mtr 177.00
required), for level switch
3.1.6 7C x 1.5 sq.mm. 2XWY/2XFY Cable (For Each Pump Motor LCS with Ameter,) 100 Mtr 115.00
3.1.7 10C x 1.5 sq.mm. 2XWY/2XFY Cable 100 Mtr 230.00
3.1.8 12C x 2.5 sq.mm. 2XWY/2XFY Cable (For Actuator LCS of Each Pump) 100 Mtr 393.00
3.1.9 10Tride x 1.0 sq.mm. individual triad and overall shielded with aluminum mylar 50 Mtr 460.00
tape Signal Cable for RTD & BTD of motor(For Each Main Motor)
3.2.1 CABLE END TERMINATION AND CONNECTION: 6 Nos. 860.00
SITC of Double compression Weather proof type Ni-Plated brass cable glands
and crimping type Bimetalic lugs / sockets with necessary tools and equipments
as specified in specifications and IS.
The glands and lugs / sockets shall be suitable for cable size and type mentioned
below & as per specificaitons.
1) Earthing the glands and armouring with earthing clamp and jumper and also
connecting to common earth bar.
2) The job also includes, if necessary, supply & fixing of extension busbar of
same material on MCCB or panel board terminal / connector to connect more
than one no. of parallel cables or to connect higher size cable to lower size unit.
The job also includes earthing the glands and armour of the cable with common
earth bar or flexible copper mesh.(Cable termination qty. shall be as per site
3.5C x 240 sq. mm. A2XFY Cable (1 Run From Existing PMCC to PSB To MCC
3.2.2 3C x 240 sq. mm. A2XFY Cable (1 Runs for MCC Panel to SCF Pump Motor) 4 Nos. 825.00
3.2.3 4C x 6 sq. mm. A2XFY Cable (For WR-DB with TPN MCB at Sump & Pump 10 Nos. 111.00
House, Each Nos MOVPDB)
3.2.4 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For TPN MCB for Monorail EOT Crane 10 Nos. 77.00
at Pump House & Each MOV at Main Pump and MOV at Header)
3.2.5 2C x 2.5 sq. mm. 2XWY/2XFY Cable (For Each Main Motor space heater(as 8 Nos. 75.00
required), For Level Switch)
3.2.6 7C x 1.5 sq.mm. 2XWY/2XFY Cable (Fo. Each Motor LCS with Ammeter) 10 Nos. 75.00
3.2.7 10C x 1.5 sq.mm. 2XWY/2XFY Cable 8 Nos. 184.00
3.2.8 12C x 2.5 sq.mm. 2XWY/2XFY Cable (For Actuator LCS of Pump and Header) 8 Nos. 105.00
3.2.9 10Tride x 1.0 sq.mm. individual triad and overall shielded with aluminum mylar 8 Nos. 185.00
tape Signal Cable for RTD & BTD of motor (For Each Main Motor)
4.1.1 CABLE TRAY 30 Mtr. 388.00
SITC of GI ladder type cable trays with side channels of size - 75 x 15 x 15 mm/
100 x 15 x 15 mm & rungs of size - 35 x15 x 15 mm spaced at 250 mm apart,
fabricated from 2 mm thick sheet steel in standard length of 2.5 meter, duly hot
dipped galvanized after fabrication as per IS 2629- 1989/ IS 4759-1984 including
accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows,
covers and electro- galvanized hardware etc, erected on existing support as per
specification and instruction of engineer in charge.
300 x 75 mm - Ladder type
4.1.2 150 x 100 mm - Ladder type 30 Mtr 402.00
4.1.3 SITC of GI perforated type cable trays with returned edge/ flange, fabricated 50 Mtr 336.00
from 2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly hot dipped
galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including
accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows,
covers and electro-galvanized hardware etc, erected on existing support as per
specification and instruction of engineer in charge.
150 x 50 mm - Perforated type
4.1.4 100x 50 mm - Perforated type 50 Mtr 273.00
4.2.1 Supply, laying and erection of 90 mm approved make Double Walled 100 Mtr 95.00
Corrugated pipes (DWC) of polyethelene (confirming to IS 14930 II) with
necessary connecting accessoies of same material at required depth for laying of
cable below ground / road surface for enclosing cable and back filling the same
to make ground as per original. (For Pump cable) DWC Length is Approx.
Provide as per Actual Site Requirements.
4.2.2 Supply, laying and erection of 50 mm approved make Double Walled 100 Mtr 62.00
Corrugated pipes (DWC) of polyethelene (confirming to IS 14930 II) with
necessary connecting accessoies of same material at required depth for laying of
cable below ground / road surface for enclosing cable and back filling the same
to make ground as per original. (For LT & light cables).
DWC Length is Approx. Provide as per Actual Site Requirements.
5.1.1 CHEMICAL EARTHING SYSTEM 4 Nos 7,025.00
SITC of chemical earthing with earthpit of minimum bore size dia. 225mm Safe
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS-3043:1987
made of corrosion free G.I. Pipes having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising
or copper coated solid steel road / flat strip type connection terminal 14mm dia
with constant ohmic value surrounded by highly conductive corrosion resistant
chemical compound with high charge dissipation suitable for electrical
installation of 11 kV & 440V of 2Mtr. length of Pipe with one no. 25Kg. bag of
Back filling compound.
( For PSB & MCC Panel & Motor)
5.1.2 Supply, laying and erection of 40 mm(w) x 6 mm(T) etc. sizes as required, HOT 57 Kg 77.00
dip galvanized GI Strip including supply & fixing using GI spacers, saddles when
laid inside the building and inclusive of excavation & refilling of earth when laid
outside the building & interconnection with earth pit & all electro-mechanical
(40X6 G.I Strip wt1.88 Kg/m, 1.88 x 30=57Kg.)
5.1.3 SITC of 50mm(w) x 6mm(T) etc. sizes as required, HOT deep GI Strip including 155 Kg 77.00
supply & fixing using GI spacers, saddles when laid inside the building and
inclusive of excavation & refilling of earth when laid outside the building &
interconnection with earth pit & all electro-mechanical equipments.
(50X6 G.I Strip wt.2.3 kg/m, 2.3x 30Mt.= 115 kg.)
(For MCC Panel and PSB etc.)
5.1.4 SITC of HOT Dip Galvanized iron strip wire 8 SWG (For LCS etc.) 6 Kg 77.00
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x 50Mt.=6 Kg)
6.1.1 INTERNAL WIRING 100 Mtr 115.00
SITC of Mains & outlet points wiring with 1.1 kV grade FRLS PVC insulated
ISI marked flexible stranded copper conductor wires with medium class min.
25mm. dia. Rigid PVC pipe and accessories to be erected concealed in / to
be run on surface / wall / ceiling with following sizes as mentioned below. The
unit rate wirings shall be with connector, PVC junction box, wires, holder, ceiling
rose, angle holder, switch, sockets, switch board, brass chromium / cadmium
plated machine screws, phase and neutral wires, green Earth continuity wires etc.
as required to complete wiring from LDB panel to the final outlet termination
points. The wiring shall be as per IS:732, IS:4648 and as per tender
specification / IS.
(a) SITC of Mains wiring with 3 wire 1.5 sq.mm.
6.1.2 As per Above Item Specification. (b) SITC of Mains wiring with 3 wire 2.5 100 Mtr 134.00
sq.mm as per tender specification & IS.
6.1.3 As per Above Item Specification. (c) SITC of Mains wiring with 4 wire 1.5 100 Mtr 123.00
sq.mm as per tender specification & IS.
6.1.4 As per Above Item Specification (d) SITC of Mains wiring with 4 wire 2.5 100 Mtr 158.00
sq.mm as per tender specification & IS.
6.2.1 SITC of Point wiring for Light / fan / Bell / Primary Point with 2nos. 1.5 sq. 40 Nos 351.00
mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS
PVC insulated multistrand copper wires, pipe to be erected concealed in
flushed on wall / ceiling, complete with 6A Tissino Type ISI marked flush
type switch / bell push & accessories erected on metal / PVC Box covered with
3 mm thick PC (Polycarbonate) / Acrylic sheet with necessary lamp holder
/ ceiling Rose / H. D. connector as directed with medium class Rigid PVC pipe
6.2.2 SITC of 6A independent Plug with 2 nos. 1.5 sq.mm Cu. Mains size wiring & 5 Nos 310.00
earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires with medium class Rigid PVC pipe
and accessories to be erected on wall / ceiling, complete with ISI marked 3 /
Pin socket and tissino type switch erected with earth continuity connection
erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic
(3 nos. at Pump House cum LT Room)
6.2.3 SITC of 5/15A independent Plug with 2nos. 4 sq.mm Cu. Mains size wiring & 5 Nos 601.00
earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires with medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling, complete with ISI marked 3 / 5 Pin
socket and tissino type switch erected with earth continuity connection erected
on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic
sheet.(For 3 nos. Pump House cum LT Room)
6.3.1 1200 mm sweep ceiling fan, capacitor type, having double ball bearing 2 Set 1,581.00
450mm down rod, canopies, shackle, rubber bush, blades, electronic speed
regulator, suitable to operate on 230V,50Hz AC supply conforming to IS:
374/1979.Fan shall be painted with white colour.(2 Nos LT Panel)
6.3.2 380 mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball 2 Nos. 3,052.00
bearing, M.S.blades, mounting frame, forearms, suitable to operate on
230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy
grey colour controlled by one 6 A flush type switch on board and 6A plug point
(For 2 Nos. Chlorination Room)
7.1.1 LED LIGHT FIXTURES: 12 Nos 530.00
SITC of Indoor wall mounting LED indoor fittings with LEDs of wattage
Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder
coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate
optics with company mark/name 120 to 300 V,Power Factor more than 0.9, THD
< 10 %, CCT 4000 K to 6500K, Uniformity ratio >0.7, Luminaire efficacy>
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80 Certificates)
36 Watt or up to 25% higher wattage Tube Light with integral / non-integral
driver, Surge-2KV, IP-20, 4 feet, Cat-III
(For pump House cum LT Room)
7.1.2 SITC of Surface mounted LED Indoor Flood light fittings with High power 12 Nos. 5,143.00
White LEDs wattage of 1Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses with company
mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 10 %, CCT
Uniformity ratio >0.45, Luminaire efficacy> 85 lumens/watt . LED
driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80 certificates)
40 Watt Indoor Flood Light (IP-65), Surge -4KV Cat-III
7.1.3 SITC of 'B' class galvanised iron pipe 32 mm outside dia 45 cmslong duly welded 12 Nos. 340.00
on 20 cms x 20 cms x 3 mm thick M.S. base plate, erected on wall or corner for
mounting luminaire with necessary hardware materials duly painted for wall
mounting indoor flood light fixtures on Wall of Buildings.
8.1.1 EXTERNAL LED LIGHT FIXTURES & LIGHTING: 20 Nos. 6,028.00
SITC of Wall mounted 80W LED Outdoor Flood Light fittings with High
power White LEDs wattage of 1Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses with company
mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95,
THD < 10 %, CCT 5000 K to 5700K, Uniformity ratio >0.45, Luminaire
efficacy> 85 lumens/watt . LED driver efficiency > 85 %. ( Each fittings required
LM-79 & LM-80 certificates) Flood Light (IP-65), Surge -4KV, 80 watt Cat-
(for Area Lighting)
8.1.2 SITC of 'B' class galvanised iron pipe 32 mm outside dia 45 cms long duly 20 Nos 340.00
welded on 20 cms x 20 cms x 3 mm thick M.S. base plate, erected on wall or
corner for mounting luminaire with necessary hardware materials duly painted
for wall mounting indoor & outdoor flood light fixtures on Wall of Buildings.
9.1.1 SAFETY ACCESSORIES 2 Nos 8,586.00
SITC of following safety accessories complete with necessary fixing
brackets, other accessories and tools etc. as required to complete the job.
Supply & Erecting carbon dioxide (CO2) fire extinguisher of 6.5kg capacity with
necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in
9.1.2 Supplying stand first AID box with anticeptic cream, medicine for use on 2 Nos. 297.00
wounds due burn, crepe bandage, guage bandage, medicated ready to use
bandage (Band-aid) adhesive tape for medicinal user, scissors, anticeptic solution
(Savlon or similar) etc.
(All above contents shall be of standard makes)
(For Pump house / LT Room)
9.1.3 Providing printed instruction (First Aid) Chart both in English and Gujarati 2 Nos. 129.00
and duly framed with front glasses, for treatment of person suffering from electric
shock. ( For LT Room)
9.1.4 Supplying & fixing of FIRE bucket round bottom of 9 litres capacity made out 4 Set 212.00
of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and
Red outside with FIRE mark, filled with dry sand and kept on stand provided or
hung on wall hook.
9.1.5 Supplying and erecting floor mounting stand for keeping four nos. of FIRE 1 Nos. 933.00
buckets comprising 1500 mm in length, 900 mm height frame made out of 30mm
X 30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks
and duly painted with one coat of red lead and two coats of approved enamelled
10.2.1 Supply and laying of 6 mm thickness, 1000 mm wide Rubber Matting as per 6 Mtr 990.00
IS 5424 and breadth with good insulation property for 1.1 kV with more length
if required as per site. (For MCC Panels etc,)
10.1.2 Providing pair of rubber hand gloves suitable for working on 11kV/ 22kV supply. 2 Nos. 212.00
TOTAL ESTIMATE OF ELECTRICAL WORK (Without GST)
Signature of Contractor Additional City Engineer (Water Project)
Name : Ahmedabad Municipal Corporation
Company’s seal :
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 Technical Bid.pdf
02 Technical Specification Civil Work.pdf
02 Technical Specification E and M Work.pdf
03 Financial Bid.pdf
04 Tender Drawings.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .