Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC 800 RAM NAGAR ROORKEE DISTT HARIDWAR UK PIN 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.0 L+₹63,333.33 (7.57%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹9.8 L+₹1.5 L (17.7%)Rejected-AOC 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹10.0 L+₹1.6 L (19.0%)Rejected-AOC 308 RAMNAGAR ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹10.0 L+₹1.6 L (19.5%)Rejected-AOC OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-AOC Not lowest |
Tender Value
₹9.7 L
EMD Value
₹19,320
Closing Date
26 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
ADDN ALTN TO CERTAIN WORKS IN BLDG NO T 8
2023_MES_612390_1
8754/E8
Open Tender
Civil Works
Item Rate
180 days
Josimath
as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹19,320
Yes
6 Oct 2023
7 Aug 2023
2 Sept 2023
7 Aug 2023
26 Aug 2023
21 Aug 2023
Amount
Taking down chowkats or frames with shutter (without taking off shutters from the frame) exceeding 1.5 Sqm each but not exceeding 4 sqm complete all as specified and as directed.
All as per item No 1 but not exc.1.5 Sqm each complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as spd and directed
Dismantling frame work timber scantlings 40 sq. cm and over in section, in any position complete all as spd and directed
M&L for second class clean sawn softwood in scantlings as framed complete all as spd and directed
S&F powder coated (minimum thickness of powder coating 50 microns) aluminium frame for door, window, ventilators, partition wall, shutters etc including style & rails with standard powder coated aluminium section with one or more rebates, including aluminium snap beading complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 microns) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, handles 2 Nos in each door, hinges, powder coated aluminum snap beading, screws etc. complete all as specified and directed. Note: Rubber beading and glazing shall be measured and paid separetely.
S&F powder coated (minimum thickness of powder coating 50 microns) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, powder coated aluminium snap beading, screws etc. complete all as specified and directed. Note: Rubber beading and glazing shall be measured and paid separetely.
M&L for rubber beading for fixing glass panes in aluminium frame work complete all as specified and directed.
S&F for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing on page 182 of SSR Part II complete all as spd and directed. Make: Rajshree or Syntex or H2O Solution.
S&F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall/ceiling to make PVC frame as per specification and drawing complete all as spd and directed Make Rajshree or Syntex or H2O Solution.
S&F for anodised aluminium snap grid frame work for false ceiling including 6 mm dia. G.I. hanger (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F for PVC laminated gypsum false ceiling designer boards of size 595mm x 595mm x 4mm thick fixed on GI snap grid, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed
M&L for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly all as specified and directed for One light/fan/bell point controlled by one ,one way switch
All as per item No 16 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 16 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 16 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F of call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 1 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 3 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 4 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 6 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 8 module complete all as specified and directed.
S&F in replacement Switch modular type single pole one module, 6 Amps complete all as specified.
S&F in replacement Switch modular type single pole one module, 16 Amps complete all as specified.
S&F in replacement Socket outlet modular type, multipurpose, 2/3 pin, single pole two module, 6 Amps complete all as specified.
S&F in replacement Socket outlet modular type, multipurpose, 2/3 pin, single pole two module, 6/16 Amps complete all as specified.
S&F in replacement Modular bell push single pole one module, 6 Amps complete all as specified.
S&F in replacement Modular blank plate one module.
S&F in replacement of ceiling rose 2/3 terminals 65x25 mm dia polycarbonate isolated all as specified & directed.
S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed.
S&F in replacement of LED light fitting two feet 1x10 watt, slim design, 230volts, including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fix in replacement of LED slim square panel light fitting for surface ceiling light, 12 watt, colour warm white and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed. Make : Havells / wipro/Philips/Bajaj
Supply and fixing in replacement LED indoor ceiling / wall mounted spot light, colour warm white , rotable light head of capacity 9 Watt complete all as specified and directed. Make Bajaj/ Jackal/ Havells/ Phillips/ wipro
Supply and fixing in replacement LED wall mounted rectangular light fitting 12 Watt , colour warm white, complete all as specified and directed. Make Bajaj/ Havells/ Phillips/ wipro
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed on bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed .
M&L earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. Note: GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed .
Supply and fix in replacement MCB 6-40 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed .
Supply and fix in replacement MCB 40 amps, 10 KA, SPN 240 volt, 'C' series all as specified and directed
All as per item No 44 here in before but MCB SPN 63 amps.
Taking down and dismantling of 1.5/2 Ton capacity air conditioner indoor and outdoor unit after disconnecting of electric connection for servicing, overhauling and gas charging, brazing , additional length of copper tubing , insulation and refixing the same to the place decided by the user commissioning and testing after replacement of unserviceable parts Note :- Gas charging will be measured and paid separately under relevant item of schedule however copper tubing required for extension is deemed to be included in quoted rate..
M & L for GAS Charging (R-22/134A) complete suitable for 1.5//2 Ton Capacity Air conditioner complete all as specified and directed.
M&L for fix in replacement of AC/ box with 20 Amp MCB DP, protected socket with steel enclosure and plug top, 3 Way complete all as specified and directed. Make Havells Product code DHDDCDP025202003 or equivalent of Legrand / Anchor.
sagar associates
A.S. CONSTRUCTION COMPANY
ANEJA AND COMPANY
M/S RAMESH LAL
KISHORE CHAND DINESH CHAND
nautiyalandcompany
Nand Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .