| 1 | L1₹41.8 LAdmitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Admitted-Finance | |
| 2 | L2₹43.7 L+₹1.9 L (4.51%)Admitted-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L2 | Admitted-Finance | |
| 3 | L3₹44.1 L+₹2.3 L (5.38%)Admitted-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L3 | Admitted-Finance | |
| 4 | L4₹44.6 L+₹2.8 L (6.58%)Admitted-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L4 | Admitted-Finance | |
| 5 | L5₹48.4 L+₹6.5 L (15.6%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Glacier Cooling Solutions Private Limited L2 | Shree Ayyappa Engineering L1 | sapana enterprises L4 | AISWARYA ENTERPRISES L5 | M/S SOMANATH ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply, install, testing and commissioning of air cooled Variable Refrigerant Volume/Flow (VRV/VRF) air conditioning system mentioned below to meet the inside design condition of temperature 23 ± 2˚C comprising of multiple Inverted hermetically sealed Scroll compressors to ensure high EER low noise propeller type aero spiral fan, condenser coil with acrylic pretreatment or equivalent treatment for resistant to corrosion and suitable for coastal area for improved resistance to corrosion, refrigerant shutoff valves, safety devices & controls, lead free PC boards, suitable for operation on ecofriendly non CFC/HCFC based refrigerant. The outdoor units shall have variety of indoor units connected by common refrigerant piping, power and control cabling. The unit shall operate on 415 +/- 10%, 50 cycles, 3 phase, 4 wire AC supply and the outdoor unit shall have an inbuilt power supply for any auxiliary power supplies required with in the unit. VRV/VRF outdoor units shall meet the actual capacities at air over condenser temperature of 42-degree Celsius. All the Outdoor units should be selected based on ambient temperature of 42-degree Celsius air over condenser temperatures VRV/VRF units shall contain both oil balance and gas balance automatically including MS Angle Frame Support for Condensing Unit complete all as specified and directed. Note :- The contractor shall ensure proper nitrogen flushing and shall hold 500 psig Vacuum for 10 minutes between Low Side piping) | ||||||||
| 1.01 | 28 HP Top DISCHARGE ODU | 2 | Each | 7,18,340 ₹14,36,680 | 7,52,000 ₹15,04,000 | 7,33,900 ₹14,67,800 | 7,75,000 ₹15,50,000 | 7,09,000 ₹14,18,000 Lowest |
| 1.02 | 16 HP Top DISCHARGE ODU | 1 | Each | 5,05,000 ₹5,05,000 Lowest | 5,14,000 ₹5,14,000 | 5,09,000 ₹5,09,000 | 5,25,000 ₹5,25,000 | 5,21,000 ₹5,21,000 |
| 2.00Supply, installation of Ceiling suspended Cassette type VRV/VRF indoor unit with cordless remote, Y joints as per OEM and capable of working with ecofriendly non-CFC/HCFC based refrigerant for connecting/ compatible with VRV/VRF outdoor unit as per the following size complete all as specified and directed | ||||||||
| 2.01 | 4 TR FOUR WAY CASSETTE | 12 | Each | 72,700 ₹8,72,400 | 69,000 ₹8,28,000 Lowest | 69,000 ₹8,28,000 Lowest | 85,000 ₹10,20,000 | 69,800 ₹8,37,600 |
| 2.02 | 3.2 TR FOUR WAY CASSETTE | 3 | Each | 71,500 ₹2,14,500 | 67,000 ₹2,01,000 | 72,000 ₹2,16,000 | 75,000 ₹2,25,000 | 55,000 ₹1,65,000 Lowest |
| 2.03 | Supply, Installation of Refnet Joints Suitable Branching INDOORS and Twinning of ODU's | 13 | Each | 7,000 ₹91,000 Lowest | 12,000 ₹1,56,000 | 19,000 ₹2,47,000 | 9,000 ₹1,17,000 | 12,900 ₹1,67,700 |
| 2.04 | Cordless Remote | 15 | Each | 1,500 ₹22,500 Lowest | 1,760 ₹26,400 | 2,100 ₹31,500 | 4,500 ₹67,500 | 3,000 ₹45,000 |
| 2.05Notes for Item Nos 1 & 2:- Above Quoted Rates shall include with the following items: - (i) The work shall be carried out through OEM/authorized agency and shall be submitted while payment of RAR. (ii) One display board VRF A/C plant drawn on Acrylic white sheet with coloured paints duly marking the details duly fabricated with suitable aluminium frame of not less than 0.5m x 0.5m all as specified and as directed. (iii) Any other minor civil masonry work required for erection and smooth functioning of VRF AC plant such as opening in existing wall for pipe work, closing of open area at AC conditioned area with plywood/insulation materials, cable, copper pipe, opening in ceiling for grills/diffusers finishing of opening to match the existing work all as specified including diversion / shifting of existing internal electrification work. (iv) Necessary PCC/MS foundations for indoor and outdoor units all as per site requirements and OEM specifications. The cost required for the same shall be deemed to be included in the unit cost. (v) Any special items/accessories and components left out in the contract for successful completion of work shall be provided by the contractor and the cost for the same deemed to be included in the unit cost. (vi) Items such as refrigerant piping, gas , refnet joints,transmission/power cabling shall be measured and paid separately under relevant items | ||||||||
| 3.00Supply and fix 16 SWG Hard drawn copper refrigerant piping (Discharge and suction) with suitable sizes and thermal insulation with 19 mm Thick Nitrile rubber tubular foam, Covered with 8oz Glass Cloth and coated with 2 Coats Fostering and necessary Installation accessories such as supports and clamps etc. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards. The copper pipes need to be laid through GI cable tray suitable size made out of 14 Gauge GI perforated sheet with cover using necessary supports, fasteners etc. for Protection complete all as specified and as directed Note :- Cable tray will be measured and paid under relevant schedule item | ||||||||
Tender Value
Refer Docs
EMD Value
₹88,180
Closing Date
28 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004
PROVISION OF AIR CONDITIONERS AT DINING HALL OF BLDG NO P-433 (VISHAL BLOCK) AND P-408 (TEJAS BLOCK) AT NIAT, NAVAL BASE KOCHI
2026_MES_787104_1
8710/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹88,180
Yes
10 Oct 2026
31 Aug 2026
30 Sept 2026
31 Aug 2026
28 Sept 2026
15 Sept 2026
31 Aug 2026 - 1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, install, testing and commissioning of air cooled Variable Refrigerant Volume/Flow (VRV/VRF) air conditioning system mentioned below to meet the inside design condition of temperature 23 ± 2˚C comprising of multiple Inverted hermetically sealed Scroll compressors to ensure high EER low noise propeller type aero spiral fan, condenser coil with acrylic pretreatment or equivalent treatment for resistant to corrosion and suitable for coastal area for improved resistance to corrosion, refrigerant shutoff valves, safety devices & controls, lead free PC boards, suitable for operation on ecofriendly non CFC/HCFC based refrigerant. The outdoor units shall have variety of indoor units connected by common refrigerant piping, power and control cabling. The unit shall operate on 415 +/- 10%, 50 cycles, 3 phase, 4 wire AC supply and the outdoor unit shall have an inbuilt power supply for any auxiliary power supplies required with in the unit. VRV/VRF outdoor units shall meet the actual capacities at air over condenser temperature of 42-degree Celsius. All the Outdoor units should be selected based on ambient temperature of 42-degree Celsius air over condenser temperatures VRV/VRF units shall contain both oil balance and gas balance automatically including MS Angle Frame Support for Condensing Unit complete all as specified and directed. Note :- The contractor shall ensure proper nitrogen flushing and shall hold 500 psig Vacuum for 10 minutes between Low Side piping) | |||||
| 1.01 | 28 HP Top DISCHARGE ODU | 2 | Each | - | - |
| 1.02 | 16 HP Top DISCHARGE ODU | 1 | Each | - | - |
| 2Supply, installation of Ceiling suspended Cassette type VRV/VRF indoor unit with cordless remote, Y joints as per OEM and capable of working with ecofriendly non-CFC/HCFC based refrigerant for connecting/ compatible with VRV/VRF outdoor unit as per the following size complete all as specified and directed | |||||
| 2.01 | 4 TR FOUR WAY CASSETTE | 12 | Each | - | - |
| 2.02 | 3.2 TR FOUR WAY CASSETTE | 3 | Each | - | - |
| 2.03 | Supply, Installation of Refnet Joints Suitable Branching INDOORS and Twinning of ODU's | 13 | Each | - | - |
| 2.04 | Cordless Remote | 15 | Each | - | - |
| 3Supply and fix 16 SWG Hard drawn copper refrigerant piping (Discharge and suction) with suitable sizes and thermal insulation with 19 mm Thick Nitrile rubber tubular foam, Covered with 8oz Glass Cloth and coated with 2 Coats Fostering and necessary Installation accessories such as supports and clamps etc. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards. The copper pipes need to be laid through GI cable tray suitable size made out of 14 Gauge GI perforated sheet with cover using necessary supports, fasteners etc. for Protection complete all as specified and as directed Note :- Cable tray will be measured and paid under relevant schedule item | |||||
| 3.01 | Refrigerant piping (For VRF) | 150 | RM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
COMMONPAGES8710.pdf
Tender Documents • 0.51 MB
PS8710.pdf
Tender Documents • 0.88 MB
BOQ_882102.xls
BOQ • 3.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .