| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC THEKKEKOTTARAM RAMANTHALI PO KANNUR DIST KERALA 670 308 | RAMANTHALI | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹36.0 L+₹64,297 (1.82%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L2₹36.0 L+₹64,297 (1.82%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Other than lowest tenderer | |
| 4 | L3₹37.3 L+₹2.0 L (5.55%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Other than lowest tenderer | |
| 5 | L4₹38.5 L+₹3.2 L (8.91%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
22 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT)MILITARY ENGINEER SERVICESINDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_535951_2
GE MAINT EZHIMALA 8490
Open Tender
Civil Works
Item Rate
90 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
22 Sept 2022
4 Aug 2022
24 Aug 2022
4 Aug 2022
22 Aug 2022
10 Aug 2022
5 Aug 2022 - 8 Aug 2022
60 days
Amount
Dismantling of plain or corrugated steel sheeting, any other type of sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
Demolition of stone slab and tiles of any description or thickness in floors, landings aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for vitrified coloured ceramic tiles 8 to 10mm thick (square/ rectangular), light shade polished, area of each tiles not exceeding 0.36 sqm, in flooring provided with 4 mm divider and the same gap filled with epoxy grout ,set and jointed in neat cement slurry and pointed in white or coloured cement to match of light shade including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for vitrified coloured ceramic tiles 10mm thick (square/ rectangular), light shade polished, area of each tiles not exceeding 0.36 sqm, in dado/ skirting provided with 4 mm divider and the same gap filled with epoxy grout set and jointed in neat cement slurry and pointed in white or coloured cment to match of light shade including 15mm thick rendering in CM 1:4 complete all as specified and as directed.
M&L for scrapping down existing treatment and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour as per manufacturer's specification over a coat of primer complete all as specified and as directed.
M&L for powder coated anodised aluminium frame and shutters for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M&L for steel work in tubular trusses in any shape flat or curved section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel flat / curved sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and providing necessary hangers/ suspenders for the frame work complete all as specified and as directed by Engg in Charge.
M&L for 12 mm thick seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and applying two coat of distemper complete all as specified and as directed.
M&L for 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & fixed with screws to aluminium frame work complete all as specified and as directed.
M&L for 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., erected in position and securing runners with holdfasts and brackets complete all as specified and as directed.
M&L for colour code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing caping with suitable size GI flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting 6 Amps switch with socket on independent board including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint all directed at the site. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm.
(a) One Light/ fan point controlled by one switch.
(b) One 3 pin socket outlet outlet 5 Amps on the same board with other switches.
(c) 5 Amps socket point on independent board.
All as per item No.16 here in above but 2.5 sqmm for 15 Amps socket on independent board complete all as specified and as directed.
M&L for sub main wiring color coded using 2 runs of 2.5 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing caping along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly, including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring using 2 runs of 4 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing caping along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly, including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge. Notes for Item No 18 & 19:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Three runs of cable and one run of casing & capping with necessary accessories will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Supply and fix ceiling rose 3 pole 240V PVC/Poly carbonate insulated body ISI marked complete all as specifed and directed by Engineer-in-Charge.
S&F modular switch one way 6 Amps 1 module ISI marked complete all as specifed and directed by Engineer-in-Charge.
S&F modular socket 6 Amps 2 module multi pin ISI marked complete all as specifed and directed by Engineer-in-Charge.
S&F modular switch one way 16 Amps 1 module ISI marked complete all as specifed and directed by Engineer-in-Charge.
S&F modular socket 16 Amps 2 module ISI marked complete all as specifed and directed by Engineer-in-Charge.
Supply and fix MCB single pole AC 240 Volts, 6 to 32 Amps C-Series complete all as specifed and directed by Engineer-in-Charge.
Supply and fix MCB single pole & neutral, AC 240 Volts, 32 Amps C-Series complete all as specifed and directed by Engineer-in-Charge.
Supply and fix MCB Triple pole & neutral, 63 Amps, 415 Volts AC C-Series complete all as specifed and directed by Engineer-in-Charge.
Supply and fix RCBO's for earth leakage protection four pole 300 mA, 63 Amps complete all as specifed and directed by Engineer-in-Charge.
Supply and fix modular AC Socket with MCB single pole 25/32Amps C-Series, AC 240 Volts complete all as specifed and directed by Engineer-in-Charge.
Supply and fix fan regulator(Modular) electronic step up type 100/120 Watt AC 230 Volts complete all as specifed and directed by Engineer-in-Charge.
Supply and fix ceiling fan energy saving model, 220-240V, AC.,50HZ, 1 phase 1200mm sweep five star rated complete all as specifed and directed by Engineer-in-Charge.
Supply and fix in repair MCB DB VTPN 415V double door type, 6 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete all as specifed and directed by Engineer-in-Charge.
Supply and fix recess mounted 36W luminer 2x2 Tile, out put lumen greater than 100 lumen/wattsGlare free uniform illimination housing with opel diffuser with colour temp 6000K with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make :Crompton. Model PolarisNIO I LCTLRNE-36-FO-CDL or equivalent in Wipro/philips/Havells.
Supply and fix in repair triple pole and enclosure with a three pin and earth plug with socket complete with one triple pole MCB including 415 Volts 32 Amps complete all as specifed and directed by Engineer-in-Charge.
Supply, fixing, testing and commissioning of 15 KVA, three phase UPS with battery back up must be 30 minute, with the following features:- a. UPS technology - Double conversion VFI ( online). b. Architecture - Modular ,Builtin isolation transformer should be provided in the inverter output. c. Transfer time - Zero. d. IP rating - IP 20 or above. e. LED indication and LCD Display- Main ,Bypass ,Battery and any fault. Display for Input voltage, output voltage , total power, load percentage per phase, Bypass voltage and frequency, Inverter voltage & frequency,Battery voltage, charging current,,discharging current,Temperature & DC Bus voltage. f. Input voltage - 400 V AC, 3 PH+N+PE or above. g. Output voltage - 400 V AC 3 PH+N+PE or above. h. Bypass - 400 V AC , 3 PH+N+PE or above. j. Protections - (i ) Short circuit ,input over voltage, Over temperature, Over current, Over load and Battery low. k. Communication - Network Management should be as per RS232,RS 485 MODBUS,SNMP. l. Batteries and Battery charger- VRLA SMF/Tubular/Niccad/Lithioum ion. Battery back up - Must be 30 minute. m. Operating temperature- 0 degree to 50 degree. n. UPS- Certificate of UL compliance, FCC from Indian Agency. p. Manufacturer - ISO 9001;2015,ISO 14001; 2015,OHSAS 18001: 2007. q. Suitable MS batteries stand including painting as per direction of Engr-in-charge. MAKE : Power One/Volina/Microtech/Socomec
Supply and install 2 Ton split type air conditioner inverter type units indoor/ outdoor complete with (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit and with copper condenser with minimum 5 star rating all as directed. Make: Carrier/Daikin/ Mitsubishi /Hitachi (a) Indoor unit ceiling mounted with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof top. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cables as per site requrement ,these all items provided by contractor adnd no extra cast will pay to contractor. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc.
(e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate. Note: Required modificaion in false ceiling and wall opening for installation of Split Ac deemed to be included in the quoted rate of respective items at any hight of the building .Contractor may visit the site before quoting of tender to assess the actual requirement and no extra cost will be entertained in this account.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specifed and directed by Engineer-in-Charge. Make:V-Guard(VWI500)\Servomate\Microtek.
S&F MCB protected modular socket (Modular AC Box) 20 Amps, heavy duty 230 Volts AC ISI Marked complete all as specified and directed by Engineer-in-Charge.
M&L for copper piping of size 5/8" and 1/4" with proper insulation suitable to 1.5/2 TR airconditioner as extra length to lead conduits complete all as specified and directed. Note:- One running metre of both 5/8" and 1/4" pipe including insulation will be measured as one unit length.
M&L for sub main wiring with two runs of single core 6 Sq.mm for main wire and one run of single core 6 Sq.mm as earth wire of multi stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including surface/concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and all accessories as per site requirement all conforming to IS specification complete all as specified and directed. Notes:- (i) Two runs of main wire, one run of earth wire and one run of PVC conduit shall be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth wiring. (iii) Strictly follow the continuous wire without any joints.
M&L for maintenance free chemical earthing with 01 No of copper cladded 17mm dia nickel cadmium steel with high tensile strength electrode of each of 1.8m each jointed with suitable compressive coupler planted at depth not less that 1.80m depth and duly covered with low resistant superior conductive powdered non corrosive, concrete brand earth enhancing material all as directed including connecting up to the common bus bar for a length upto 7.5 m with copper strip of size 25 x 4mm to achieve an earth resistance of below 2.0 Ohms including suitable PCC earth chamber. The copper strip shall be jointed to electrode with exothermic welding and all other joints shall be properly brazed complete all as directed after dismantling the existing unserviceable earthing. Make:- M/S McML Protection Technologies Pvt Ltd. / M/S JMV Earthing Equipment Pvt Ltd / M/S JEF Techno Solutions (P) Ltd.
Notes:- (i) One No earthing shall be connected for obtaining lowest earth resistance which shall be less than two ohm. (ii) Electrode and copper strip of size 25 x 4 mm shall be welded using exothermic welding for interconnecting the earth electrodes and from earth to grid point up to15 m along with 40 mm dia GI light grade protection pipe. (iii) The carbon based compound shall have a resistance value of less than 0.1 ohm. The compound shall be of minimum not less than 35 kg per pit. (iv) The bore hole for earth electrode shall not be less than 100 mm dia and 2mtr deep from GL and the extended rod shall be driven to a total depth of 4 mtr. (v) Provn of earth pit chamber of internal size 150 x 150 x 150 mm depth with PCC 1:3:6 cover slab 40 mm thick with re-enforcement of 8mm TMT bars @ 100mm c/c both direction for each Earthing all as directed by Engineer-in-charge. (vi) Necessary earth work excavation in any type of soil, returning filling and making good the surrounding area complete. (vii) All the joints except test point shall be welded/ brazed properly and the copper earth strip whenever laid on the wall, floor etc shall be fixed on ceramic insulators not more than 600mm apart.
Supply and fix copper strip 20 x 3mm with saddles and fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipment including removing the old unserviceable strip and brazing all the joints complete all as specified and as directed.
M&L for tubes, 'medium grade', galvanised, 40mm dia with all fitting laid in trenches / pole for protection earth strip complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C1 chamber of size 45cm x 45cm x 45cm including, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways complete all as specified and directed by Engineer-in-Charge.
Supply and fix DMC / FRP insulators, of suitable size to seperate the earth strips from the walls, duly screwed on the walls and making holes in the earth strips by drilling and fixing the earth striprigidly with the insulators with GI bolts, nuts, washers etc complete all as specifed and directed.
M&L for dismantling of stone slab and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specfied and directed by Engineer-in-Charge.
M&L for machine cut granite stone slab 20mm thick approved colour and shade as in floors laid over 20mm thick screed bed in CM (1:6) and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the including grinding and polishing complete all as specfied and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring with 20-25mm thick over and including 20mm thick screed bed in CM (1:6) and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the including grinding and polishing complete all as specfied and directed by Engineer-in-Charge.
Supply and fix out door type weather proof test point box with hinged door locking arrangement, made of 3.0 mm thick MS sheet of size 300 x 300 x 150 mm comprising of Copper Bus of size 25 x 6 mm 200 mm long mounted on FRP/DMC insulators, duly fixed inside the box mounted on 40 x 40 x 4mm angle iron legs (02 Nos) with a clearance of at least 0.30 mtrs above GL and 0.30mtrs below ground including PCC for foundation and providing data plate of size 600 mm x 450 mm x made out of 3mm thick MS sheet fixed at top of the junction box on angle frame with nut bolt washers, duly painted with two coats of synthetic enamel paint of approved shade for identification of different earthings, over a coat of red oxide primer including digitally writing the Earthing data on seven lines with suitable size letters and users recommended colour as directed by Engineer -in- charge.
Supply and install,testing and commissioning of diesel engine driven generating set with separate AMF PANEL panel 82.5 KVA with water cooled engine of suitable BHP for 66 KW power generation @ RPM 1500, brushless frame with silencer and Canopy for sound less mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/dynamo and 66 kW/82.5 kVA electric alternator, 415 volts, 3 phase, 4 wire,50 Hz, Voltage Regulation ± 15, Insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components, fuel tank capacity as per OEM recommendations with level indicator installed on suitable steel frame with PCC foundation as per manufacturers instructions, Power Command genset Controller, fuel pipes, Dual spin on fuel filter, Dritype Aircleaner, Shutt off coil with safeties for LLOP/HWT , fuel pipes , bar metre, hour meter , oil temperature gauges, ammeter, ignition switch, radiator with cooling fan, maintanance free battery battery, including suitable size of copper cable leads with terminals, all mountings ,accessories and necessary foundation and AVM pads complete as per manufacurers recommendations and to the satisfaction of Engr in charge.
(A) PRIME MOVER :- Suitable for driving 66KW/82.5 KVA alternator Liquid cooled battery start diesel Engine of adequate capacity 110 BHP confirming of BSS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 hrs operaton complete with the following standard accessories :- a)Fly wheel to match with the flexible coupling b)Flexible coupling wih guard c)Air cleaner oil bath type / dry type d)Lubricating oil filter, fuel filter paper element type e)Blower type fan and radiator f)Governor for class "A" Goverming as per IS-1601 of DS 649/1958 g) Starter. Motor for electric start complete with dynamo altermator, lead acid batteries heavy duty of capacity 12 V 65 Ah or as per OEM recommendations, Nos & capacity as required with copper conductor leads of adequate size and length not less than 2 M including battery box all as directed.h) Hour meter and RPM indicator j) Exhaust pipe brought outside the building and lagging of entire length of exhaust pipe with 12 mm dia. k) Instrument panel duly wired comprising the following including protection for low lub oils high temperature :- l) Lube oil pressure gauge m) Battery change indicator meter n) Starting switch with key o) Lub oil temperature p) Engine temperature indicator
Notes:- i) any fittings/fixtures which are necessary for properfunctioning of the DG set shall also be deemed include in the unit rate quoted and shall be provided by the contractor without any extra cost to the Deptt. (ii) Necessary foundation for installation of DG set shall be provided as per manufacturers recommendations and cost deemed to be inclusive in the rate quoted for this item. (iii) All testing equipments are to be arranged by the contractor and testing shall be carried out by the contractor in presence of Engr-in-Charge and testing result duly signed by the Engr-in-charge and the contractor shall be kept in Record. (iv) Rate quoted by the contractor including the rate of first filling of lubricating oil, Coolant and duct with wooden cover from DG set to AMF Panel. AMF panel must be out side the canopy. (v) Drawings/catalog for DG Set and AMF panel got approved by the GE before ordering to the manufacturer.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and as directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and as directed.
M&L for earthing complete with Galvanised Iron earth plate electrode 600 mm x 600 mm x6 mm thick buried directly in ground, earth pit not less than 2.25 meter deep below ground level, connected to 32x6 mm size Galvanised Iron as earthing strip by means of bolts, nuts, check nuts, and washers of galvanised Iron /steel all as shown in electric plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including provn of necessary excavation and earthwork in any type of soil, PCC pit, RCC cover and 20 mm bore medium grade watering pipe, water funnel with GI wire mesh, 40 mm bore medium grade protection pipe, common salt, charcoal dust, returning filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed by Engr-in-charge.
Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying pipes complete all as specified and as directed. Notes:- For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification.
Excavation in trenches in hard / dense soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying pipes complete all as specified and as directed. Notes:- For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification.
Returning filling in trenches in layers n.exc. 25 cm after laying of pipes including spreading, levelling, and well ramming complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supply and spreading riddled earth for cushioning of the UG cable in trenches complete all as specified and as directed. Note:- Punned thickness shall be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover but Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
Supply and fix in replacement of route indicator for marking of UG cable of any size with cast iron round plate not less than 100 mm dia suitably fitted on iron and embeded with PCC block of size 30cmx30cmx45cm complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed.
M&L for cement concrete 1:2:4 Type B1, using 20mm graded aggregate as in foundations, including rafts, footings, foundation beams,plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-410W, Gde E-250A) complete all as specified and as directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and as directed.
Supply, erect and commissioning of outdoor type double door floor mounted free standing dust and vermin proof feeder pillar box with IP -65 protection fabricated out of 3.15 mm thick CRCA sheet duly pretreated in seven tnk process for degreasing, de rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated including Aluminium Busbar with suitable capacity, panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear comprtments. Provision of cable alleys to be kept on bottom cable entry for incoming and outgoing cables.A clear space of 400 mm to be kept from floor level for switch gear comprtment. Extended busbar links /terminals to be provided for heat dissipation. ( Note :- Feeder pillar box shall be procured from firms having CPRI approval certificate.). All as specified and directed by Engineer in charge. The panel shall be duly supported on angle iron of size 40x40x 4mm thick embedded in PCC 1:3:6 using 40 mm graded aggregate and coping of fourlegs by 1:2:4 ,the top of panel shall be canopy type and fitted with following accessories:-
Incoming EB supply MCCB TPN 160 Amps-36 KA 1 No, with thermal magnetic release Incoming DG Supply MCCB TPN 160 amps-36 KA 1 No, with thermal magnetic release outgoing Changeover switch 160 Amps- 1 No. Make :- ABB/GE/AREVA/L&T outgoing MCCB TPN125 Amps-25 KA 1 No,with thermal magnetic release outgoing MCCB TPN63 Amps- 1 No,with thermal magnetic release-Make :- ABB/GE/AREVA/L&T Aluminium bus bar TPN of suitable size with proper colour code and ,phase indicator LED assembly -1 No Multi function VAF + PF , 3 phase 5A rating meter flush type. Note:- Complete busbar should be connect for main incoming MCCB and Outgoing MCCBs. Not permitted copper flexible cable for inter connection of bus bar.
Supply and fix in replacement of sheet metal enclosure made out of 3mm thick MS sheet power coated of suitable size with 200 Amps rated aluminiun busbar with coulor code including one no MCCB 63 Amps 25 KA as incomer and suitable gland for cabling complete all as specified and directed by Engr-in-charge.
LUCKY ENTERPRISES
Sreekrupa Enterprises
devan enterprises
rvelectricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .