| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 |
Tender Value
₹1.3 Cr
EMD Value
₹50,000
Closing Date
23 May 2022, 6:00 pmClosed
Vishnukumar G
Office of the Project Director, Ground Floor, CTO, Near Government Press, Statue TVM 001
Footpath Thottuvala First Bridge to Aattutheeram Road in Kainakary GP Kuttanad LAC in Alappuzha District
2022_LSGD_484447_14
A1/142/2020/PMULSGD
Open Tender
Civil Works - Roads
Item Rate
300 days
Alappuzha
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹50,000
Yes
10 Nov 2022
10 May 2022
26 May 2022
10 May 2022
23 May 2022
10 May 2022
10 May 2022 - 16 May 2022
Amount
Road work and structures
11.1.1.1 : Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I.Ordinary soil (i)Upto 3 m depth
11.1.5 : Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.V. Marshy soil
2.7.D : Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(D)Dry Rubble Masonry
od1340916/2021_2022 : DRY RUBBLE MASONRY using departmental rubble _ rubble masonry with hard stone, including Through/Bond stone in foundation and superstructure including packing to compactness to lines and levels, cost and conveyance of all materials labour charges etc. complete as per approved drawing and relevant technical specifications.
75.7.1 : DRY RUBBLE MASONRY _ Random rubble masonry with hard stone, including Through/Bond stone in foundation and superstructure including packing to compactness to lines and levels, cost and conveyance of all materials labour charges etc. complete as per approved drawing and relevant technical specifications.
75.8.1.1 : Providing plain/reinforced concrete(1 cement:2 fine aggregate: 4 course aggregate) for substructure as per drawings and technical specifications Clause 802, 803, 1202 & 1203 as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)a)Materials
od1151120/2021_2022 : Coconut Pile - Supplying and stacking well matured straight coconut post for driving down throug various strata bellow bed level including cost coveyance labour charges etc complete. (Derived from DAR 60.64.1)
od1381485/2021_2022 : Coconut Pile - Driving down coconut pile to lines and levels through variuos strata including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile driving down after pointing the bottom end (Derived From DAR 60.64.4)
od1381486/2021_2022 : Cutting and removing the excess length of wooden piles to lines and levels and removing the cut end of piles and stacking within 150m (Derived from DAR 60.64.6)
14.8 : Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
11.2.1 : Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 I. Sand filling
od1151123/2021_2022 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump<br>set including conveyance to site and erection,cost of fuel, lubrication oil and other<br>stores, pay of staff etc complete
od1518279/2021_2022 : RING BUND Type II Putting up ring bund with earth fille gunny bags of top width<br>1.0m bottom width 2.0m height 2.0 m side and filling in between with earth to<br>form ring bund and maintaining the same leak proof till the completion of the<br>work and clearing the site by dismantling the bund after completion of the<br>work.etc.complete.
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I.P.C.C grade M 10 (i)Nominal mix 1:3:6
11.4.5 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203V. R.C.C. grade M 25
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
12.5.4 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 mIV.R.C.C. grade M 25
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
12.9 : Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
13.6 : Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
3.3 : Construction of Embankment with Material Obtained from Roadway Cutting <br> Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
od1651182/2021_2022 : Construction of subgrade with materials obtained from borrow pits-<br>Construction of subgrade with materials obtained from borrow pits with a lift upto 1.50 m transporting to<br>site spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with<br>a lead upto 1000 m as per TSC 301.5
3.5.2 : Excavation in Soil with Dozer with lead upto 100 m <br> Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
od1316384/2021_2022 : Providing, laying and spreading Material on a prepared sub grade, adding the designed quantity of cement to the spread Material, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-base<br><br> Cement Treated Crushed Rock or combination as per clause 403.2 and table 400.4(MODIFIED MORTH ITEM 4.6.1)
od1151127/2021_2022 : Construction of plain cement concrete pavement ,thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per clause 1501.2.2 M 30 (grade),coarse and fine aggregates conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork(steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing),spreading the concrete with showels, rakes, compacted using needle,screed, and plate vibrators and finished in continuous operation including provision of contraction and expansion ,construction joints, applying debonding strips, primer, sealant, admixtures as approved ,curing of concrete slabs for 14 days, using curing compound(where specified) and water finishing to lines and grade as per drawing and Technical Specifications clause 1501. Short panelled of size 0.75m x 0.75m (Modified item 6.4). Extra labour and machinery added for close joint cutting
75.8.1.1.A : Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate: 4 course aggregate) laid to required slope as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
4.1.A.3 : Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.<br> (iii) For Grading III Material
od1396781/2021_2022 : Supplying, providing and laying non -woven coir Geotextile fabric (750 to 800gm/sqm as per IS 15869 and IS 15872 with suitable laps, nail and trenches(as required) as directed by the departmental officers at site.
od1396887/2021_2022 : Fillling above reinforced subgrade(coir geo textile reinforce subgrade etc.) as per drawing and technical specification Clause 305.3.9<br><br>I. Sand filling modified Mord item 1.2.1
10.2.A.1.1 : Traffic Signs <br> A. Retro-reflectorised Traffic Signs <br> 1 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 <br> 1 900 mm Equilateral Triangle
10.2.A.1.3 : Traffic Signs<br>A. Retro-reflectorised Traffic Signs<br>1 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 <br> 3 600 mm Circular
od1518239/2021_2022 : Providing and erecting retro-reflectorised Object Hazard Marker 300mm x<br>900mm<br>Providing and erecting retro-reflectorised Object Hazard Marker sign with 07<br>years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09<br>micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick<br>/ aluminium composit material sheeting 4 mm thick with suitable back support<br>frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly<br>fixed 30cm above ground level by means of properly designed foundation with M<br>15 grade cement concrete 30cmx30x45cm, 45cm below ground level including<br>painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as<br>per approved drawing and clause 801.<br>300 mm x 900 mm(Data from MORTH 55.10.1)<br>
10.4.A.1 : Direction and Place Identification signs with size more than 0.9 sqm size board <br> A. Retro-reflectorised Traffic Signs <br> 1 Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
10.10.2 : Kilometre Stone Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 2Ordinary Kilometer Stone (Precast)
10.10.3 : Kilometre Stone Kilometre StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703iii)200 m stone (precast)
od1381511/2021_2022 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. (Derived from 8.13 MoRTH Roads)
Bidder Name
4A CONSTRUCTION
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .