Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 195 QUAY STREET OPP NAGINA HOTEL DARUKHANA REAY ROAD EAST MUMBAI MAHARASHTRA 400010 | MUMBAI SUBURBAN | MAHARASHTRA | 400010 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
14 Dec 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LTCDR SUMIT MODI
FTSU (CHN) PORT COMPLEX RAJAJI SALAI CHENNAI - 600009
RECTIFICATION OF DEFECTS ONBOARD INS DARSHAK, BATTIMALV AND BITRA
2020_NAVY_400920_1
FTSU/H/DSK/BMV/BIT/20-21 DATED 04 DEC 2020
Limited
Miscellaneous Services
Works
7 days
INS DARSHAK, BATTIMALV AND BITRA
3 documents required · 3 mandatory
₹0
Exempted
FTSU (CHN)
15 Dec 2020
5 Dec 2020
15 Dec 2020
5 Dec 2020
14 Dec 2020
8 Dec 2020
5 Dec 2020 - 8 Dec 2020
8 Dec 2020
90 days
25 NOS BONDING STRAPS TO BE REPAIRED/ RENEWED FOR EMI/EMC.(INS DARSHAK)
HEATING ASSISTANCE REQUIRED FOR THE FOLLOWING (INS DARSHAK): - (l) JAMMED TRIPLE ROLLER FAIRLEAD (QTY-04 NOS). (Il) JAMMED MUSHROOM HEADS (QTY- 10 NOS). (Ill) JAMMED FAIRLEAD (QTY -03 NOS).
9.2 M SMB BOAT CLEATS (QTY - 05 NOS) UPROOTED FROM BASE DUE TO FWT. TO BE MANUFACTURED AS PER SAMPLE (MAT - SS) AND FIXED/ REPAIRED/ RENEWED WITH GRP (APPROX AREA - 02 SQMTR). (INS DARSHAK)
RUBBER BEADING SECURING CLAMP (QTY- 15 NOS) OF SMB DAMAGED/UPROOTED DUE TO FWT. TO BE REPAIRED AS PER SAMPLE(MAT-SS) (INS DARSHAK)
WATER INGRESS FROM WINDOW OF DISHA AND DHRUVA DUE TO FWT. GRP REPAIR (04 SQMTR). (INS DARSHAK)
ASSISTANCE REQUIRED FOR REPAIR/ RENEWAL OF FAN BASE (QTY - 01 NOS) IN51 MEN MESS. (INS DARSHAK)
SERVICEABILITY CHECKS OF 4.7MTR RIB AND 7MTR RHIB AFT STUDY LINES SPRING HOOK (QTY 04 NOS EACH). TO BE REPAIRED/ RENEWED LOAD CERTIFICATES OF NEW HOOKS REQUIRED. (INS DARSHAK)
REQUIRED ASSISTANCE FOR RECTIFICATION/ RE-ALIGNMENTS OF MMG POST (PORT & STBD) FIRING ARC (QTY - 02 NOS) (MAT - MS). (INS DARSHAK)
THREE IN NOS NWT DOOR LOCKS ARE MALFUNCTIONING. TO BE REPAIRED/ RENEWED. (INS DARSHAK)
WATER LEAKEAGE OBSERVED IN SAILORS WC AND OFFICERS WC FROM HEALTH FAUCETS AND WATER CONNECTING HOSE(QTY-08 NOS ) DUE TO FWT. TO BE REPLACED AS PER SAMPLE. (INS DARSHAK)
SPURNWATER COAMING AT BRIDGE WING(STBD) THINNED/ HOLED (LENGTH APPROX 0.5 RMTR) DUE TO FWT. TO BE REPAIRED/ RENEWED (MAT- MS). (INS DARSHAK)
ANCHOR STROP WIRE ROPE FITTED ON FOXLE DAMAGED/ STRANDS WORN OUT. SERVICEABILITY CHECKS TO BE CARRIED OUT. ANCHOR STROP TO BE MANUFACTURED, IF FOUND UNSERVICEABLE. MAT – SWR, DIA - 12 MM, LENGTH - TWO MTR (WITH EYE ON BOTH END) QTY – TWO. (INS BITRA)
FISHERMAN PLATE LOCKING PIN SECURING ARRANGEMENT BROKEN. TO BE RENEWED. MAT – SS, CHAIN LENGTH - 300 MM, QTY – TWO. (INS BITRA)
LMG STAND FITTED IN QUARTER DECK CORRODED. TO BE RENEWED MAT – MS, QTY – ONE. (INS BITRA)
ROPE REEL FITTED ON QUARTER DECK DAMAGED/ BROKEN TO BE REPAIRED IN SITU. WELDING ASSISTANCE REQUIRED. (INS BITRA)
MMG STAND MOVING MECHANISM JAMMED. TO BE REPAIRED. HEATING ASSISTANCE REQUIRED. QTY. – ONE. MAT- MS (INS BITRA)
GUARDRAIL STANCHIONS BASE STRUCTURE CORRODED TO BE RENEWED MAT – MS. QTY - FIVE (INS BITRA)
BONDING STRAPS FITTED ON GUARDRAIL STANCHIONS BROKEN. TO BE REPLACED. QTY-20 (INS BITRA)
BOTTOM PLATE OF FLAG LOCKER FITTED ON FLAG DECK PERISHED/ DAMAGED. TO BE REPAIRED. MAT-ALUMINIUM, QTY – ONE. (INS BITRA)
SECURING EYE OF SUPPORTING ARM OF ENSIGN STAFF AT QUARTER DECK CORRODED. TO BE RENEWED. MAT – MS, QTY – TWO. (INS BITRA)
HYDRAULIC DOOR CLOSER OF FIVE NON WATERTIGHT DOORS DAMAGED. TO BE REPAIRED. (INS BITRA)
LEAKAGE OBSERVED FROM 4.7 MTR RIB COLLAR. TO BE REPAIRED. (INS BITRA)
LOCKING MECHANISM OF IGLA LOCKER BROKEN. TO BE REPAIRED. QTY –TWO. (INS BITRA)
SERVICEABILITY CHECK OF DEVILS CLAW IS TO BE UNDERTAKEN. QTY- TWO. (INS BITRA)
TEMPERATURE SWITCH OF BOTH HPAC MALFUNCTIONING, LEADING TO NON AVAILABILITY OF HIGH DISCHARGE TEMPERATURE TRIP. SERVICEABILITY CHECKS/ REPAIR TO BE CARRIED OUT. QTY- TWO. (INS BITRA)
SUB OPTIMAL PERFORMANCE OF SHIP'S SIREN OBSERVED. SERVICIBILITY CHECKS / REPAIRS TO BE CARRIED OUT. (INS BITRA)
PRESSURE TESTING OF BASCAA TO BE CARRIED OUT. QTY- SIX. (INS BITRA)
PRESSURE TESTING OF ELSA TO BE CARRIED OUT. QTY- EIGHT. (INS BITRA)
MACHINERY INTERCOM NOT AVAILABLE . SUSPECT MALFUNCTION OF LIC CARD IN MB SRE RACK. DI/DR TO BE CARRIED OUT. (INS BITRA)
MANUAL TO AUTO CHANGEOVER SWITCH FOR REGULATING VOLTAGE FROM SWITCHBOARD NOT AVAILABLE. SUSPECT MALFUNCTION OF RELAY UNIT IN AVR EXCITER PANEL. DI/DR TO BE CARRIED OUT. (INS BITRA)
RECURRING FALSE ALARM INDICATIONS OBSERVED IN CONTROL PANEL OF AFDS. DI/DR TO BE CARRIED OUT. MAKE- NAVICOM & AFMS 3000. (INS BITRA)
INPUT VOLTAGE FOR NINE SMOKE SENSORS NOT AVAILABLE, LEADING TO UNRELIABLE PERFORMANCE OF AFDS SYSTEM. SUSPECT FAULT IN MCP. DI/DR TO BE CARRIED OUT. MAKE NAVICOM & AFMS 3000 QTY- NINE. (INS BITRA)
PORT BRIDGEWING NAVIGATION LIGHT NOT WORKING. Dl RÈVEALS 230 V OUTPUT FROM NLCP CONTROL PANEL NOT AVAILABLE. DR TO BE CARRIED OUT. MAKE- RADIANT ELECTRONICS. (INS BITRA)
SEA WATER LEAKAGE OBSERVED FROM FIRE-MAIN PUMP 2. SUSPECT MECHANICAL SEAL WORN OUT. (INS BATTIMALV)
HIGH VIBRATION OBSERVED FROM AC SEA WATER PUMP NO 2. SUSPECT MOTOR MISALIGNED. (INS BATTIMALV)
HIGH VIBRATION OBSERVED FROM HPAC 1 MOTOR MDE (V) AND MFE (V). SUSPECT BELT PULLEY MISALIGNED. (INS BATTIMALV)
WEIGHING OF ALL BOTTLES OF C02 MAJOR FIREFIGHTING SYSTEM AS PART OF ANNUAL ROUTINES AS PER MAINTOPS. QTY- 06. (INS BATTIMALV)
OVERHAULING OF DA SEA WATER PUMPS QTY- 02. (INS BATTIMALV)
24V DC APLAB RECTIFIER FOR CRN-91 GUN GOT DEFECTIVE TWICE OVER LAST TWO MONTHS. SUSPECT SHORTING IN ELECTRICAL CIRCUITRY OF GUN. (INS BATTIMALV)
FCU MOTOR SPM READING FOUND IN RED ZONE. SUSPECT BEARING WORN OUT. (INS BATTIMALV)
AC MAIN CONTROL PANEL MPU CARD MALFUNCTIONING. SUSPECT MPU CARD SLOT WORN OUT. (INS BATTIMALV)
AER VENTILATION MOTOR NOT WORKING. SUSPECT MOTOR WINDING BURNT DUE TO WATER INGRESS AT SEA. (INS BATTIMALV)
MA4470 NOT SWITCHING ON. SUSPECT STEP DOWN TRANSFORMER DEFECTIVE. (INS BATTIMALV)
Vignesh Marine Technical Services Pvt Ltd
A Kay Marine Services
SMEC Automation Pvt Ltd
MAK TECHNICAL WORKS
ULTRA MARINE
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .