| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.5 L+₹3.2 L (21.1%)Rejected-AOC | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹18.6 L+₹3.4 L (22.3%)Rejected-AOC | L3 | Rejected-AOC Not Lowest Bidder | |
| 4 | L4₹19.3 L+₹4.1 L (26.9%)Rejected-AOC | L4 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NORTH SECUNDERABAD
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
PERIODICAL SERVICES AND CERTAIN BR REPAIRS TO ROOF PROJECTION FACIAS PLASTERING WALL CHAJJAS ETC AT ZONE G AREA UNDER AGE BR N NO II OF GE N SEC BAD
2020_MES_408184_1
8953
Open Tender
Civil Works
Works
240 days
Garrison Engineer North 35 Allenby Lines Secundera
For Enlisted Contractors Class E Category ai and for Un Enlisted contractors meeting the Enlistment criteria for appropriate class and category along with EMD
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹40,000
Yes
13 Mar 2021
30 Dec 2020
5 Feb 2021
30 Dec 2020
3 Feb 2021
20 Jan 2021
30 Dec 2020 - 12 Jan 2021
60 days
Amount
Material and labour for preparing the old decorated surfaces of walls up to any height and applying one coat of white wash complete all as specified and as directed.
Material and labour for preparing the old decorated surfaces of ceilings at any height and applying one coat of white wash complete all as specified and as directed.
Material and labour for preparing the old decorated surfaces of walls of any height by washing, rubbing down and stopping of old distempered surfaces and applying one coat of distemper oil emulsion of approved colour complete all as specified and as directed.
M&L for preparing old distempered surfaces of ceilings, by washing, rubbing down and stopping and applying one coat of distemper oil emulsion of any colour complete all as specified and as directed.
M&L for preparing old surfaces of walls and application of putty (any number of coats including smoothening using abrasive paper etc. ) and applying two coats of distemper oil emulsion over a coat of chalk whiting primer complete all as specified and as directed.
M&L for preparing the plastered old decorated surfaces of walls and applying one coat of cement base paint complete all as specified and as directed.
M&L for prepering old decorative surfaces of walls and applying one coat of colour washing complete all as specified and as directed.
M&L Preparing old painted wood and wood based surfaces of any description over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L Preparing old painted steel and iron surfaces of any description over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L Preparation of old weather proof paint by washing, rubbingdown and applying one coat of weather proof paint (APEX) incl scaffolding staging as necessary complete all as specified and as directed.
M&L for witting letters or figures (Block, Roman, Italic or Indian) not exceeding 30 high etc complete all as specified and as directed.
Demolition of cement concrete of any description and in roof padding concrete including any type of treatment complete all as specified and as directed.
Material and labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
Material and labour for 40 mm thick plain cement concrete in 1:2:4 type B0 using 12.5mm graded stone aggregate as in padding concrete on roof tops and finishing even and fair complete all as specified and as directed.
Material and labour for roughening the old concrete roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust etc and applying a coat of neat cement slurry at the rate of 3 Kilo gram per square metre complete all as specified and as directed
Material and labour for rendering 10mm thick on brick work or concrete surfaces in cement mortar 1:4 duly mixing with water proofing compound at the rate of 3% by weight of cement and finished even and smooth complete all as specified and as directed. NOTE:- Water proofing compound will be measured and paid separately under relevent items in this schedule.
Material and labour for sweeping with wire brushes and cleaning with water over the roof surfaces and application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces over that a coat of blown bitumen of 85 / 25 at the rate of 1.2 kilogram per square metre over that a coat of bituminous aluminium paint at the rate of 100 grams per square metre complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Supply only water proofing compound complete all as specified and as directed.
Supply and fix 500 litres capacity rotational moulded polyethylene water storage tank of triple layer type (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I along with 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including dismantling the existing water tank of any description complete all as specified and as directed
Supply and fix 1000 litres capacity rotational moulded polyethylene water storage tank of triple layer type (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I along with 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including dismantling the existing water tank of any description complete all as specified and as directed
M & L for 15 mm bore steel water tubing, ‘medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors and including taking down etc steel tubing and connections complete all as specified and as directed.
M & L for 20 mm bore steel water tubing, ‘medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors and including taking down old steel tubing and connections complete all as specified and as directed.
Supply and fix 25 mm bore steel water tubing, ‘medium grade’ galvanised, with all fittings fixed complete to walls and ceilings or laid in floors and including taking down old steel tubing and connections complete all as specified and as directed.
M & L in repairs for 20 mm bore gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed.
Dismantling of single layer Manglore pattern or similar tiles in roofing Note. Dismantling will have to be carried out in patches of area complete all as specified and as directed.
Dismantling of batterns for tiles shigles etc of any size incl tilting fillets exceeding 15 centimetre complete all as specified and as directed.
Dismantling of the Asbestos cement (Corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and as directed.
M&L for Mangalore pattern roof tiles, interlocking at side joints, laid dry complete all as specified and as directed.
All as per Item No 28 above but except tiles fixing only complete all as specified and as directed. Note: Serviceable tiles obtained from item no. 24 shall be reused in this item.
M&L for ridge or hip tiles to suit Manglore pattern of roofing tiles bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
All as per Item No 30 above but except ridge or hip tiles complete all as specified and as directed. Note: Serviceable ridge tiles obtained from item No. 24 shall be reused in this item.
M&L 2nd class hard wood clean sawn battens for tiles at roof of sectional area exceeding 5 sqcm and not exceeding 15 sqcm spaced at 30 cm centre to centre complete all as specified and as directed.
All as per item No. 32 above but fixing only except battens complete all as specified and as directed. Note: Serviceable battens obtained from SI No. 26 shall be reused in this item
M&L for preparing the surface of tiles or slate battens of any size and spacing, treated all over (measured overall on one side only, spaces not deducted) with two coats of creosote oil on new surface complete all as specified and as diretced.
M&L for 6 mm thick asbestos Cement, corrugated or semi corrugated sheets in roofs fixed with 'L' type or 'J' type or cranked hook bolts including necessary lpas all as specified in SSR part I complete all as specified and as directed.
All as per Item No 35 above but except sheets fixing only complete all as specified and as directed. Note: Serviceable sheets obtained from item No. 27 shall be reused in this item
M&L for 6mm thcik asbestos cement two piece adjustable plain wing ridge in roofs fixed with 'L' type or 'J' type or cranked hook bolts including necessary laps all as specified in SSR part I complete all as specified and as directed.
All as per SI item No. 37 above but except ridges fixing only complete all as specified and as directed. Note: Serviceable ridges obtained from item No. 27 shall be reused in this item
S & F pre painted gal valume aluminum Zinc coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
S & F pre painted gal valume aluminum Zinc coating GI based plain steel sheeting 0.5mm thick of any colour having tensile strength of 550 MPA as in ridge ,gutters etc fixed with self tapping screws complete all as specified and as directed.
Demolition of brick work built in cement mortar as in parapet for roof, walls complete all as specified and as directed.
M&L for Brick work with fly ash bricks straight or curved on plain exceeding 6 m mean radious built in CM 1:6 as in parapet walls etc above the roof complete all as specified and as diretced.
M&L for Plain cement concrete 1:2:4type B1 using 20mm graded aggregate as in benching/coping over the level difference in roofs/walls with necessary form work in roof/walls complete all as specified and as diretced.
Dismantling of timber scantlings, rafters and purlins over 40 sqcm in section in any position, unframed work from roofs complete all as specified and as diretced.
M&L for 2nd class hard wood timber scantling clean swan framed and fixed in position to match the adjoining work complete all as specified and as directed.
Dismantling and breaking up drain pipes (AC or reinforced concrete) of any description of 100mm bore complete all as specified and as diretced.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors/wall including all fittings complete all as specified and as directed.
All as per item No 47 above but 75mm bore complete all as specified and as directed.
S & F PVC (SWR) bends any radius 75mm complete all as specified and as directed.
S & F 110mm dia PVC (SWR) bends any radius complete all as specified and as directed.
Supply & fixing in repair PVC (SWR) Vent cowls 110mm dia complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
M&L for MS framed work as in doors and chowkats or gates of angles or other section with gusset plates, rails, braces etc, complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging fittings (exclusive of steel sheeting or other covering) (Fe-410-w Gde-250) complete all as specified and as directed.
S&F framed work such as grills, framed guard bars etc with end of bars shouldered riveted or angle into spikes framed guard bars ,and similar work conforming to grade Fe 290-0 Gde -E -165 complete all as specified and as directed.
S&F 0.80mm thick, mild steel plain black sheeting as covering to door shutters and similar work, cut to size, edges beaded if directed, holes punched, incl riveting or welded to steel members etc with plain 40mm lap joints or welded/riveted seams including bending, turning U, mitred angles stopped ends, outlets etc as required complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors etc laid, bedded and painted in any mortar complete all as specified and as directed.
M&L for rough shahabad stone flooring bedded in CM 1:6 20mm thick (min) jointed and pointed in CM 1:3 thickness of stone slab varrying from 20 to 25mm complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below & above ground level) complete all as specified and as directed.
Material and labour for 75 mm thick plain cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) in plinth protection / paths laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at the junction of wall and plinth protection , at 3 metre interval and every change of direction duly filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth to be sealed with ceiling compound grade ‘A’ complete all as specified and as directed
M & L for 100 mm thick cement concrete type B1 by using 20mm graded aggregate 1:2:4 as in flooring etc. including finished surface smooth and even with out using extra cement complete all as specified and as directed.
M & L 75mm thick cement concrete type B1 by using 40mm graded aggregate 1:2:4 as in paths etc laid in panels including finished surface smooth and even with out using extra cement complete all as specified and as directed.
Dismantling wall floor or hearth tiling including cement mortar bedding but not backing and rubbish off the premises complete all as specified and as directed.
S & F for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of eahc tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and painted in white cement to match complete all as specified and as directed.
S & F glazed ceramic coloured tiles 300x200mmx 7mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match complete all as specified and as directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.11 but not exceeding 0.18 sqm in floors, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles complete all as specified and as directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.11 but not exceeding 0.18 sqm in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles complete all as specified and as directed.
M&L for Screed bed or bedding layer of cement mortor 15mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed.
M&L for rendering 10mm thick on brick stone walls in CM 1:4 as backing coat of tiles complete all as specified and as directed.
Taking down cement plaster on brick wall including racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L 15mm thick cement plaster in cement mortar 1:4 on the brick surfaces duly mixing with water proofing compound at the rate of 3% by weight of cement finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant items in this schedule.
M & L for plastering 15mm thick on fair faces of brick work or concrete surface in CM 1:6 including finished the surfaces smooth and even without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on ceillings in CM (1:3) and finishing surface even and smooth without using extra cement etc in patches, area not exceeding 3 sqm in each patch complete all as specified and as directed.
M & L for Rendering 10mm thick on concrete surfaces in cement mortar 1:4 in ceiling / chajja's/ downwards facias/ roof projection. duly mixing with water proofing compound at the rate of 3% by weight of cement and finished even and smooth without using extra cement in patches, area n. exc 3 sqm in each patch complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant items in this schedule.
M&L for preparation of plastered surfaces and applying two coats of cement based paint over a coat of primer on wall surfaces complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls in and applying three coats of white wash to match with the existing surfaces complete all as specified and as directed.
M&L for preparing new plastered or unplastered ceiling surfaces and applying three coats of white wash on ceilings complete all as specified and as directed.
M & L for two coats of colour wash over one coat of white wash on walls including preparation of new surface complete all as specified and as directed.
S & F rolled section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates conforming to Fe-290 Grade E-165 complete all as specified and as directed.
Dismantling ceiling of any description including cover fillets complete all as specified and as directed.
S & F 605x605 mm anodised aluminium snap grid framed work for false ceiling all as specified including 4mm thick non asbestos fibre cement buildings boards fixed or laid/inserted to timber/GI/aluminium frame work in ceiling with screws and applying two coats of OBD on ceiling including priming with alkali resistant priming paint and preparation of new surfaces complete all as specified and as directed.
M & L for PCC type C1 1:3:6 (Using 20mm graded stone aggregate) as in eaves filling complete all as specified and as directed.
M&L for providing Cement concrete in lintels upto 1.5m span, cills, copings, bed plates etc including necessary form work type B1 1:2:4 (20mm graded aggregate) complete all as specified and as directed.
S& F in repairs Mild steel chromium plated curtain rod 19 mm dia with fixing brackets, stops, rollers etc, of standard thickness and of any length complete all as specified and as directed.
M&L fixed in repairs 18 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws including clean sawn fillets exceeding 13sqcm and not exceeding 25 sqcm, 3mm thick teak wood lipping in cupboards /shelves complete all as specified and as directed. .
S&F 100mm long MS butt hinges, medium weight cold rolled complete all as specified and as directed.
M&L for two coats of synthetic enamel paint on steel surface of any description over 10cm width or grith including preparation of new surfaces and applying one coat of Red oxide primer complete all as specified and as directed.
Hacking out old broken glass (any thickness size quality or description) from wooden/metal frame glazed with putty or fixed with beads complete all as specified and as directed.
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty/beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 3mm thick figured glass, pin headed type and glazing with oil putty/beads in squares not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Demolition of cement concrete in roofs, floors (other than ground floors,) beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M & L for providing pre cast cement concrete in landings, cover slabs, chajjas, water troughs, shelves and similar articles type B-1 1:2:4 20mm graded aggregate set in CM 1:4. including with necessary formwork in roof/walls/ chajjas etc complete all as specified and as directed.
Disconnecting existing tanks for repairs, cleaning etc and hosting if required reconnection and refixing in position etc Capacity of tank exceeding 250 & not exceeding 500 Ltrs capacity complete all as specified and as directed. Note: Cleaning, repairing etc, measured separately.
M&L for Cleaning & removing all scale of dirt etc from tanks & from mouths of circulating pipes etc capacity of tank exceeding 250 & not exceeding 500 Ltrs complete all as specified and as directed.
All as per item No. 93 but exceeding 500 ltrs and not exceeding 1000 ltr capacity complete all as specified and as directed.
All as per item No. 93 but exceeding 1000 ltrs and not exceeding 2000 ltr capacity complete all as specified and as directed.
VACON INFRASTRUCTURES
M/s GM Constructions
harshraj and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .