Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC single bidder in retender |
| Sl No | Description | Qty | Unit | HARIS T A L1 |
|---|---|---|---|---|
| 1.00Pump installation | ||||
| 1.00 | OD104704/2021-2022:Supply, Conveyance, Installation, Testing and commissioning of 3Phase, 415V, 5HP/3.7KW, 415 V, 50Hz, Open Well submersible pump set confirming to IS capable to discharge a total head of 22/57 mtr , dishcarge 450/120 LPM, with out let 50mm sizer as per IS specification as required.[Texmo /Kirloskar ] including providing water level controller to Switch ON/OFF the motor according the level of water in the sump | 1 | 1 nos | 42,291 ₹42,291 Lowest |
| 1.00 | 90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. | 1 | each | 429 ₹429 Lowest |
| 1.00 | OD245319/2023-2024:S & F Motor starters of the following ratingsElectronic Soft Starter for 5 to 7.5HP motor | 1 | each | 67,998 ₹67,998 Lowest |
| 1.00 | 90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL) | 1 | each | 4,054 ₹4,054 Lowest |
| 1.00 | OD106386/2021-2022:Supply, conveyance, Installation, testing & commissioning of 3 Phase , 15 KVA Diesel Generator set with integral acoustic enclosure as per CPCB IV norms with standard accessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar/Cummins/Asok Leyland b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Air cooled with radiator. e) Aspiration Turbo charged after cooled. f) Design - Suitable for generating set operation g) Engine capacity as per manufactures standards , 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Mechanical governor of class A1) Fuel filter h) Lubricating oil filter i) Exhaust silencer j) Exhaust Muffler k) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/Crompton/Leroy Somer/Stamford b) Type - Self exited and self regulated. c) Capacity - 15 KVA/12 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H , Brushless alternator with automatic voltage regulation VG3 .The Alternator should confirm to IS:13364(part-1) . Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection. standard control panel wih 32 A 4P MCB and accessaries such as Multi function meter and separate Energy Meter etc. complete. | 1 | each | 4,61,097 ₹4,61,097 Lowest |
| 1.01 | OD106385/2021-2022:Supply and providing the following size of B class MS pipe conforming to relevant IS specifications complete with heavy guage specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/wall/any other mechanical support etc as required.- 80 mm dia B class MS pipe as extended exhaust pipe. | 10 | metre | 1,035 ₹10,350 Lowest |
| 1.01 | OD106384/2021-2022:Supply and providing 10A , 12V Generator/Charger Compatible with Automatic Battery with Fully Automatic Boost / Float charging etc. complete | 1 | each | 11,661 ₹11,661 Lowest |
| 1.01 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 4 | cum | 385 ₹1,540 Lowest |
| 1.01 | 14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. | 2 | cum | 7,974 ₹15,948 Lowest |
Tender Value
₹7.9 L
EMD Value
₹19,716
Closing Date
5 Jul 2025, 6:00 pmClosed
AEE PWD Electrical Kasaragod
O/o AEE PWD Electrical Sub Division Kasaragod
Electrification
2025_PWD_737580_6
PWD/BLDG/TR/584/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Kasaragod
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,740
Yes
₹19,716
Yes
30 Aug 2025
30 Jun 2025
9 Jul 2025
30 Jun 2025
5 Jul 2025
30 Jun 2025
Amount
Pump installation
OD104704/2021-2022:Supply, Conveyance, Installation, Testing and commissioning of 3Phase, 415V, 5HP/3.7KW, 415 V, 50Hz, Open Well submersible pump set confirming to IS capable to discharge a total head of 22/57 mtr , dishcarge 450/120 LPM, with out let 50mm sizer as per IS specification as required.[Texmo /Kirloskar ] including providing water level controller to Switch ON/OFF the motor according the level of water in the sump
90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors.
90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL)
OD106386/2021-2022:Supply, conveyance, Installation, testing & commissioning of 3 Phase , 15 KVA Diesel Generator set with integral acoustic enclosure as per CPCB IV norms with standard accessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar/Cummins/Asok Leyland b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Air cooled with radiator. e) Aspiration Turbo charged after cooled. f) Design - Suitable for generating set operation g) Engine capacity as per manufactures standards , 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Mechanical governor of class A1) Fuel filter h) Lubricating oil filter i) Exhaust silencer j) Exhaust Muffler k) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/Crompton/Leroy Somer/Stamford b) Type - Self exited and self regulated. c) Capacity - 15 KVA/12 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H , Brushless alternator with automatic voltage regulation VG3 .The Alternator should confirm to IS:13364(part-1) . Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection. standard control panel wih 32 A 4P MCB and accessaries such as Multi function meter and separate Energy Meter etc. complete.
OD106385/2021-2022:Supply and providing the following size of B class MS pipe conforming to relevant IS specifications complete with heavy guage specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/wall/any other mechanical support etc as required.- 80 mm dia B class MS pipe as extended exhaust pipe.
OD106384/2021-2022:Supply and providing 10A , 12V Generator/Charger Compatible with Automatic Battery with Fully Automatic Boost / Float charging etc. complete
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD106387/2021-2022:Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
OD234594/2024-2025:63A, On-Load Change Over Switches In Open Execution
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD106402/2021-2022:Supply and fixing of 10 W LED bulk head fittings IP65 die cast aluminum Poly carbonate front cover directly on wall including drilling necessary holes, giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring making good the damages, colour washing etc as required.(Philips/Bajaj/Havells/Wipro
OD245216/2023-2024:Supply and wiring Combined plug points with 6 A modular type switch and 6A 5 pin socket in the same switch board as that of light points
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.6.5.3:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.00 sq mm
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD112937/2021-2022:Supply and installation of HD pipe of size 32/40mm dia with standard accessories in the bore well as delivery pipe.
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD113786/2021-2022: Supply and laying of 20mm or nearest size Nylon rope
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD106420/2021-2022:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
OD106421/2021-2022:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD106422/2021-2022:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD106597/2021-2022:Providing and fixing following capacity TP&N disconnector fuse switch unit with ISI marked HRC fuses inside powder coated cubicle fabricated with 1.6mm sheetsteel including drilling holes in making connections, etc. as required. 32 Amp TP & N
OD106600/2021-2022:Supplying and fixing 32A HRC Fuse with HRC Fuse link with connections, in existing meter board
OD106601/2021-2022:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD106598/2021-2022:Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board( GS-MB-6535) and to fix KSEB LT meters, TVM with CTs/DHD and fuse cut out etc as required including fixing it on wall, making good the damages colour washing etc. as required. 650*350*250mm
OD106599/2021-2022: Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main
OD106603/2021-2022:Fees for getting sanction from Electrical inspectrate including all laison work etc.(actuals will be paid on production of relevant documents.)
OD106604/2021-2022:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
OD106605/2021-2022:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
OD107272/2021-2022:Supply and providing 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet
OD107273/2021-2022:supply and providing 4.5 Kg Dry Chemical Powder Type fire Extinguisher with hose and clamps including fixing it to wall as required.
Bidder Name
HARIS T A
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1262270.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .