Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAdmitted-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Admitted-Finance | |
| 2 | L2₹40.9 L+₹1.3 L (3.20%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹45.4 L+₹5.8 L (14.6%)Admitted-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Admitted-Finance | |
| 4 | L4₹45.6 L+₹6.0 L (15.1%)Admitted-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Admitted-Finance | |
| 5 | L5₹49.5 L+₹9.9 L (24.9%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KAPOOR ELECTRICALS L1 | M/s badrinath Traders L3 | DOON DIESEL SALES AND SERVICE L5 | V r traders L4 | trinity construction L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L in replacement of LT feeder piller box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93.
Incomming :- (a) MCCB , 400 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 630 Amps - Set of three.
b) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
c) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
d) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
e) CT Coils of suitable ratio -01 Set. | 2 | Each Job | 52,000 ₹1,04,000 | 90,000 ₹1,80,000 | 99,000 ₹1,98,000 | 42,999 ₹85,998 Lowest | 89,000 ₹1,78,000 |
| 2.00 | M&L in replacement of LT feeder piller box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93
Incomming :- (a) MCCB , 315 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 500 Amps - Set of three.
a) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
b) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
c) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
d) CT Coils of suitable ratio -01 Set. | 2 | Each Job | 52,000 ₹1,04,000 | 90,000 ₹1,80,000 | 95,000 ₹1,90,000 | 39,999 ₹79,998 Lowest | 89,000 ₹1,78,000 |
| 3.00 | M&L in replacement of LT feeder piller/junction box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93.
Incomming :- (a) MCCB , 250 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 315 Amps - Set of three.
b) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
c) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
d) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
e) CT Coils of suitable ratio -01 Set. | 2 | Each Job | 51,000 ₹1,02,000 | 80,000 ₹1,60,000 | 95,000 ₹1,90,000 | 39,999 ₹79,998 Lowest | 93,000 ₹1,86,000 |
| 4.00 | M&L in replacement of LT panel box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93.
Incomming :- (a) MCCB , 250 Amps, 4P, 415V,25 KA - 01 Each, Al busbar of capacity 315 Amps - Set of three.
Outgoing :- (a) MCCB, 250 Amps, 4P, 415V, 25 KA- 01 Each
b) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
c) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
d) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
e) CT Coils of suitable ratio -01 Set. | 2 | Each Job | 52,000 ₹1,04,000 Lowest | 90,000 ₹1,80,000 | 1,00,000 ₹2,00,000 | 84,999 ₹1,69,998 | 95,000 ₹1,90,000 |
| 5.00 | Dismantling and taking down Unserviceable earthing and Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick burried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | 2,000 ₹40,000 Lowest | 4,000 ₹80,000 | 6,000 ₹1,20,000 | 2,499 ₹49,980 | 2,200 ₹44,000 |
| 6.00 | Supply and Fixing in replacement MCCB TPN 400 Amps , 415 Volts, 50 KA ,4 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. | 2 | Each | 7,000 ₹14,000 | 15,000 ₹30,000 | 15,000 ₹30,000 | 5,999 ₹11,998 Lowest | 6,000 ₹12,000 |
| 7.00 | Supply and Fixing in replacement MCCB TPN 250 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. | 2 | Each | 6,500 ₹13,000 | 12,000 ₹24,000 | 9,000 ₹18,000 | 5,499 ₹10,998 | 4,000 ₹8,000 Lowest |
| 8.00 | Supply and Fixing in replacement MCCB TPN 200 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection all as per direction of Engr-in-Charge. | 2 | Each | 6,000 ₹12,000 | 10,000 ₹20,000 | 8,500 ₹17,000 | 4,999 ₹9,998 | 3,500 ₹7,000 Lowest |
| 9.00 | Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc | 1,200 | RM | 2 ₹2,400 Lowest | 5 ₹6,000 | 5 ₹6,000 | 2.99 ₹3,588 | 5 ₹6,000 |
| 10.00 | Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3½ core | 300 | RM | 1,990 ₹5,97,000 | 1,800 ₹5,40,000 | 1,700 ₹5,10,000 | 1,899 ₹5,69,700 | 1,600 ₹4,80,000 Lowest |
Tender Value
₹41.7 L
EMD Value
₹83,400
Closing Date
11 Jul 2026, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
SPECIAL REPAIR TO RING MAIN ELECT DISTR CABLE NETWORK, LT PANEL/ FEEDER PILLARS/ JUNCTION BOXES AND CONNECTED WORK UNDER GE, CLEMENT TOWN
2026_MES_771661_1
GE/CLT/ Of 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Clement Town
Class D Cat b(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹83,400
Yes
21 Jul 2026
12 Jun 2026
18 Jul 2026
12 Jun 2026
11 Jul 2026
27 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L in replacement of LT feeder piller box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93.
Incomming :- (a) MCCB , 400 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 630 Amps - Set of three.
b) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
c) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
d) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
e) CT Coils of suitable ratio -01 Set. | 2 | Each Job | - | - |
| 2 | M&L in replacement of LT feeder piller box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93
Incomming :- (a) MCCB , 315 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 500 Amps - Set of three.
a) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
b) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
c) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
d) CT Coils of suitable ratio -01 Set. | 2 | Each Job | - | - |
| 3 | M&L in replacement of LT feeder piller/junction box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93.
Incomming :- (a) MCCB , 250 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 315 Amps - Set of three.
b) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
c) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
d) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
e) CT Coils of suitable ratio -01 Set. | 2 | Each Job | - | - |
| 4 | M&L in replacement of LT panel box size (1.0X1.0X0.6 mtr) having outer shell thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93.
Incomming :- (a) MCCB , 250 Amps, 4P, 415V,25 KA - 01 Each, Al busbar of capacity 315 Amps - Set of three.
Outgoing :- (a) MCCB, 250 Amps, 4P, 415V, 25 KA- 01 Each
b) Digital Ammeter 0-400 A of size 96sqmm with selector switch-01 No.
c) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No
d) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.
e) CT Coils of suitable ratio -01 Set. | 2 | Each Job | - | - |
| 5 | Dismantling and taking down Unserviceable earthing and Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick burried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | - | - |
| 6 | Supply and Fixing in replacement MCCB TPN 400 Amps , 415 Volts, 50 KA ,4 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. | 2 | Each | - | - |
| 7 | Supply and Fixing in replacement MCCB TPN 250 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. | 2 | Each | - | - |
| 8 | Supply and Fixing in replacement MCCB TPN 200 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection all as per direction of Engr-in-Charge. | 2 | Each | - | - |
| 9 | Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc | 1,200 | RM | - | - |
| 10 | Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3½ core | 300 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_864096.xls
BOQ • 0.47 MB
Tenderdocs8108.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .