Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 15A PALMER BAZAR ROA D CAL 15 700015 | KOLKATA | WEST BENGAL | 700015 | ₹5.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹5.1 LRejected-AOC | ₹5.1 L | L2 | Rejected-AOC L2 |
| 3 | L3₹5.1 LRejected-Finance 1087 LASKARHAT KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | ₹5.1 L | L3 | Rejected-Finance L3 |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
13 Jan 2026, 12:00 pmClosed
D.G.(S and D)
Office of the Director General (Sewerage and Drainage), SEWARAGE and DRAINAGE department Kolkata Municipal Corporation 5, S.N. Banerjee Road Kolkata-700 013 West Bengal
INSTALLATION OF LED LIGHTING ARRANGEMENT FOR PROPER ILLUMINATION SYSTEM AT THE PUMP HOUSE AND PUMPING STATION COMPOUND WITH OTHER ALLIED WORKS AT DHAPA LOCK DRAINAGE PUMPING STATION.
2025_KMC_977435_1
KMC/S_D/DLPS/L/25-26
Open Tender
Electrical Work/ Equipment
10 days
DLPS/DHAPA
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10,000
9 Mar 2026
26 Dec 2025
15 Jan 2026
26 Dec 2025
13 Jan 2026
26 Dec 2025
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS. Earthing Installation – with Pipe Electrode : Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Legrand 8 way Enclosure (607717)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Legrand 4 way Enclosure (607715)
Laying on Wall / surface with Saddles / clamps.(b)Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 16.Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. (b) 250 x 250 x 100mm
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (a) Upto 9.0 mtr. long pole (i) 1st coat of aluminium paint over 1 coat of RO priming
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (a) Upto 9.0 mtr. long pole (ii) 2nd coat of aluminium paint over 1st coat
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm)
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. Crabtree 63 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Legrand 6-32 A SP
(H) Street lights :3. Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated & sheathed wire (single core) partly in GI conduit & partly through above bracket from OH line to the fitting, without control switch, incl. making connections and painting
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) (f) 50mm dia 3mm thick Polythene Pipe.
FAN: Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Exhaust fan (12")
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm No & dia. of wire in mm No of Core 10 1/3.55 4
Supply and delivery of 230V,50Hz Heavy duty Metal 12"exhuast fan.
Supply and fixing of greenline V2 street light (115 Wafl) complete with all accessories to be fixed/projected from the wall of the building or on pole incl. making holes /providing clamping arrangement & necy. GI reducer as required.S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Crompton, 120 watt... Rate as per IRRIGATION & WATERWAYS DEPT USOR (M&E) W.E.F. 10 MAY, 2022.
Supply and fixing of smart bright street light (36 Watt) complete with all accessories to be fixed/projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required.S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Philips, 36 watt... Rate as per IRRIGATION & WATERWAYS DEPT USOR (M&E) W.E.F. 10 MAY, 2022.
Supply Philips LED tube, model no: Mas LED tube 1200 mm 18 W 865 T8 I - 2100 lm... Rate as per IRRIGATION & WATERWAYS DEPT USOR (M&E) W.E.F. 10 MAY, 2022.
Opening the heavy duty following Exhaust fan/stand fan/cabin fan testing, checking, servicing and overhauling including supplying 1.5 sq.mm. PVC Copper flexible wire upto length 0.5 Meter. Including transportation charges etc.and refifling the same. Exhaust Fan/Stand Fan (24” or 60 cm. dia sweep)... Rate as per IRRIGATION & WATERWAYS DEPT USOR (M&E) W.E.F. 10 MAY, 2022.
Opening the following Exhaust fan (1 Phase/3 Phase) /Stand Fan/Cabin Fan testing, checking, Re-winding by supplying super enamelled copper wire of appropriate gauge, minalex paper, mica sheet, changing the loops, overhauling, becking, varnishing, re-fifling and testing and measuring r.p.m. etc.1-Ph Exhaust Fan (24” or 60 cm dia sweep).........Rate as per IRRIGATION & WATERWAYS DEPT USOR (M&E) W.E.F. 10 MAY, 2022.
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_2381747.xls
BOQ • 0.31 MB
FORM.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid