| 1 | L1₹18.2 LAccepted-AOC 6 STATION ROAD BERHAMPORE MURSHIDABAD WEST BENGAL 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.9 L+₹1.7 L (8.34%)Rejected-Finance 39 MAHESHMATI BANK COLONI MALDA WEST BENGAL | MALDA | MALDA | WEST BENGAL | 732101 | L2 | Rejected-Finance L2 | |
| 3 | L3₹22.4 L+₹2.2 L (10.7%)Rejected-Finance SARAT PALLY 95 97 BANK COLONY ENGLISH BAZAR MALDA WEST BENGAL 732101 | ENGLISH BAZAR | MALDA | WEST BENGAL | 732101 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
7 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Murshidabad Electrical Division
GOVERNMENT OF WEST BENGALOFFICE OF THE EXECUTIVE ENGINEER, MURSHIDABAD ELECTRICAL DIVISION, PWD184, C. R. DAS ROAD,BERHAMPORE, MURSHIDABAD, W.B-742101
Development of EYE ward and EYE OT at the Jangipur Sub-Divisional Hospital under Murshidabad District - SITC of AC Machine.
2022_WBPWD_435270_1
WBPWD/EE/MsdED/05/e-Q OF 2022-23 (2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Murshidabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹24,000
22 Mar 2023
19 Dec 2022
9 Jan 2023
19 Dec 2022
7 Jan 2023
21 Dec 2022
Amount
Supply of 3.8-4.0 Ton TR capacity floor standing(Tower) Air Conditioner machine of rated cooling capacity of 48000 BTU/hr (13.5KW) with 1/2 Nos. compressor(Rotary/Twin Rotary/Scroll), Rated power supply-415V(+/-5%)-3ph-50Hz. , Copper Condenser, Air-flow:-1200CFM. Refrigerant gas R410A/R32 (Make: Bluestar/ Hitachi/ Carrier/ Mitshubishi Electric/Daikin/Voltas) -Warranty for AC machines incl Compressor-3 years from date of commissioning
Installation of 3.8-4.0 Ton Tower AC machine on floor with MS Base Square shape painted including making hole on wall and fixing out door unit on suitable MS strauture on wall, making gas and liquid line connection, electric cable connection and drain pipe connection, making hole on wall, mending good to damages
Supply & installation of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall.
a) Liquid Line(9.52 mm OD with 0.6mm thick)
b) Suction line(19.05mm OD with 0.7mm thick)
Supply & fixing nitrile rubber tube Insulation on suction/liquid line copper pipe of concealed split AC.
a) Liquid Line
b) Suction line
Supply and delivery of 1.5 Ton SPLIT type room air conditioner machine having the following specification:- (a) Cooling capacity nominal (BTU):18000 (b) Star rating- 3 to 5 star. (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary, Condenser and evaporator- Copper Coil (e) Refrigerant : R32/R410A (f) Mini. Room Discharge air flow rate560 - 600 CFM. (g) Cordless Remote arrangement with all modernize provision of temperature setting,internal circuit should be covered by metal casing covering. Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years.(MAKE- Daikin/ Hitachi/Carrier) and the Split AC machine should be warranted for 3 years
Supply and delivery of 2 Ton SPLIT type room air conditioner machine having the following specification:- (a) Cooling capacity nominal (BTU):24000 (b) Star rating- 3 to 5 star. (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary, Condenser and evaporator- Copper Coil (e) Refrigerant : R32/R410A (f) Mini. Room Discharge air flow rate 780 - 850 CFM. (g) Cordless Remote arrangement with all modernize provision of temperature setting,internal circuit should be covered by metal casing covering Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years.(MAKE-GENERAL/ Daikin/ Hitachi/Carrier) and the Split AC machine should be warranted for 3 years
Installation testing and commissioning of 1.5 / 2 Ton split type AC machine on wall by appropriate mounting kit and testing whole refrigeration system with all joints, valves etc incl leak testing, supply and filling refrigeration gas, making hole in wall, mending good to damages
Supply and installation of Copper refrigeration pipe of suitable diameter, insulation of pipe by black kenefoam, tape joiting material, connecting IDU and ODU by 3 core 2.5MM Copper Wire for 1.5 Ton split AC machines as par direction of EIC
5/8" copper pipe.
1/4" copper pipe.
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, wall sleeves, hangers, supports, anchors - 25 mm dia
Reinstallation of existing dismantled 1.5 T Split Air Conditioner Machine
Pressure testing by 300 lbs with thushing method and cleaning with Esrochloride petrol and for cleaning moisture for inside as per direction of EIC.
Supply & charging R-410 gas for the whole unit of 1.5 Ton capacity Split type AC Machine as per direction of EIC by contractors own tools and skilled technicians.
Copper Refrigeration pipe line for Suction Line & Liquid Line (5/8 & 1/4" OD with 0.6 mm thick) supports & brackets for 1.5 Tr split Ac machine.
Supply & Fixing Pipe Insulation in Suction Line & Liquid line with 9mm Nitrile rubber tube for 4 Tr and 1.5 Tr Concealed split Ac Machine & 1.5 Tr Split AC Machine.
Control Cabling from Condensing Unit to Control Panel 3 Core 2.5 sq. mm. Communication Cable for 4 Tr and 1.5Tr Concealed Split AC Machine & 1.5 T split AC Machine. (Make:Finolex/Crystal/RR Cable)
Supply & laying PVC Drain Pipe 32mm dia.
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
Shifting of existing dismantled ERV Machine from 1 st floor roof top to 2nd floor roof top by hydra machine as required incl. all accessories / tools & tackels .
Re installation of existing dismantled ERV unit incl. planum chamber and other dismantled duct supplied departmentally and reinstall the same onthe roof top of 2nd floor of Eye Ot portion incl. Connection of existing plannem chamber and input/ out put duct with sperical case.
Suppiy installation And commissing of fabricated at site GSS sheet metal rectangular, round, ducting with complete with neoprene rubber gasket, elbow, splitter,damper, vanes, hangers,support etc as per approved drawing and specification of following sheet complete as required
Thickness 0.40 mm sheet
Duct thermal insulation by supplying and fixing of 19 mm thickness duly laminated aluminium foil of mat finisjhed closed cell nitrile rubber (class ''o'') insulation on existing duct after appling sutable adhesive for nitrile rubber tape insulation complete as per specification.
Supply & Installation of M.S. Table structure with legs made of 40 x 40 x 6 mm thick MS Anglewith proper wellding of suitable size for installion of outdoor units as required with proper fixing arrangement with roof top by means of suitable PCC foundation around the legs with the roof.
Supply and fixing automatic control box by 8 Way TPNDB (DBTPN006DD) double door with IP- 42/43 fixed by flushed on wall for control of 3 nos AC with following accessories, Make-L&T/Legrand. A) 32A TP MCB( 'ç' curve) ……. 3 no. B) Toggle switch on-off-on….3 nos C) 22A TP Contactor AC-3 3 nos D) LED Indicating lamp 3 nos E) Smart programmable Logic controller cat no-G7DDDT10 1 N. F) SP Preventer 1 No G) KUT terminal 12 nos H) nacessary connection by copper wire as required.
S & F 25A timer controller in SS double door phosphatised powder coated (12+2) way SPN DB, din rail with IP-43 protection with electrical accessories & front door locking arrangement with all connection, a) 240V 32A 4P Isolator (10kA, C curve)—1no, (Legrand) b) 240V 25 A TP MCB - 1No (Legrand) output c) Modular Contactors - 25A-2NO ,2 NC TP power contractor , MNX 25 (L&T) -1 no [ NS ] e) Daily & weekly programmable basis digital time switch, min switching time 1 min, 25 ON/OFF programs,6 yrs. Battery backup, settable DST & key pad lock features. Cat no. – 67DDT0. - 1 No [ NS ] f) (12+2) WAY SPN DOUBLE DOOR DB -1 no -Enclosure legrand (For AC Machine Timer) [ Legrand /Schneider/Seimens/ABB/ L &T ]
S & F 25A timer controller in SS Single door phosphatised powder coated 10 way SPN DB, din rail with IP-43 protection with electrical accessories & front door locking arrangement with all connection, a) 240V 25A DP MCB (10kA, C curve)—1no, (Legrand) [D-6/7] b) 240V 25 A SP MCB - 1 No (Legrand) [D-6/7] c)240V 6 A SP MCB- 1 No (Legrand) [D-6/7] d) Modular Contactors - 25A-2NO , AUMC2002501 (L&T) -1 no [ NS ] e) Daily & weekly programmable basis digital time switch, min switching time 1 min, 25 ON/OFF programs,6 yrs. Battery backup, settable DST & key pad lock features. Cat no. – 67DDT0. - 1 No [ NS ] f) 10 WAY SPN DOUBLE DOOR DB -1 no -Enclosure (607711) legrand [D-9/13] (For AC Machine Timer) &( one no Compound light timer) [ Legrand /Schneider/Seimens/ABB/ L &T ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the polythene pipe as per GS.(Finolex/Polycab/Gloster/RRKable/)
d) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [ 1 (Y) / E- 9 ]
d) 4x 6 sqmm + 2x 6 sqmm as ECC [ 1 (Y) / E- 9 ]
Supply and installation, testing & commissioning of 3 Phase ,415 Volt 50 Hz 5.5 TR , Twin Rotary Compressor, R 410 A refrigerant (ATE 690UC3Q9JK) Make- Hitachi ( as per sample) suitable for ductable split Air Conditioner Machine after dismantling the old, damaged , burnt out unserviceable compressor, incl. cutting, brazing welding charges incl. less cost of dismantled old compressor.
Charges for supply & fixing of Danforces Dyer as per sample.
Leak testing by Hard Nitrogen gas. With company own tools and skilled technicians.
Supply & charging R-410A gas for the compressor unit of 5.5 Ton capacity ductable type split AC Machine as per direction of EIC by contractors own tools and skilled technicians.
Vaccumisation charges for clearing moisture, dust etc from suction and delivery copper pipe line.
GITANJALI ELECTRONICS AND ELECTRICALS
M/S. M. R. ENTERPRISE
technical_863162.pdf
PDF • 0.76 MB
techsummary_863162.pdf
PDF • 0.73 MB
finance_863162.pdf
PDF • 0.62 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_863162.pdf
PDF • 0.42 MB
AOC.PDF
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .