Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.8 L+₹27,700.03 (1.50%)Rejected-AOC SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹18.9 L+₹40,509.76 (2.19%)Rejected-AOC 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹18.9 L+₹42,107.51 (2.28%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC Not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
REPAIR REPLACEMENT AND MAINTENANCE OF MISC E M SERVICES TO ELECTRICAL NETWORK SYSTEM ZONE III AT JOSHIMATH INCL AULI TAPOVAN AND MANA UNDER GE 871 EWS
2023_MES_622011_1
8764/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Joshimath Auli Tapovan Mana
as tender documents
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹40,000
Yes
3 Jan 2024
7 Oct 2023
11 Nov 2023
7 Oct 2023
4 Nov 2023
21 Oct 2023
Amount
Excavation in trenches n exc 1.5 metre wide and n. exc 1.5 metre depth in foundation or laying cables etc and getting out in hard dense soil all as specified and directed.
Excavation in trenches nexc 1.5 metre wide but depth exc 1.5 metre but nexc 3.0 metre in foundation or laying cables etc and getting out in hard dense soil all as specified and directed.
Returning and filling in including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick using excavated soil all as specified and directed
Removing excavated soil to a distance nexc 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable all as specified and directed.
M&L PCC (1:4:8) type D-2 (using 40 mm graded course stone aggregate) lean concrete below foundation of steel tubular poles including necessary form work for fair finished surfaces of concrete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete including necessary form work for fair finished exposed surfaces of concrete all as specified and directed at site.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work for fair finished exposed surfaces of concrete all as specified and directed.
Supply and fixing in repairs, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 185 sqmm 3.5 core all as specified & directed. Note: Excavation, earthwork and cable protection shall be measured and paid separately.
All as per Item No 10 here-in-before but of size 120 sqmm 3.5 core all as specified & directed.
All as per Item No 10 here-in-before but of size 50 sqmm 3.5 core
All as per Item No 10 here-in-before but of size 25 Sqmm 4 core
All as per Item No 10 here-in-before but of size 16 Sqmm 4 core
All as per Item No 10 here-in-before but of size 10 Sqmm 2 core
All as per Item No 10 here-in-before but of size 6 Sqmm 2 core
Supply and fix in repairs light grade galvanised mild steel pipe 80mm bore with all fittings, laid under road crossing, drain, paths, fixed to poles/ walls with suitable mild steel clamps, bolts, nuts and washers all as specified and directed as for cable protection all as specified & directed. Note: Excavation and earthwork shall be measured and paid separately.
All as per Item No 17 here-in-before but of size 50mm bore .
All as per Item No 17 here-in-before but of size 40 mm bore
Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor all as specified and directed.
Supplying, erecting and fixing in repairs of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type/size all as specified and directed. Note: Excavation , earthwork and PCC in foundation shall be measured separately.
Supply and fixing in replacement of street light fitting 48 watt LED, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 including 1.60 metres. long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts, nuts & washers and XLPE Cable to fitting all as specified and directed. Make:- Havells cat part No. ENDURACITYLITEPLAT+SL48WLED757PASYBOPC or equivalent of Phillips/Bajaj Note :-Rates quoted by contractor are deemed to be inclusive of 3 run of 1.5 sqmm pace insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified.
Supply and fix in repairs, commissioning from existing poles/buildings of any height/type of new LED flood light fitting 100 watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting etc complete fixed bracket made out by GI pipe (light grade) of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 4 sqmm from flood light to fittings connector all as specified and directed. Make:- Havells cat part No JETAIRISFL100WLED757ARWBLTG or equivalent of Philips/Bajaj
Supply and fix, “Lithium based Energy Efficient Integrated Solar Street Light of 50Watt” in Single FRP body with duly Polyurethane coating, encases with Monocrystalline Solar PV Panel of 90/95Wp with PIR Sensor , Lithium Battery 11.1/12.8V, 43.5AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution, CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 18-20kg including , suitable adjustable MS clamp , bolts , nuts and washers suitable for pole mounting etc complete as required and all as specified and directed. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Make:- Axxon Cart Part No: Axxon (AXN-50W) or equivalent to Bajaj / Philips/Polycab.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bars @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar, including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth wire and protection pipe beyond 7.5 metres will be measured and paid separately.
Supply, fixing in replacement, connecting and testing MCCBs in existing LT panel box/feeder pillar boxes (KIOSK) of capacity 160 Amps 4 pole breaking capacity 25 KA with thermal as well as magnetic balance adjustable type all as specified and directed.
All as per Item No 26 here in before but 63 Amps and 16 KA.
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, 20mm graded crushed stone aggregate of size 600X600X300mm including form work and plastering and two coat of white wash all as specified and directed.
M&L in replacement of earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 metre deep below ground level with top edge of the earth plate not less than 1.50 metre below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 40 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate)duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor/wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
S&F in repairs pole box size 300 x 250 x 150 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers all as specified and directed. Make : HPL, C&S, Gaurav
M&L for LT End joint kit for 120 Sqmm size 3.5 core cable including dismantling of existing complete all as specified and directed.
M&L for LT End joint kit for 185 Sqmm size 3.5 Core cable including dismantling of existing complete all as specified and directed.
M&L for LT End joint kit for 95 Sqmm size 3.5 Core cable including dismantling of existing complete all as specified and directed.
Supply and fix in repair stay assembly complete with accessories i.e. stay plate 300mm x 300mm x 6mm, galvanized thimbles, G.I. stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 on ser Page No.19-47 of MES Schedule Part-I all as specified and directed. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately.
M&L in repairs of broken earth pit of size 350x350x350 mm made of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site with testing result. complete all as specified and directed.
Supply and fix in repairs old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 50 sqmm including necessary connection all as specified and directed. Make : Axis/Dowells/Indiana
All as per item No 39 above but aluminium lugs of size 70 to 120 Sq mm. Make : Axis/Dowells/Indiana
S&F in repairs aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified and directed.
S&F in repairs galvanized iron strip 32 x 6 mm fixed with saddles & fixing screws, PVC dash fasteners, insulators fixed from test point to earth on walls or buried in ground /drawn into hume pipe. NOTE : Excavation & earth work shall be measured and paid for separately under relevant item of schedule all as specified and directed.
S&F in repairs second class hard wood wooden block of size 15x15x15 cm with hole of 8 cm depth & suitable dia for fixing of air termination rod of any size all as specified and directed.
S&F in repairs GI tubes light grade, galvanised iron, 20mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination all as specified and directed. NOTE : Excavation & earth work shall be measured and paid for separately under relevant item of schedule all as specified and directed.
Supply and fix in replacement of five pointed air termination Aluminium rod 12mm dia, 300 mm long all as specified and directed.
S&F in repairs of test point terminal block made of gun metal or phosphorous bronze 75x75x25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90x90x90mm made of 1.6mm plain sheet and screwed to wall for protection of test point all as specified and directed.
M&L 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) including finishing the surface even and fair all as specified and as directed
Supply and fix in replacement Anchor clamp suitable for 70 Sqmm to 95 Sqmm cable as per site requirement all as specified and directed.Make:Sintex/Hansel/Legrand
Supply and fix in replacement suspension clamp suitable for 70 Sqmm to 95 Sqmm cable as per site requirement all as specified and directed.Make:Sintex/Hansel/Legrand
Supply and fix in replacement inline connector suitable for 70 Sqmm to 95 Sqmm cable as per site requirement all as specified and directed.Make:Sintex/Hansel/Legrand
Supply and fix in replacement cable protection suitable for 70 sqmm to 95 Sqmm cable as per site requirement all as specified and directed.Make:Sintex/Hansel/Legrand
Supply and fix in replacement dead construction suitable for 70 Sqmm to 95 Sqmm cable as per site requirement all as specified and directed.Make:Sintex/Hansel/Legrand
Supply and fix in replacement Junction sleeves suitable for 70 Sqmm to 95 Sqmm cable as per site requirement all as specified and directed.Make:Sintex/Hansel/Legrand
Supply and fix in replacement laying and testing of aerial bunched cable 1100 volt grade stranded aluminium conductor 4 core x 70 Sqmm, (three phase and one neutral), 50 Sqmm (insulated messenger), electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor including all fittings such as anchor clamp, suspension clamps, inline connector, cable protection and dead constructional as specified and directed. Make: Havells/Polycab/Finolex/Universal
Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia 40mm and inner dia 32mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. Make : Universal /Rax or equivalent
Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia 50 mm and inner dia 38mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. Make : Universal /Rax or equivalent
NOORI ELECTRIC ENGINEERING WORKS
JAGAT POWER ELCTRICAL
Bedi Refrigeration Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .