Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | singTender₹11.8 LAccepted-AOC | singTender | Accepted-AOC single tender |
Tender Value
₹10.8 L
EMD Value
₹26,903
Closing Date
3 Nov 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Assistant Executive Engineer,PWD,Special Buildings Sub-Division ,Thrissur.
Strengthening works
2022_PWD_517663_2
63/AEE/SPL/2022-23
Open Tender
Civil Works - Buildings
Item Rate
180 days
Viyyur
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹26,903
20 Jan 2023
27 Oct 2022
5 Nov 2022
27 Oct 2022
3 Nov 2022
27 Oct 2022
Amount
Strengthening works
OD88339/2021-2022:Chipping of existing plaster & loose / Delaminated concrete / material upto parent concrete surface from RCC Members i.e., Slabs, surfaces of columns & beams so that corroded reinforcement is exposed, propping the adjoining area with steel props, bracing & steel / timber runners with working platform as per design & pattern approved by the consultant / Employer with labour, machinery etc.,
OD88556/2021-2022: Drilling holes of 14mm dia for a depth of 100mm (average) into the concrete & fixing Nylon nozzles of 12mmdia 50mm length suitable for grouting low viscosity epoxy grouts EPOJET LV. The nozzles shall be fixed firmly using Ultra rappid setting mortar ADESILEX PG 4 SP as per the instruction of engineer in charge
OD88558/2021-2022:Injecting neat cement slurry of pumpable grade mixed with 5 % of plasticised expanding admixture STABILCEM as per the manufacturers specification through already pre fixed aluminium nozzles with a pressure of 2-3 Kg/ Sqcm till the nozzles refuses to take the further grout and finally cutting and removing the nozzles the next day and making good the surface using fast plugging compound as per the Engineer-in-charge.
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
OD88341/2021-2022:Providing & fixing 10mm dia Shear Connectors drilling holes of 14mm dia in the wall joints for a depth of 100mm & cleaning the drilled holes using powered air blowers & fixing the connectors using Epoxy accrilate Anchor system of brand MAPEFIX PE SF, from MAPEI as per drawings & specifications . The shear Connectors shall be welded to reinforcement for a minimum length of 50mm.
OD88344/2021-2022:Providing and fixing 25x25x1mm thick weld mesh over the entire treated wall of existing wall 120 cm wedth, welding with mapefix pe fixed rods as per Drawing and Specifications
OD88343/2021-2022:Providing & applying epoxy bonding Coat EPORIP of MAPEI on to the top of existing surface before placing 50mm thick average Mapei T40 mortor , as a bond coat as per manufacturers specification. (on above existing concrete surface) The product must comply with the minimum requirements of EN 1504-4 and have the following performance characteristics: Workability time (EN ISO 9514) : 60’ (at +23°C) Linear shrinkage (EN 12617-1) (%) :0.02 (at +23°C) 0.10 (at +70°C)
OD88560/2021-2022:Supply and application of two-component, solvent-free, fluid, medium-viscosity epoxy adhesive, applied by casting to carry out monolithic repairs and structural consolidation of cracked concrete. Apply the resin after adequate preparation of the substrate (not included) by removing all crumbly or detached areas and all traces of cement laitance, stripping oils and paint by sandblasting or brushing. Open cracks less than 0.5 mm wide and carefully clean with compressed air to remove all traces of dust (not included).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD88565/2021-2022:Providing and laying M-55 grade micro concrete using 40% 12mm down size aggregates laid in position without steel reinforcement and shuttering in all respects as per drawings & specification, including curing , machine mixing & pouring etc
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
OD88598/2021-2022:Random rubble masonry using departmental rubble with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
6.4.1:Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
22.6:Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
14.43:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
14.53.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
14.54.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
OD88338/2021-2022:Engaging coolie
OD88340/2021-2022:Engaging carpenters
OD88695/2021-2022:Engaging Plumber for maintenance of plumbing work.
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
Bidder Name
Joy John Parappilly
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_749085.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .