GE NW NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBA
PROVN OF ELECTRIC PANEL FOR REDISTRIBUTION SYSTEM NEAR AM BLDG AND AUGMENTATION OF EXTERNAL ELECTRIC SUPPLY NEAR AW AND AN BLDGS AT NEW NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2020_MES_314535_2
8312/E8
Open Tender
Electrical Maintenance Service
Works
180 days
GE NW NAVY NAGAR
As per tender documents
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR
₹80,000
6 Jun 2020
7 May 2020
28 May 2020
7 May 2020
27 May 2020
14 May 2020
7 May 2020 - 20 May 2020
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out for laying of cables, in any type of soil.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm with excavated soil all as specified and directed.
Removing excavated material out side MD land complete all as specified.
Supplying, filling, spreading, leveling in layers and well ramming dry river sand around cable in trenches for cable cushioning all as specified and directed. Note : Punned thickness shall be measured and paid.
Cutting existing road surface or hard standing,bituminous topping 15 cm but n exc 30cm. girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
Supply and laying un-reinforced pecast concete cable covers LV type 1, flat size 250mm x 150mm x 40 mm .
M&L for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), 75 mm thick for copping and finished surface.
M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250 X 250 mm, having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including laying over 50 mm thick sand bed compacted complete as specified and directed.
Supply, laying Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric cable with aluminium conductor laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge. Note : Excavation and earth work, protection of cable shall be measured and paid separately.
240 sqmm, 3.5 core
150 Sqmm, 3.5 core
95 sqmm, 3.5 core
50 sqmm, 3.5 core
35 sqmm, 3.5 core
M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 , 50mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 , 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for GI pipe, light grade 50mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for GI pipe ,light grade 80mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for LT FPB, weather proof, vermin proof, both sidedouble door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, copper busbar strip with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl grouting, PCC work and foundation 60 cms above the ground level in PCC 1:3:6 type C2. all as specified & Directed consisting of following :-
S&F MCCB 400 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 422007 of Make- Legrand or equivalent in Siemens/Schneider.
S&F MCCB 250 Amps, 3 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420209 of Make- Legrand or equivalent in Siemens/Schneider.
S&F MCCB 100 Amps, 3 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 02 Nos, Cat No- 420045 of Make- Legrand or equivalent in Siemens/Schneider.
S&F MCCB 63 Amps, 3 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420003 of Make- Legrand or equivalent in Siemens/Schneider.
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S & F Copper Bus bar of suitable size, all are in equal size - Set 1(R, Y, B, N)
Supply, install, testing and commissioning of LT panel indoor type made out of 2mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, both side opening hinged door with locking arrangement powder coated, individual compartment for MCCBs and individual compartment for three MCCB blank , indoor type suitable for 3 phase, 4 wire, 415 volts and 1600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary framework and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
S & F D/O DMX -SP ACB 1600 Amps, 4 Pole, 50 kA compact in size and mp2 release - 01 No, Cat No- 669546 of Make- Legrand or equivalent in Siemens/Schneider. (i) No LCD protection unit, LSIG Frame 1600/2000 -01 Nos, Cat No- 028168 of Make- Legrand or equivalent in Siemens/./Schneider. (ii) Motor operator 220-250V A.C/D.C DMX2000 -01 Nos,Cat No- 028123 of Make- Legrand or equivalent in Siemens/./Schneider. (iii) Closing coil 220-250V A.C/D.C DMX2000 -01 Nos,Cat No- 028129 of Make- Legrand or equivalent in Siemens/Schneider. (iv) Shunt trip 220-250V A.C/D.C DMX2000 -01 Nos,Cat No- 028134 of Make- Legrand or equivalent in Siemens/Schneider. (v) Under voltage release 220-250V A.C/D.C DMX2000 -01 Nos, Cat No- 028139 of Make- Legrand or equivalent in Siemens/Schneider.
S&F MCCB 400 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 422007 of Make- Legrand or equivalent in Siemens/ Schneider.
S&F MCCB 200 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420218 of Make- Legrand or equivalent in Siemens/Schneider.
S&F MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 02 Nos, Cat No- 420055 of Make- Legrand or equivalent in Siemens/Schneider.
S&F Copper Bus bar 1600 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia light grade for earth lead and 20mm medium grade GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
M&L of aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductor above ground.
M&L for LT FPB, weather proof, vermin proof, both sidedouble door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, copper busbar strip with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl grouting, PCC work and foundation 60 cms above the ground level in PCC 1:3:6 type C2. all as specified & Directed consisting of following :-
MCCB 250 A, 4 Pole, 36 KA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420248 of Legrand or ABB/L&T/Schneider (incoming).
MCCB 160 A, 3 Pole, 25 KA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420047 of Legrand or ABB/L&T/Schneider
MCCB 100 A, 3 Pole, 25 KA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420045 of Legrand or ABB/L&T/Schneider.
MCCB 63 A, 3 Pole, 16 KA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420003 of Legrand or ABB/L&T/Schneider.
MCB DP 40 Amp,10 KA - 03 Nos, Cat No- 408637 of Legrand or ABB/L&T/Schneider
S&F Copper Bus bar 300 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
Plain cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling, 150 mm thick as in sub base surface finished fair and even comlpete all as specified
M&L for GI pipe, light grade 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M & L for High density polyethylene (HDPE) pipes of pressure rating 4kgf/sq. cm, 90mm dia with required bend and fittings for cable protection of cable above or below ground surface all as specified and directed.
Supply and installation of single phase Ac static energy (10-60A) direct current without box class 1.0 keypad based prepayment electronic energy meter with customer interface unit (CIU) and Soft Token Transfer Device (STTD), comprising of 1 No prepayment meter + 1 No CIU + 1 No STTD. Make : HPL cat No PSPB1523111000OC01 or equivalent in L&T secure.
Supply and installation of GPRS modem with following features :- (a) GPRS communication capabilities. (b) Built in SMPS power supply from 90 to 470V AC (single and three phase operation). (c) Automatic AT interfacing and GPRS enabling. (d) Remote modem configuration using GSM-SMS with configured master mobile number. (e) Operating temperature-10 to + 60°C. (f) Operating Humidity upto 95% RH (Non condensing). (g) Including provision of sim card.
M & L for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting GI strip 25 x 3 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of GI nuts, bolts as per connecting to equipment with provn charcol and salt complete all as per electric plate No 3 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
Supply, protection install, testing and commissioning of indoor type totally enclosed Vacuum Circuit Breaker suitable for 11KV, 800A, 350 MVA,18.4 KA(for 1 sec operation, equipped with CT, PT and protection relays horizontal isolation and horizontal drawn out cassette type and internal arc tested for 25KA for 0.1sec having IP 4X degree of manual/motarised spring charging mechanism. The auxilary voltage supply metering device/relay shall be 24V DC, where as for breaker spring charging mechanism the voltage will be 230V, AC complete as incomer panel including suitable foundation complete with the following equipments:- Make: Schneider/ABB/Siemens/L&T.
Vacuum circuit breaker suitable for 11 KV, 630A, 18.4KA operation.
Cast resin type dual core copper wound Current Transformer having 15 VA burden class 1.0 accuracy for metering core 5P10 for protection purpose (3 No with each VCB), having CT ratio 200/100/5A.
Drawn out 3 phase cast Resin copper wound Potential Transformer of ratio 11KV/110V having class 1.0 Accuracy, 100VA per phase capacity shall be mounted below the incomming breaker chamber.
Microprocessor based numeric relay with combined 3 O/C+ 1E/F having IDMT and instantaneous setting with communication and current measuring facility.
Master trip relay.
Digital load manager capable for measuring voltage, line current, Active-reactive currents, power factor, frequency and maximum demand.
LED type indication lamp for CB open/closed/spring charged auto trip/ trip circuit healthy. Note:- (i) Existing foundation shall be used however rates quoted shall be inclusive of making disturbed surfaces good. (ii) Control cable & connection from transformer to VCB panel shall be deemed to be included in the quoted rate.
Audio alarm through hooter with accept/reset button.
Anti pumping relay.
Panel thermostat rated for 230V, AC.
Panel illumination lamp LED.
Panel space heater
T/N/C Switch for breaker operation.
Buchholz relay. Make : Areva/Schnider/ABB/Siemens. NOTE : (i) The contractor shall submit a preliminary drawing showing arrangement of panels, type of Relays etc for approval of GE. (ii) The Equipment shall be tested in the presence of representative of Accepting Officer for successful Routine tests as per IS before receipt at site at OEM premises. (iii) Commissioning tests will be carried out in the presence of Engr-in-Charge and Electrical Inspector of the Department. (iv) Panel manufacturer shall be OEM not their vender/system Houses. (v) The make of the relays shall be of AREVA/SCHNEIDER. (vi) Width of the panel shall not be more than 540mm. (vii) VCB shall be complying to "M1" & "E1" category of latest IEC. (viii) VCB shall confirm to IEC : 62271-100 & panel shall be confirm to IEC 62271. (ix) One No PT's and one No power Pack shall be provided on VCB. (x) Necessary arrangement/adopter panel shall be provided for Bus-Coupling. Cost of any arrangement as required at site for installation of new VCB with existing VCB and shifting of cable etc complete as directed by Engineer-in-Charge shall be deemed to be included in the quoted rate.
Supplying, fixing, installation testing & commissioning of step down transformer, indoor type, 400 KVA double copper wounded with all standard fitting HT 11 KV 3 phase 50HZ LT 433 V three Phase 4 wire with off load tapping on HT side to vary secondary voltage to +/- 2.5% in step up 7.5% with limit as per IS: 2026 part-I, 1976) externally operated on/off circuit tap changing switch, locking arrangement 500KVA capacity transformer star delta as per vector group Dyn11 solid insulation class A, the temparature shall not exceed 50 degree centigrade measured by thermometer as per IS : 2026. The transformer shall be equipped with following:- Make: Kirloskar/L&T/Siemens
Externally hand operated off load tap changer switch with locking arrangement.
Oil conservator
Breath with Silica gel
Oil filter and drain valve
Oil level guage
Thermometer pocket
Diagram and rating plate
Air vent
Explosive vent
Lifting lugs
HT cable box suitable for connecting cable
LT cable box suitable for connecting cable
Four number of roller
Earthing terminal
Skids
First fill of oil Note:- New foundation for mounting of new transformer and duct for cable connecting of new transformer shall be made by the contractor as per requirement of site. The rate of new foundation, duct and making disturbed surface good shall be included in above quoted rate.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 sq mm.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 300 sq mm. (From Tfr LT side to ACB Panel. To be laid in Duct)
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
Test point terminal block made of gunmetal /phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw fixed complete all as specified and as directed.
NOEL ENGINEERS
Bidder Name
DHARMESH ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .