Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹14.8 L
EMD Value
₹29,500
Closing Date
27 Jun 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti vibhag Division Indora
Drilling lowering and development of 1 Notube well 150m Deep under JJM
2020_HPIPH_38044_1
IND-KNG-03-730
Open Tender
Civil Works
Item Rate
60 days
Indora
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
Yes
EE Indora
₹29,500
Yes
13 Jul 2020
12 Jun 2020
27 Jun 2020
12 Jun 2020
27 Jun 2020
15 Jun 2020
90 days
Amount
Transportation of Rig along-with allied accessories etc.complete including erection and levelling at site through all kind of roads,approaches field etc.in all leads and lifts upto site of work complete in all respect.
Drilling of bore as per specifications laid down in IS-2800-1991(Part-I) with uptodate ammendments,if any;with Rotary Rig or combination drilling Rig starting with 650-600mm.dia M.S.Pipe reduced to 450-400mm.dia M.S.pipe confirming to IS-4270-2001 with uptodate ammendments,if any in all kinds of soils,boulders,rocks, collapsible strata,saturated soil, artesian conditions including the cost of all consumables,stores, water, fuel, lubricants and other accessories etc.complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge
Drilling and lowering of M.S.casing pipes 650-600mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 0 to 30 Metres below ground level within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Drilling and lowering of M.S.casing pipes 600-550mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 30 Metres to 60 Metres below ground level complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Drilling and lowering of M.S.casing pipes 550-500mm. Dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 60 Metres to 100 Metres below ground level complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Drilling and lowering of M.S.casing pipes 550-500mm.dia confirming to IS-4270-2001 with uptodate ammedments if any of suitable sizes as mentioned above from 100 to 120 Metres below ground level complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Collection,preservations and display of suitable size sample box with top lid and locking arrangement till handing over of the Tube-Well to the Department complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Supply and lowering of IS-Marked Electric Resistance Welded Mild Steel slotted pipe 200mm.dia nominal size housing, 6.4mm.thick having outside diametre 329.10mm.screwed and socketted confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length, welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cuttings, threadings and welding of pipes etc.complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Supply and lowering of IS-Marked Electric Resistance Welded Mild Steel slotted pipe 200mm.dia nominal size housing, 6.4mm.thick having outside diametre 329.10mm.screwed and socketted confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length pipe should have 1040 slot per meter as per IS 8110-1985 of 75x1.57mm slot size welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cuttings, threadings and welding of pipes etc.complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Providing and fixing of MS centralized guides at suitable spacing for each tubewell as per IS-226-1991 with upto date amendments if any complete in all respect within all leads and lifts and as per the direction and satisfaction of the Engineer-in-Charge.
Supply, Lowering, Fixing and lowering in position IS-marked "Mild steel bail plug of 200mm/330mm dia meter with U-hooks as per 2800-1991 with upto date ammendments if any complete in all respect within all leads and lifts and as per the direction and satisfaction of the Engineer-in-Charge.
Providing fixing and lowering in position threaded iron cap with locking arrangement of approved design to prevent foreign matter from getting into bore hole as required complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Supply and packing of gravel consisting of hard quartz are other suitable material with an average specific gravity of not less than 2.5 not containing more than 2% by weight of thin flat are stangated pieces shall be of sub rounded grains with minimum anuglar are features of size 2.3.35mm shall be free from impurities such as safe sale mica felspar clay sand ditlome haematte and orgnice material as per IS-4097-1967 withupto date amendments if any around intake of tubewell with minimum thickness of should round screen generally 100mm to the entire depth of bore as per IS-2800 (Part-1) 1991 with upto date amendments if any complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Development of Tube-Well by backwashing method with Air Compressor of minimum 750CFM capacity Pumping pipe of 200mm. Size and Air line of minimum 65mm size or with other suitable method, till the Well is thoroughly developed as per Clause-4.2 of IS-11189:1985, with upto date ammendments, if any; complete in all respect within all leads and lifts & as per the direction & satisfacton of Engineer-in-charge.
Development of Tube-Well by continuous over Pumping method with V.T.Pumps/Submersible Pumps of suitable capacity not less than double the discharge established by the Compressor method/design discharge, untill the well sand free as per IS-11189:1985 with uptodate ammendments, if any; complete in all respect as per the directions of the Engineer-in-Charge. The draw-down and discharge to be established by running the VT/Submersible pump continuously for 8 Hours in the presence of the officer not less than the rank of the Assistant Engineer.
Testing the vertcality of the Tube-Well as per Clause-4.3 of IS-2800(Part-II)-1979 with uptodate ammendments, if any, using plumb or plunger 6mm.smaller in dia within the inside diameter of the Well casing. The result of the verticality test shll be recorded on proforma shown in Appendix-A of IS:2800(Part-II)-1979 with uptodate ammendments, if any as appended with the tender documents.
Dismentalling of Rig or other allied, accessories after completion of job complete in all respect.
ABTAR SINGH AND COMPANY
H.N.SINGH AND COMPANY
M/S. Mast Ram Jaswal And Co.
M/S Sharma Enterpirses
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .