GE (AF) Jamnagar No1
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR/MAINT OF DG SETS AT VARIOUS LOCATION UNDER GE (AF) JAMNAGAR NO 1
2024_MES_655730_3
8280/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jamnagar
As per NIT
6 documents required · 6 mandatory
₹500
GE AF Jamnagar No 1
₹40,000
Yes
20 Mar 2025
11 Sept 2024
4 Oct 2024
11 Sept 2024
3 Oct 2024
19 Sept 2024
Amount
Maintenance and servicing of 500 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'B' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed NOTES: (i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall inclusive of servicing/ maintenance of the above said fittings
(ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set along with connected Alternator and Panel Board ,AMF shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs (iii) Spare parts, engine oil and radiator coolant oil required for replacement during the maintenance period shall be measured and paid separately as supply & fix.
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item,contractor to be provided fuel filter, oil filter, water filter,top head gaskets,fuel pipes, battery terminal & battery lead. (v) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications.
All as per Item No .1 here in before but for 400 KVA DG set
All as per Item No .1 here in before but for 320 KVA DG set
All as per Item No .1 here in before but for 250 KVA DG set
All as per Item No .1 here in before but for 200 KVA DG set
All as per Item No .1 here in before but for 160 KVA DG set
All as per Item No .1 here in before but for 100 to 125 KVA DG set
All as per Item No .1 here in before but for 70 to 83 KVA DG set
All as per Item No .1 here in before but for 50 to 63 KVA DG set
All as per Item No .1 here in before but for 25 to 30 KVA DG set
All as per Item No .1 here in before but for 10 to 20 KVA DG Set
Repair / overhauling of following mentioned Self Starter assembly of DG Set by disconnecting and removing from the engine, cleaning of all accessories, replacing of worn out parts such as brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and re-assembling the same and re-fixing into the engine including testing all as per manufacturer's instructions and as directed. (a) Self starter assembly, 24 Volt DC 250/320/400/500
All as per item No 12 above but Self starter assembly, 24Volt DC 160/180/200
All as per item No 12 above but Self starter assembly, 12Volt DC up to 100 kva
Repair / overhauling of following mentioned radiator assembly of DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc. all as required and as directed. Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges. (a) Radiator assembly320/ 400/500 KVAcapacity
All as per item No 15 above but Radiator assembly 160 to 250 KVA capacity
All as per item No 15 above but Radiator assembly 30 to 125 KVA
Supply and Fix in repairs Lead acid battery, 12 volt, 180 AH
Supply and Fix in repair Lead acid battery, 12 volt, 150 AH
Supply and Fix in repair Lead acid battery, 12 volt, 130 AH
Supply and Fix in repair Lead acid battery, 12 volt, 120 AH
Supply and Fix in repair Lead acid battery, 12 volt, 92 AH
Supply and filling Engine oil SAE 20W-40W. Make :- VOLVOLINE/ IOC/HP
Supply and filling radiator coolant Make : VOLVOLINE/ IOC/HP.
M&L for distilled water (electrolyte ) to be filled in lead acid batteries all as directed.
Supply and Fix in repairs solenoid switch, 240 volts, suitable for 500/400/250/200/180/160 KVA DG set.
Supply and Fix in repairs solenoid switch, 240 volts, suitable for 83.5/75/70/62.2 KVA DG set.
Supply and Fix in repair solenoid switch, 240 volts, suitable for 10 to 50 KVA DG set
S&F in repairs Automatic voltage regulator (AVR) Suitable for DG Set 500/400/250/200/180/160/100 KVA
S&F in repairs Automatic voltage regulator (AVR) Suitable for DG Set 10 to 83 KVA
Supply and fixing in repairs Battery charger panel mounted 24 volt 15 Amps suitable for AMF Panels of DG Set 100/125/160/200/250/400/500 KAV capacity
Supply and fixing in repairs Battery charger panel mounted 12 volt 15 Amps suitable for AMF Panels of DG Set 10 to 83 KVA KAV capacity
Supply and fix in repairs fan belt as per existing make for the following capacities of DG sets. (a) 250 to 400KVA
All as per item No 33 above but 200/180/ 160 KVA
All as per item No 33 above but 125/100 KVA
All as per item No 33 above but 70/ 75/82.5 KVA
All as per item No 33 above but 10 to 63 KVA
Supply & fix in repairs Air filter element as per existing make for the following capacities of DG sets. (a) 400/500 KVA
All as per item No 38 above but 320 KVA
All as per item No 38 above but 250 KVA
All as per item No 38 above but 200 KVA
All as per item No 38 above but 160 KVA
All as per item No 38 above but 100 t0 125 KVA
All as per item No 38 above but 70 KVA to 83 KVA
All as per item No 38 above but 50 KVA
All as per item No 38 above but 25 to 30 KVA
All as per item No 38 above but 10 to 20 KVA
Overhauling the fuel injection pump assembly and injectors, disconnecting the fuel supply lines, and taking out Fuel Injection Pump (FIP) to workshop for servicing/repair, replacement the worn out/un serviceable parts like service kit, D-Valve, Elements, nozzles etc., as required and calibrating the same, assembling at site and testing on load all as directed for the following capacity of Gen sets:- (a) 500/400 KVA
All as per item No 48 above but 320 KVA
All as per item No 48 above but 125 to 250 KVA
All as per item No 48 above but for 10 to 100 KVA
Disconnecting the inlet and outlet supply of the fuel tank cleaning the tank internally by draining out the fuel into clean container , taking out the corroded sludge and foreign impurities ,cleaning with pressure water and air, drying the tank, preparing the external old painted surface of tank including steel platform /stand of fuel tank and painting the prepared surface with one coat of synthetic enamel paint of existing shade, including writing date of cleaning of fuel tank complete all as directed for the following capacity of Gen sets :-500/400 KVA DG set Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF)
All as per item No 52 above but 320 KVA .
All as per item No 52 above but 250 KVA .
All as per item No 52 above but 200 KVA .
All as per item No 52 above but 160 KVA .
All as per item No 52 above but for 63 to 125 KVA .
All as per item No 52 above but 10 to 50 KVA .
Supply & fix in repairs solenoid coil of self starter of 24V capacity of any capacity DG sets taking out of self starter and transportation to workshop is deemed to be included in quoted rate all as directed.
Supply & fix in repairs solenoid coil of self starter of 12V capacity of any capacity DG sets taking out of self and transportation to workshop is deemed to be included quoted rate all as directed .
M&L for repairs in Right / Left hand lock with catcher for acoustic enclosure (canopy) of any capacity DG sets all as specified & directed.
M&L in repairs for Dial type mechanical fuel level indicator for any capacity DG set complete all as specified & directed.
S&F in repairs 4 Pole, 32 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 03 and cat no.CS97011) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 63 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 12 and cat no.CS97014) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 95/100 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 22 and cat no.CS97017) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 125/130 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 23 and cat no.CS970118) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 160 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 32 and cat no.CS97020) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 200 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 33 and cat no.CS97021) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 225/255 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 34 and cat no.CS97022) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 325 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 41 and cat no.CS97023) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 400 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 43 and cat no.CS97025) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 600/630 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 45 and cat no.CS97027) or equivalent of make siemens/ABB
S&F in repairs MCCB 400 Amps, 4 pole, breaking capacity 35/36 kA with thermal Magnetic release range 320 Amps to 400 Amps, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repairs MCCB 250 Amps, 4 pole, breaking capacity 35/36 kA with thermal Magnetic release range 200 Amps to 250 Amps, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repairs MCCB 160 Amps, 4 pole, breaking capacity 25 kA, fixed type fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repairs MCCB 100 Amps, 4 pole, breaking capacity 25 kA, fixed type fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repairs indicating lamp LED type, size 22.5 mm voltage 240 V AC. fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repairs push button with element for PB1 - Engine start / PB2 - Engine stop / PB3 - DG contactor ON / PB4 - DG contactor OFF / PB5 - Mains contactor ON / PB6 - Mains contactor OFF, fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repairs Aux control relay with socket 3 C/O 12 V DC, 5 A fixing in existing AMF panel & connecting complete all as specified & directed . Make:- BCH / C&S / Havells / Simens / L&T
S&F in repairs amps meter digital type 0-400 Amps of size 96 mm x 96 mm, fixing in existing AMF panel & connecting complete all as specified & directed .
S&F in repair C T ratio 100 A Class of accuracy 1, VA 15, ring type fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repairs Digital type DC Voltmeter, 0 to 30 V DC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repairs Digital type DC Ammeter, 0 to 20 ADC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repairs Electronic type Hooter, supply voltage 12 V, DC flush mounted, suitable for DG set, fixing in existing AMF panel & connecting complete all as specified & directed .
Supply and fix in repairs MCB’s single pole 6-32 Amps, 415 volts with ‘C’ curve, fixing in existing AMF panel & connecting complete all as specified & directed .
Supply and fix in repairs Aux supply 12 V DC, voltage sensing relay 415 V AC fixing in existing AMF panel & connecting complete all as specified & directed . Make:- BCH / C&S / Havells / Simens / L&T
S & F in repair electronic controller for AMF panel of capacity 63 to 100 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed.
S & F in repair electronic controller for AMF panel of capacity 125 to 160 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed.
S & F in repair electronic controller for AMF panel of capacity 200 to 400 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed.
Dismantling of alternator assembly complete from DG set of capacity from 10KVA to 400 KVA and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with supper enameled copper winding wire of the same gauge and turn with proper class of insulation impregnated & baking, assembling and testing complete all as specified & directed by Engineer-in-Charge.
Supply & fix in repairs silencer assembly complete suitable for DG set cap 10 to 35 KVA
Meterial and labor to attending complaints in AMF panel, locating faults ,caliberating AMF controller panel and replacement of unserviceable parts , control wiring and components in AMF panel of DG set 10KVA to 500KVA and testing on completion , complete all as specified and directed Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts will be measured & paid separately
M&L for taking out fuel tank from 200 KVA DG Set, welding / brazing at all leakage joint to make leak proof & reinstalled as specified & directed .
Supply & fix in repairs AMF controller of 400 KVA DG Set of existing make complete all as specified and directed .
Supply & fix in repair AMF controller of 250/320 KVA DG Set of existing make complete all as specified and directed .
Supply & fix in repairs AMF controller of 160/200 KVA DG Set of existing make complete all as specified and directed .
Supply & fix in repair AMF controller of 63/100 KVA DG Set of existing make complete all as specified and directed by Engr-in-charge.
Supply & fix in repair AMF controller of 10/50 KVA DG Set of existing make complete all as specified and directed by Engr-in-charge.
Supply & fix in repairs 12V DC card 4 channel relay module for AMF panel of existing make complete all as specifed and directed by Engineer in charge Make :BGLI/PROCPM/SULZAR
Supply & fix in repairs 24V DC card 8 channel relay module for AMF panel of existing make complete all as specifed and directed by Engineer in charge Make :BGLI/PROCPM/SULZAR
Supply & fix in repair self starter 12V DC for DG Set of existing make complete all as specified and directed by Engr-in-charge. Make : Cumins/Kirloskar/Greaves
Supply & fix in repair self starter 24V DC Model no R-42 for DG Set of existing make complete all as specified and directed by Engr-in-charge. Make : Cumins/Kirloskar/Greaves
Meterial and Labor to repair/fabricating of silencer assembly and extending with existing size not less than 100mm with heavy grade GI pipe upto 4 mtr/sheet complete all as specified and directed by Engineer in Charge
Supply & fix in repair water pump for DG set of capacity upto 200 KVA DG set complete with existing make complete all as specified and directed by Engr-in-charge. Make : Cumins/Kirloskar/Greaves
Supply and fix in replacement of ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps complete all as specified and directed by Engineer in Charge
Supply and fix in replacement of rubber coupling for DG set of capacity up to 100 KVA all as specified and directed by Engineer in Charge
NOTE:-(i) Item No. 1 to 108 if any DG set and connected items becomes breakdown ,the contractor shall locate the problem/Fault at site within 12 hours on intimation by JE/Engineer-in-charge and ensure that the fault and rectified within 48 hours ,failing which an amount of Rs.200/- per hour will be recovered as penal recovery from any payment due to contractor after expiry of 48 hours.
MADHAV ENTERPRISE (BID ID -3127097)
RIDDHI ENGINEERING WORKS (BID ID -3127182)
rajengineers (BID ID -3114103)
Sukhi Electricals (BID ID -3121067)
S t modi (BID ID -3110442)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .