Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAdmitted-Finance INDUSTRIAL ESTATE PHASE III KHONMOH KHONMOH SRINAGAR JAMMU KASHMIR 191104 | 191104 | ₹4.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.9 Cr+₹13.3 L (2.77%)Admitted-Finance | ₹4.9 Cr+₹13.3 L (2.77%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Firm does not meet all required technical criteria. Hence found non-responsive. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Firm does not meet all required technical criteria. Hence found non-responsive. |
| 5 | Rejected-Technical INDUSTRIAL ESTATE PHASE III KHONMAH SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | - | - | Rejected-Technical Firm does not meet all required technical criteria. Hence found non-responsive. |
| Sl No | Description | Qty | Unit | M/s AQUA ENGINEERS AND FABRICATORS L1 | JMM INFRACON L2 |
|---|---|---|---|---|---|
| 1.00Prefab Shelters at HQ 55 RCC, Mulbek | |||||
| 1.01 | Design, supply and construction of prefabricated PUF insulated shelter of size 22.80m x 6.10m with covered verandah 1.80m wide for JCO’s living accommodation having 8 rooms with attached toilets including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as per drawing No. 1 & 4 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract. | 3 | Set | 33,45,000 ₹1,00,35,000 Lowest | 34,75,000 ₹1,04,25,000 |
| 1.02 | Design, supply and construction of prefabricated PUF insulated shelter of size 22.80m x 6.10m with covered verandah 1.80m wide including toilet block of prefabricated PUF insulated shelter of size 6.44m x 6.10m for OR’s living accommodation including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as per drawings No. 2, 3, 4 & 8 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract.. | 4 | Set | 40,25,000 ₹1,61,00,000 Lowest | 41,35,000 ₹1,65,40,000 |
| 1.03 | Design, supply and construction of Cook House cum Dinning Hall of prefabricated PUF insulated shelter of size 28.00m x 6.10m x 2.70m with covered verandah of size 15.88m x 1.77m x 1.77m on front side and of size 8.10m x 1.94m on back side as per drawing No. 5 & 6 including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract. | 1 | Set | 29,90,000 ₹29,90,000 | 29,88,000 ₹29,88,000 Lowest |
| 1.04 | Design and construction of septic tank of size 5.2m x 1.7m x 1.42m in RRM 1:6 with PCC 1:3:6 at bottom, RCC M20 slab at top, baffle wall (CM 1:3), plastering 1.2cm thick in CM 1:6, with two Nos man hole covers and ventilation pipe including soak pit of size 1.5m x 1.5m x 2.4m as per drawing No. 7 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract | 7 | Set | 2,40,000 ₹16,80,000 Lowest | 2,46,000 ₹17,22,000 |
| 2.00Prefab Shelters at Dett Drass HQ 55 RCC | |||||
| 2.01 | Design, supply and construction of prefabricated PUF insulated shelter of size 22.80m x 6.10m with covered verandah 1.80m wide including toilet block of prefabricated PUF insulated shelter of size 6.44m x 6.10m for OR’s living accommodation including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as per drawings No. 2, 3, 4 & 8 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract. | 4 | Set | 40,25,000 ₹1,61,00,000 Lowest | 41,35,000 ₹1,65,40,000 |
| 2.02 | Design and construction of septic tank of size 5.2m x 1.7m x 1.42m in RRM 1:6 with PCC 1:3:6 at bottom, RCC M20 slab at top, baffle wall (CM 1:3), plastering 1.2cm thick in CM 1:6, with two Nos man hole covers and ventilation pipe including soak pit of size 1.5m x 1.5m x 2.4m as per drawing No. 7 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract. | 4 | Set | 2,35,000 ₹9,40,000 Lowest | 2,39,000 ₹9,56,000 |
Tender Value
₹3.0 Cr
EMD Value
₹3.8 L
Closing Date
21 Oct 2025, 6:00 pmClosed
Chief Engineer, Project Vijayak
HQ CE (P) Vijayak, C/o 56 APO, Pin 931721
DESIGN AND CONSTRUCTION OF PREFABRICATED PUF INSULATED SHELTERS AT MULBEK AND DRASS UNDER 55 RCC / 762 BRTF PROJECT VIJAYAK IN THE UNION TERRITORY OF LADAKH (2nd Call)
2025_BRO_733852_1
CE(P)/VJK/08/2025-26
Open Tender
Construction Works
Item Rate
270 days
Mulbek at 55 RCC and Dett Drass
As per tender documents
8 documents required · 8 mandatory
₹0
₹3.8 L
Yes
HQ CE (P) Vijayak, C/o 56 APO
13 Jan 2026
4 Oct 2025
27 Oct 2025
6 Oct 2025
21 Oct 2025
13 Oct 2025
6 Oct 2025 - 11 Oct 2025
13 Oct 2025
Amount
Prefab Shelters at HQ 55 RCC, Mulbek
Design, supply and construction of prefabricated PUF insulated shelter of size 22.80m x 6.10m with covered verandah 1.80m wide for JCO’s living accommodation having 8 rooms with attached toilets including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as per drawing No. 1 & 4 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract.
Design, supply and construction of prefabricated PUF insulated shelter of size 22.80m x 6.10m with covered verandah 1.80m wide including toilet block of prefabricated PUF insulated shelter of size 6.44m x 6.10m for OR’s living accommodation including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as per drawings No. 2, 3, 4 & 8 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract..
Design, supply and construction of Cook House cum Dinning Hall of prefabricated PUF insulated shelter of size 28.00m x 6.10m x 2.70m with covered verandah of size 15.88m x 1.77m x 1.77m on front side and of size 8.10m x 1.94m on back side as per drawing No. 5 & 6 including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract.
Design and construction of septic tank of size 5.2m x 1.7m x 1.42m in RRM 1:6 with PCC 1:3:6 at bottom, RCC M20 slab at top, baffle wall (CM 1:3), plastering 1.2cm thick in CM 1:6, with two Nos man hole covers and ventilation pipe including soak pit of size 1.5m x 1.5m x 2.4m as per drawing No. 7 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract
Prefab Shelters at Dett Drass HQ 55 RCC
Design, supply and construction of prefabricated PUF insulated shelter of size 22.80m x 6.10m with covered verandah 1.80m wide including toilet block of prefabricated PUF insulated shelter of size 6.44m x 6.10m for OR’s living accommodation including foundation, electrical, plumbing & sanitary fittings of premium quality complete in all respects as per drawings No. 2, 3, 4 & 8 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract.
Design and construction of septic tank of size 5.2m x 1.7m x 1.42m in RRM 1:6 with PCC 1:3:6 at bottom, RCC M20 slab at top, baffle wall (CM 1:3), plastering 1.2cm thick in CM 1:6, with two Nos man hole covers and ventilation pipe including soak pit of size 1.5m x 1.5m x 2.4m as per drawing No. 7 and as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract.
JMM INFRACON (BID ID -3452279)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tender08retender.pdf
Tender Documents • 2.37 MB
BOQ_821675.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .