Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹20.4 LAccepted-AOC SILINDA CHAKDAHA NADIA PIN 741223 | CHAKDAHA | NADIA | WEST BENGAL | 741223 | ₹20.4 L | 1st | Accepted-AOC Ok |
| 2 | 2nd₹20.5 LRejected-AOC | ₹20.5 L | 2nd | Rejected-AOC Letter of Acceptance issued of 1st Lowest |
| 3 | 3rd₹20.7 LRejected-AOC LALPUR CHAKDAHA NADIA DISTRICT NADIA W B PIN 741222 | CHAKDAHA | NADIA | WEST BENGAL | 741222 | ₹20.7 L | 3rd | Rejected-AOC Letter of Acceptance issued of 1st Lowest |
Updated dates
Tender Value
₹20.4 L
EMD Value
₹40,850
Closing Date
6 Apr 2026, 2:00 pmClosed
Executive Engineer
Krishnagar Division, Social Sector, P.W.Dte., Kanthalpota, Krishnagar, Nadia
Repair and Renovation of Old Auditorium of Chemistry Department of Kalyani University at Kalyani, Nadia.-Phase-II
2026_WBPWD_1018700_2
WBPWD/SS/EE/KNG- 23(e)/2025-26
Open Tender
CIVIL WORKS
75 days
Krishnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹40,850
Yes
21 May 2026
6 Mar 2026
8 Apr 2026
11 Mar 2026
6 Apr 2026
11 Mar 2026
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor
Clearing compound premises of shurbs, plants, jungles etc.by cutting and removing as directed.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) Upto area 2.5 Sq.m,
Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary.
Spot application for insecticides using Aqua base spray for pest (for bugs, cockroaches, silverfish, spider, termites, mosquitoes) to walls and ceiling etc. with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical fixture,electrical lines including drilling holes in-places where source of termite is detected squirting chemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor area while actual work will be all walls ceiling, rack, partition and furniture).
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification]
Welding in M.S. structural work with gas or electric:Tack weld
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. With earth obtained from excavation of foundation.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] 1:3:6 proportion
250 mm thick Brick work with Fly Ash Bricks (250mmx125mmx75mm) as per IS 12894:2002 in cement mortar (1:4)In foundation and plinth
In superstructure, ground floor
125 mm. thick Flyash brick work as per IS 12894:2002 in cement mortar (1:4) in ground floor.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)25 mm to 30 mm shuttering without staging in foundation
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In ground floor.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/upto 4 m, JSW/JSPL/SHYAM/ SRMB/BMASL/ELECROSTEEL/SSL
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. With 1:6 cement mortar 20 mm thick plaster
15 mm thick plaster
With 1:4 cement mortar20 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 25 mm. thick
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineer-in-Charge. ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor]Gradation/ Progression Type
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Area of each tile above 0.09 Sq.mColoured decorative, Ground Floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab 0.6 to 1.0 Square meter.
Providing and fixing of 15mm thick Mineral Fibre Acoustic Ceiling Tiles of approved pattern and size 595mm X 595mm should be placed in the Grid module to form a False Ceiling with NRC value ≥ 0.6 Material class: A2-s1, d0 as per EN 13501-1, Fire: REI – REI120 as per EN 13501- 2, Surface Burning Characteristics: Class 1 or A as per ASTM E 84) with powder coated exposed G.I. grid suspension system (interlocking T-Grid, having load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit. All complete as per the drawing & directions of Engineer-in-charge.With 15 mm thick mineral fibre false ceiling tile (NRC ≥ 0.6 as per ASTM C 423 & Sound attenuation - 34dB as per EN ISO 10848)
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).In 10-12 Micron thickness Annodizing film: I) Natural white. Casement window (34 mm Depth series)Outer frame.
Mullion.
Shutter.
Glazing clip.
Cleat angle. (Non-annodized)
Fixed glazing. Top, bottom and side member.
Mullion.
Glazing clip.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick coloured / tinted / smoke glass.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II)coloured, toughened glass conforming to IS: 2553-1992 (part-II) (i) 6mm thick
For openable / Casement windowsEPDM / weather gasket for outer frame and mullion.
Supplying stainless steel functional hinge for casement window as per approved brand as directed by Engineer- in -charge. (Natural White)250 mm long
Supplying Heavy Duty Aluminium Handle (EBCO Type) (Natural White)
Labour charge for fabrication and installation of composite door, window , partitions made from annodized extruded alloy aluminium sections for the following units:-Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. In ground floor Openable / Casement window.
Fixed glazing.
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete.Upto 5 mm depth and 5 mm width (a) In ground Floor
Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineer-in-charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb.Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating. All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineer-in-charge. 2 hour Fire rated door double leaf of size (1470 mm x 2170 mm)
Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge.for leaf width upto 1100mm
Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN -1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charges.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50 micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section top and bottom member in dry-glaze sandwitch system, (unit wt. of top and bottom members: 0.375 kg/m & 0.69 kg/m) of approved brand and profile, EPDM quality rubber gaskets, anti dust tape, end closer "C" channel and 75 mm long Self tapping screw being drilled through the centre leg of the bottom section with nuts placed at 300 mm apart without anyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia & 3 mm thick washer etc complete strictly as per manufacturers specification and direction of Engineer-in-Charge. (Payment to be made on area of finished work) . In Roof:-Natural/ Blue/ Green/ Bronze/ Opal/ Metallic grey colourWith 4 wall 10 mm overall thickness (wt.1.75kg/sqm,Ugvalue being 2.5 W/m2K, Min. cold bending radius of 1500 mm)
Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)One Coat Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty : (Two coats) ii) Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primerSuper Protective 100% Acrylic Emulsion.
Painting with ready mixed red lead paint of approved make and brand Two coats
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary On steel or other metal surface :With super gloss (hi-gloss) - Two coats (with any shade except white)
Supply of Unplasticized Non-Pressure Polyvinyl Chloride (PVC-U) Pipes (SN 8, DSR 34) & fittings for use in Underground drainage and Sewerage system conforming to IS: 15328-2003Single Socketed 3 Meter Length (SN2); Rubber Ring Type200 mm
Plain Tee; (b) 160 mm
Labour for fitting and fixing Unplasticized non-pressure Poly Chloride (PVC-U) pipes for underground draniage and sewerage system (IS:15328,2003) including cost of jointing materals etc fitting and fixing all necessary specials, cutting pipes, cutting holes in wall or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (anf floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charges. (Payment will be made on centre line measurement of the total pipeline including specials)200 mm
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes:160 mm. Dia.
Shoe160 mm. Dia.
Bend 87.5 degree 160 mm. Dia.
Sanitary & Plumbing Works :-Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. 50 mm
Compact Compact Ball Valve with SS Handle For CPVC/ UPVC Fittings. (As per ASTM D 2467, Schedule 80 25 mm
Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand).
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
SPECIALTERMS.pdf
Tender Documents • 0.68 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
BOQ_2503434.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid