Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.6 LAccepted-AOC GOVERNMENT OF TRIPURA OFFICE OF THE EXECUTIVE ENGINEER DRINKING WATER AND SANITATION DIVISION UDAIPUR GOMATI DISTRICT TRIPURA | ₹4.6 L | 1 | Accepted-AOC AOC |
Tender Value
₹7.3 L
EMD Value
₹14,628
Closing Date
16 Mar 2026, 3:00 pmClosed
The Executive Engineer.
O/o the Executive Engineer, DWS Division, Ambassa.
Maintenance of CI/DI/PVC pipe line in/c construction of Sluice Valve chamber, hydrant post platform etc. complete at different existing DTW schemes under DWS Sub-Division Gonda Twisa
2026_CEDWS_71377_1
154/EE/PWD(DWS)/AMB/2025-26
Open Tender
Civil Works - Water Works
45 days
District
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹14,628
5 Jun 2026
9 Mar 2026
16 Mar 2026
9 Mar 2026
16 Mar 2026
9 Mar 2026
Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge.
A)For UPVC Pipe for new work a.In all kinds of soil i) For pipes not exceeding 90 mm dia
ii) For pipes exceeding 90 mm dia but not exceeding 300 mm dia
Charges for fixing and laying rigid UPVC pipes jointing with couplers, solvent cement including testing of joints complete ( excluding the cost of pipes, couplers, solvent cement which are to be issued from the department free of cost and specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in – charge.
Class - 3 ( working pressure 6.0 kg / cm2) i) 90 mm OD
ii) 110 mm OD
iii) 140 mm OD
Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
Class - 3 ( working pressure 6.0 kg / cm2) i) 40 mm OD
ii) 50 mm OD
iii) 90 mm OD
iv) 110 mm OD
v) 140 mm OD
Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately).
i. 15 mm dia.
ii. 25 mm dia.
Labour charges for repairing of leakage for CI/DI pipeline of various diameter by manual labour by hammering of old lead joints and other leakages of pipeline in/c excavation & refilling of the same as per direction of the Engineering-in-charge ( pig lead will be supplied by the department at free of cost).
a) 80mm dia
b) 100 mm dia
c) 150 mm dia
Charges for repairing of leakage in UPVC/HDPE pipe line with PVC coupler & solvent cement etc.in/c necessary earth excavation backfilling of soil as required after laying of pipeline , in layers not exceeding 200mm in dept in/c consolidating each deposited layer by ramming,watering etc.Complete as per specification & direction of Engineering-in-charge.
a)90mm OD
b) 110 mm OD
c) 140 mm OD
Charges for repairing of leakage in UPVC/HDPE pipe line with PVC coupler/GI Socket/GI Union & teflon tape or solvent cement etc. in/c necessary earth excavation backfilling of soil as required after laying of pipeline , in layers not exceeding 200mm in dept in/c consolidating each deposited layer by ramming,watering etc.Complete as per specification & direction of Engineering-in-charge.
a) 15 mm OD
b) 25 mm OD
c) 40 mm OD
Welding on CI/DI pipes, sluice valve etc by Gas or Electric plant including transportation of plant at site using light coated electrode with graphite based coating for welding cast iron without preheating (The electrode gives a nickel copper (monel deposit)) etc. complete as per standard design including pumping out water.
Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. External work.
i) 15 mm dia. nominal bore
ii) 40 mm dia. Nominal bore
iii) 50 mm dia. Nominal bore
Providing, fixing and laying fabricated UPVC socket / coupler confirming to IS:10124 (part-2) with solvent cement confirming to IS:14182 in/c testing of joints complete as per CPWD specification & direction of the Engineering-in-charge.
a) 90 mm dia
b) 110 mm dia
c) 140 mm dia
Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. (By manual means)
Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
i) 40 mm dia
ii) 50 mm dia
iii) 90 mm dia
iv) 110 mm dia
v) 140 mm dia
Providing,fixing and laying fabricated UPVC straight reducer confirming to IS:10124 (part-3)with solvent cement confirming to IS:14182 in/c testing of joints complete as per chapter-20 of CPWD specification & direction of the Engineering-in-charge.
a)110 x 90mm dia
b) 140 X 110 mm dia
c) 140 X 90 mm dia
Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
i) 90 x 90 mm dia
ii) 110 x 110 mm dia
iii) 140 x 140 mm dia
Providing, fixing and laying fabricated UPVC end cap confirming to IS:10124 (part-4) with solvent cement confirming to IS:14182 in/c testing of joints complete as per chapter-20 of CPWD specification and direction of the Engineering-in-charge.
a) 90mm dia
b) 110 mm dia
c) 140 mm dia
Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
a) 90mm dia
b) 110 mm dia
c) 140 mm dia
Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge
.i)15 mm dia
Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.
i. 15 mm dia
ii) 25mm dia
iii) 40mm dia
Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
i)15 mm dia
ii) 25mm dia
iii) 40mm dia
iv) 50 mm dia
Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
i. 25x15 mm dia
ii. 40x15 mm dia
iii. 40x25 mm dia
iv. 50x25 mm dia
v. 50x40 mm dia
vi. 80x40 mm dia
vi. 80x50 mm dia
Providing and fixing GI equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer-in-charge.
i. 15x15x15 mm dia.
ii. 25x25x25 mm dia
Providing and fixing GI Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer-in-charge.
i. 25x25x15 mm dia.
ii. 40x40x25 mm dia
iii. 40x40x15 mm dia
Providing and fixing GI. Nipple of medium class as per chapter 20 of CPWD specification and direction of the Engineering-in-charge.
i)15mm dia 150mm long
Providing & fixing brass ferrule with C.I. cover confirming to IS:2692 in/c. boring & tapping the main as per chapter 20 of CPWD specification and direction of the Engineering-in –charge.
a)10mm nominal bore
Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.
i. 15 mm dia PVC /plastic bib cock
Providing and fixing G.I. Full way valve as per CPWD specification and direction of the Engineer - in - charge.
i. 15 mm dia
ii. 25 mm dia.
ii. 40mm dia
Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
i) 80 mm P.N 1.6
ii) 100 mm P.N 1.6
iii) 125 mm P.N 1.6
iv) 150 mm P.N 1.6
Charges for fixing C.I. sluice valves with cap complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
80 mm dia PN-1.6
100 mm dia PN-1.6
125 mm dia PN-1.6
150 mm dia PN-1.6
Making supplying and fitting fixing of MS spindles in/c socket for sluice valve as per departmental sample
i. 80mm dia
ii. 100mm dia
iii.150mm dia
R/Mtc of different dia C.l sluice valves by providing and replacing complete with bolts, nuts rubber insertions elc as per direction of the Engineer-in-charge.
i. 80mm dia
ii. 100mm dia
iii.150mm dia
Labour charge for fitting foding of gland rope in Cl sluice valve of various dia (80 mm dia to 250 mm dia) as per direction of Engincer-in-Changs (Including the cost of gland rope, grease.nuts and bolts etc)
Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge.
i. 65 mm nominal bore
ii. 80 mm nominal bore
iii. 100 mm nominal bore
Providing & fitting fixing of MS flange ( 8 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.
a) 80 mm dia
b) 100 mm dia
c) 125 mm dia
c) 150 mm dia
Providing and fixing DI specials as per CPWD specification and direction of the Engineer - in - charge. G. D.I. Collar flanged socketted
a) 80 mm dia
b) 100 mm dia
c) 125 mm dia
d) 150 mm dia
Labour charge for clearing of clouded deposited iron in the PVC pipe of 140,110,90 mm dia pipe by chain lead pully system in/c disposal of iron from the site and thoroughly washing the pipe with water complete as per direction of the Engineer-in-charge.
Labour charge for clearing of deposited iron clouded in the CI pipeline of different dia (200mm, 150mm, 100mm dia) by chain pulley system including washing the pipe by water complete as direction of the Engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_72626.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.37 MB
DNIeT154.pdf
Tender Documents • 3.09 MB
BOQ_72626.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid