Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.8 L+₹1.3 L (4.54%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹29.2 L+₹1.6 L (5.93%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹29.4 L+₹1.9 L (6.78%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
6 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVISION OF DEFICIENT STORE ROOM AND ROTI MAKER MACHINE AT SHIPS GALLEY AT NAVAL BASE UNDER GE NAVY PORBANDAR
2023_MES_574060_1
9162/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
PROVISION OF DEFICIENT STORE ROOM AND ROTI MAKER MACHINE AT SHIPS GALLEY AT NAVAL BASE UNDER GE NAVY PORBANDAR
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹56,000
Yes
3 Apr 2023
9 Jan 2023
8 Feb 2023
10 Jan 2023
6 Feb 2023
24 Jan 2023
10 Jan 2023 - 23 Jan 2023
Amount
Surface dressing not exceeding 15 cm deep in hard and dense soil including cutting of bushes, sapling etc. complete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and reamming of bottoms, lift upto 1.5m, includig getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m coplete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out soft / disintegrated and disposal of excavated earth (ordinary rock) lead upto 50m and lift upto 1.5m coplete as specified and directed.
PCC 1:4:8 type D2 using 40 mm graded aggregate as in foundations, filling and mass concrete or complete all as specified and directed.
Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of horizontal surface area complete all as specified and directed.
Treating the at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and directed.
Treating the soil under plinth protection / ramp with anti termite emulsion at the rate of 5 litres per square metre of surface area,complete all as specified and as directed.
75mm thick PCC 1:3:6 , type C-2 using (20mm graded stone aggregate) as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1) complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footing plinth beams, bases for column etc. complete all as specified and directed.
RCC (Design Mix ) M- 30 (using 20mm graded stone aggregate),as in columns, pillars, piers posts & struts etc. etc. complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed .
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in chajjas complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in roof slab supported on walls, beams and columns in roofs complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm rocks complete as specified.
Removing of excavated mtrls out side MD land, exc 1.5km and n.exc 5km depositing where directed at complete all as specified and directed.
Use and waste of form work to sides of concrete, foundation, footings & plinth beams and similar works with rough finished surfaces of concrete in flat complete all as specified and directed.
Use and waste of Form work to sides of columns, square, rectangular, complete all as specified and directed.
Use and waste of Form work to chajjas, troughs and simiar items including edges complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup, ports, overhangs, etc. also splays between floors and beams complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) in Flat complete all as specified and as directed.
Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.,complete all as specified and directed.
Mild steel CRS 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips complete as specified and directed.
Stone walling superior quality dressed Porbandar type block masonary in CM (1:6), brought upto courses using same size Porbandar stone complete all as specified and directed.
Rendering 20 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed.
Rendering 5 mm thick on fair faces of brick work or concrete surfaces as on ceiling surface, facia and projection of slabs, and window projection, in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, including add WPC @3% of cement weight ( Dr Fixt /Cera /Krishna etc ) , finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Rate includes WPC & Polymeric membrane will be measured and paid separately)
M&L for water proofing treatment to existing RCC roof slab including preparation of surfaces parapet comprising with the following course of treatment/ specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.0 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (c ) Applying two coats of reflective Bituminous aluminium paint on top of APP membrane. Laying of Standard APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) including removal existing treatment , complete all as specified and directed by Engineer in Charge
Material & labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as spd and as directed by Engineer in Charge.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over chalk whitening preparatory to distempering complete all specified and directed.
Preparation of new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
Hard core of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 150 mm thick, watered and rammed to a true surface, before concerting or otherwise complete all as specified and directed.
100mm thick PCC 1:3:6 , type C-2 using (40mm graded stone aggregate) as in sub base complete all as specified and directed.
Vitrified Ceramic tiles size (600mm x 600mm) 10 mm thick (square / rectangular) area of each tiles exc 0.18 sqm not exceeding 0.36 sqm, as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
Vitrified Ceramic tiles size (600mm x 600mm) 9-10 mm thick (square / rectangular) area of each tiles exceeding 0.36 sqm but n.exceding 0.18, in floors etc. skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
Powder coated aluminium sliding windows/ventilator, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, aodised aluminium snap beading, screws etc. complete all as specified and as directed.
Plain solid, straight chowkats and frames of second class hard wood wrought framed rebated on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed.
Factory made 35mm thick, 2nd class hard wood , plain framed, panelled shutters, (two panel) with lock rail and, panels shall be of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed.
Preparation of new or previously untreated wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wooden primer complete all specified and directed.
300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed in repairs complete all as specified.
200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
150mm (Size of Handle in mm) Aluminium handles, cast type, anodised all as specified.
100mm Butt hinges medium weight, cold rolled, stainless steel, and fixed with screws or welded complete all as specified and directed.
5.5mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
Hydraulically aluminium extruded section body door closer regulated designation No. 3 universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg etc complete all as specified and directed.
Floor door stopper aluminium alloy body double tongue, anodised, with hard drawn steel spring, fixed in floor,140mm length complete all as specified.
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification & drawing complete all as specified and directed.
Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
4.8 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square n. exc 0.5 sq. m in each pane complete all as specified and as directed.
150mm long (Length of Bolt in mm) Aluminium anodised,barrel tower bolts of extruded section complete all as specified and directed.
150mm (Size of Handle in mm) Extruded aluminium alloy handles, fabricated type, anodised and fixed in repairs complete all as specified.
25mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
16mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
15mm bore fancy type CP brass Stop cock / Angle valve with wall flange fixed in repair / replacement complete all as specified.
Fancy type bib taps, long shank chromium plated cast copper alloy 15mm bore with crutch screwed down, complete all as specified and directed. Complete all as specified and as directed
CP Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed complete all as specified and as directed.
Vitreous china wash Hand basin size 550 x 400 mm including waste pipe and waste coupling chromium plated, brackets and cutting for and pinning in ends of brackets or errecting stand but excluding taps, chain and plug fixed complete all as specified and directed.
Vitreous China wash down water closet pan (European type) with P or S trap, snow white or white colour, fixing bolts, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc complete, excluding flushing cistern and flush pipe including seat cover complete all as spd and directed by engineer in charge.
Vitreous china urinal half stall type urinal completed providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic fulshing cistern with brackets, flush pipe, grating and union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
10 litres capacity PVC flushing tank, syphonic action type, high / low level, valveless, with PVC inlet ball valve, PVC flush pipe, float, chain and pull and suitable sized brackets including taking down / dismantling old unserviceable flush tank (any type) and disposing off complete all as specified and directed by Engineer in charge.
PVC (SWR) pipes, 75mm bore, single socketed, 2.50 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed
75mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed.
PVC (SWR) junction single, (Single T) equal or unequal of size 75mm complete all as specified and as directed.
PVC connections 15mm size 600mm long with PTMT nuts fixed in repair / replacement complete all as specified and directed.
PVC (SWR) pipes, 110mm bore, single socketed, 4 Kgf per Sqcm pressure, in any length with rubber ring joints, laid in trenches/ fixed to floor/wall/ ceiling with clamps complete all as specified and as directed.
PVC (SWR) branch piece, double (double Y), equal or unequal 110mm dia with rubber ring joints,, complete all as specified and directed
PVC (SWR) floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed
PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) 1000 Litre capacity, hoisted and fixed in position, with lid, tounge nipple for inlet, outlet connections etc. complete all as specified and directed
20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed min. wt. 20mm-210gm complete all as specified and as directed.
25mm long handle CPVC ball valve for 25 mm bore pipe fixing in CPVC pipeline by cutting of pipeline and fixing with necessary fitting and solvent fixed in repair / replacement complete all as specified and directed.
Reinforced cement concrete M-30 (B1 1:2:4), using 20mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
60 mm thickness, M-35 Grade Machine pressed precast concrete interlocking paver block factory made any shape and size confirming to IS 15658-2006 of complete (with grey cement and pigment) over and including 50 mm thick sand cushioning complete all as specified and directed.
Coloured glazed ceramic tiles in vertical / dado surfaces 300x200x7/350x250x7mm thick set and jointed in white or coloured cement to match laid over 15mm thick rendering in CM (1:4) complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
20 to 25 mm thick Kota stone slab of Ist quality, Machine cut, table rubbed and polished as in flooring laid over and including 20mm thick screed bed in cement mortar (1:4) set & jointed in grey cement slurry mixed with pigment to match shade of slab, including rubbing grinding and mirror polishing complete all as specified and directed.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:-
(a) One light or fan point controlled by one one way switch
(b) One ceiling fan/exhaust fan controlled by one way switch
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 5 pin 5 Amps and all as directed at site.
All as per above item No. 82 but One 5 Amps 3/5 pin socket outlet on same board with other switches.
Point wiring with 4 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for one socket outlet 15 Amps on independent all as directed at site.
Modular switch 1 way 6 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, hum free, AC, 230 volts, 120 watts, duly ISI marked complete all as specified & directed. Make: - Legrand, Cat No. 6755 30 or Havells, Cat No : AHLRFHW005 complete all as specified.
Supply and fixing ENDURA LINEAR NEO (4FT) 20 W LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod, complete all as specified and directed by Engr-in-Charge.
MCB DB Single pole and neutral 8 way double door IP-43, 230V having earthing terminal, with bus bar including making electrical incoming and outgoing connection with lugs/thimbles complete all as specified and as directed.
MCB DB Triple pole and neutral 4 way double door IP-43,230V having earthing terminal, with bus bar including making electrical incoming and outgoing connection with lugs/thimbles complete all as specified and as directed.
MCB TPN 40 to 63 Amps,10 KA breaking capacity 'C' Curve suitable 415 V,50 Hz for lighting and other domestic load fixed in repairs complete all as specified and directed.
MCB SP 240 Volts AC 6 - 32 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
MCB SPN 40 to 63 Amps,10 KA breaking capacity 'C' Curve suitable 240 V,50 Hz for lighting and other domestic load fixed in repairs complete all as specified and directed.
MCB TP 415 Volts AC 25-63 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (PVC Conduit shall be measured and paid separately).
Supply laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Double walled corrugated (DWC) HDPE pipe of size 63mm outer dia and 50mm inner dia conforming ot IS 16205 Part-24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair/replacement complete all as directed by Engr-in-Charge.
Exhaust fan 300mm sweep, metalic body with louvers, 1400rpm AC, 230 volts connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified & directed by Engr in charge.
AADESH CONSTRUCTION
BABUBHAI BHIMABHAI PANDAVADRA
RAJ ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .