Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
Repair and renovation of Ei work and compound illumination work at Bethuadahari Rural Hospital Nakashipara
2024_WBPWD_756512_1
WBPWD/EE/NED/Short NIQ/e-T/39/ (1st Call)24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,710
28 Sept 2026
24 Sept 2024
3 Oct 2024
24 Sept 2024
1 Oct 2024
24 Sept 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.a)Avg Run 5 mtr. a)Avg Run 5 mtr [5(d)/E-15]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Boar [4(a)/E-15]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[E-18/9-B]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting akelite/perspex cover and making necessary connections as required. [26/E-7]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc..( Only for the 1 Ph AC). [E-19/17]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc..[E-17/5(a)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [1(a)ii/E-14]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [1(a)iii/E-14]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [1(a)iv/E-14]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 25 mm size [7 b E- 16]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required A) 4x10 sq mm + 2x 6 sq mm [1d1/E-9]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 Sq mm [9 i ( F-5)]
4 Sq mm [9 ii ( F-5)]
6 Sq mm [9 iii ( F-5)]
10 Sq mm [9 iv ( F-5)]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
4 Way Enclosure(607913) [Up to 125A],[Make- Legrand/L&T/Siemens] , [15/D-11]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
125 A (Legrand /L&T/Siemens- make) [10/D-8]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
63A TPMCB (Make- Legrand/L&T/Siemens), [7/D-6]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment14 Way (formally was 2+12 way) enclosure(607712) (Legrand/ABB/L&T - Make) [13/D-9]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection 40A DP (Legrand/ABB/L&T - make)[6/D-9]
63A FP ( Make- Legrand/ABB/L&T) [6/D-5]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32A SP [7/D-6] ( Make- Legrand/ABB/L&T)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen 4 Way Enclosure(607715) (Legrand/ABB/L&T - Make) [14/D-10]
Supplying and fixing of 100/125 A 415V TPN with fuse on L&N Sheet steel Main Switches on angle iron frame on wall(L& T/Havells) [1b/D-1]
S&F AC machine timer for one no. machine febricated with double door 8Way SPNDB as per L&T Cat no-LTSDO8N) i) 240 V, 32A DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)-1no ii) 22A TP power contactor with 220 coil voltage (L&T, Cat no-MNX22-2P, CS90238)-1 No.iii) Digital timer switch (L&T, cat no-Crono 67DDTO)-1no. [N/S]
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab/Nicco/Fort Gloster] A) 150 Sq. mm 3.5CORE [NS]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [Page No F1/2(d)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.Upto 150 Sq mm for 4 core [7(d)/F-4]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.a)Upto 150 Sq mm for 4 core [8b(xv)/F-5]
Supply & delivery of 250V,100W LED Bulb (Crystal White) (Philips - make)
Supply & delivery of 4 ft 20 watt T-8 RETRO LED T-8 tube light with PC body.(Cat Ref.- LT8-8-865-2) (Make- Crompton/Philips/Havells)
Supply & delivery of Industrial Box type LED BATTEN for Twin 4 ft T-8 LED tube light (Make- Crompton , Cat no- IGP132LT8-16/Philips/Havells)
Supply & delivery of Industrial Box type LED BATTEN for Single 4 ft T-8 LED tube light (Make- Crompton , Cat no- IGP131LT8-16/Philips/Havells)
Fixing only lamp [11/C-2]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on Wall/ceiling.[22/D-13]
Supplying & Fixing Mirror/bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 9 watts GLS lamp complete set. [23/D-13]
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screw etc.[14a/C-2]
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. [15/C-2]
Supply 1200mm (48") sweep ceiling fans complete with all accessories having the following Model / Cat No. ( Aura Metallic -- New white Bronze) [ Make- Orient/Usha/Havells/CG ][NS]
Supply and delivery 250V 9" Exhaust fan (make- EPC/CG).[NS]
Supply& delivery of 230 Volt 400mm (16") wall-47 sweep heavy duty wall bracket fan (make- Orient/Usha/Havells/CG)
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [29/C-4]
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991) [30/D-14]
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)23 cm (9") [32b/D-14]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire [21a/C-3]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: A) 23 cm (9") [28a/C-4]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc [18a/E-6].
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board [20a/D-13].
Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil [1(a)/G-1].
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe [2(a)/G-1]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
Earth Continuity Conductor : Solid GI wire A)No. 4 SWG
Supply, Installation,Testing & commissioning of cubical type L.T distribution panel board of suitable sized,floor mounted compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2mm thick CRCA sheet steel with M/S angle frame .The panel board is to consist of the following switches . A) Incoming Arrangemet:(Open execution) i)Switch disconnector fuse(panel mounting cubical type)comfrom to IS 13947 TPN AC 23 A, 50 HZ,415 250 AMP with 3 nos 250Amp DIN type HRC fuse lin (make : L& T/Siemens/Hager)
B) Bus Section:- 500 V 415 electrolyte grade tinned copper bus bar with horizontal/vertical section of 4 No. Copper Bar 50mmx5mm size & 2 Nos 20x3 mm tinned copper strip for earth .A bus bar shall be fixxed with FRP chair & the entire bars are insulated with PVC heat sinkable sleeve of suitable size & color as per direction of E.I.C Busbar support insulator shall be class F type & made of Non-hygroscopic ,non-combustible , track resistant and hight strength FRP/SMC /DMC material & shuld have suitable sized and spacing to with -stand the dynamic stress due to short circuit currents.
(C) Outgoing arrangegement : (open execution type)(Make : L&T/Siemens/Hager) i) Switch disconnector fuse conform to IS: 13947 TPN AC 23 A , 50 Hz , 415 Volt with 3 nos 125 Amp Din type HRC fuse link------02Nos. ii)Switch disconnect or fuse fuse conform to IS:13947 TPN AC 23 A, 50 HZ ,415 Voil 63 Amp with 3 nos 63 Amp DIn type HRC fuse link---2 Nos. iii) Switch disconnect or fuse confrom to IS: 13947 TPN AC 23 A,50 Hz , 415 Volt 32 Amp with 3 32 Amp DIN type HRC fuse link---04 Nos
Inter Connection:- ALLinterconnection of switchsa & bus bar shall be made of 40mm x 6mm(for 315 A),30 x 6 mm(for 250A),25 x5 mm9for 200A0 ,multi strand PVC insulted copper wire to be kept for 35 sqmm (for 125A) ,16 sqmm (for 63 A),10 sqmm (for 32A0.Cable conection for main switches &Changes over (if necessary0 & the end of all connections of metering panel to be finish with copper socket by crimping method having Marked freeule for indication . Cable Alley: Cable entry arrangemet will be provided in the cubical panel in vertical position with 100AMp capacity 4 way AC/DC (make P>W.D approved )connector indication phase & neutral for ech outgoing main switches & glad plate plate must be placed at the bottom of panel with detachable type as per direction of EIC.
Painting : The complete panel board shall be painted by power coated after seven tank pretreatment process and the paint thickness will be 60 micron brand & color as per direction of E.I.c Constructural Details:- All incomimg & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front.All doors shall have Panl lock Arrangement .The panel shall be properly Gaskatted Door at front moisture & Remain.Busbar will be properly arrange & all Switches shall be fixted by M.S nuts & bolts On angle/flat iron frame base as per direction of EIC.
Compound Illumination
A)Street Lighting
Supply & installation of 5 mtr GI octagonal pole (Make Bansal/Utkarsh/Jindal/Skipper) as per dimension Top dia - 70mm,Bottom Dia-130mm,Section -1 (Section length -7000mm) Thick 3mm, Base plate 225mm x 225mm x 16mm PCD-225mm,FOUNDATION ACCESSORIES-Foundation G.I. bolt M20 x 700mm (4 nos), sword type arm bracket 1500mm long connected with GI bolt,templates and foundation RCC 1:1:5:3 shall be size of 550x550 mm and depth 1400mm with 8 nos 12mm dia tor bar as main bars and 8mm dia tor bar stirrups @ 190 mm c/c as per approved drawing
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below: For Soft Soil By ISI-Medium GI pipe
S&F 1 No. 4 way bakelite terminal AC/DC make & 1 No. 15 Amp. fuse base & bridge inside the cylindrical portion of the header assembly as per direction of E.I.C.
S&F 50 mm. dia 1.5 mtr. long detachable type Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC
Inter connection of LED light fittings by 2 x 1.5 Sq. mm. PVC insulated copper wire from pole loop box with best quality PVC pipes as per direction of EIC
Supply,Installation,Testing & commissioning of out door LED fitting with high power LED and unique peanut lens to ensure uniform distribution, higher spacing andsystem lumen (NOM) :10000 lumen i/c. wiring with 1.5sqmm FR Copper wire (Approx length: 10mtr) suitable for use with 230Volt 50Hz AC supply etc as required. ( Make: Philips Cat : BRP410 LED CW 072 MR FG S1 PSU GR or equivalent Model of Jaguar/Wipro) with submission of test report and warranty certificate for atleast 5 years from OEM.
Painting of steel Mini Pole of lengths and no. of coats of paintof white color, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole 1st coat of aluminium paint over 1 coat of RO priming and 2nd coat of aluminium paint over 1st coat as per GS
Timer Panel:Supplying and fixing (2+12)way Legrand DB enclosure for housing the following A) One no.single dial Digital Astronomical timer (Make Legrand/L&T/ABB/Siemens) B) One no. FP pole, conctractor,(L&T/ABB) C) One no. FP 63A MCB D) One no. auto/manual Toggel Switch and other required material The complete arrangement must be wiring by PVC insulated Cu wire as per GS
Supply , Installation & Testing & Commissioning of Decorative LED Post Top to ensure uniform distribution, i/c wiring with 1.5 sq.mm FR Coppe wire ( Approx. Length:4mtr) suitable for use with 230Volt 50Hz AC supply etc as required.( Make- Crompton Cat No :LPTO-40-CDL or equivalent Model of Philips/Jaguar/Wipro) with submission of test report and warranty certificate for atleast 5 years from OEM.
Supplying & Fixing CI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted CI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint [H-5/5]
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Finolex/ Havells/KEI/Polycab ].
4 core 16 sq.mm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. A)16 Sq mm for 4 core [7(d)/F-4]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. a)Upto 16 Sq mm for 4 core [8b(xv)/F-5]
Tulip Engineers Co-Operative Society Ltd. (BID ID -5653551)
S.B.ENTERPRISE (BID ID -5653333)
MITRA ELECTRIC (BID ID -5660111)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.42 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .