Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹41.4 L+₹23,739.20 (0.58%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹44.9 L+₹3.7 L (8.98%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹46.0 L+₹4.8 L (11.7%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 5 | L5₹46.1 L+₹4.9 L (11.9%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹57 L
EMD Value
₹1.1 L
Closing Date
18 Dec 2023, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
SPECIAL REPAIRS / REPLACEMENT OF LT OVER HEAD LINES WITH LT UG CABLES AND CONNECTED ITEMS AT CERTAIN LOCATIONS IN DOMESTIC AREA AT AIR FORCE STATION BIDAR
2023_MES_628163_1
85607/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF BIDAR
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AF BIDAR
₹1.1 L
Yes
6 Jan 2024
13 Nov 2023
20 Dec 2023
13 Nov 2023
18 Dec 2023
4 Dec 2023
13 Nov 2023 - 29 Nov 2023
Amount
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 240 sq mm 3.5 core complete all as specified and as directed.
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 185 sq mm 3.5 core complete all as specified and as directed.
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 120 sq mm 3.5 core complete all as specified and as directed.
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 70 sq mm 3.5 core complete all as specified and as directed.
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 50 sq mm 3.5 core complete all as specified and as directed.
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 35 sq mm 3.5 core complete all as specified and as directed.
Supply, lay and testing cable LT XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts (earth) grade, of size 10 sq mm 4 core complete all as specified and as directed.
Excavating in trenches in soft / loose soil not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 sqm on plan and n.exc 1.5 m in depth and getting out as I soft/ loose soil complete all as specified and as directed
Returning filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavted material n exc 50 m and depositing where directed at a level not exc 1.5 m above the staring point as soil complete all as specified and as directed.
M&L for Sand cushioning (dry sand) to under ground cable for cable protection in layers of 23cm thick ( 8 cm thick before laying of cable and 15cm thick after laying of cable) in trenches complete all as specified and as directed. Note :- Only puned layers shall be measured.
Supply and laying unreinforced pre cast concrete cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm for cable protection complete all as specified and as directed.
S & F 100 mm dia Galvanised steel tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road / floor etc for cable protection, complete all as specified and as directed.
S & F 80 mm dia Galvanised steel tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road / floor etc for cable protection, complete all as specified and as directed.
S & F 50 mm dia Galvanised steel tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road / floor etc for cable protection, complete all as specified and as directed.
M&L for Cutting the existing road of width 0.25 M x 0.6 M depth x 3.0 M length for laying the GI pipe light grade with all fittings such as bends, sockets, reducers union etc, complete of 80 mm dia as mechanical protection to LT cable including excavation in any type of soil, rfr , removal and PCC 1:4:8 of 15 cm below the GL for making the the road cut portion good complete all as specified and as directed. (Note :- GI pipe light grade with all fittings such as bends, sockets, reducers union etc, complete of 80 mm dia shall be measured and paid under the respective item )
Disconnection and Removing the unserviceable Aluminium Over head conductor from the LT Poles carefully along with all the jumpers and Aluminium binding wire complete all as directed
Disconnection and removing the insulators any type from LT poles. complete all as directed
Disconnection and removing the cross arms from LT poles. complete all as directed
Dismantling the earth chamber, Excavation and removing the unserviceable earthing materials along with unserviceable earth electrodes from the existing u/s earth pits pertains to installations/ buildings and M & L for providing earthing with GI earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth strip of 32x6 mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with50mm thick with 6mm dia MS bars complete all as shown in SSR Pt - 1 electrical plate No 3. Note : Quoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc complete all as specified and as directed.
S & F LT UG cable route indicator made out of cast iron of size Head dia 4'' with 25 mm x 25 mm x 3 mm thick 60 cm long MS support angle and painting of exposed surface and marked as "MES LT CABLE 1.1 KV" in brown colour letters on yellow background complete including necessary earrth work cement concrete 1:2:4 for embedding MS support as required at sitecomplete all as specified and as directed.
RAVINDRA BROTHERS
Om Construction
om sai enterprises
Rama Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .