Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹6.8 L
EMD Value
₹6,800
Closing Date
12 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Executive Engineer, Electrical (R&B) Sub Division, Jamnagar
Providing New DG set for backup power supply in taluka sevasadan bhanvad, Dist. Devbhoomi Dwarka
271954
08(E) of 2025-26
Open
Electrical Works
Works
Jamnagar
8 documents required · 7 mandatory · 1 optional
₹900
Yes
Deputy Executive Engineer, Electrical (R&B) Sub Division, Jamnagar
₹6,800
Yes
2 Feb 2026
2 Feb 2026
2 Feb 2026
12 Feb 2026
2 Feb 2026
Name Of Work :- Providing New DG set for backup power supply in taluka sevasadan bhanvad, Dist. Devbhoomi Dwarka
Sr.No Qty. Unit Description of Item Net Rate Rate in Word Per Amount
1 150.00 Mtrs. Providing and erecting ISI mark Medium class RIGID PVC PIPES of 33.33 Rupees Thirty Mtr.
following size complete to be erected on/in wall or ceiling erected Three and
with necessary PVC fittings & Junction boxes fixed with adhesive Thirty Three
solution & Clamps with following dia of pipes, in approved manner as Paisas Only
directed (b) 25 mm
2 150.00 Mtrs. providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 240.38 Rupees Two Mtr.
ISI marked stranded Copper conductor wire in following type of pipe Hundred Forty
to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor and Thirty
FRLS PVC insulated stranded wire of green colour for earth continuity
of following size (E) in existing pipe (h) 4 wire 6 sq. mm
3 2.00 Nos. Providing and erecting Approved make Four pole moulded case 6790.23 Rupees Six Ea.
circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having Thousand
normal current rating up to 25 A to 100A. with Fixed thermal & Seven Hundred
magnetic release suitable to work on A.C. supply 50 c/s. with all Ninety and
internal connections, spreader tinned copper & complete erected in
existing 16 G.M.S. housing.ICS=100% of ICU only Cat III
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No
3-4-1 to 3-4-12 (The Enclosures should be used of same company of
MCCBs to be used)
4 1.00 Nos. Supplying & erecting approved make Four Pole 415V change over 4785.38 Rupees Four Ea.
switch interior for panel mounting with operating mechanism A.C.23 Thousand
duty confirming to IS for (B)63 A Cat-III Seven Hundred
Eighty Five and
5 12.00 Nos. Providing & erecting 240 V MCB double pole switch for lighting Load 295.93 Rupees Two Ea.
(B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in Hundred
existing box having following capacity (B) 40 Amp. Cat-III Ninety Five and
6 4.00 Nos. Providing & erecting 415 V MCB Four Pole for Motor & Inductive 737.30 Rupees Seven Ea.
Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 Hundred Thirty
in existing box having following capacity (c)63 Amp. Cat-III Seven and
7 2.00 Nos. Providing and erecting Sheet Steel powder coated MCB distribution 629.23 Rupees Six Ea.
board - flush / surface mounted fitted with busbar, neutral link, earth Hundred
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without Twenty Nine
MCB to house appropriate nos. of MCBs.(The DBs should be used of and Twenty
same company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing(b) sheet steel double
door (IP-43) (i)4 way
8 2.00 Nos. Providing and erecting Sheet Steel powder coated MCB distribution 2339.16 Rupees Two Ea.
board - flush / surface mounted fitted with busbar, neutral link, earth Thousand
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without Three Hundred
MCB to house appropriate nos. of MCBs.(The DBs should be used of Thirty Nine and
same company of MCB to be used) suitable for(B) three phase
incoming and single phase horizontal type outgoing Per phase
isolation type (PPI) (b) sheet steel double door (i)4 way
9 6.00 Nos. providing and erecting Approved make RCCBs conforming to IS: 2235.13 Rupees Two Ea.
12640 and having sensitivity of 30 mA and Short Circuit withstand Thousand Two
capacity of 10 KA and suitable for operation on single phase 240 Hundred Thirty
V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component. for
Thirteen Paisas
following Max. rating erected as directed (ii) 40Amps. DP Cat-III
10 6.00 Kgs Providing and erecting required size Copper strip for earthing of H.T. 794.87 Rupees Seven Kg.
OCB / ACB/ Transformer, LT panel board, Motors etc. using copper Hundred
clamp. Ninety Four
11 3.00 Nos. Supplying & erecting in earthpit of minimum bore dia. 225mm size 7095.25 Rupees Seven Ea.
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Thousand
Technology as per IS 3043-1987 made of corrosion free hot dipped Ninety Five and
G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber
and heavy duty cover (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) & having
back filling compound of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted by
Agency. [B] For Electrical installation up to 11 KV located in other
than normal soil
0 0.00 0 i.e. Soft Rock, Marshy Soil etc. -Length of Pipe : 2 mtr -Back filling 0.00 0 0
Compound :1 no. Bag of 25 Kg.
12 30.00 Mtrs. Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 396.93 Rupees Three Mtr.
1.1 KV grade to be erected as directed of following size.(E) 12 core Hundred
2.5 sq.mm Ninety Six and
13 140.00 Mtrs. Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 284.82 Rupees Two Mtr.
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with Hundred Eighty
necessary clamps or in existing trench / pipe of following size of Four and
cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
14 12.00 Mtrs. Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 3576.41 Rupees Three Mtr.
multistrand Copper conductor for 1.1 KV. to be laid on wall with Thousand Five
necessary clamps or in existing trench / pipe at road crossing or Hundred
floor of following size of cables.(D) 3 1/2 core 70 Sq. mm ( 35 Sq. Seventy Six and
15 20.00 Mtrs. Making trench in Hard Murrum / Tar Road of suitable width of 90 cm 357.54 Rupees Three Mtr.
or required depth for laying any size of cable or locating the fault all Hundred Fifty
over the run and back filling the same and making the surface as Seven and Fifty
normal ground. (B) If additional machinery like hammer driller or JCB Four Paisas
16 30.00 Mtrs. Providing & laying approved make Double walled corrugated pipes 62.62 Rupees Sixty Mtr.
(DWC) of polyethylene(conforming to IS 14930 II )with necessary Two and Sixty
connecting accessories of same material at required depth in Two Paisas
existing trench for laying of cable. below ground / road surface for
enclosing cable (A)50 mm outer dia
17 9.00 Nos. Providing and, fixing heavy duty flange type brass double 75.75 Rupees Ea.
compression type cable gland with rubber ring for PVC insulated Seventy Five
armoured cable complete with out going tails, insulating tape etc for and Seventy
following size of cables. (B) 3 & 1/2 core 35/50 Sq. mm
Five Paisas Only
18 9.00 Nos. Solder less crimping type Aluminium lugs conforming to IS suitable 15.15 Rupees Fifteen Ea.
for cable of following size evenly crimped with high pressure tool & and Fifteen
connected to switchgear terminals with brass/cadmium plated nut Paisas Only
bolts in an approved manner. (C) 16/25 Sq.mm.
19 27.00 Nos. Solder less crimping type Aluminium lugs conforming to IS suitable 20.20 Rupees Ea.
for cable of following size evenly crimped with high pressure tool & Twenty and
connected to switchgear terminals with brass/cadmium plated nut Twenty Paisas
bolts in an approved manner. (D) 35/50 Sq.mm. Only
20 2.00 Nos. Solder less crimping type Copper lugs conforming to IS suitable for 12.12 Rupees Ea.
cable of following size evenly crimped with high pressure tool & Twelve and
connected to switchgear terminals with brass/cadmium plated nut Twelve Paisas
bolts in an approved manner. (C) 16 Sq.mm.
21 6.00 Nos. Solder less crimping type Copper lugs conforming to IS suitable for 22.22 Rupees Ea.
cable of following size evenly crimped with high pressure tool & Twenty Two
connected to switchgear terminals with brass/cadmium plated nut and Twenty
bolts in an approved manner.(E) 35/50 Sq.mm. Two Paisas
22 3.00 Sq.M Supplying and erecting HYLAM sheet on existing angle iron frame.for 2311.89 Rupees Two Sq.
trs. following thickness (F) 12mm Thousand Mtr.
23 1.00 Nos. Supplying and erecting, commissioning and testing of Diesel 412383.00 Rupees Four Ea.
Generating set confirming to IS: 4722:1968 & BS:5514 having Lacs Twelve
continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply Thousand
comprising of a totally enclosed air/water cooled diesel engine with
multi-cylinders developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for one hour in 24 hours
with standard accessories like fly wheel, lubricating oil cooler, "A"
class governor, heavy duty fuel wheel and lubricating oil filter, oil
bath air filler, lubricating oil pressure gauge, end exhaust manifold,
standard set of tools with adjustable spanners, screw drivers,
cylinder head to cover, joint cylinder head to exhaust, element lube
oil filter, 12 / 24 volts electric starting equipment complete with
standard heavy duty battery, dynamo, cut-outs, ammeter, necessary
wiring, pressure gauge, starter etc and heavy duty Residential type
exhaust silencer (With DEF System) and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of required
length, standard wall/floor mounted fuel with level indicator and
piping and drip proof alternator, self excited, self regulated, screen
protected, with excitation system,
capable of delivering the rated system output at 415 volts, 3 phase,
0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722-
1968 with voltage regulation +/- 5% of rated voltage from no load
to full load. Both the engine and alternator fitted on a common
fabricated steel base plate with antivibration mounting engine and
alternator both connected to each other by flexible flange coupling
and with floor/wall mounted control panel box comprising of
voltmeter ammeter, selector switches, ACB / MCCB / MCB of
adequate capacity, indicator lamps duly wired with HRC fuses. The
alternator & control panel shall be connected with provided suitable
capacity armoured cable and complete with Acoustic enclosure
(canopy) made out of 16 SWG CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick conforming to IS:8183 / PU
Foam of 40 Density - at least 40 mm. The resin bonded rockwool
covered from inside the canopy by perforated sheet with 3/4 mm
holes, sound level not more than 75 dB at a distance of 1 mtr, as per
PVCT norms.DG set should have in built fuel tank capacity of
minimum 8 hrs of continous running capacity on full load .
Erection, commissioning and satisfactory testing as per requirement
with first filling of fuel (minimum up to the 80% of fuel tank
capacity), oil, etc. with guarantee / Warrantee of complete system
for Two years. & with obtaining all necessary certificate from
Electrical Inspector. The Capacity and Ratings of DG sets are as
below. (As per new CPCB4+ Emission norms Engine With - Turbo
Charger, EGR (Exhaust Gas Recirculation), CRS (Common Rail Fuel
System), DOC (Diesel Oxidation Catalyst), SCR (Selective Catalytic
Reduction), Integrated wiring harness connected to ECU .) (D)
Continuous Rating of 25 KVA ,BHP not less than 32 BHP
24 1.00 Nos. Providing & erecting approved make ATS panel suitable for following 40229.31 Rupees Forty Ea.
size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete Thousand Two
of scope as detailed below: 1) Power module: Motorised Changeover Hundred
switch with ATS controller, Auxiliary contactor with NO & NC Twenty Nine
contacts with Automatic Battery Charger, indicating lamps for
Generator ON, Mains ON, Load and suitable control terminals and
power terminals with neutral earthing studs. (A) ATS Panel for 15/20
/ 25 KVA 3 phase DG Set
Net Amount Put toTender Rs.
Note : This Estimate has been prepared as per new SOR which is exclusive of GST hence additional GST will be paid to the agency as per
existing guidlines.
Deputy Executive Engineer Executive Engineer
Electrical (R&B) Sub Division Electrical (R&B) Division
Jamnagar Rajkot
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ANNEXURE-II notice NIVIDA 8e 2025-26.pdf
sch B.pdf
SBD Nivida 8e of 2025-26.docx
DOCX
Contractor_Registration_Paripatra__1_.pdf
EMD_SD GR.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .