Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.10Accepted-AOC VPO GANGANA NEAR RAVIDAS MANDIR 131302 | GANGANA | SONIPAT | HARYANA | 131302 | L1 | Accepted-AOC SINGLE BIDDER PARTICIPATED AND FOUND RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹47,680
Closing Date
23 Jun 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
E E P-1 SONEPAT
E E P-1 SONEPAT
Construction of 5 Nos. Rain Water Harvesting System in Govt. College Pipli AND Tehsil Building at Kharkhoda in Sonepat Distt. (Re-Invited)
2021_HRY_175985_1
PWD/RWH
Open Tender
Civil Works
Works
60 days
SONEPAT CIRCLE
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹47,680
Yes
6 Aug 2021
16 Jun 2021
23 Jun 2021
16 Jun 2021
23 Jun 2021
16 Jun 2021
120 days
Amount
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia (HSR 4.16.1.2)
Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (HSR 33.8.2) 150 mm nominal size dia
150mm sloted pipe for charging well
Constructing brick masonry inspecion Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick cement concrete topping, 50mm thick with 455mm x 455mm / 455mm x 610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specifction painted with 3 cats of black bitumastic superor paint complete as per standard design (HSR 21.84.2) b) 450 mm x 600 mm
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (HSR 4.14.1)
1:4:8 (1 Cement : 4 carse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.6)
1 : 1½:3 ( 1 cement : 1 ½ coarse sand (zoneIll) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.2.1)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.20.1)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (HSR 11.5.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.34.3) Cold twisted bars
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (HSR 9.59.3).150mm
Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge.. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening. (HSR 21.93.1)
Providing & fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge(HSR 21.28)
Providing and placing in horizontal layers filtering media screened washed and cleaned as described below - Top Layer: Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source (HSR 20.52.1)
Second layer :- Coursed sand screened, cleaned and washed and graded from 3 mm to 6 mm (from Ghaggar or approved equivalent quarry)
Third layer: - Bajri (course) screned and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry)
(d) Fourth layer: - Bajri (course) screened and washed graded fom 20 mm to 25 mm (from Ghaggar or apprved equivalent quarry)
(e) Bottom layer:- Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry)
Boring with 100 mm diameter casing pipe for hand pump / tube well, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested. Beyond 12 m and up to 18 m depth (HSR 33.1.3)Note:- In case of any difference in the unit & nomenclature of any of HSR items depicted in this DNIT and that given in HSR, the unit and nomenclature given in HSR shall be applicable. (ii) In case of any difference in the unit of any non-schedule items depicted in this DNIT and the conventional unit of that N.S. item as per prectice in this department, the conventional unit as per practice shall be applicable.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .