Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.8 LAccepted-AOC | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹47.8 L+₹1.3 L (2.86%)Rejected-AOC 777 778 SASTRI NAGAR SARAT SARANI SUBHASPALLY BURNPUR BARDHAMAN WEST BENGAL 713325 UDYAM WB 23 0020628 | PASCHIM BARDHAMAN | WEST BENGAL | 713325 | 2 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 3 | 3₹47.9 L+₹1.4 L (3.00%)Rejected-AOC | 3 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 4 | 4₹48.0 L+₹1.5 L (3.17%)Rejected-AOC | 4 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 5 | 5₹48.1 L+₹1.6 L (3.42%)Rejected-AOC DS COLONY BINNAGURI TG ROAD OPP MILAN SANGH CLUB POST BINNAGURI DISTT JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | 5 | Rejected-AOC OTHER THEN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Tirupati Construction L1 | S.N. GHOSH AND CO. L4 | BBKundu L7 | M/s Sohini Construction L6 | M/S RELIABLE CONSTRUCTION CO. L2 | M/S RATNESH KUMAR SINGH L5 | ANUP ENGINEERING WORKS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n exc 1.5 mtr wide and n.exc 1.5 mtr deep for pipe line in any type of soil, getting out and leveling of bottom surface to required level all as specified. | 343.41 | Cum | 400 ₹1,37,364 Lowest | 410 ₹1,40,798.1 | 419 ₹1,43,888.79 | 425 ₹1,45,949.25 | 405 ₹1,39,081.05 | 400 ₹1,37,364 Lowest | 430 ₹1,47,666.3 |
| 2.00 | Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified | 292.77 | Cum | 200 ₹58,554 Lowest | 210 ₹61,481.7 | 349 ₹1,02,176.73 | 325 ₹95,150.25 | 220 ₹64,409.4 | 210 ₹61,481.7 | 222 ₹64,994.94 |
| 3.00 | Removing excavated material from site to a distance not exc 50 mtr away and depositing where as directed not exc 1.5 mtr from the starting point all as specified | 50.64 | Cum | 300 ₹15,192 Lowest | 300 ₹15,192 Lowest | 309 ₹15,647.76 | 325 ₹16,458 | 320 ₹16,204.8 | 320 ₹16,204.8 | 325 ₹16,458 |
| 4.00 | Taking up old cast iron water mains 200mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified | 214.5 | RM | 165 ₹35,392.5 | 160 ₹34,320 Lowest | 209 ₹44,830.5 | 220 ₹47,190 | 170 ₹36,465 | 165 ₹35,392.5 | 180 ₹38,610 |
| 5.00 | Taking up old cast iron water mains 150mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified | 539 | RM | 120 ₹64,680 Lowest | 130 ₹70,070 | 149 ₹80,311 | 155 ₹83,545 | 135 ₹72,765 | 130 ₹70,070 | 122 ₹65,758 |
| 6.00 | Taking up old cast iron water mains 100mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified | 187 | RM | 55 ₹10,285 Lowest | 58 ₹10,846 | 79 ₹14,773 | 75 ₹14,025 | 56 ₹10,472 | 59 ₹11,033 | 62 ₹11,594 |
| 7.00 | Taking up old cast iron water mains 80mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified | 77 | RM | 50 ₹3,850 Lowest | 53 ₹4,081 | 79 ₹6,083 | 80 ₹6,160 | 56 ₹4,312 | 57 ₹4,389 | 58 ₹4,466 |
| 8.00 | S&F for Ductile Iron pipes 200mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified | 192.5 | RM | 2,850 ₹5,48,625 Lowest | 2,950 ₹5,67,875 | 2,999 ₹5,77,307.5 | 3,200 ₹6,16,000 | 2,900 ₹5,58,250 | 2,980 ₹5,73,650 | 2,965 ₹5,70,762.5 |
| 9.00 | S&F for Ductile Iron pipes 150mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified | 495 | RM | 2,450 ₹12,12,750 Lowest | 2,490 ₹12,32,550 | 2,709 ₹13,40,955 | 2,600 ₹12,87,000 | 2,475 ₹12,25,125 | 2,500 ₹12,37,500 | 2,498 ₹12,36,510 |
| 10.00 | S&F for Ductile Iron pipes 100mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified | 165 | RM | 1,750 ₹2,88,750 Lowest | 1,775 ₹2,92,875 | 2,509 ₹4,13,985 | 2,400 ₹3,96,000 | 1,785 ₹2,94,525 | 1,810 ₹2,98,650 | 1,750 ₹2,88,750 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Jul 2025, 6:00 pmClosed
GE (S) Binnaguri
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
As per tender docus
2025_MES_714198_1
8765/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (S) Binnaguri
Class D and Category a (ii)
7 documents required · 7 mandatory
₹500
GE (S) Binnaguri
₹90,000
Yes
26 Aug 2025
14 Jun 2025
26 Jul 2025
14 Jun 2025
19 Jul 2025
30 Jun 2025
14 Jun 2025 - 30 Jun 2025
Amount
Excavation in trenches n exc 1.5 mtr wide and n.exc 1.5 mtr deep for pipe line in any type of soil, getting out and leveling of bottom surface to required level all as specified.
Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified
Removing excavated material from site to a distance not exc 50 mtr away and depositing where as directed not exc 1.5 mtr from the starting point all as specified
Taking up old cast iron water mains 200mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified
Taking up old cast iron water mains 150mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified
Taking up old cast iron water mains 100mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified
Taking up old cast iron water mains 80mm bore (dia) with all fittings with spigot and socket ends and lead joints inclunding burning out joints etc complete all as specified
S&F for Ductile Iron pipes 200mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified
S&F for Ductile Iron pipes 150mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified
S&F for Ductile Iron pipes 100mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified
S&F for Ductile Iron pipes 80mm bore with spigot and socket ends ,Rubber gas kit as per IS- 8329,internal lining with cement mortor class K-7 in any length laid in trenches including all necessary fittings such as bend, reducer,tee socket etc all as specified
Refixing old cast iron/ ductile iron water mains obtained from dismantling 200mm bore (dia) with all fittings with spigot and socket ends complete all as specified
Refixing old cast iron/ ductile iron water mains obtained from dismantling 150mm bore (dia) with all fittings with spigot and socket ends complete all as specified
Refixing old cast iron/ ductile iron water mains obtained from dismantling 100mm bore (dia) with all fittings with spigot and socket ends complete all as specified
Refixing old cast iron/ ductile iron water mains obtained from dismantling 80mm bore (dia) with all fittings with spigot and socket ends complete all as specified
S & F CI fittings such as bend, reducer , socket, Tee etc of various size complete all as specified
Supply and fix CI sluice valve Cast iron 200mm bore PN-1.6 flanged end conforming to IS -14846 with CI wheel, brass spindle, chuck nuts, rubber gasket, bolts (full threded), nuts & washers including joints complete all as specified and directed including dismantling and taking down of old unserviceable CI Sluice valve from existing position complete all as specified
Supply and fix CI sluice valve Cast iron 150mm bore PN-1.6 flanged end conforming to IS -14846 with CI wheel, brass spindle, chuck nuts, rubber gasket, bolts (full threded), nuts & washers including joints complete all as specified and directed including dismantling and taking down of old unserviceable CI Sluice valve from existing position complete all as specified
Supply and fix CI sluice valve Cast iron 100mm bore PN-1.6 flanged end conforming to IS -14846 with CI wheel, brass spindle, chuck nuts, rubber gasket, bolts (full threded), nuts & washers including joints complete all as specified and directed including dismantling and taking down of old unserviceable CI Sluice valve from existing position complete all as specified
Supply and fix lever operated Wafer butterfly valve IS-13095 ,PN-1.6,150mm bore single disc type with complete accessories such as rubber gasket, bolts (full threded), nuts & washers including joints complete all as specified and directed including dismantling and taking down of old unserviceable butterfly valve from existing position complete all as specified
Supply and fix Brass Spindle for sluice valve of size 250 mm complete including dismantling and taking down of old unserviceable one all as specified
Supply and fix Brass Spindle for sluice valve of size 200 mm complete including dismantling and taking down of old unserviceable one all as specified
Supply and fix Brass Spindle for sluice valve of size 150 mm complete including dismantling and taking down of old unserviceable one all as specified
Supply and fix Brass Spindle for sluice valve of size 100 mm complete including dismantling and taking down of old unserviceable one all as specified
Dismantling existing unserviceable valve pits and construction of new brick masonry valve pits of size 1200x1200x1200mm (internal dimension) with brick work in cement mortar (1:4) 40mmx40mm x6 mm angle iron frame ,MS handle 300mm long, bent to shape and riveted to MS sheet including excavation and earth work, concrete work 3 mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete all as specified
All as per item No 25 above but of size 900x900x900mm (internal dimension)
M&L for providing cement concrete type D2(1:4:8) using 40 mm graded stone aggregate in foundation of pole for supporting of pipe line all as specified
M&L burning out Lead Joint in Cast Iron Pipes 80mm bore (dia) in Position including recovering old Lead, complete all as specified
M&L burning out Lead Joint in Cast Iron Pipes 100mm bore (dia) in Position including recovering old Lead, complete all as specified
M&L burning out Lead Joint in Cast Iron Pipes 150mm bore (dia) in Position including recovering old Lead, complete all as specified
M&L burning out Lead Joint in Cast Iron Pipes 200mm bore (dia) in Position including recovering old Lead, complete all as specified
Supply and pour lead joints for pipes and fittings (spigot and socket ends) 80 mm bore (dia) and testing complete all as specified
Supply and pour lead joints for pipes and fittings (spigot and socket ends) 100 mm bore (dia) and testing complete all as specified
Supply and pour lead joints for pipes and fittings (spigot and socket ends) 150 mm bore (dia) and testing complete all as specified
Supply and pour lead joints for pipes and fittings (spigot and socket ends) 200 mm bore (dia) and testing complete all as specified
Supply and fix valve ( NRV ) reflux flanged end of size 150 mm dia incl making necessary joints dismantalling and taking out old u/s NRV complete all as specified
-----Blank-----
M&L for repairing/ servicing of leakage sluice value of size 80/100/150 mm dia by opening of gland cup, stuffing box, MS nut bolts for replacement of suitable size MS nut bolts, rubber gasket and gasket rope for arresting leakage in value chamber raising mains or any position all as specified
All as per Item No 38 herein above but for 200/250 mm bore sluice value complete all as specified
Attending water leakage and repairing of leakaged/ broken CI/DI pipe line of size 80/100/150 mm dia by excavating the leakaged portion , dewatering the accumulated water , find out the leakage and repair/ replace the damaged portion of pipe, cocking the lead joint using lead wool or pouring lead joint testing the repaired portion by opening of water for entire satisfaction and returning filling and removal of surplus soil as specified Notes:- (i) The cost for arrangement of suitable pump sets for dewatering at the time of attending bereak down deemed to be include in quoted rate. (ii) Lead joints CI/DI/MS pipes, CI fittings /specials, Excavation and earth work will be measured and paid separately under relevent items of BOQ
All as per Item No 40 herein above but for 200/250 mm bore CI/DI pipe all as specified
Surface dressing/excavation in soft /loose soil not exeeding 15 cm deep, across the pipe lines etc, and including site clearence, cutting and cleaning of branches / bushes / plants / grass obstructing the pipe lines / valves / chambers / sumps /pump houses/ OHTs on either sides and water supply Installation area including disposal of materials up to a distance not exceeding 50 m complete all as specified
M/S RELIABLE CONSTRUCTION CO. (BID ID -3354556)
ANUP ENGINEERING WORKS (BID ID -3350044)
S.N. GHOSH AND CO. (BID ID -3350183)
M/S RATNESH KUMAR SINGH (BID ID -3362885)
M/s Sohini Construction (BID ID -3363608)
BBKundu (BID ID -3362785)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .