Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 504 MANGAL MURTI HEIGHTS RANI BAGAN HARMU ROAD RANCHI | RANCHI | JHARKHAND | 829205 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical A 104 SYMPHONY PLOT NO 9 NEAR SAHJANAND CHOWK HARMU HOUSING COLONY HARMU RANCHI JHARKHAND | Rejected-Technical NON RESPONSIVE |
| 4 | Rejected-Technical AMIKA MANSILLPARK SASCET DARDEADO JOINED COLLEGE DOORDA RANCHI HOB | Rejected-Technical NON RESPONSIVE |
| 5 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹20.1 L
Closing Date
27 Aug 2022, 5:00 pmClosed
NODAL OFFICER
e-Procurement Cell, Building Construction Department, Jharkhand, Ranchi.
Proposed Construction of 12 Court Building at Lohardaga.
2022_BCD_60753_1
BCD/ Lohardaga/06/2022-23
Open Tender
Civil Works - Buildings
450 days
Lohardaga
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE BCD Building Division Lohardaga
₹20.1 L
28 Sept 2022
13 Aug 2022
30 Aug 2022
13 Aug 2022
27 Aug 2022
13 Aug 2022
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement , including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works above plinth level upto floor V level
Providing Tor steel reinforcement of 8mm dia rods as approved
Providing Tor steel reinforcement of 10 mm dia rods as approved
Providing Tor steel reinforcement of 12 & 32 mm dia rods as approved
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Stairs, (excluding landings) except spiral-staircases
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
Providing 25mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100A work with fly ash lime brick (FLAG) confirming to IS 12894- 1990 (9" X 4.5" X 3") in C.M (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112 mm thick reinforced designation 100A brick work with fly ash lime brick(FLAG) confirming to IS 12894-1990(9''X4.5''X3'') in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening, carriage of materials scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Extra of plaster work over exterior surface for each consecutive floor above above first floor including cost of scaffolding etc. All complete as per direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
40 mm thick
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Medium shade pigment using 50% white cement 50% Grey cement
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete
Size of Tile 1000x1000 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 1000x1000 mm
Providing and laying Double charge virtified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622/ ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grounting the joints with white cement and matching pigments etc. complete Size of Tile 600x600mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Udaipur green marble
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
Granite of any colour and shade
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Marble work
Granite work
Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile C
Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting & fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting & fixing 35mm thick solid core type non-decorative double leaf flush shutter in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings /wooden frames with rawl plugs screws etc
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer?in-Charge
Providing and fixing to existing door frames.
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter)
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:
With common burnt clay F.P.S. (non modular) brick tiles of class designation 10
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps :- (a) Surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jel including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand: Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder - Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4N/mm2 (According to FIP 5.15) Elongation at Break ~35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)
(d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamfered vrith 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc. Warrenty for five years.
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.-There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+
Providing and filling of 6mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST).Brand:-Sika Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent.
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.
2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Bend 87.5° 110 mm bend
Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complet
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer?in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black), comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tilesh 50 mm resin bonded glass wool backing.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Providing designation 75A one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carraige of water with all leads and lifts as per building specification and direction of E/I.
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m)
Including Royalty etc@ Rs. 27.48 per cum, cost of watering, rolling & compaction.
Providing designation 75A one brick on edge soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
Using Concrete Mixer
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing two coats of snowcem of approved shade and make new old surface including washing cleaning, and preparing the walls, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc. And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil.
All kind of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and laying Non pressure NP2 class (light duty)RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.
150 mm dia RCC pipe
Carriage of material
Earth Disposal
Brick
Chips
Metal
Flyash Brick
Wiring for Light point/ Fan point/ Exhaust Fan point/ Call Bell point with .1.5 sq.mm FR PVC insulated Copper Conductor Cable in surface/ recessed PVC Conduit with modular type switch, modular plate, suitable size PVC/MS. box etc. as required.(Group-A)
Wiring for Twin control light point 1.5 SQ.MM FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modulaor switch, modular plate,suitable size G.I. box etc as required.
S/F Suitable size G.I. box with moudlar plate and cover in front on surface or inrecess including Providing and fixing. 3 pin 5/6 Amp modular socket outlet and 5/6 Amp modular switch connection painting etc. as reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
S/F Suitable size G.I. box with moudlar plate and cover in front on surface or inrecess including P.F. 6 pin 15/16 Amp modular socket outlet and 15/16 Amp modular switch connection painting etc. as reqd.
Wiring for light/power plug point with 2 x 4 Sq.mm FR PVC insulated copper conductor single core Cable in recessed / surface PVC conduit along with 1 no. 4 sq. mm copper conductor wire for loop earthing as required.
Wiring for sub-main wiring with the following sizes PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.
2 x 1.5 + 1 x 1.5sq.mm
2 x 2.5 + 1 x 2.5sq.mm
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 x 6 Sq mm+2 x 6 sq mm earth wire
4x10 sqmm +2 x 6 sqmm earth wire
4x16sqmm +2 x 6 sqmm earth wire
Telephone wiring in existing conduit - Supplying and drawing following pair, 0.5 sq.mm FR PVC copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required.
TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required.
S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required
Telephone socket with shtter outlet
TV antenna socket outlet
S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75mm x 75mm x 50mm deep/(4" x 4")
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required
S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.
25 mm dia
32 mm dia
S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way ( 4 + 12 ), double door, horizontal type
6 way ( 4 + 18 ), double door, horizontal type
8 way ( 4 + 24 ), double door, horizontal type
Supplying & fixing of following rating and poles, B&C series miniature circuit breaker in the existing MCB DB Complete with connection testing and commissioning etc. as required.
6/32 A SP MCB 'B' series
S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.
40 amps, Tripole pole and neutral
50/63 amps, Tripole pole and neutral
S/F TPN RCCB - Supplying and fixing following rating, TP&N, (three phase and netural) 415 volts, residential current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required
SIT of following rating surface mounted LD Tube light fiting suitable for 230V 50HZ, single phase supplay etc comlete as required.
20/22 Tube Light
SIT of following rating Recessed /surface mounted LED Round/ Square shape downrigger luminaire with presser die cost housing light fitting suitable for 230V 50HZ, single phase supply etc complete as required. For single phase supply voltage luminaire shall be conform to IS 10322 part 5 section-2 or IEC 62762 With all necessary accessories as required.
6/7 watt LED Round downlighter
12 watt LED Round downlighter
18/20 watt LED Round downlighter
2'X2' Panel Light
Supply and installation , Testing and commissioning of following size 3 blades conforming to IS : 374 ;2019 including wiring the down rod of stsansrad lenth (up to 30cm) with 1.5sq mm FR PVC insulated copper wire suitable for 230V 50HZ, single phase supplay etc comlete as required
1200 mm (48') BLDC star rating 32 W Ceilling Fan
Supplying & fixing of stepped type electronic fan regulator the exisiting modular palte switch box including connections but excluding modular palte etc as required.
Supply of Metal Exhaust Fan 12"(300mm): Supply of 12"(3000mm), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required
Supply of wall Fan 16"(400mm): Supply of 16"(4000mm), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required
Installation , Testing and commissioning of pre wire flouresent fitting/compact flouresent fitting of all types ,complete with all accessories and tube rtc. Directly/wall including conection with 1.5 sqmm FR PVC insulated.copper conductore single core cable and earthing atc as required.
Installation , Testing and commissioning of Exhaust Fan UP to 450MM Sweep in the exhausting opening including making the hole to suit the size of the above fan making good the damage , conection Testing and commissioning atc as required.
Supply off PVC/ XLPE insulatede PVC sheahted heavy duty , armourd electrical cable with alluminuam conductor for working volatge up to and including 1100 volts conform to IS :1554 ,-Part-1
3.5C x 300 Sq.mm cable
3.5C x 150 Sq.mm cable
3.5 C x 25 Sq.mm cable
4C x 16 Sq.mm cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C x 300 Sq.mm cable
3.5C x 150 Sq.mm cable
3.5C x 25 Sq.mm cable
4C x 16 Sq.mm cable
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trecnch aetc. as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 95 sq.mm. but not exceeding 185 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
100 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.I. earth plate 600mm 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt)
Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt)
Providing and fixing 25mm x 5mm copper strip in 40mm dia G.I. pipe from earth electrode, as required
Providing and fixing 25mm x 5mm G.I. strip
P/F 25mmx5mm copper earth strip on surface or inrecess for connections etc ,as required .
P/F 25mmx5mm GI earth strip on surface or inrecess for connections etc ,as required .
SITC online ups three phase inputand three phase output system of input voltage range 360V/380V/400V/485V AC Frequency Range 40HZ to 60HZ +_ 10%, Output voltage range 415v+_10% Frequency Range 50HZ +_1% power facator 0.0.8/3.1 harmpnic distrorson -<2% THD (linear load ) 50% thd (Non linear load)
SITC of MS Battey rack suitable for 15 to 20 Battery Instalaion.
SITC 12V 120AH Sealed mantenece free (SMF) batteries with 24 month replacement guaranty (Suitable for battery bank of 32 nos.)
Supply, fitting, errection and commissioning of 500 KVA D.G. Set, 415 Volts, 3 Ph. Silent Diesel Generator Set confirming to IS:10001/10002 AC supply complete with engine (1500 RPM) and alternator DG Set controller confiring to IS:13364 with accessories including residential type silencer and fuel service tank 990 litres capacity, battery, nattery leads, battery charger with all accessories, including MCCB of suitable rating & standard set of tools and anti-vibration mounting pads, etc. The power command controller compactable with BMS, PC & PLC compelte as required, remote mointoring and data logging with digital voltage regulator through inbuilt AVR, digital governing including protection complete as required. Providing & installing the complete control cables between DG Set & Main LT Panel to make system autiomatic complete as required. Rate shall be inclusive of all items required for D.G. Sets exhaust system including M.S. pipes, insulation, M.S. structure & accessories etc. and shall be compiled to ECBC-2007 norms, along with the following accessories:- (Make:-Kirloskar (GREEN) / Sterling & Wilson / Jakson)/SUPERNOVA
Supply of acoustic enclosure for 40 0KVA CPCB approved Acoustic enclosure with 80 mm MS base plate, 2 mm CRCA sheet, 50 mm thick foam / 100 mm Rock Wool Insulation, 14 surface tank treatment, dully powder coated and painted with Briliant Blue colour with integrate Fuel Tank, services door, louvers (Fresh Air / Radiator), 1020 dia residential type Silencer, complete with following accessories :-
a) Fuel Tank.
b) Batteries, battery leads and battery charger.
c) Residential Silencers.
d) First fill of lube oil.
e) A.M.F. Panel.
f) AVM Pads.
In above supply item following work are also included :- i) Installation, fitting, fixing, testing and commissioning of the same. ii)Civil part for commissioning of D.G. Set. iii) Installation of Exhaust system for D.G. Set shall be as per Central & State Pollution Board Norms along with iron structure i.e. 5 mtr. above the height of nearest building.If this will be in the scope of the contractor then charges shall be extra and that will be the actual. iv) Test run for D.G. Sets without load and with load (part wise ).
Supply of Control Breaker AMF Panel for having all type of meters (Voltmeter, Ammeter, KW/m, Hz/m) with suitable arrangement for 1 Runs 300 Sq mm 43.5 Core Al. Ar. Cable etc as required. Note:- Technical specification of above 380 KVA Silent D.G. Set shall be provided at the time of work order.
Ten Loop Panel
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (Heat Detector )
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (Smoke Detector )
Supplying, installation, testing & commissioning of addressable fire control module complete as required
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Wiring for sub-main wiring with the following sizes PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.
2 X 1.5 sq. mm
4 X 1.5 sq. mm
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
Speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. ‘p’ trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S.equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C.telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.
580 mm. long
With low level PVC cistem
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipewith brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S.make with hinges or screws etc. painting pipe and cistern etc. with 2coats of approved paint over a coat of red oxide priming, all completeas per specification and direction of E/I.
E.W.C. with 'P' trap
(b) 12.5 lit. low level PVC. Cistem
Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of ‘Hindustan "Parry" or any other approved I.S.S make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I.or R.S. brackets, standard size G.I. flush pipe with fitting clamps,15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.
Flat back or standing corner (600mmx350mm)
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm longwith brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Providing and fixing male ended 15mm dia brass bib cock of approved quality (wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I.
Providing and fixing lead connection pipe with heavy quality brass coupling 2 nos. at both ends etc. all complete as per specification and direction of engineer-in-charge.
15 mm dia and 45 cm long.
Providing and fixing N.P./C.P. brass/ P.V.C. porcelain shower rose of 15 mm inlet etc. all complete as per specification and direction of Engineer-in-charge.
125 mm dia C.P. shower
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.
600mm x 450mm size
C.P. brass towel rail 20mm x 600mm bracket container.
C.P. brass dish container medium quality with screw and hinges etc.
C.P. brass liquid soap container.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink without drain board
610x460 mm bowl depth 200 mm
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
40 mm dia
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15 mm nominal bore
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm and down gauge).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler
Single tee with door
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing PTMT grating of approved quality and colour.
Circular type
100 mm nominal dia
Providing and fixing gun metal full way valve of approved quality, all completeas per specification and direction of E/I.
15 mm dia weight not less than 300 gms.
20 mm dia weight not less than 400 gms.
25 mm dia weight not less than 500 gms
32 mm dia weight not less than 700 gms.
40 mm dia weight not less than 1.0 kg.
50 mm dia weight not less than 1.5 kg.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Pipe running at terrace level
25 mm nominal dia Pipes
32 mm nominal dia Pipes
40 mm nominal dia Pipes
50 mm nominal dia Pipes
65 mm nominal inner dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on wall
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
65 mm dia
50 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to 150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 lpm at 70 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 70m Head
FIRE PUMPS - DIESEL
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
2280 lpm at 70 m Head
Fabricating, supplying, testing and commissioning of electrical control panel of cubicle construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentallised and hinged lockable doors, dust and vermin proof, powder coated approved shade after 7 tank treatment process, cable alley interconnection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects, suitable for operation on 415V, 3 phase 50 Hz., AC supplywith enclosure protection class IP-42as required.
COMMON PANEL IN FIRE PUMP HOUSE.
INCOMER
250A, 50kA 4 Pole MCCB, Ics=100% Icu rating
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 500A
OUTGOING.
Main fire pump and Sprinkler pump
Jockey pump
Diesel Engine Control
Control for Diesel Engine comprising:-
Indication lamp for High / Low Lub. Oil pressure, High Water Temp. and Engine ON indication.
All standard relays and acessories for automatic operation of diesel engine.
Diesel Engine Control
Control for Diesel Engine comprising:-
Indication lamp for High / Low Lub. Oil pressure, High Water Temp. and Engine ON indication.
All standard relays and accessories for automatic operation of diesel engine
SYSTEM CONTROLLER
Designing, Supply, Installation, Testing and Commissioning of system controller to control operation of Main Electric Fire Pump, Diesel Pump in sequence as per specification consisting of relays, timets, sensors, annunciation window for fault indication, complete as per specification.
Note - All cabling, earthing, GI strip and cable tray including all electrical related accessories included in electrical tender.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
RCC GSR AND SUMP
Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion. to inside face of the container,including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye-pass arrangement consisting of C.I./ M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications.
Anti –termite treatment shall be given for under ground portion of the structure.
Notes
The design shall be in accordance with various relevant I.S. specification (I.S.456/2000,I.S.875-1987,I.S.3370-1965 or revised.)
Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S.1139 shall be used.Grade- II M.S. bars shall not be used.
Entire structure shall be in M-300 only.
The scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.
The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.
The Job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineer-in-charge. If up lifts considered in design, then these rates shall be increased by 7.5%.
G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.
For pipe diameters upto 300mm only CIpipes and CI specials shall be used. For pipe diameters above 300mm, M.S. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside.
Cost of pump house is not included in these rates.
Above rates are applicable for Seismic Zones 2, 3 and 4.
75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.
10% shall be added for sump if over head pump house is proposed.
Note: Conditions from Sr.No.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C .GSRs and sumps.
Rates for RCC GSRs and Sumps
Cost of 1,50,000 Capacity
G.I. earth plate electrode - Earthing with G.I. earth plate 600mm 600mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (with charcoal or coke and salt)
Providing & fixing 25mmx 5mm G.I. earth strip in ground - Providing and fixing 25mm x 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
S/L 25mmx 5mm G.I. earth strip in ground - Supplying and laying 25mm x 5mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 stes of G.I. nut bolt & spring washer spaced at 50mm)
P/F 6 SWG G.I. loop earthing wire in surface/recess - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
MV cable laying upto 35 sq.mm. in ground - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
MV cable laying upto 95 sq.mm. in ground - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals.
3.5 Core 120 sq. mm. Armoured Aluminium cable.
3.5 Core 35 sq. mm. Armoured Aluminium cable.
3.5 Core 16 sq. mm. Armoured Aluminium cable.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Providing and fixing of standard short size GM branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked & TAC approved.
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
4 way - 150 mm dia M.S. Pipe
2 way - 100 mm dia M.S. Pipe
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately)
50 mm dia.
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
150 mm dia.pipe
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
150 mm dia.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
100 mm dia
150 mm dia
200 mm dia
300mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
200 nominal bore (class C)
150 nominal bore (class C)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
200 mm nominal bore (class C)
150 mm nominal bore (class C)
100 mm nominal bore (class C)
80 mm nominal bore (class C)
65 mm nominal bore (class C)
50 mm nominal bore (class C)
40 mm nominal bore (class C)
32 mm nominal bore (class C)
25 mm nominal bore (class C)
Providing, fixing, testing & commissioning of 15mm dia uartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Concealed sprinkler
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Jungle clearance in borrow area, building premises, flanks and slope on the road, canals and embankment by removing the grass and jungle bushes from the top including weeding out shrubs small trees upto 150 mm dia. and their removal all complete job as per direction of E/I.
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, as per directions of Engineer in Incharge: All kinds of soil
Supply , stacking & filling of good earth at site including cost of royalty & carriage upto 5 Km ( Earth measured in stacks will be reduced by 20% for payment ) .
Supplying and stacking at site dump manure from approved source, including carriage up to 5 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
Rough dressing the trenched ground including breaking clods.
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation
Fine dressing of the ground.
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified ordirected by the Officer-in-charge
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 90cm dia, &90cm deep
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, edge, flower beds, foliages, creepers etc. including hoeing,weeding, pruning, replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide will be provided by the Department & lawn mover and brush cutter with fuel and other T & P material/articles shall be provided by the contractor.) and as per direction of officer in charge. Open spaces(1Mali for 3.00Acre).
Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termiteinfection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge.
Providing and Displaying Ficus Long Island topiary well developed with fresh & healthy 5 to 6 ball specific size and shape 120 to 150 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus Retusa topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Phoenix roebelenii palm well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot as per direction of the officer-in-charge..
Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Topiary of Ficus Nuda well developed with fresh & healthy foliage from Top to Bottom with single piller 75 to 90 cm spread, 195 to 210 cm ht. in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm ht., in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Travelers palm well developed with fresh & healthy leaves foliage 210 to 240 cm ht specimen in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Grevillea robusta (Silver Oak) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Jacaranda mimosifolia of height 150-165 cm. In big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Millingtonia hortensis of height 150-165 cm. In big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Peltophorum species of height 150-165 cm. In big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Schleichera trijuga (Kusum) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
Providing and stacking of Tabebuia sp. of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Alternanthera red/green species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
Providing and stacking of Iresine herbstii, of height 20-25 cm. full of branches well developed in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ophiopogon jaburan ( variegated ),full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge..
Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.
Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge.
Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.
Providing and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy ,in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3- 4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Clerodendrum splendens of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Ipomoea purpurea (Morning glory) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Jasmine humile (Yellow) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Tecoma grandiflora of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge..
Providing and stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
2.0 Tr 5 Star Split AC ( Inverter Type ) IS 1391 Part 1
Copper Tube of size 5/8" for split AC unit 1/1.5/2/3 tr capacity including nitride rubber insulation
5 KVA wall mounted automatic voltage stablizer from range 140 V to 280 V
Drain Pipe for AC
Outdoor Stand for 2.0 Tr Split AC
FR PVC insulated 3 Core 4 sq.mm copper wire
NON SCHEDULE ITEMS Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated MDB Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated)As per Specification.
INCOMER-1
1 Nos.630 Amps TPN MCCB With thermal magenetic release for O/C,& S/C Protection.
METERING & INDICATION
1 set of phase indicating lamps
1 Nos. Load Analyser cum digital Multifunction Meter with 3 nos. 600/5A, CL-1 CTs, as required.
1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps
INCOMER FROM 380 KVA DG Set (1 nos.)
Each Incomer from DG AMF panel shall be provided with the following:
1 Nos 630Amps TPN MCCB With thermal magenetic release for O/C,& S/C Protection.
IDMTL Protection for S/C, O/C & E/f releases.
Master trip relay
Reverse power Protection.
The MCCB shall be complete with 3nos.600 A/5A, 15VA, 5P10 CTs for protection.
METERING & INDICATION
1 sets of phase indicating lamps
1 sets of Voltmeter (0-500V) with VSS each with 3 nos. 6A SP MCBs each
1 Nos. digital Multifunction Meter with 3 nos. 600/5A, CL-1 CTs, as required
1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps
BUS BAR:-
1 Sets of 800A, TPN Aluminum bus bars with colour coded sleeves.
OUTGOINGS
5 Nos. 250 Amps TPN MCCB With thermal magenetic release for O/C,& S/C Protection.
8 Nos. 63 Amps FP MCB
6 Nos. 40 Amps FP MCB
Supply of MDB as Described above
Fabrication, supply, installation, testing and commissionings of cubicle type floor/ wall mounted Main Distribution Board panel made out of 16mm thick CRCA sheet including connection, inter-connection alongwith 4 stsrip aluminium bus bar as per CP WD specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel mounting switchgears etc. as required. As per spcification.
Incoming
1 Nos. 250Amps TPN MCCB With thermal magenetic release for O/C,& S/C Protection.
Protection Istrument
One (1) Set of Phase Indication & ON/OFF Lamp with 2A MCB.
Busbar
300 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.
OUTGOING
i) 2 Nos.100 Amps TPN MCB .
ii) 2 Nos.63 Amps TPN MCB .
iii) 6 Nos. 40 Amps TPN MCB .
Ten (10) Set of LED ON Indication Lamp with 2A Fuse.
Fabrication, supply, installation, testing and commissionings of cubicle type floor/ wall mounted Main Distribution Board panel made out of 16mm thick CRCA sheet including connection, inter-connection alongwith 4 stsrip aluminium bus bar as per CP WD specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel mounting switchgears etc. as required. As per spcification.
Incoming
1 Nos. 63 0Amps TPN MCB
Protection Istrument
One (1) Set of Phase Indication & ON/OFF Lamp with 2A MCB.
Busbar
100 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.
OUTGOING
i) 4 Nos.40 Amps TPN MCB .
Four (4) Set of LED ON Indication Lamp with 2A Fuse.
15 Passenger, Unit 1 PRODUCT : GeN2-Nova MRL DETAILS : GeN2-Nova_MRL-1MPS CAPACITY (kgs) : 1020 Kg, 15 persons. SPEED (mps) : 1 mps RISE (m) : 14.4 m STOPS : 5 Stops With (all opening on the same side) CONTROLLER TYPE : ACD5-MRL DRIVE : VF Regenerative (Closed Loop) POWER SUPPLY : 400/415 Volts (3 Phase AC) OPERATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located in shaft on top of guide rails) TRACTION MEDIA : Flat Coated Steel Belt CAR FINISH : • Rear Mid Panel = Stainless Steel #4(Hairline) • Rear Corner Panels = Stainless Steel #4(Hairline) • Side Mid Panels = Stainless Steel #4(Hairline) • Side Corner Panels = Stainless Steel #4(Hairline) • Front Panels = Stainless Steel #4(Hairline) FALSE CEILING TYPE : CD-41 FLASE CEILING FINISH : Stainless Steel #4(Hairline) VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel Mirror Finish Handrails on rear car panels FLOORING : Vinyl Tiles CAR DOOR FINISH : Stainless Steel #4(Hairline) LANDING DOORS FINISH : Stainless Steel #4(Hairline) FIRE RATED DOORS : Fire rating-60mins PIT DEPTH : 1350 OVERHEAD 4500 HOISTWAY DIMENSIONS (W x D – mm) : 1750 mm W x 2800 mm D CAR DIMENSIONS (W x D x H - mm) : 1000 mm W x 2400 mm D x 2200 mm H CAR & HOISTWAY DOOR TYPE : Telescopic 2 speed doors DOOR OPENING (W x H - mm) : 900 mm W x 2000 mm H DOOR OPERATOR : DC Door Operator COP : COP for stops <= 12 (950mm) in Stainless Steel #4(Hairline) CAR POSITION INDICATOR : Monochrome LCD-Blue Background & White font Dot matrix (LED) Scrolling Display HALL FIXTURES : O2000 Pan Type Fixture , HALL FIXTURE FACE PLATE : Stainless Steel #4(Hairline) HALL BUTTON ARRANGEMENT : LCD Monochrome type STANDARD FEATURES : Anti-nuisance Car Call Protection Independent Service (for Duplex only) Overload Device Nudging Emergency Car Light Unit Infrared Curtain Door Protection Door Time Protection Emergency Alarm Button Extra Door Time of Lobby & Parking Door Open/Close Button Manual Rescue Operation Belt Inspection Drive Auto Fan Cut Off OPTIONS INCLUDED : Emergency Firemen’s Service, Automatic Rescue operation,
13 Passenger, Unit 2 PRODUCT : GeN2-Nova MRL DETAILS : GeN2-Nova_MRL-1MPS CAPACITY (kgs) : 884 Kg, 13 persons. SPEED (mps) : 1 mps RISE (m) : 14.4 m STOPS : 5 Stops With (all opening on the same side) CONTROLLER TYPE : ACD5-MRL DRIVE : VF Regenerative (Closed Loop) POWER SUPPLY : 400/415 Volts (3 Phase AC) OPERATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located in shaft on top of guide rails) TRACTION MEDIA : Flat Coated Steel Belt CAR FINISH : • Rear Mid Panel = Stainless Steel #4(Hairline) • Rear Corner Panels = Stainless Steel #4(Hairline) • Side Mid Panels = Stainless Steel #4(Hairline) • Side Corner Panels = Stainless Steel #4(Hairline) • Front Panels = Stainless Steel #4(Hairline) FALSE CEILING TYPE : CD-41 FLASE CEILING FINISH : Stainless Steel #4(Hairline) VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel Mirror Finish Handrails on rear car panels FLOORING : Vinyl Tiles CAR DOOR FINISH : Stainless Steel #4(Hairline) LANDING DOORS FINISH : Stainless Steel #4(Hairline) FIRE RATED DOORS : Fire rating-60mins PIT DEPTH : 1350 OVERHEAD 4500 HOISTWAY DIMENSIONS (W x D – mm) : 2300 mm W x 1800 mm D CAR DIMENSIONS (W x D x H - mm) : 1600 mm W x 1350 mm D x 2200 mm H CAR & HOISTWAY DOOR TYPE : Central opening (CO) doors DOOR OPENING (W x H - mm) : 900 mm W x 2000 mm H DOOR OPERATOR : DC Door Operator COP : COP for stops <= 12 (950mm) in Stainless Steel #4(Hairline) CAR POSITION INDICATOR : Monochrome LCD-Blue Background & White font Dot matrix (LED) Scrolling Display HALL FIXTURES : O2000 Pan Type Fixture , HALL FIXTURE FACE PLATE : Stainless Steel #4(Hairline) HALL BUTTON ARRANGEMENT : LCD Monochrome type STANDARD FEATURES : Anti-nuisance Car Call Protection Independent Service (for Duplex only) Overload Device Nudging Emergency Car Light Unit Infrared Curtain Door Protection Door Time Protection Emergency Alarm Button Extra Door Time of Lobby & Parking Door Open/Close Button Manual Rescue Operation Belt Inspection Drive Auto Fan Cut Off OPTIONS INCLUDED : Emergency Firemen’s Service, Automatic Rescue operation,
Supply intalation,Testing & Commising of IR Dome Camera, 2 MP, HD Video Output, with HDTVI TECHNOLOGY and 3- axis adjustment.
Supply intalation,Testing & Commising of IR Bullet camera, 2 MP, HD Video Output with HDTVI Technoly IP 66 Weatherproof and 3-Axis Adjustment.
Supply intalation,Testing & Commising of 16 Channel Turbo HD DVR,up to 1024X786 VGA Output resolution, recording resolution 4CIF/CIF/QCIF, Capacity Up to 2TB for each Interface ,Power supply 230 V AC/50 Hz etc complete as required.also compatible with Mobile Surveillance.
Supply intalation,Testing & Commising 21" Lled/LCD Colour High resolution Monitor for greater than 400 TVL
Supply intalation,Testing & Commising BNC Conector
15 Larsen & Toubro 2 HP Starters Control Panel for Submersible Pump
Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 15683, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.
Capacity 4.5 kg
Providing and fixing (ABC Dry Chemical Powder ) type Fire Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket complete with internal charges.
Capacity 6 Kg.
Providing and fixing mechanical foam type Trolley Mounted Fire Extinguisher of bearing to IS:10568/IS13385/IS13386 with dis
Capacity 45 Lit.
Providing and fixing Carbon Dioxide Type Trolley Mounted Fire Extinguisher of as per IS: 2878 with discharge time of 10 to 20 sec/15 to 36sec/20 to 60sec respectively.
22.5 Kg. CO2 Fire Extinguisher
Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor).
Providing and fixing of TAC approved 1.6mm thick M.S. fire hose cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.
Providing and fixing of Fire Axe
Add 18 % GST
Add 1% Labour Cess
R.S.AGRAWAL INFRATECH PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid