Loading…
Loading…
Tender Value
₹12.7 L
EMD Value
₹31,762
Closing Date
5 Sept 2026, 6:00 pmDue today
AEE
PWD Electrical Sub Division Tvpm
GENERAL-Government Secretariat, Thiruvananthapuram- Running contract for urgent replacement of Air conditioner units for 6 months-Ministers AC-Electrical AC Work
2026_PWD_865857_2
ESDT/ET-94/2026-27
Open Tender
Electrical Works
Item Rate
180 days
PWD Electrical Sub Division Tvpm
please refer tender documents
5 documents required · 5 mandatory
₹2,760
₹31,762
29 Aug 2026
29 Aug 2026
7 Sept 2026
29 Aug 2026
5 Sept 2026
29 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Part-1 Air conditioning | |||||
| 1.001 | OD32316/2026-2027:"
Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete ,Make : Panasonic/Daikin/Mitsubishi/ Carrier/ Bluestar:/Voltas- 1.0TR single phase Inverter split A/C unit" | - | each | - | - |
| 1.002 | OD32314/2026-2027:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Panasonic/Daikin/Mitsubishi/ Carrier/ Bluestar:/Voltas- 1.5TR single phase Inverter split A/C unit | - | each | - | - |
| 1.003 | OD32312/2026-2027:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete wit indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Panasonic/Daikin/Mitsubishi/ Carrier/ Bluestar/Voltas:- 2.0TR single phase Inverter split A/C unit | - | each | - | - |
| 1.004 | OD32317/2026-2027:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit of tonnage 3.0 TR or cooling capacity 10550W, with minimum ISEER of 3.6, single phase split type AC unit conforming to IS fitted with inverter rotary compressor, 100% inner grooved copper tubes operating on 230V single phase AC supply, R32 /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete.(Make : Hitachi / Daikin/Mitsubishi/ Carrier/ Bluestar) | - | each | - | - |
| 1.005 | OD32318/2026-2027:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge | - | metre | - | - |
| 1.006 | OD32310/2026-2027:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge | - | metre | - | - |
| 1.007 | OD125570/2026-2027:Supply, testing and commissioning of condensate condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc complete as per specifications and as required., all complete as per direction of Engineer-in-Charge 25mm dia UPVC | - | metre | - | - |
| 1.008 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | - | metre | - | - |
| 1.009 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | - | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1467264.xls
BOQ • 0.31 MB
viewsbd.pdf
Additional Documents • 1.63 MB
Specificondtionsac-1.pdf
Additional Documents • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .