Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.8 L+₹1.3 L (2.75%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹51.0 L+₹3.5 L (7.40%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹56.8 L+₹9.3 L (19.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹42.3 L
EMD Value
₹84,600
Closing Date
4 Nov 2024, 6:00 pmClosed
GE SILCHAR
GE SILCHAR MASIMPUR MILITARY STATION ASSAM 788025
Rep replacement cleaning of service water tanks incldg conctd ws pipes tank staging platform and rep maint of AA assets BR services at Kumbhirgram overhauling of ceiling exhaust fans geysers and misc EM services at Masimpur Mil Stn under GE Silchar
2024_MES_678091_1
8911/ E8
Open Tender
Civil Works
Item Rate
180 days
Maismpur
As per tender documents
9 documents required · 9 mandatory
₹500
GE SILCHAR
₹84,600
23 Dec 2024
4 Oct 2024
7 Nov 2024
4 Oct 2024
4 Nov 2024
22 Oct 2024
11 Oct 2024 - 15 Oct 2024
Amount
B/R WORKS
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off
Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4sqm each but with shutters (without taking off shutters from the frame) and disposing off
Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and disposing off complete all as specified and directed
Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed
Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc. complete all as specified and as directed
Dismantling rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removal of debris complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
Taking down cement or cement/lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
M&L for rendering 10mm thick in cement mortar (1:6) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished fair and even without using extra cement complete all as specified and as directed
M&L for padding 10mm thick in cement mortar (1:4) mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
Supply only integral water proofing compound all as specified
M&L for formwork to soffits of suspended slabs, such as roof slab, floor slab, landings and similar works not exceeding 200mm thick for rough finished flat surfaces of concrete complete all as specified and as directed
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in slabs supported on walls, beams, etc. complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in floors, plinth protection, pavings, etc. including making spike rolling to surfaces or making impressions of expanded metal whilst the concrete is green laid in alternate bays of 3m length and joints between bays filled with 85/25 grade bitumen and sand mix @ 1:2 complete all as specified and as directed
M&L for 75mm thick plain cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregates) in flooring and similar works finished fair and even complete all as specified and as directed
M&L for 40mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregates) as in roof padding, haunching, roof kerb or similar works including applying 3kg/sqm neat cement slurry complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 7 to 8mm thick of superior quality as in floors, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
M&L for chequered cement concrete tiles, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 25mm thick of superior quality as in floors, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, laid over and including 20mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed
S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed
S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane complete all as specified and as directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putting including hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads square not exceeding 0.5sqm in each pane complete all as specified and as directed
S&F in repairs 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F 150mm extruded aluminum alloy handles, fabricated type, anodized complete all as specified and as directed
S&F 100mm long butt hinges, stainless steel, with stainless steel hinge pin, anodised and fixed complete all as specified and as directed
S&F 100mm MS butt hinges, medium weight, cold rolled complete all as specified and as directed
S&F in repairs 25mm dia fancy type MS chromium plated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of brackets, holders with funnel at ends complete all as specified and as directed
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed
M&L for framed works as in doors or gates of angle or other sections side hung with pintle hinges, stops, hand made sliding monkey tail bolts, etc. conforming to Fe 290 (grade E-165) complete all as specified and as directed
S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing new surfaces of wood and wood based materials of any description and girth, not otherwise described and applying two coats of synthetic enamel paint (tint as approved) over a coat of pink primer complete all as specified and as directed
M&L for preparing old surfaces of wood and wood based materials of any description and girth, not otherwise described and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil bound distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying one coat of oil bound distemper (white or tinted a approved) including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm over new surfaces of brickwork,concrete, etc. including all necessary staging, scaffolding, etc.required complete all as specified as as directed
M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm over surfaces of brickwork,concrete, etc. including all necessary staging, scaffolding, etc.required complete all as specified as as directed
S&F pre-painted galvalume aluminum zinc coating GI based semi-corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling herein before will be reused under this item
15mm bore
20mm bore
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores:
15mm bore
20mm bore
S&F in repairs 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia bib taps, fancy type, PTMT any colour, high pressure (minimum weight 90gms) screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, concealed type, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F in repairs 32mm dia PVC waste pipe, 900mm long, PTMT complete all as specified and as directed
S&F 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F 25mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs 25mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs gun metal globe or gate valve, 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs vitreous China squatting pan, Orissa pattern of size 580x440mm, white, with integral foot rests and 'P' or 'S' trap, connecting to flushing pipe and trap and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing complete all as specified and as directed
S&F in repairs wash hand basin, vitreous China, coloured, flat back type, of size 550x400mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed
S&F in repair 110mm bore PVC (SWR) bend of any radius with oval access door complete all as specified and as directed
S&F in repair 110mm bore PVC (SWR) bend of any radius without oval access door complete all as specified and as directed
S&F in repairs 75mm bore PVC (SWR) bend of any radius without oval access door complete all as specified and as directed
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
M&L for cleaning of internal surfaces of PVC overhead water tank including staging to a height required, etc. by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed of the following sizes:
500litres
501 to 1000litres
1001 to 2000litres
Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed of the following capacities:
500litres
1000litres
2000litres
S&F in repairs PVC lids including PVC hinges and suitable PVC locking (both sides) to water tanks at any height or location / position complete all as specified and as directed suitable for the following capacities of water tanks:
500litres
1000litres
2000litres
Supply and laying APP based polymeric membrane 3mm thick (minimum), weighting not less than 3.5 kg/sqm reinforced with polyester non woven fabric (weighting not less than 160gms/sqm) applied over primed surfaces by torching application as per manufacturer's instructions with overlaps minium 100mm on the transverse directions and 75mm in longitudinal directions including cleaning and applying one coat of cold bituminous primer (as approved by GE) @0.25litre/sqm over dried up surfaces of concrete / plastered surfaces conforming to IS 3384-1986 prior to application of membrane and one coat of aluminium paint over the membrane when fixed and dried complete all as specified and as directed
E/M WORKS
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic PVC casing capping not less than 25mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for sinking for box and making good to the surface to match the existing and M terminal boxes complete all as specified and as directed for the following:
One light point controlled by one 5A one way switch
One ceiling fan / exhaust fan point controlled by one 5A one way switch
One switch socket outlet 3 pin 5A controlled by one switch on independent board
One switch socket outlet 3 pin 5A controlled by one switch on same board
One bell point controlled by one bell push 5A
M&L for point wiring with 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic PVC casing capping not less than 25mm wide and accessories, flush on walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 2.5sqmm for earth continuity conductor and connected to common earth dolly and making good to the surface to match the existing and terminal boxes for one switch socket combination outlet 3 pin 15A multipurpose complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F 5A bell push, ISI marked, 240V complete all as specified and as directed
S&F switch socket outlet, 2 in 1, 5A flush type, universal, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 5 in 1, 5 & 16A flush type, universal, ISI marked, 240V complete all as specified and as directed
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F bell buzzer, ding dong type, 230V, single pole, 50Hz, AC complete all as specified and as directed
S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient, 230V, 50Hz, 1200RPM, exhaust fan, 300mm sweep with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type and disposing off complete all as specified and as directed
S&F MCB SP, 240V, 5 to 32A, 10kA, 50Hz, C curve, complete all as specified and as directed
S&F MCB SPN, 240V, 40 to 63A, 10kA, 50Hz, C curve, complete all as specified and as directed
S&F MCB TPN, 4 pole, 240V, 63A, 10kA, 50Hz, B curve, complete all as specified and as directed
S&F sheet metal enclosures double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed/grouted in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed for the following capacities:
8 way MCB DB, 240V, SP
4 way MCB DB, 240V, SP
S&F 1100V grade heavy duty PVC insulated aluminium multistranded conductor cable, 10sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1m apart including 4mm suspension wire, two twin core cable flat or circular including taking down old unserviceable wire and disposing off complete all as specified and as directed of the following sizes:
S&F LED bulb 10W, 5 star rated, and connecting to lamp holder complete all as specified and as directed
S&F LED street / building security light luminaire 30W, IP-66, with LED driver, etc. with all accessories prewired and 30W LED lamp including service bracket complete all as specified and as directed
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making god the disturbed surfaces, etc. complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing caping 20mm wide, heavy duty, ISI marked flush on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit/casing shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of casing/conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit / casing as per requirement at site
S&F in repairs the following items without disturbing existing wiring / fittings including making good the disturbed surfaces of wall/ceiling complete all as specified and as directed
Ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals
Switch piano flush button type, single pole, ISI marked, one way 5A, 240V
Electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked
PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V
Socket outlet, 2 in 1, 3 pin, 5A flush type, ISI marked, 240V
Switch socket combination outlet, 5 in 1, 3 pin, 5/16A flush type, ISI marked, 240V
LED tube rod 20A single side connection
S&F PVC rectangular block for mounting switches, sockets, regulators, etc. with 3mm thick plastic laminated sheet cover complete all as specified and directed of following sizes:
100x100mm and 50mm deep
175x100mm and 50mm deep
Taking down carefully exhaust fans (with or without louvers), 225 to 450mm, any type, from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Notes: (a) Cost of split pin, lock nuts, rubber bush, capacitor clamp, screws, bolts, nuts, washers, etc. shall be included in the quoted rate (b) Replaced spares will be measured and paid separately under respective items herein (c) Cost of loading, unloading, carting, etc. shall be deemed to be included in the quoted rate if fans are required to be taken to workshop for necessary repairs
Taking down carefully ceiling fans, 1200 to 1400mm sweep, any type, from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Notes: (a) Cost of split pin, lock nuts, rubber bush, capacitor clamp, screws, bolts, nuts, washers, etc. shall be included in the quoted rate (b) Replaced spares will be measured and paid separately under respective items herein (c) Cost of loading, unloading, carting, etc. shall be deemed to be included in the quoted rate if fans are required to be taken to workshop for necessary repairs
M&L for strip opening motors of ceiling fans and rewinding with super enameled copper winding wire of same gauge, aprox weight 275-325gm/fan, including insulating, varnishing, baking, etc., cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed for the following sizes: Notes: (a) RPM test of fan with suitable tachometer will be done in the presence of Engineer-in-charge (b) All T&P will be provided by the Contractor and rate quoted shall be deemed to be inclusive of same
1200mm sweep
1400mm sweep
M&L for strip opening motors of exhaust fans and rewinding with super enameled copper winding wire of same gauge, aprox weight 250-300gm/fan, including insulating, varnishing, baking, etc. complete all as specified and as directed of the following sizes: Notes: (a) RPM test of fan with suitable tachometer will be done in the presence of Engineer-in-charge (b) All T&P will be provided by the Contractor and rate quoted shall be deemed to be inclusive of same
225 to 300mm sweep
350 to 450mm sweep
M&L for removing old worn out paint from fan and blades of ceiling fans, 1200/1400mm sweep, by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and suitable sized font) in body of fan and cleaning off the premises complete all as specified and as directed Notes: (a) Painting of fans shall be done and returned within stipulated time of 3days (b) All T&P shall be provided by the Contractor and rate shall be deemed to be inclusive of same
M&L for removing old worn out paint from metal bracket fans, pedestal fans, exhaust fans with or without louvers, by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and suitable sized font) in body of fan and cleaning off the premises complete all as specified and as directed of the following sizes: Notes: (a) Painting of fans shall be done and returned within stipulated time of 3days (b) All T&P shall be provided by the Contractor and rate shall be deemed to be inclusive of same
300mm sweep
350 to 450mm sweep
S&F in repairs exhaust fan (225 to 300mm sweep) blades (set of 3) of approved design, pattern and colour, with bolts, nuts, etc. as per site complete all as specified and as directed
S&F in repairs exhaust fan (350 to 450mm sweep) blades (set of 3) of approved design, pattern and colour, with bolts, nuts, etc. as per site complete all as specified and as directed
Supply only ball bearing suitable for ceiling fans 1200 to 1400mm sweep complete all as specified of the following sizes:
Supply only condenser suitable for ceiling fans / exhaust fas, 220V complete all as specified of the following sizes:
S&F gun metal bush suitable for ceiling fans of any size/make including taking off existing worn out bush and re-assembling and testing on completion complete all as specified and as directed
S&F in repairs canopy (set of 2 pieces) suitable for ceiling fans (of any size/make), approved design, pattern and colour, with screws complete all as specified and as directed
S&F in repairs plastic bottom covers suitable for ceiling fans of any size with all fixing arrangements complete all as specified and as directed
S&F in repairs heating element 1.5kW rating as required at site including rubber washers (ISI marked), triangular/round shape with pocket for thermostat complete all as specified and as directed
S&F in repairs heating element 2kW rating as required at site including rubber washers (ISI marked), triangular/round shape with pocket for thermostat complete all as specified and as directed
S&F in repairs thermostat, ISI marked suitable for the geysers 25 to 50litres capacity, 20A, 240V AC, adjustable type, 210mm long as required at site complete all as specified and as directed
S&F in repairs thermostat, ISI marked suitable for the geysers 25 to 50litres capacity, 20A, 240V AC, fixed type, 300mm long as required at site complete all as specified and as directed
S&F in repairs clamp suitable for apparatus plate of geysers as required at site complete all as specified and as directed
S&F in repairs MS clamp suitable for mounting geysers as required at site complete all as specified and as directed
S&F in repairs indicating bulb of geysers, round / square complete all as specified and as directed
S&F in repairs 15mm bore chromium plated stainless steel braided water pipe (set of two) with brass nut and washers, unions, of good quality, 450mm long including taking down of old unserviceable hot & cold water copper / PVC flexible pipe connections from geysers and connecting up complete all as specified and as directed
M&L for dismantling of geyser, of any make, taking out inner tank, descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent leakage, filling of glass wool and re-assembling the same after repairs including replacement of required number of stainless steel screws, nuts & bolts for fixing of siphon assembly, etc. complete all as specified and as directed for the following capacities:
25litres
50litres
S&F water heater/ geyser inner tank, glass lined stainless steel, suitable for geysers, of existing make including taking down of geysers (if required) by disconnecting connections, taking out old unserviceable inner tank and disposing off and reconnecting connections complete all as specified and as directed suitable for the following capacities of geysers:
25litres
50litres
S&F in repairs apparatus plate bottom cover (syphon assembly) for geysers in two halves made out of GI sheet duly painted with two coats of synthetic enamel paint (of approved tint) complete all as specified and as directed for the following capacities of geysers:
25litres
35/50litres
M&L for preparing surfaces of geysers by rubbing with emery paper/removing rust, etc. filling cavities, etc. with filler putty and painting with two coats of white synthetic enamel paint and writing MES No. in black in legible font and refixing the same to original place and re-connecting electric and water supply lines complete all as specified and as directed for the following capacities of geysers:
25litres
35/50litres
S&F in repairs plug top 3 pin, 5A 240V heavy duty complete all as specified and as directed
S&F in repairs plug top 3 pin, 15A 240V heavy duty complete all as specified and as directed
S&F in repairs 2.5sqmm, 3core PVC insulated PVC sheathed copper conductor cable complete all as specified and as directed
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 187: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
MS AFTAB LASKAR (BID ID -3152186)
M/S M P Sharma (BID ID -3152153)
M/S TAPAN KUMAR RAY (BID ID -3156915)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .