Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC AWARDED DUE TO L1 | |
| 2 | L2₹35.1 L+₹53,264.80 (1.54%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance REJECTED DUE TO L2 | |
| 3 | L3₹42.7 L+₹8.2 L (23.7%)Rejected-Finance 5 508 509 VRAJ VALENCIA SCIENCE CITY ROAD S G HIGHWAY SOLA AHMEDABAD GUJARAT 390060 | AHMEDABAD | AHMEDABAD | GUJARAT | 390060 | L3 | Rejected-Finance REJECTED DUE TO L3 |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
8 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
SPL REPAIR TO STORE AND TT SCHOOL IN BLDG NO P-41 OF MH JODHPUR UNDER GE SHIKARGARH
2022_MES_539147_2
8775/E8
Open Tender
Civil Works
Item Rate
180 days
GE SHIKARGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SHIKARGARH
₹68,000
Yes
22 Sept 2022
18 Aug 2022
10 Sept 2022
18 Aug 2022
8 Sept 2022
25 Aug 2022
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for (such as copings, bands of any type, roof padding, kerbs, sunken etc; overall thickness and removing the dust debris etc to a distance not exc 250 meter from site and disposing the same complete all as specified and as directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of roof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing the dust debris etc to a distance not exc 250 meter from site and disposing the same (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
M&L for Form work to sides of concrete pillars, posts, struts, piers, columns and stanchion etc; rough finish surfaces complete all as specified and as directed.
M&L for Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and as directed.
M&L for Formwork for chullah hoods, chajjas through and similar items including edges, surface rough finish surfaces to receive the plaster, complete all as specified and as directed.
M&L for Form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), rough finish surfaces complete all as specified and as directed.
M&L for Form work to edges of concrete flats, floor and roofs not exceeding 20cm wide (horizontal or sloping), rough finish surfaces complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in beams, lintel up to 1.5m clear span, lintel bands etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in roof, landings, balconies, canopies and in shelves etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in chajjas etc; complete all as specified and as directed.
M&L for Reinforcement 10mm dia and over TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Reinforcement 8 to 10mm dia TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia in stirrups complete all as specified and as directed.
M&L for carrying out water proofing treatment for roofs in the following stages - (i) Rendering 10 mm thick plaster/ screed in cement mortar (1:4) mixing with water proofing compound (as per manufacturer instructions) and surfaces finished even and smooth without using extra cement all as specified . Note : (WPC shell be measured separately and paid for under respective item of schedule). (ii) First coat of bitumen primer conforming to IS-3384 @ 0.300 Kg/ Sqm over plastered surfaces. (iii) Third layer of APP modified polymeric membrane centre core of 20 micron HMHDPE outer film 20 micron both sides thickness 2.0 mm having weight 2.50 Kg/Sqm complete laid with blown type bitumen confirming to IS 702-1988 grade 85/25 @ 1.20 Kg/ Sqm complete all as specified and as directed.
Top most layer that shall act as a protective layer shall be with 40mm thick PCC 1:2:4 Type B1 using 20 mm graded stone agg finished even & smooth without using extra cement laid to slopes as required at site & filling the joints with bitumen mastic ( Mix of bitumen & sand in the ratio 1:1) made @ 0.90 to 1.00m both ways (10mm wide 12 mm deep) made while the conc is still green all as specified and as directed.
M&L cool roof vitrified tiles (white or light shade as approved) of size 300x300x10mm thick fixed with spacers over 3mm thick high polymer modified grey cement based tiles adhesive and grouted with epoxy grout complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 type C-1,using 20mm graded stone aggregates as in coping to parapet walls including necessary formwork complete all as specified and as directed.
Supply only integral water proofing liquid ISI marked
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15cm thickness below or above ground level including floor finishes and removing debris from the site all as specified and as directed.
Dismantling glazed tiles/ kota stone/ terrazzo tiles any type as in dado/ skirting etc; including cement mortar bedding ( but not backing ) complete all as specifide.
M&L for non skid ceramic tiles 10mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
M&L for non skid ceramic tiles 10mm thick (square/ rectangular) as in skirting / dado, cut out of ceramic tiles of size exceeding 0.18 sqm but not exceeding 0.38 sqm, (Matching with floor tile of the same room) set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of approved shade and pattern of size 350x 250x7mm/ 450X350X7mm/ 300X450X7 to 8mm thick or any other nearer size as approved by Engineer incharge in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specified and as directed.
M&L for 16 -18mm thick granite (colour as approved) work (table rubbed and polished) in steps, shelves, jambs, pillars, window-cills, cooking platforms (vertical/ horizontal) and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 10mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
M&L for mirror polished machine cut Kota stone slab 15-16 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 and jointed complete all as specified and as directed.
Dismantling of stone/ brick work masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work, serviceable stone aside for reuse and removing unserviceable material in low laying area complete all as specified and as directed.
M&L for squared rubble walling jodhpur type, brought upto course, well bonded bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
All as per Srl Item No 28 above but, except stone complete all as specified and as directed.
Extra over for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling,Jodhpur type, brought upto courses all as specified and as directed.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed
M&L for rendering 15 mm thick in CM 1:6 over stone masonary, concrete surfaces, finished even and smooth (without using extra cement), all as specified and as directed.
M&L for 15 mm thick rendering on stone masonary wall surfaces in CM 1:4 finished fair and even all as specified and as directed.
M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 sqm each and removing from site or to store as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store as directed by Engineer-in-Charge.
S&F of pressed steel framed made out of 1.25mm thick MS sheet, of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc., complete all as specified
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in lintels upto 1.50 m clear span, cills , steps, seismic and other similar bands, copings, kneelars, apex stones, bed plates, bed blocks of hold fasts etc including necessary form work complete all as specified
S&F of factory made 35 mm thick plain framed, panelled shutters (two panel) with 2nd class hard wood rail and style with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified.
S&F of Factory made steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8/10mm square bars as directed by Engineer incharge, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. (with provision of fixing for cooler if required) all as shown on drawing No CEJZ/TD/20 sheet 1/3 to 3/3 fixed in repairs i.e, incl taking down and removal of old steel windows from site or to store complete all as specified and directed. Note:- Guard bar/ grill shall be measured and paid separately under respective item of Sch 'A'.
M&L for fabrication of aluminium powder coated door, window any pattern & design (openable with hinges, sliding, tilt and turn, casement , fixed type, villa type, ventilators) fabricated with anodized aluminium rectangular or any type section in frame with approved design & patterns including provn of fixing galvanised mild steel wire cloth, glass pane etc; fixed in position all as specified and as directed. Note:- Glass pane & galvanised mild steel wire cloth shall be measured and paid separately under respective Items of Sch 'A'.
S&F of sheet glass ordinary quality 4.8 mm thick and glazing with aluminium beading & rubber gasket in aluminium frame any size of pane complete all as specified and as directed.
S&F of sheet glass ordinary quality 4 mm thick and glazing with oil putty or fixed with wooden beads or fixed with rubber gasket in squares any size of pane complete all as specified & as directed.
S&F of galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & as directed.
S&F double action hydraulically single cylinder stainless steel floor door closer covered with 1.25mm thick stainless steel cover plate, governing pivot, suitable for 900-1200mm door width and 70-90kg weight capacity fixed in position with stainless steel screw etc complete all as specified and as directed.
Mild steel round bars welded to steel windows or ventilators as in guard bars framed or unframed complete all as specified & as directed by Engineer-in-Charge. Note:- Guard bars shall be factory welded & given one shop coat of red oxide or zinc chromate primer. Cost of factory welding & Shop coat of primer is deemed to be included in quoted rates.
S&F Aluminium handles, cast type,anodised, 150 mm long and fixed with steel screws complete all as specified.
S&F Mild Aluminium anodised, barrel tower bolts of extruded section, 150 mm long and fixed with steel screws complete all as specified.
S&F 300 mm long sliding door bolt, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.
S&F 100mm four levers brass mortice lock vertical type with two Nos of keys and fixed with aluminium door complete all as specified and as directed.
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F of framed work as in doors chowkats of MS angle iron or MS hollow square/ rectangular any type/ size with gusset plates, rails, braces,cooler stand, chajja framed, water tank frame, complete drilled for fixing etc; to be prepared for hanging with and including hold fasts and locking arrangements as required confirming to FE- 290 (Gde-E- 165) complete all as specified and as directed.
S&F of powder coated aluminium anodised deco grill weighing not less than 1.40 kg/ sqm and fixing necessary joining cleats/ frame etc; complete all as specified.
Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide.
Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide.
Taking down 25mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide.
S&F of 15mm bore steel water tubing medium grade galvanised with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
S&F of 20mm bore steel water tubing medium grade galvanised with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
S&F of 25mm bore steel water tubing medium grade galvanised with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
Fixing only 15mm bore old servisable steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
Fixing only 20mm bore old servisable steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
Fixing only 25mm bore old servisable steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
S&F in repair 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified.
S&F in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified.
S&F in repair 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified.
S&F for 2000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered and white colour hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified and as directed.
S&F in repair PVC SWR type 'B' socketed rain water pipes 110mm dia conforming to IS: 4985/ IS: 13592 complete all as specified and as directed.
S&F in repair PVC SWR bend/shoe of PVC 110mm dia suitable for 110 mm bore / dia PVC SWR rain water pipes complete all as specified and as directed.
Dismantling boarding of any description fixed in any position with nails, complete all as specified.
S&F in repair Gypsum board 6-8mm thick in ceilling fixed with screw as per manufacturer's instructions, plain/ colour fixed with steel snap grid (powder coated bottom side) with 'T' and 'L' (25mmx30mmx1.00mm thick) section of size 600mm x 600mm placed in ceiling 'L' section fixed to wall with PVC rawal plugs and steel screws @ 600mm centre to center, including provided 5.0 mm dia galvanised bars/ wire suspended @ 1.80 mtr centre to center both sides proper hanging arrangements and maintain levels with adjustable clips, complete all as specified and directed. (Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing).
Preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cm and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces all as directed by Engineer-in-Charge.
Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint on new plastered surfaces all as directed by Engineer-in-Charge.
Preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified.
Preparing old plastered surfaces brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying one coat of distemper oil emulsion on old plastered surfaces all as directed by Engineer-in-Charge.
Preparing old surfaces incl brooming surfaces, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered and painted surfaces and M&L for applying one coat of cement base paint on walls etc., complete all as specified and as directed.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
M&L for point wiring (Modular) complete for one light point / exhaust fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Make of wire : Polycab / RR Kabel / KEI. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2. The cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate
All as per srl item no. 03 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board.
All as per srl item no. 03 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
All as per srl item no. 3 here-in-before but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire complete all as specified and directed by Engr-in-Charge
S & F Modular switch 1 way 6A , 1 module size complete all as directed.
S & F Modular switch 1 way 16A , 1 module size complete all as directed.
S & F Modular Socket , 6 A , 5 Pin , 2 module size complete all as directed.
S & F Modular Socket , 6 A / 16 A , 5 Pin , 2 module size complete all as directed.
S&F of modular type regulator 2 module A/C 240 Volts.
S&F of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
S&F of LED light fitting 1 X 20/22 watt (4 feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed.
S&F of LED light fitting 1 X 10 watt (2 feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed.
S&F of recess mounted LED light fitting of 2' x 2' size, suitable for false ceiling, 36 Watt, 6000K white light, metal body with white colour outer finish and acrylic diffuser including LED driver / transformer, spring loaded clips for easy mounting and making all electric connections complete all as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and making all necessary elect connection and depositing old unserviceable fan in E/M yard, complete all as specified and directed.
M&L for Taking down Spilt/window type AC (indoor and Outdoor unit complete) any capacity and keep in safe custody and refix the same after necessary ceiling repair work has been completed. Making all necessary electric connection, copper tube incl insulation with gas filling as reqd at site.
M&L for Taking down wall mounted fan from existing position and keep in safe custody, refix the same after necessary building work has been completed. Making all necessary connection complete all as specified and directed.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified
S&F in replacement of Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 125A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Make : Havells Cat Part No DHDLVSRWGOFO04 / Schneider Elect / Legrand / ABB. Note : 1. MCCB & MCB will be measured and paid separately under respective items. 2. Quoted rates are included for blank plates. 3. All wires to be properly connected with copper lugs.
S&F in replacement of MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 125 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed.
S&F in replacement of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 8 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Note : 1. Blank plates will be included on the quoted rates. 2. All wires to be properly connected with copper lugs. 3. MCB will be measured and paid separately.
S&F of Copper Bus bar chamber 400 Amp rated 415 volts made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 45 & IK 09 protection, dust and vermin proof, etc and making all necessary connections, complete all as specified and directed.
S&F in replacement of MCB, C Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed.
S&F in replacement of MCB, C Curve type, 10 kA, 40Amp, SPN with over load and short circuit protection, complete all as directed.
S&F in replacement of MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed.
Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
Supply, laying, testing and commissioning of semi conducting compound conductor screened PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm x 3.5 core confirming to IS 7098 Part-II, suitable for earthed system complete all as directed.
Excavation in trenches in soft / loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
M&L for Sand cushioning to protection of underground cables, laid 8cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18cm thick, complete all as specified and directed. Note : Punned thickness shall be measured and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
Supply and fixing / laying galvanised pipe 50mm bore medium grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
M/S KAUTILYA GARG
M/S gayatri construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .