Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.8 LAccepted-AOC C 9 53 SECTOR 8 ROHINI NEW DELHI 110085 | NEW DELHI | NEW DELHI | DELHI | 110085 | 1 | Accepted-AOC accepted amt | |
| 2 | 2₹47.3 L+₹2.4 L (5.25%)Rejected-Finance H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | 2 | Rejected-Finance other than L1 |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
15 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE P DDN
GE P DDN
PROVN OF TRANSIENT FACILITY AT WOLFBURN ESTATE IN LANDOUR AT MUSSORIE.
2023_MES_608949_1
GE P/ DDN/09 OF 23-24
Open Tender
Civil Works
Item Rate
90 days
DDN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE P DDN
₹87,000
Yes
26 Sept 2023
14 Jul 2023
17 Aug 2023
14 Jul 2023
15 Aug 2023
27 Jul 2023
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness or similar pattern roof coverings complete all as specified and directed.
Dismantling wall and ceiling boards, fibre or pulp, insulation etc. in insulation boards slabs, blankets any thickness incl cover fillets complete all as specified and directed.
Dismantling timber scantling 40 sqcm & over in section unframed in any position complete all as specified and directed.
Demolition of brickwork/ stone boulder masonry built in cement mortar as in walls, parapets and pillars including all quoins, arches, pillars, etc.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for any type of soil compete all as specified and directed
M&L for plain Cement concrete 1:4:8 Type D-2 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified
Use and waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified
M&L for Reinforcement cement concrete in 1:2:4 type B-1 (20 mm graded stone aggregate) as in slabs supported on walls, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified
M&L for Mild steel TMT bars 5mm dia and over but including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement 1:6 complete all as specified
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
Returning, filling in including spreading, levelling watering and well ramming in layers not exceeding 25 centimetre in any type of soil complete all as specified and as directed.
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
M&L for cement concrete 1:2:4, type B-1 as in n lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, copings , benching, bedplates etc. including all necessary formwork etc. complete all as specified.
M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and fair complete all as specified
M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and fair Complete all as specified
M & L 10 mm thick rendering on celling surface in cement mortar 1:3 mixed surface finished even and smooth complete all as specified
S&F rolled mild steel tubular sections (round/ square/rectangular as directed) as in main and cross beams, hip and jack rafters, purlins where connected to common rafters fixed with and including angle cleats or other connecting plates.
M&L preparing new steel or iron surfaces over 10 cm width or girth and applying two coats of black Japan paint over one coat of red oxide primer complete all as specified and directed.
S & F Pre Painted galvalume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. Make JSW Colour on + ISI Certified / TATA Dura Shine ISI Mark
S & F pre-painted galvalume aluminium zinc coating GI based plain steel 0.50 mm thick for ridge cover of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. Make JSW Colour on + ISI Certified / TATA Dura Shine ISI Mark
S&F 0.45 mm thick prefabricated, colour coated galvalume aluminium zinc coating GI based plain sheeting of any colour as directed by GE having tensile stength of 550 Mpa as in vally gutters/ eaves gutters complete all as specified and directed. Make:- JSW coloron +, Tata durashine ISI Mark.
S&F pine wood (v grooved board 10-12 mm thick rectangular board) ceiling with and including timber framework and polished one or more coat of clear polish all as directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified
M&L earth filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone agg as in sub base complete all as specified and as directed.
M & L 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in levelling course to floors complete all as specified
M&L glazed ceramic colour tiles size 300 mm x 600 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified
M&L non skid ceramic coloured tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified
Material and labour for 12mm thick laminated interlocking wooden flooring and fixed as per manufacturer's instruction complete all as specified and directed by Engr-in-Charge. Note :- Colour/ shade of wooden flooring shall be as directed by Engineer -in Charge.
S&F 5mm thick prelam PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. complete all as specified and directed by Engr-in-Charge. Note :- Colour/ shade of wall panelling shall be as directed by Engineer -in Charge.
Taking down chowkhats or frames with shutters n. exc 1.5 sqm each without taking off shutter from the frame complete.
Taking down chowkhats or frames with shutters exc. 1.5 Sqm but not exceeding 4 Sqm each complete.
S&F Pressed steel frames for doors with one or more rebates of size 165x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F 30 mm thick flush shutters, solid core construction, with block board core and both face covered with decorative face veneer with lipping/frame to match complete all as directed.
S&F 30 mm thick Ist class hrad wood (Teak) glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided in to square with mitred and rebated sash bars any number with edge of sash bar and framing moulded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
All as per above item but for windows etc provided with stiles and rails as specified in SSR Part-I, Section 8 clause 8.24(b).
All as per item No above but window without sash bars.
M&L two or more coat of melamine polish to joinery complete all as specified
M&L for preparation of surface and applying two coat of plastic emulsion paint over and complete all as specified
M&L for preparation of surface of wall and applying a coat of exterior grade primer over 2-3 mm thick exterior wall care putty complete all as specified
M&L for applying two coat of exterior emulsion paint on wall and ceiling complete all as specified
S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed.
S&F 20mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete.
S&F vitreous china rimless blind installation wall hung WC with UF soft close slim seat cover hinges, accessories set size 360x 500x 335 mm Make Jaquar Cat part No KUS-WHM-359538IUFSM including single piece concealed cistern body cat part No JCS-WHT-2431FP and control plate D arc cat Part No JCP-CHR-372415 cistern or make of Cera cat Part S1044167 P-trap incld single piece concealed cistern cat No B1110111 or Parryware all as specified and directed.
S&F vitreous china Wash Basin table top 595x435x185mm including stainless steel bottle trap and 40 mm dia GI pipe up to Floor trap complete all as specified and directed by Engr-in-Charge Make : Jaquar Cat Part No KUS-WHT-35901 or make of Cera cat Part 52020101 ivory colour or Parryware.
S&F vitreous china wall hung wash basin size 590x490x185mm with padestalincluding stainless steel bottle trap and 40 mm dia GI pipe up to Floor trap complete all as specified and directed by Engr-in-Charge Make : Jaquar Cat Part No LYS-WHT-38801 and LYS-WHT-38301 or make of Cera cat Part S2040104 wash basin and half pedestal S2090103 ivory colour or Parryware.
S&F 15mm bore chromium plated brass connection 450mm long with 2 Nos connector incl PVC washer complete Make Jaquar Code ALD-803B or make of Cera or Parryware.
S&F overhead Shower 150X150mm Squarel Shape Single Flow (ABS Body Chrome plated with grey face platee) with Rubit Cleaning System including showe arm, fixing to steel pipe or union complete all as specified Make Jaguar (Cat part No : OHS-35495) or make of Cera cat part No F7010111SS or Parryware.
S&F brass chromium plated centre hole basin mixture with regular spout without pop up waste system with 450 mm long braided hoses complete all as specified and directed by Engr-in-charge Make : cat Part No:- QQT-7167B or make of Cera cat part No F-2002461 or Parryware.
S&F wall mixture with provision for overhead shower with 115 mm long bend pipe on upper side connecting legs and wall flange connecting to steel pipe or union complete all as specified and directed by Engr-in-charge Make Jaquar cat part No QQT-7273UPR or make of Cera cat part No 1003403 or Parryware.
S&F 15mm bore brass chromium plated angle cock fancy tape with CP brass cup and screwed down to GI pipe Make:Jaquar Cat Part No LYR-38053 or make of Cera cat part No F-1017151 or Parryware
S&F 15mm bore brass chromium plated long body Bib cock with wall flangea nd screwed down to GI pipe Make:Jaquar Cat Part No CON-107KN or make of Cera cat Part No F-1017151 or Parryware
S&F Towel Rack with Lower Hanger (Stainless Steel) with hook complete all as specified and directed Make Jaguar (Cat Part No: ACN-1181FHS) or No F-5003101 or Parryware.
S&F in repair Corner glass shelf ( with Brackets) fixed with rawl plug and washer complete all as specified and directed by Engr-in-charge Make cat part No ACN-1173 of Jaquar or Cera No F-5005103 or Parryware.
S&F chromium plated toilet paper holder fixed on wall with PVC Rawal plug complete all as directed Make Jaquar code no-ACN-1151N or cera No F-5004110 or Parryware.
S&F chromium plated soap dish holder with PVC Rawal plug complete all as directed Make Jaquar cat part no-ACN-1131N or cera No F-5006106 or Parryware.
S&F vitreous china wash down water closet padestal pattern size 510x 335x395 mm Cat part No S1053121 of CERA with S trap with slim seat cover including low level conventional twin flush cat part no S1061106 and cat no B1810110 fittings complete all as directed make of Cera or Parryware
S & F 25 mm dia Stainless Steel 1 mm thick curtain rod including fancy type brackets, decorative end caps etc. fixed to wall complete all as specified an directed.
S&F 5mm thick looking mirror fixed to wall with glass with teakwood beading fixed to wall complete all as specified and directed by Engr-in-charge
S&F Health Faucet (ABS Body) with 1.20 M Long PVC Tube and wall Hook screwed down to GI pipe or union/angle valve complete all as specified and directed by Engr-in-charge Make Jaquar Code No- ALD-565 or make of Cera or Parryware No F-8030109AB.
S&F anti cockroach grating jali 100x100 mm fixed complete all as specified and directed by Engr-in-charge
S&F 100mm dia centrifugally cast iron spun pipe in any length with or with ears, with cement joints laid in trenches or in floors or in wall.
S&F 75mm dia centrifugally cast iron spun pipe in any length with or with ears, with cement joints laid in floors or in wall.
S&F 75mm dia centrifugally Cast iron spun floor trap with grating including jointing to waste pipe fixed in cement concrete type B 1(1:2:4)
S&F in repairs 1000 litre rotational moulded triple layer polyethylene water storage tanks white colour (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part-I complete all as specified and directed.
S&F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F 20mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed.
M & L 16 mm thick granite (colour as approved by GE) stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in platform / dado / skirting etc. including 15 mm thick cement screed bed 1:6 CM in horizontal or vertical surfaces including grinding the edges half round and polishing complete.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm.
S&F light shade virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, infloors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Excavation over area not exceeding 1.5 m deep and getting out in any type of soil
Excavation over area exceeding 1.5 m but not exc 3.0 m deep and getting out in any type of soil
S&F PVC (SWR) pipes 110 mm in boresingle socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed.
M&L for PCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in bed of drain pipes concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested, as shown on drgs for 100mm dia complete all as specified & directed.
M&L for PCC 1:3:6 Type C-2 (using 40mm graded stone agg) as in foundation filling and mass concrete as in bed of Manholes etc complete all as specified & directed.
M&L for brick work in cement mortar 1:4 with sub class `B’ bricks straight or curved on plan exc 6m mean radius with old size bricks complete all as specified & directed. (for manhole etc).
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) as in surface channel bed/drains/in manholes all as specified laid to slope and finished surface even and smooth complete all as specified & directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms moulds, mitered/stopped ends etc. complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick workor concrete surfaces (inside MH) in cement mortar 1:4 using water proofing compound @ 2% by wt of cement incl finishing the surface even and smooth w/o using extra cement. (WPC shall be measured & paid separately) complete all as specified & directed.
Supply only integral water proofing compound complete all as specified & directed.
M&L for pre cast RCC cover slab for manholes Type B-1, 1:2:4 (using 20mm grade stone agg) set in cement mortar 1:6 complete all as specified & directed ( Reinforcement shall be measured & paid separately)
M&L form work to side and soffits of slabs supported on wall rough finished surface of concrete flat complete all as specified.
Construction of Soakage wells (1.8 M dia X 3.0 M effective depth) excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with RCC 1:2:4 cover slab and CI manhole cover, interconnecting pipes of RCC/DWC complete, filled with brick bats complete all as specified and shown in drgs. Note:- Ref TD 309, sheet 1/4 to 4/4
Walling of random rubble uncoursed, well bonded bedded and solidly hearted built in CM 1:6
Extra over stone walling for hammer dressing to facing stones and dressing of face beds and joints brought up to courses with max depression on face from straight edge held against the dressed surface n exc 40 mm
M&L rendering 15 mm thick on other than fair faces of brick work or stone masonry surfaces in CM 1:4 including finishing the surface even and smooth without using extra cement.
M&L for PCC 1:3:6 type C1(using 20 mm graded aggregate ) as in copings finished even and smooth using extra cement.
S&F 375 mm size legnth brass skelton tower bolts with cast brass plate and staples and rolled or drawn brass bolt and fixed
S&F 100mm size brass flush bolt typw 2 and fixed flush
S&F 250,mm brass sliding ndoor bolt with sand or die-cast brass hasp, staple (bolt typw) and fixing bolt with rolled or draw n brass bolts and fixed
S&F 100mm size brass butt hinges medium weight cold rolled mild steel
S&F 75mm size brass butt hinges medium weight cold rolled mild steel
S&F 150mm size extruded brass handles fabricated type polished
S&F 100mm size extruded brass handles fabricated type polished
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and averaage widh of aperture 1.40mm and fixed with stainless steel wire staples
M&L 4mm thick sheet glass irdubary quality ub sqyares n exc 0.5 sq m each panel
Desludging and dewatering of existing septic tank soakwall of any description and depth including removal and refixing of sewage line required for soft disposal of sluge and foregin matrial by menual and outside the MOD land not deferminate to public health including loading/unloading digging out of pit etc complete all as specified and directed.
M&L for new point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings with cutting chases and all accessories with suitable size of sunk type cast iron or pressed steel terminalmodular box , duly painted for mounting of modular switches, sockets, fan regulator etc with modular cover plate sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed. (Note: Colour code shall be maintained as per IE rule) (a) One light point point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per item No 101 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm.
S&F Modular switch 1way 6A ,1Module compete all as specified and directed
S&F Modular switch 1way 16A ,1Module compete all as specified and directed
S&F Modular socket ,6A-2/3 pin combined 2 module compete all as specified and directed
S&F Modular socket ,6A/16A -2/3 pin combined 2 module compete all as specified and directed
S&F for colour cover plate with frame,2 Module compete all as specified and directed
S&F for colour cover plate with frame,3 Module compete all as specified and directed
S&F for colour cover plate with frame,4 Module compete all as specified and directed
S&F for colour cover plate with frame,6 Module compete all as specified and directed
S&F for Metal flush box 2 module compete all as specified and directed
S&F for Metal flush box 3 module compete all as specified and directed
S&F for Metal flush box 4 module compete all as specified and directed
S&F for Metal flush box 6 module compete all as specified and directed Note:- Make for item No 101 to 117 shall be Legrand / Crabtree / Havells to be incorporated.
S&F Bell switch paino flush button type 5 Amp complete all as specified.
S&F ding dong bell AC 230 V single pole complete all as specified and directed .
S&F Modular Fan Step regulator ,120W- 2Module compete all as specified and directed
S&F ceiling rose, 3 terminal PVC polycarbonate, isolated body 230 V AC compete all as specified and directed.
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings.250 V AC compete all as specified and directed
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings with chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
S&F sheet metal enclosures 240 volt with 200 amps rated copper bus bar for double door 12 way IP-43DB's lk-09suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge.
S&F MCB double pole 240 Volt 10 KA 40-63 Amp 'B' series conforming to ISI marked complete all as specified & directed .
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed .
Supply & fix LED light fitting 1x20 W,220V AC decorative box type with driver ,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: 1) Philips Cat Part No - (a) TMC5021XT LED 22W (For Batten) (b) MAS LEDTUBE 18W865T-81 (Tube) 2) Crompton Cat Part No - (a) DIJB12LT.8.20(For Batten) (b) LT 8.20-865(For Tube) 3) Havells Cat Part No - (a) REGAL BATTEN BUPT01X20W JSBS (For Batten) (b) PHOTONULTRAE2.01213T118WLED 865 PC(For Tube).
S&F mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size compete all as specified and directed
S&F LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size compete all as specified and directed
S&F LED Recessed downlight with preasure die -cast aluminium housing for effective thermal management and high transmission factor PMMA diffuser for better performancesuitable for 15 wartts LED 6500K and including connecting up with twin core twisted flexible copper conductor cable of suitable size compete all as specified and directed
S&F LED light fitting decorative wall mounting Brass bracket suitable for 5 watts LED bulbwith frosted glass with and including one no 5 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size compete all as specified and directed
S&F Bed side lamp fitting LED 6 watts capacity and including connecting up with twin core twisted flexible copper conductor cable of suitable size compete all as specified and directed
S & F high efficiency LED bulbs 1 X 9 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
Supply & fix exhaust fans steel body AC single phase 230 V of size 300 mm sweep with blades ,frame and louvers.M&L for making Holes of suitable size and making good disturbed surfaces as directed by Eng-in-charge deemed to be included in the quoted rate. Note: (1) Old Exhaust fan of any capacity shall be deposited in E/M storeyard . Make:-1)USHA( aj Model No -S.PH TURBO HDEF 300mm 2) Crompton Model No-.TRANS AIR 300mm 3) Havells Model No - VENTIL AIR DB 300mm
Supply and fix water heater ,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre,BEE 5 Star rated complete with all accessories such as safety valve ,thermostate ,NRV, connection pipe compete all as specified and directed Note:(1) Old Water Heater of any capacity shall be deposited in E/M storeyard. Make:-1) USHA Model No -MISTY25 Liters Digital( 2) Crompton Model No-.ARNO NEO 25L 3) Havells Model No - MONZA EC 25L
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminum conductor of size 35 sq mm 3.5 core
All as per above but 10 sqmm 2 core
Supply and erecting steel tabular swaged pole in true vertical shape complete with CI base plate, 6mm thick and 300X300mm size, final taper plug, bolts & nuts, and washer all as IS-2713 (Part-II) (1980 revised) including two coats of aluminum paint over a coat of red oxide zinc chromate primer and two coat black bituminious paint for portion embedded in concrete all as specified of type 410 SP-31,9.0 mtr long all complete. (Note:- Excavation & concrete shall be measured and paid separately). Make: Jindal/National tube/Bharat Conduit.
Supply and Fixing Integral LED Street Light Luminaire comprising of high pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 36/40 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI bracketed made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed. Make:- 1) Bajaj Cat Part No -ENXT P 36L WH PO PC SD 2) Crompton Model No-.LSTS-40-CDL-M(Astra Neo 3) Wipro Cat Part No - LR02-451-XXX-57-G1
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 32x6mm GI earth Strip as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
S&F GI pipe medium grade, laid in trenches including testing complete with fittings such as flanges, unions, reducer, sockets bends, elbows, tee, checknuts, caps, plugs etc ISI marked of size 25mm complete all as specified and directed
S&F gun metal gate valve heavy duly ISI marked with iron wheel head, screwed both ends for iron pipe of size 25mm complete all as specified and directed
S&F pressure booster pump 1 HP, including connecting testing with existing pipeline complete with connecting accessories compete all as specified and directed make Kirloskar Model CPBS-73624 V or equivalent make of Crompton.
S&F chromium plated towel ring fixed with rowel plug complete all as specified and directed make cera No-F-5007105 or equivalent make of parryware.
M/S VIJAY TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .