Tender Value
₹17.0 L
EMD Value
₹34,086
Closing Date
26 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation and Commissioning of split type AC system and Repairing and servicing of ductile AC machine at the building of Nazrul Kalakhetra, 3rd floor for proposal of Film School as desired by the Director, SRFTI, Kolkata
2022_CEPWD_32212_1
60/EE/DNIeT/MECH.DIVN/AGT/2022
Open Tender
Civil Works - Others
Works
60 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹34,086
19 Nov 2022
15 Sept 2022
26 Sept 2022
15 Sept 2022
26 Sept 2022
15 Sept 2022
Amount
Providing for installatioin, testing and commissioning of Split type High wall 1.50 TR (4,500 Kcal/ hr.) ±2% split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting (Evaporator & Condenser must have copper pipe) suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating , 50Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.
Providing For installation of Split type High wall 2.00 TR (6000 Kcal/ hr.) ±2% split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting (Evaporator & Condenser must have copper pipe) suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating , 50Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.
Standard installation of 1.5 TR/2.00 TR capacity High Wall Split Air Conditioner i/c providing of electrical plug top of required capacity, flling up/ repairing of drilled portions by cement mortar, painting etc. as per direction of the Engineer-in-Charge.
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line with installation and Providing and fixing of necessary electric cable between indoor and outdoor unit beyond the standard length as per direction of the Engineer-in-Charge.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
Providing of Minimum 4 TR( 4-5TR not lessthan 12000Kcal/hr)Vertical split AC unit with hermitically sealed compressor operating on R22/R-410 A /non CFC equivalent refrigerants suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) cooling, B) Dehumidify, C) Air circulation, d) Filtering. etc. complete as per direction of Engineer -in- charge
Installation and commissioning of 3 TR /4,5 TR vertical split AC unit with vaccumising, Nitrogen pressure testing, first charge of refrigerant including providing Refrigerent & cable connection from MCB to Outdoor/indoor etc. (upto 3mtr) complete as per direction of the Engineer in Charge .
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. 3/4" OD / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. 1/2" OD / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing and fitting-fixing of VI pad for outdoor unit for Vertical split AC unit as per direction of the Engineer in Charge .
Providing, fitting & fixing of cradle/suitable structure (Base) made of M.S. angle of 65 x 65 x 6 mm, nuts & bolts etc. i/c painting, fitting, fixing, grouting for placement of outdoor unit complete for vertical split AC as per direction of the Engineer-In-Charge.
Providing, fitting & fixing of suitable structure (Base) made of M.S. angle of 65 x 65 x 6 mm, nuts & bolts etc. i/c painting, fitting, fixing grouting for placement of indoor unit, the M.S base should be enclosed by 12 mm water proof ply with formica pasting/ACP sheet complete for vertical split AC as per direction of the Engineer-in-charge.
supplying and providing f of 8.5 TR compressor as per direction of the Engineer in charge
Dismantling of old compressor and fitting fixing of new compressor with brazing equipment as per direction of the Engineer-in-Charge.
Leak testing and flashing nirtogen for entire refrigerant circuit and vaccuming etc as per direction of the Engineer-in-Charge.
Supply of R-22 gas and charging for 8.5 TR ,5.5TR,4TR Ductable mavhine as per direction of the Engineer-in-Charge.
Providing and fittimg fixing of dryer etc complete work as per direction of the engineer in charge.
Providing and fittimg fixing of contractor etc complete work as per direction of the engineer in charge.
Servicing of duct AC 2 pump 8.5 TR 2 nos ,5.5 TR pump 1nos , 4 TR pump 1nos, as per direction of the Engineer in charge.
Repairing and fitting fixing for condensor motor as per the direction of the Engineer in Charge.
Providing and fittimg fixing of Expansion Valve for 8.5 TR etc complete work as per direction of the engineer in charge.
Providing and fittimg fixing of PCB controller for 8.5 TR etc complete work as per direction of the engineer in charge.
Eastern Commerce
stage.html
html • 0.04 MB
techsummary_32723.pdf
PDF • 1.88 MB
finsummary_32723.pdf
PDF • 1.88 MB
AOCN.pdf
PDF • 0.95 MB
finance_32723.pdf
PDF • 0.17 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .