Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹42.7 L+₹5.8 L (15.8%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹43.0 L+₹6.1 L (16.5%)Rejected-Finance TRIVANDRUM | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹43.3 L+₹6.4 L (17.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹44.0 L+₹7.2 L (19.5%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49.8 L
EMD Value
₹99,500
Closing Date
9 Oct 2023, 5:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
PROVISION OF 0.03 MW SOLAR POWER PLANT FOR LAO OFFICE SPECIAL REPAIR REPLACEMENT OF LT OH LINE TO LT UG CABLE IN CSD RESIDENTIAL COMPLEX AND CERTAIN MINOR WORK UNDER AOR OF GE UTILITY AMBALA CANTT
2023_MES_617460_1
CA NO GE U AMB T 59 OF 2023-24
Open Tender
Civil Works
Item Rate
150 days
GE UTILITY AMBALA CANTT
As Per Tender Document
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹99,500
31 Oct 2023
6 Sept 2023
11 Oct 2023
6 Sept 2023
9 Oct 2023
22 Sept 2023
6 Sept 2023 - 13 Sept 2023
Amount
Design,Supply, fixing, Installation, Testing & Commissioning of Grid connected roof top Solar Power Plant of 30KWP including Solar Panels, Solar Inverter, Module Mounting Structure and comprising of following:- (i) Solar PV module Pmax 550Wp C-Si 72 cells Efficiency not less than 16.20, Voc 45.00, Isc 9.03, AR coated antimony free glass material with connecting Junction box complete all as specified and directed.Make :- MNRE / SECI Approved (Country of origin- Made in India)
Design,Supply, fixing, Installation, Testing & Commissioning of Grid Tied Inverter - 3 Phase / 415 Volts / 50 Hz having separate MPPTs with SPD having efficiency greater than or equal to 98% with Display Option, inbuilt LED interface with RS485 and compatible for online monitoring system suitable for ambient temprature of Ambala (Haryana), protection IP-65, Over-Voltage / Under-Voltage Protection complete all as specified and directed.Make - ABB / Waree / Exide / Havells / TATA / Solis - 35.0 kW
Design,Supply, fixing, Installation, Testing & Commissioning of Protection Devices - (i) DC Solar distribution Box to collect the DC output from Array junction Box and supply to Inverter weather proof for outdoor applications and including DC MCB / DC Fuse - 30 A rated of proper rating depending upon the capacity of the power plant complete all as specified and directed Make :- Schneider / Siemens / ABB / L&T / Phoenix Contact (ii) AC Solar distribution Box to collect 3 phase AC output from invertor and connect with grid meter for outdoor applications and including MCB / MCCB of proper rating for capacity of plant 30 KW Complete all as specified and directed.Make :- Schneider / Siemens / ABB / L&T /Phoenix contact with AC SPD
Supply, fixing and assembling of Module Mounting Structure with Hot Dip Galvanised MS / Galvalume Mounting structure for mounting of Minimun 3.0 MM Thickness, Legs & Rafters should be erected with C-Lip of modules / array / panels etc such structure should have angle of inclination as per the site conditions to take max insolation, mounting structure shall be designed to withstand the speed of 150 KM per hour, having fastening arrangements, grouting, clamping etc, be provided to secure the installation against specific wind speed complete all as specified. Note:- The mounting structure steel shall be as per latest IS, and galvanisation of the mounting structure shall be in compliance. structural material shall be corrosion resistant and electrolytically compatiable with the materials used in the module frame, its nuts and bolts. The fasteners used should be made up of mild steel. The structures shall be designed to allow easy replacement of any module .
Supply and fixing of 3 phase DLMS type integrated meter with inbuilt CT& GSM Modem energy meter having LCD display, 50 Hz ± 5%, Provision of sealing on mains cover and terminal cover, IP 51, tamper proof, inbuilt battery back up to activate its display in absence of power, Optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, (3X 240V (P-N), -/5A) Complete all as specified and directed by Engr-In-Charge. Make : Secure / HPL / Siemens / L&T/Schneider
Supply and fixing of Bi-directional 3 phase DLMS type integrated meter with inbuilt CT meter having LCD display, 50 Hz ± 5%, Provision of sealing on mains cover and terminal cover, IP 51,tamper proof, inbuilt battery back up to activate its display in absence of power, Optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, (3X 240V (P-N), -/5A) Complete all as specified and directed by Engr-In-Charge. Make : Secure /HPL/Schneider
Supply and Supply of maintenance free chemical earthing using pure copper electrode dia 50 mm 3 mtr long and 80mm bore and connected with 25X4mm Copper strip upto test point (Gun metal) and connected from test point to appliances by 10 sqmm copper wire with PVC insulation complete with excavation earth work cast iron cover with back fill compound (Chemical for earth enhance gel--40Kg) . Complete all as specified and directed. Note: (i) Resistance Value should be less than 1 ohm. It shall be tested before considering for payment. (ii) 25X4mm Copper strip connecting upto test point and 10 sqmm copper wire with PVC insulation connecting from test point to appliances.
Supply and fixing double corrugated(DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930(part-I and II) for protection of UG cables size 50 sqmm and including aluminium XLPE UG cable size 35 Sqmm 3.5 Core outer dia with all fittings.laid in trenches/road/drain or fixed along wall,poles or laid under floor (incl. cutting floor/road and making good to match with existing adjoining surfaces etc for cable protection complete all as specified and directed by Engr-In-Charge. Make-REX/POLY/Gemine. Note :- (excavation and earth work shall be measured and paid separately under respective item of BOQ.)
Supply and fixing of DC Connection wire SPV to Invertor. by using 4sqmm Dual PVC TUV approved tined Copper used.Complete all as specified and directed by Engr-In-Charge. Make : Waacab/Havells/Polycab/KEI
Supply and fixing of TUV Certified MC4 connectors by using crimping kit with pins including all accessories Complete all as specified and directed by Engr-In-Charge.Make -Sibbas/Waree/SAPA and Wire Make -Waacab/KEI/Havells/Polycab
Supply and fixing of ESE Surge Lightning Protection Device for SPV protection connecting with copper wire 10sqmm with saddles upto earth test point with test Report min Area Covered 60mtr Radius around SPV with SS Steel Ground Mount by using Stay wire , stand Hot dip Galvanised height-10 Feet. maximum. Complete all as specified and directed by Engr-In-Charge. Make-SAPA/RB/Truepower/GSI
Supply and fixing of SLD Layout, String marking layout, safety Do's & Don'ts,Danger plate mount with GI Metal, fire safety cylinder near inverter, with complete supporting components,Design & Using SS fastners Complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (12.50mm aggraded aggregate ) as in coping or foundation work for securing solar panels legs with using WP solvent mixture make Dr. Fixit/Tectyl TM 506/Floorex/ MR Bond Polychem, foundation size 45x45x45 cm with proper making good the distrubed surface using exterior emulsion paint. Make: Nerolac/Asian paints/Nippron panits etc Complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2Ώ the earthing will be redone at no extra cost
Supply and laying, connecting and testing of XPLE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 95 sqmm 3.5 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc. Note : (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply and laying bricks, common burnt clay, sub class "B', old size, laid in vertical direction to cable as cable protection.Complete all as specified and as directe by Engr-In-Charge.
Supply and fixing of Retro reflective sign board print both side of size 600mm x 750mm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 5mm grouted in PCC 1:3:6 type C-1, 8000mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed. Note:- (i) Excavation, earth work, PCC, nuts, bolts, fasners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed by Engr-In-Charge.
All as per item No 19 here in before but exceeding 1.5 mtr and not exc. 3.0 mtr.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick compacted each layer. Complete all as specified and directed.
Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as directed by Engr-In-Charge.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc.
M&L for sand cushioning for cable with river washed sand with a layer of 8 cm before laying the cable and 15 cm deep after laying the cable. (Punned down to 18 cm after laying and streaching of cable). Complete all as specified and directed by Engr-In-Charge. Note: Punned thickness of sand layer shall be 18 cm and same will be considered for payment to contractor.
Material & labour for cement concrete in foundations, filling and mass concrete PCC as foundation to poles, type D2, 1:4:8 using 40 mm graded stone agregate as foundations to poles all as specified.
Material & labour for Cement concrete, filling and mass concrete, PCC type C2, 1:3:6 using 20 mm graded agregate as coping to poles all as specified.
Material & labour for cement concrete in foundations, filling and mass concrete PCC as foundation to poles, type B2, 1:2:4 using 40 mm graded stone agregate as foundations to poles all as specified.
Material and labour for steel tubular poles complete with cast iron base plate, finial taper plug, bolts,nuts & screws as specified type 410 SP -55 (11.0 meters long) conforming to IS- 1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 mtr above the coping of pole , starting with black strip complete all as specified and directed. Note : Excavation and earth work and PCC for foundation channel, clamps, nuts, bolts to be measured and paid separately.
M&L for Switch air break gang operated triple pole mechanically operated, vertical type 12 insulators and with galvanized steel frame, operated from ground level including operating rod, handle locking mechanism, current carrying capacity 200 amps, 11000 volts, fixed with nut, bolt and washers of required quantity, Complete all as specified and as directed.
Material and labour for lightning arrestor expulsion type 11000 Volt grade of capacity 65 KA including, connecting with HT line Complete all as specified & directed by Engr-In-Charge.
Supply, Laying and connecting XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 sq mm 3 core suitable for 11 KV earthed system, including taking down old cable of any size. Complete all as specified and directed by Engr-In-Charge. Note : (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 300 Sqmm 3 ½ core grade laid in trenches, floors, ducts passing through pipe for road crossing etc Complete all as directed by Engr-in-Charge. Note : (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 50 Sqmm 3 ½ core grade laid in trenches, floors, ducts passing through pipe for road crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 25 Sqmm 4 core grade laid in trenches, floors, ducts passing through pipe for road crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 10 Sqmm 4 core grade laid in trenches, floors, ducts passing through pipe for road crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 10 Sqmm 2 core grade laid in trenches, floors, ducts passing through pipe for road crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates Complete all as specified and directed by Engr-In-Charge.
Supply & fixing GI tubing light grade 80mm bore, on poles, under floors, road crossing etc all as reqd at site and as directed.
Supply & fixing GI tubing light grade 50mm bore, on poles, under floors, road crossing etc all as reqd at site and as directed.
Material & labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections of any size and shape including nut, bolts, washers, welding, bending, cold or hot drilling holes in bolts of any size including two coats of aluminium paint over one coat of primer including taking down old. Complete all as specified and as directed by Engr-In-Charge.
Material & labour for new earthing complete with galvanised earth plate electrode 60cmm x 60cmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 32x6 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
Dismantling and taking down old u/s earthing and Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
Note :- Sr Item No 43 to 46 (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves,link spreader provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved from Engr-in-Charge/GE before placing of order . (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed.
Supply and fixing of cable end jointing kit as in repair for 11 KV (Earthed) grade cable for outdoor end termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm.Complete all as specified and directed by Engr-In-Charge.
Supply and fixing of cable Straight through jointing kit as in repair for 11 KV (Earthed) grade cable for straight through, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed by Engr-In-Charge.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25x20 cm size. Complete all as specified and directed.
M&L for drilling hole of any size manually as per site requirement, drilling for laying pipes under the road for crossing electrical cable. Complete all as per direction of Engr-in-Charge.
Supply and fixing of Retro reflective sign board print both side of size 600mm x 750mm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 5mm grouted in PCC 1:3:6 type C-1, 8000mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed. Note:- (i) Excavation, earth work, PCC, nuts, bolts, fasners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
Cable jointing kit suitable as in repair for 1.1KV grade cable out door end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 300 Sqmm 3.5 core XLPE armoured aluminium conductor cable. Complete all as directed by Engr-In-Charge.
Cable jointing kit suitable for 1.1KV grade cable out door end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 50 to 95 Sqmm 3.5 core XLPE armoured aluminium conductor cable. Complete all as directed by Engr-In-Charge.
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole.Complete all as specified and as directed by Engr-in-Charge.
Supply,errection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type SP-31 (9 mtrs long) incl providing black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
Material & Labour as in repair for PVC insulated three core unsheathed multi stranded cable copper conductor wire 1100 volts grade of size 1.5 sq mm for lights and connecting with Busbar/Connector. Complete all as directed by Engineer -in-charge.
Supply & fixing in replacement of LED street light fitting 70 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street shall be measured and paid for separately.
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash. Complete all as specified and directed by Engr-In-Charge.
Material and labour for vibratory compactive, precast cement concrete rubber moulded, coloured (except grey colour), interlocking designer paver blocks in Milano shape, comfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, as in path, harding standing, etc laid over and including 25 mm compacted sand cushioning, including 75 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and removing excavated soil exc. 50 mtr but n. exc. 250 mtr. Complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed by Engr-In-Charge
S&F in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket for street light fitting all as specified and as directed by Engr-In-Charge.
Supply & fixing in replacement of Automatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Three phase, 20 Amps per phase, MCB rating 40 Amp, max load 5-8 kw incl circuit copper wire 10 sq.mm. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Model : Swadeep-02EC-5kW3P-VMS complete all as specified and directed. Note (i) Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years . (iii) The test certificate and warranty certificate must be provided by supplier.(iv) Cost of marking description on the box is incl quoted rate.
Supply only chain link fencing including line wires of 4 mm dia with 50x50 mm mesh size and type of strandard rails , straining bolts etc including provision of bending wire. Note : (i) weight of Barbed wire shall be measured by Engineer-in-Charge at site before in corporation in work and give due endorsement in MB.
Fixing only chain link fencing including line wires of 4 mm dia with 50x50 mm mesh size and type of strandard rails , straining bolts etc including provision of bending wire including taking down old. Complete all as specified and directed by Engr-in-Charge.
S&F as in repair Mild; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165. Complete all as specified and directed by Engr-In-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but lenth of bolt exc 5cm and n exc 10 cm long and diameter of neck 10mm Complete all as specified and directed by Engr-In-Charge.
S & F as in repair Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L two coats of synthetic enamel paints on new steel Surfaces exc 10cm girth over a coat of red oxide primer when unconnected with other painting or when painted in a different tint complete all as specified and directedby Engr-IN-Charge.
M&L two coats of synthetic enamel paints on steel Surfaces exc 10cm girth over a coat of red oxide Complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc. Complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as coping of pole and strut, stay around the pole etc. Complete all as specified and directed by Engr-In-Charge.
Material and labour for brick work with sub class 'B' (old size) bricks, straight or curved on plan, exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
Material & Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded mechanical crushed aggregate) for benching, coping, covering etc. complete all as specified & directed by Engineer-in-Charge.
M&L hardcore bocken stone boulder Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level Complete all as specified as directed by Engr-In-Charge.
M&L 100 mm thick PCC 1:2:4 type B1(20mm aggraded aggregate) finishing cement concrete surface even and smooth without using extra cement Complete all as specified as directed by Engr-In-Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing the surface fair and even smooth without using extra cement all as specified as directed by Engr-In-Charge.
M&L for preparation and applying three coats of white wash on new plastered surface of wall.
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc.15 cm thick, spread, levelled and rammed including watering.
Material and labour for hardcore broken stone or boulders filling of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-In-Charge.
S&F in replacement MCB TPN 4 pole 63 Amp, B type, 415 Volts, 50 Hz. Complete all as specified and directed by Engr-In-Charge.
Dismantling and taking down old unserviceable ACSR conductor incl cutting, complete all as per direction of Engr-In-Charge.
Supply & fixing in replacement of Integral LED Flood light Luminaries 100 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting, welding, drilling holes, nut bolts, washer complete all as directed by Engr-In-Charge.
Supply & fixing in replacement of LED street light fitting 20 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 6500K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engr-IN-Charge. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street shall be measured and paid for separately.
Surface excavation in soft/loose soil not exceeding 30cm deep and averaging 15 cm deep and getting out. Complete all as specified and as directed by the Engineer–in–Charge.
M&L for cement concrete 50mm thick (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection finished fair and even .Complete all as specified and directed by Engr-In-Charge.
M&L for damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 complete all as specified and as directed by the Engineer–in–Charge.
M&L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and as directed by the Engineer–in–Charge.
M&L for polythene film, 150 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15mm thick on other than fair faces of brick wall or concrete surfaces in cement mortar 1:4 finished fair and even without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces on brick wall or concrete surfaces in cement mortar 1:6 finished fair and even without using extra cement all as specified.
Supply only Integral water proofing compound complete.
M&L for preparation of newly plaster surfaces on wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plaster surfaces on wall and applying two coats cement based paint over a coat of alkali resistant primer complete all as specified.
M&L for 75 mm thick PCC Type D–2, 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed.
M&L for 40 mm thick PCC Type B–1, 1:2:4 (using 20mm graded crushed stone aggregate) as in sub base of floor before tiling. complete all as specified and as directed.
M&L for non–skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic tile in vertical surface such as skirting and dados size 450x300x7–8 mm thick on screed bed or bedding layer of mortar 10mm thick in CM 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and directed.
S&F for Pre–painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161–1979 grade St.–240 complete all as specified and directed.
S&F of 15mm size PVC connections with PTMP nuts of length 450mm complete all as specified and as directed by the Engineer–in–Charge.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer–in–Charge.
S&F 110mm bore PVC (SWR) bends of any radius, complete all as specified.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer–in–Charge.
S&F 75mm bore PVC (SWR) bends of any radius, complete all as specified.
S&F 75mm bore PVC (SWR) vent cowl, complete all as specified.
M&L for 15mm bore 'medium grade' GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer–in–Charge.
M&L for 20mm bore 'medium grade' GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer–in–Charge.
S&F 500 litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, connecting up pipes, securing access covers etc., and 20mm ball valve with float and flynut screwed to pipe including dismantling of water tanks and removing to store all as specified in SSR Part–I complete all as specified and as directed by the Engineer–in–Charge.
S&F 20mm bore gun–metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer–in–Charge.
M&L for PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer–in–Charge.
S&F 15mm bore stop valves /angle valve chromium plated fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair single piece vitreous china water closet (WC and flushing cistern) alongwtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern fittings 'S' or 'P' Trap complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair vitreous china table top /counter sunk wash hand basin white, of size 565mm x 420mm x 140mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling long screwed shank and fly nuts and 32 mm dia pvc corrugated waste pipe 900mm long including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S&F heatlh faucet mild steel chromium plated suitable for 15mm dia pipe with 1.20 metre long flexible tube and wall hook including making connections and fixed in position complete all as specified and as directed by the Engineer–in–Charge.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer–in–Charge.
S&F in repair soap dish, vitreous china white, approximate size 160x160x90mm fixed to plugs with chromium plated brass screws complete all as specified.
S&F toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F stainless steel 304 grade wall mounted towel rack with lower hanging towel hooks 600 mm long and 250mm wide between flanges including brackets complete all as specified.
S&F brass CP WHB /sink mixer swan neck for mixing hot & cold water for 15mm bore dia, pipes, screwed down for iron pipe and fixed complete all as specified and directed.
M&L for granite (of any type) tiles 16–18mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer–in–Charge.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B–1 smooth finished, and reforming benching as required for 100mm bore pipe line complete all as specified and as directed by the Engineer–in–Charge.
M&L for cement concrete bed 1:3:6, Type C–2 (using 40mm graded crushed stone aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested.
M&L for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by the Engineer–in–Charge.
M&L for precast cement concrete 1:2:4, Type B–1 (using 20 mm graded crushed stone aggregate) as in slab supported on walls, beams, chullah hood, chajja, column, culverts, manhole cover slabs similar type RCC works incuding demolition of existing RCC works complete all as specified.
S&F for powder coated (50mic min thickness) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
S&F for powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws and hinge 100mm long all complete as per architectural drawings and the directions of Engineer–in–Charge.
S&F 4.80mm thick frosted sheet glass ordinary type and glazing with aluminium beading, rubber packing or oil putty in square n exc 0.5 sqm each pane complete all as specified and directed.
S&F aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified.
S&F rubber strips 3 to 4 mm thick and 65 to 75 mm wide on bottom rail of door for covering gaps between door and floor to avoid entry of insects, dust etc and fixed with screws complete all as specified and as directed by the Engineer–in–Charge.
S&F in repair stainless steel tubing of 25 mm dia chromium plated min 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fancy type, stops fixed with ss screws etc complete fixed as in repair complete all as specified and as directed by the Engineer–in–Charge. Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered.
Dismantling of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc. complete all as specified.
Demolition of cement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and depositing the rubbish/ demolished material outside defence land, complete all as specified and directed.
Note:- Amount of credit of Rs 63760.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
bharat contrectors
Vandan Enterprises
SOLAR HUB COMPANY
R D Bansal
unique power & control system
JPMS BUILDTECH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .