Loading…
Loading…
Tender Value
₹23.6 L
EMD Value
₹47,235
Closing Date
3 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer
Executive Engineer Mechanical Division
Providing Installation and commissioning of High wall Split WindowCassetteFloor mounted Split type Air Conditioning system as and when urgently required in different areas AGMC GBP Hospital for 01 year period
2026_CEPWD_73955_1
40_EE__DNIeT_MECH.DIVN _2627
Open Tender
Electrical Works
365 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹47,235
19 Jun 2026
19 Jun 2026
3 Jul 2026
19 Jun 2026
3 Jul 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. | ||||||
| 1.01 | 1.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 3000 Kcal/hr or 12000 BThu/hr or 3500 watt). | 1 | No | - | - | Item09 |
| 1.02 | 1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt). | 5 | Nos | - | - | Item18 |
| 1.03 | 2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt). | 18 | Nos | - | - | Item19 |
| 1.04 | 1.5 TR window/ type AC machine (Minimum rated cooling capacity should not be lsss than 4500cal/hr or 18000 Thu/hr or 5250 watt) | 2 | Nos | - | - | Item19 |
| 2Providing 3 star rated (Minimum 3 star with applicabls ISEER accordlng to current industry standard) Ceiling mounted Cassette/ Floor mounted vertical Split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption suitable for operation on 420 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. | ||||||
| 2.01 | 3.0 TR Cassette type AC machine (Minimum rated cooling capacity should not be lsss than 9000 Kcl/hr ) or 36000 BThu/h or 10500 watt). | 1 | No | - | - | Item19 |
| 2.02 | 3.65 TR floor mounted vertical Split type AC machine (Minimum rated cooling capacity should not be lsss than 10950 Kcl/hr ) or 43800 BThu/h or 12775 watt). | 5 | Nos | - | - | Item19 |
| 3 | Standard installation, testing and commissioning of 1.0/1.5 / 2.0 TR high wall split type / window AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 26 | No | - | - | Item19 |
| 4 | Standard installation, testing and commissioning of 3.0 TR ceiling mounted cassette type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 1 | No | - | - | Item19 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
DNIT.pdf
Tender Documents • 3.11 MB
BOQ_75266.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid