Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.4 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | ₹20.4 L | L-1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L-2₹21.0 L+₹61,655 (3.03%)Rejected-Finance | ₹21.0 L+₹61,655 (3.03%) | L-2 | Rejected-Finance Over all rates are higher than L-1. |
| 3 | L-3₹23.0 L+₹2.6 L (13.0%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | ₹23.0 L+₹2.6 L (13.0%) | L-3 | Rejected-Finance Over all rates are higher than L-1. |
| 4 | L-4₹23.7 L+₹3.3 L (16.2%)Rejected-Finance | ₹23.7 L+₹3.3 L (16.2%) | L-4 | Rejected-Finance Over all rates are higher than L-1. |
| 5 | Rejected-Technical | - | - | Rejected-Technical NO in WLR of CEBZ Dec 19. |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
2 Jun 2020, 6:00 pmClosed
Garrison Engineer, Air Force, Izatnagar, Bareilly
Garrison Engineer, Air Force, Izatnagar, Bareilly, 243002
CREATION OF INFRASTRUCTURE FACILITIES FOR LIZARD 2 LGK AND RENEWAL / REPLACEMENT OF BER CEILING FANS, EXHAUST FANS AND CABIN FANS AT AF STATION IZATNAGAR, BAREILLY.
2020_MES_329304_1
8511 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Izatnagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹48,000
Yes
16 Jul 2020
27 Feb 2020
4 Jun 2020
27 Feb 2020
2 Jun 2020
15 Mar 2020
27 Feb 2020 - 15 Mar 2020
Amount
M & L for point wiring in colour coding Red, Black and Green (RBG) for one light point / fan point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 1.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the independent board complete all as specified and directed.
All as per item No. 1.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 1.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F of lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
Supply and fixing of 5.00 KVA capacity servo controlled voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type, unbalanced type, copper wound, metallic body duly powder coated with lifting hooks, two Nos., with digital display type, relay free (Microprocessor based) smooth and silent operation with and including first filling of transformer oil upto level complete all as specified and directed comprising the following provisions and specifications: - (a) Incomer- MCB TPN of appropriate capacity. (b) Input voltage range- 300 to 460 Volts. (c) Output voltage stabilized at- 415 Volts + 1%, 3 Phase, 50 Hz. (d) Operating frequency- 47 to 53 Hz. (e) Operating Temprature- 0 to 50 Degree Centigrade. (f) No. of Phases- 03. (g) Speed of correction- 8 to 6 Volts per Second for single phase and 13 volts for Phase to Phase. (h) Efficiency- Greater than 97%. (j) Type of voltage / load- Unbalanced 4 wire. (k) Mode of Operation- Fully automatic. (l) Displaying type- Digital Voltmeter, Digital Ammeter, Digital Input frequency meter. (m) Accuracy- + 2.5%, having speed of correction 8 Volts per second. (n) Protective- Over voltage, under voltage, over load, High / low voltage cut off, single phase preventor and phase reversal protection with by pass arrangement switch 4 Pole of suitable capacity, spike suppressor, alarm system. MAKE- Steady Volt of Volt Amp, Brent Ford, AE, Sen & Pandit, Kolkata, Winitech, Servo star.
Supply and fixing of 5.00 KVA capacity UPS suitable for minimum 30 minutes back up, single phase, designed for input voltage of 160 to 260 Volts and output voltage at 230 Volts with accuracy of + 1% comprising of the following provisions and specifications complete all as specified and directed: - (a) Type- Single phase, IGBT based, Online UPS. (b) Input- 240 Volts ±10%, AC, 50 ±5% Hz, Single phase, three wire (Phase+Neutral+Ground) (c) Output- 5 KVA, 230 Volts ±10%, AC, 50 ±5% Hz, Single phase, Three wire (Phase+Neutral+Ground) (d) Output Waveform- Sinusoidal (e) Voltage Regulation- ≤ ± 2% (f) Inverter Efficiency- ≥ 80% (g) Overload Capability- 110% for ≥10 Minutes. (h) Total Harmonic distortion (THDI)- <5% at Full load. (j) Transient response- Less than ±10% voltage variation at sudden application / removal of full load and it shall recover within 500 msec. (k) Environment- Approx. 0-50°C and 95% RH. (l) Charger- Charging mode shall be provided. (m) Battery Charging Voltage and Current shall be adjustable. (n) Line and load Regulation- ≤ ±2% (o) Output Ripple- ≤ 3% (p) Battery- Battery shall be of Sealed Maintenance Free (SMF) or VRLA type, Battery Backup shall not be less than 1 Hour at full load. (q) Capacity of Batteries- 18 Ah, 12 Volts- 20 Nos. MAKE- Microtek, APC, Exide, SU-KAM Power. NOTE- Make of UPS and Batteries shall be same.
S & F of wall / surface mounted type LED light fitting batten type complete with and including LED lamp 1 X 20 watt (4 feet long), extruded aluminium heat sink provide for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including making electric connection with flexible twin core 1.00 sqmm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed. Make- Philips Cat. Part No. BN021C LED20S PSU CW GRS2 (Smart Bright) of Philips or ENDURALINEARNEOBS20WLED830SPCWH (ENDURA LINEAR NEO) of Havells
S & F of retrofit type LED lamp 12 watt capacity complete all as specified and directed. Make- Philips or Havells.
Supply and fixing of 1200 mm sweep 240 volts, AC having BEE 5 star rating ISI marked, off white coloured ceiling fan as per model Orient Quasar (Premium Series) or Usha Striker Galaxy or Havells Fusion complete with fan blade, capacitor, canopy, down rod etc. with and including making electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of ceiling fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high complete all as specified and directed.
S & F of electronic type fan regulator 230 volts, step type having five steps, switch type, hum free complete all as specified and directed.
S & F of 1100 volts grade heavy duty two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring in colour coding Red, Black and Green (RBG), drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed for the following: -
(a) 2 X 2.50 Sqmm as main wires + 1 X 1.50 sqmm as earth wire.
(b) 2 X 4.00 sqmm as main wires + 1 X 2.50 sqmm as earth wire.
S & F of 1100 volts grade heavy duty two single core 6.00 Sqmm size PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring in colour coding Red, Black and Green (RBG), drawn into & including PVC Casing-N-Caping medium grade not less than 25 mm size with and including its all accessories & fittings, fixed on surface and making good the same as per existing specifications along with a continuous run of multi-stranded copper conductor 4.00 Sqmm size PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed.
S & F of flush mounting factory made Ekinoxe TPN DB's Double door, 4 way (Cat. Part No. 607715 of Legrand or Cat. Part No. CSDBTPNHDD08 of C&S or having same specifications in L&T), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed.
S & F of flush mounting factory made Ekinoxe SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed.
S & F of MCB triple pole and neutral, 415 volts, 63 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed.
S & F of MCB single pole and neutral, 240 volts, 32 to 40 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed.
S & F of MCB single pole 240 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series complete all as specified and directed.
S & F of RCCB, 63 Ampere, 300 mA, 4 pole, earth leakage protection complete all as specified and directed. (Cat. Part No. 411893 of Legrand or having same specifications in L&T or C&S).
S & F of 63 Ampere capacity emergency push button complete in all respects with and including all necessary connections and wiring as a single unit suitable for 3 Phase, 415 Volts, 50 Hz, AC supply complete all as specified and directed. MAKE- Schneider, Siemens, L&T
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 25 Sqmm 4 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
S & F of MCCBs, 63 Ampere, 50 Hz, 415 volts, 4 pole, 25 KA, thermal magnetic all as specified and directed. (Cat. Part No. 420043 of Legrand or having same specifications in L&T or C&S).
M & L for Chemical Earthing with copper grounding earth rod of length not less than 3.00 metre, dia 17.20 mm molecularly bonded with 250 micron copper, burried directly in ground, earth pit not less than 3.20 metres below normal ground level and size of pit hole shall be of 125 mm dia, with top edge of the earth rod not less than 0.75 metres below normal ground level, earth rod surrounded by at least 30 Kg of ground enhancing material i.e. 25 Kg of Earthcon and 5 Kg Tarac compound to reduce soil resistivity, upto 2.80 metres height and including connected to copper strip 32 X 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 40 mm bore light grade pipe from electrode and upto and including the earth test point of galvanised iron / steel of size 75 x 75 x 25 mm test point 15 mm bore watering pipe light grade GI funnel, wire mesh including necessary earthwork and excavation, removal of surplus soil to a distance not exc. 50 m, PCC pit in PCC (1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. MAKE: - Truepower Earthings, Sabo systems Pvt Ltd, Jaipuria Brothers, Inter Tech India Ltd. NOTE:- Additional earthing compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and fixing of test point terminal block made of gun metal or phasphorous bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screw fixed to wall and connected with earth strip complete all as specified and directed.
S & F of 20 X 3.15 mm size copper strip as in earth continuity conductor or main earthing lead burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed.
S & F of 40 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable laid in trenches or fixed to pole or other vertical surface or for insertion in horizontal boring complete all as specified and directed.
S & F of 80 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable laid in trenches or fixed to pole or other vertical surface or for insertion in horizontal boring complete all as specified and directed.
M & L for making horizontal hole by mechanical Boring under hard standing, pavements or roads for insertion of GI pipes 40 to 80 mm bore and making good the disturbed surface complete all as specified and as directed.
Supply, installation, commissioning and testing of 1.50 TR capacity hi wall, copper wounded, BEE 5 star rating, inverter type (DC inverter type) (hot and cool type) R-410A, CFC free split AC with indoor and outdoor units and cordless remote control unit complete all as specified and directed. NOTE: - Power cable between indoor and outdoor unit shall be deemed to be included in quoted rates. Copper piping and drain pipe shall be measured and paid seperately under respective items of this schedule.
Supply and fixing of 5 KVA capacity copper wounded voltage stabilizer for automatic operation, single phase, floor mounted, naturally air cooled, indoor type designed for input voltage of 90 to 250 Volt with stabilized output voltage at 230 Volts with accuracy of + 2.5% complete all as specified and directed.
S & F of copper tubing pair of two pipe for suction and discharge, size of suction pipe 1/2" and discharge pipe 1/4" diameter, 0.8 mm wall thick complete with separate nythyle vinil insulation 9 mm thick including chase cutting wall and making good of existing surface as required on site complete all as specified and directed.
Supply and fixing of wall / floor mounting type powder coated stand suitable for mounting of out door unit of Split AC as per manufactur's recommendations complete all as specified and directed.
S & F of 25 mm dia unplasticised PVC pipes of appropriate pressure rating, fixed to walls, ceilings or laid in floors including chase cutting on wall and making good as per existing complete all as specified and directed.
S & F of single pointed air termination copper rod, 12 mm dia and 300 mm long including 20 mm size air terminal base / ridge saddle made of gun metal with and including fixing arrangment on the ridge of RCC roof / on pole as required complete all as specified and directed.
S & F of 20 mm nominal bore GI tubing, light grade with all fittings including fixing arrangement with screws, clamps on insulator for protection of air termination rod complete all as specified and directed.
M & L for Chemical Earthing with copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground, earth pit not less than 5.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 32 x 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 40 mm bore light grade pipe from electrode and upto and including the earth test point of galvanised iron / steel of size 75 x 75 x 25 mm test point 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt (40 Kg), charcoal dust (40 Kg) and Magnisium sulphate (50 Kg) filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, PCC pit in PCC (1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. MAKE: - Truepower Earthings, Sabo systems Pvt Ltd, Jaipuria Brothers, Inter Tech India Ltd. NOTE:- Additional Chemical compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
M & L for providing pre-cast cement concrete block any size as per site requirement as in support block of GI pipe and air terminal rod and the like in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate complete all as specified and directed.
Supply and fixing of 1400 mm sweep 240 volts, AC having BEE 5 star rating ISI marked, off white coloured ceiling fan as per model Orient Quasar (Premium Series) or Usha Striker Galaxy or Havells Fusion complete with fan blade, capacitor, canopy, down rod etc. with and including making electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of ceiling fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old ceiling fan any type and depositing the same in MES store complete all as specified and directed.
Supply and fixing of 1200 mm sweep 240 volts, AC having BEE 5 star rating ISI marked, off white coloured ceiling fan as per model Orient Quasar (Premium Series) or Usha Striker Galaxy or Havells Fusion complete with fan blade, capacitor, canopy, down rod etc. with and including making electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of ceiling fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old ceiling fan any type and depositing the same in MES store complete all as specified and directed.
Supply and fixing of 300 mm sweep heavy duty metal body exhaust fan Make- Orient or Usha or Havells, 3 Star rating, single phase 230 volts AC, 900 RPM complete with and including all accessories, louver shutter at the existing place of old exhaust fan, grouting of ragged bolts in wall as required for fixing of exhaust fan, frame, louvers and making new electric connection with three single core flexible copper conductor cable of size 2.50 Sqmm from ceiling rose to connector of exhaust fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old exhaust fan any type and depositing the same in MES store complete all as specified and directed.
Supply and fixing of 450 mm sweep heavy duty metal body exhaust fanMake- Orient or Usha or Havells, 3 Star rating, single phase 230 volts AC, 900 RPM complete with and including all accessories, louver shutter at the existing place of old exhaust fan, grouting of ragged bolts in wall as required for fixing of exhaust fan, frame, louvers and making new electric connection with three single core flexible copper conductor cable of size 2.50 Sqmm from ceiling rose to connector of exhaust fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old exhaust fan any type and depositing the same in MES store complete all as specified and directed.
Supply and fixing of 400 mm sweep, wall mounted cabin fan Make- Orient or Usha or Havells, 1350 RPM, 5 star rating, single phase, 230 volts AC, 50 Hz, single phase metalic body (Heavy Duty) complete with pull cord control for speed and oscilleting mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076 with and including taking down old cabin fan any type and depositing the same in MES store complete all as specified and directed.
M/s Agarwal Builders
M/s KUMAR CONSTRUCTION CO.
VINYAK TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .