Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 CrAccepted-AOC B 1703 MODERN INDUSTRIAL ESTATE BAHADURGARH HARYANA 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | ₹8.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹8.7 Cr+₹70.1 L (8.75%)Rejected-Finance PLOT NO F AND G RAKBA DARAKHERA PROFESSOR COLONY NAGAR PARISAD THANESAR KURUKSHETRA HARYANA 136 118 | ₹8.7 Cr+₹70.1 L (8.75%) | L2 | Rejected-Finance Highest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non responsive |
Tender Value
₹8.2 Cr
EMD Value
₹16.3 L
Closing Date
16 Aug 2023, 10:00 amClosed
NAVEEN RATHEE
Electrical Division PWD Band R Ambala Cantt
Construction of MCH Block and Service Block in the campus of Civil Hospital, Sec.-6, Panchkula. (Pdg. Central Air Conditioning System)
2023_HRY_260220_2
20238ADA6539 F929 43E2 8231 B3BB4F363505663BAR
Open Tender
Electrical Works
Works
500 days
Ambala Cantt
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
₹16.3 L
Yes
Ambala Cantt
20 Nov 2023
27 Jul 2023
16 Aug 2023
27 Jul 2023
16 Aug 2023
27 Jul 2023
10 Aug 2023
Amount
[23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm
[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm
[23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
Chilled water Pump: Supply, Installation, Testing of Centrifugal vertical split casing chiller water circulating end suction and top discharge type pump sets complete with coupling, TEFC motor, base plate, priming funnerl, air vent, air cock etc. as per specifications. i) Min. pump efficiency at duty conditions shall be 75% ii) Flow Rate : 1080 USGPM iii) Head : 32 Metre WC (2W plus 1S)
CONDENSER WATER PUMP:- Supply, Installation, Testing of Centrifugal vertical split casing chiller water circulating end suction and top discharge type pump sets complete with coupling, TEFC motor, base plate, priming funnel, air vent, air cock etc. as per specifications. i) Min. pump efficiency at duty conditions shall be 75% ii) Pump Flow Rate : 1800 USGPM iii) Head : 28 Metre WC (2W plus 1S)
Electric Hot Water Generator:- Supply, Installation, Testing of 500 KW Electric Hot Water Generator (1W plus 1S) with multiple steps complete with accessories, fittings, etc complete the job in all respect up to the entire satisfaction of the Engineer in charge of work.
High Static Air handling Units(Floor Mounted/ Ceiling Suspended) Providing and fixing of Double skin inner sheet of Aluminium, high static draw through type, Single Tier Air Handling Units complete with fan section with fan and motor, coil section with cooling coil, flat filter section with standard filter, filter section with micro v filters(5 microns) wherever specified, dampers, fresh air damper, mixing box, drive set, belt guard, flexible cavass connections, inclined manometer across micro v filters and accessories as per specifications and drawings of following capacities, including 3 way modulating valve along with actuator and thermostat for chilled water flow control and with coil mounted UVGI system complete in all respects as per site requirements with thermal break profile. i) 16500 CFM with 6 Row coil with 65 mm static pressure ( FM) with fine filter
High Static Air handling Units(Floor Mounted/ Ceiling Suspended) Providing and fixing of Double skin inner sheet of Aluminium, high static draw through type, Single Tier Air Handling Units complete with fan section with fan and motor, coil section with cooling coil, flat filter section with standard filter, filter section with micro v filters(5 microns) wherever specified, dampers, fresh air damper, mixing box, drive set, belt guard, flexible cavass connections, inclined manometer across micro v filters and accessories as per specifications and drawings of following capacities, including 3 way modulating valve along with actuator and thermostat for chilled water flow control and with coil mounted UVGI system complete in all respects as per site requirements with thermal break profile. i) 14500 CFM with 6 Row coil with 65 mm static pressure (FM) with fine filter
High Static Air handling Units(Floor Mounted/ Ceiling Suspended) : Providing and fixing of Double skin inner sheet of Aluminium, high static draw through type, Single Tier Air Handling Units complete with fan section with fan and motor, coil section with cooling coil, flat filter section with standard filter, filter section with micro v filters(5 microns) wherever specified, dampers, fresh air damper, mixing box, drive set, belt guard, flexible cavass connections, inclined manometer across micro v filters and accessories as per specifications and drawings of following capacities, including 3 way modulating valve along with actuator and thermostat for chilled water flow control and with coil mounted UVGI system complete in all respects as per site requirements with thermal break profile. i) 10000 CFM with 6 Row coil with 65 mm static pressure (FM) with fine filter
High Static Air handling Units(Floor Mounted/ Ceiling Suspended) : Providing and fixing of Double skin inner sheet of Aluminium, high static draw through type, Single Tier Air Handling Units complete with fan section with fan and motor, coil section with cooling coil, flat filter section with standard filter, filter section with micro v filters(5 microns) wherever specified, dampers, fresh air damper, mixing box, drive set, belt guard, flexible cavass connections, inclined manometer across micro v filters and accessories as per specifications and drawings of following capacities, including 3 way modulating valve along with actuator and thermostat for chilled water flow control and with coil mounted UVGI system complete in all respects as per site requirements with thermal break profile. i) 7000 CFM with 6 Row coil with 125 mm static pressure(CS) with fine filter
High Static Air handling Units(Floor Mounted/ Ceiling Suspended) : Providing and fixing of Double skin inner sheet of Aluminium, high static draw through type, Single Tier Air Handling Units complete with fan section with fan and motor, coil section with cooling coil, flat filter section with standard filter, filter section with micro v filters(5 microns) wherever specified, dampers, fresh air damper, mixing box, drive set, belt guard, flexible cavass connections, inclined manometer across micro v filters and accessories as per specifications and drawings of following capacities, including 3 way modulating valve along with actuator and thermostat for chilled water flow control and with coil mounted UVGI system complete in all respects as per site requirements with thermal break profile. i) 3000 CFM with 6 Row coil with 125 mm static pressure(CS) with fine filter
Fan Coil Unit: Supply, Installation, Testing of 4.0 Tr. Ceiling concealed horizontal Fan Coil Unit including wall package consisting of ball valve with/without stainer and including 3 way modulating valve along with actuator and thermostat etc. for chilled water flow control and with coil mounted UVGI system complete in all respect upto the entire satisfaction of Engineer in Charge of work.
Fan Coil Unit: Supply, Installation, Testing of 2.5 Tr. Ceiling concealed horizontal Fan Coil Unit including wall package consisting of ball valve with/without stainer and including 3 way modulating valve along with actuator and thermostat etc. for chilled water flow control and with coil mounted UVGI system complete in all respect upto the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 300 MM NB Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 250 MM NB Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 200 MM NB Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 150 MM NB Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 125 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 100 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 80 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 65 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 50 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 40 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 32 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 25 MM Mild Steel Chilled Water piping of class “C”, ISI marked with all necessary fittings i.e. supports, bends, tees, reducers, flanges, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 200 MM Butterfly Valves for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 125 MM Butterfly Valves for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 80 MM Butterfly Valves for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 65 MM Butterfly Valves for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 50 MM Butterfly Valves for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 200 MM Balancing valves with counter flanges, gasket, nuts, bolts, insulation, supports etc. for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 125 MM Balancing valves with counter flanges, gasket, nuts, bolts, insulation, supports etc. for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 80 MM Balancing valves with counter flanges, gasket, nuts, bolts, insulation, supports etc. for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 65 MM Balancing valves with counter flanges, gasket, nuts, bolts, insulation, supports etc. for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 50 MM Balancing valves with counter flanges, gasket, nuts, bolts, insulation, supports etc. for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 200MM Non-Return Valves conforming to ISI, or equivalent with flanges, nut, bolts, gasket, support etc. for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 200 MM Y-Strainers (Bronze Screen removable type) for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Pressure Gauges PN 16 with Adaptor and gauge cock for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Digital Thermometer with thermowell for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Water Flow switch for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Automatic Air Vent for chilled water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 300 MM NB chilled water pipe insulation with fire retardant 50 /25 mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 250 MM chilled water pipe insulation with fire retardant 50 /25 mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 200 MM (50 mm thick insulation) chilled water pipe insulation with fire retardant 50mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 150 MM (50 mm thick insulation) chilled water pipe insulation with fire retardant 50mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 125 MM (50 mm thick insulation) chilled water pipe insulation with fire retardant 50mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 100 MM (50 mm thick insulation) chilled water pipe insulation with fire retardant 50mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 80 MM (50 mm thick insulation) chilled water pipe insulation with fire retardant 50mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 65 MM (25 mm thick insulation) chilled water pipe insulation with fire retardant 25mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 50 MM (25 mm thick insulation) chilled water pipe insulation with fire retardant 25mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 40 MM (25 mm thick insulation) chilled water pipe insulation with fire retardant 25mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 32 MM (25 mm thick insulation) chilled water pipe insulation with fire retardant 25mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 25 MM (25 mm thick insulation) chilled water pipe insulation with fire retardant 25mm thick TF Quality PUF / Class O Nitrile rubber cladded with 26 Gauge thick aluminium sheet to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply, installation, testing and commissioning of 400 MM Mild Steel Condenser Water piping of class “C”, ISI marked with all necessary fittings i.e. bends, tees, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 250 MM NB Mild Steel Condenser Water piping of class “C”, ISI marked with all necessary fittings i.e. bends, tees, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 125 MM NB Mild Steel Condenser Water piping of class “C”, ISI marked with all necessary fittings i.e. bends, tees, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of 100 MM NB Mild Steel Condenser Water piping of class “C”, ISI marked with all necessary fittings i.e. bends, tees, supports etc. to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 250 MM Butterfly Valves for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 125 MM Butterfly Valves for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 250 MM Balancing valves with counter flanges, gasket, nuts, bolts, insulation, supports etc. for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and erection of 250 MM Non-Return Valves conforming to ISI, or equivalent with flanges, nut, bolts, gasket, support etc. for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of 250 MM Y-Strainers (Bronze Screen removable type) for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Pressure Gauges PN 16 with Adaptor and gauge cock for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Digital Thermometer with thermowell for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Water Flow switch for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and erection of Automatic Air Vent for condenser water pipe to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and Erection of 40 MM G.I. drain piping of ‘B’ class or equivalent rigid PVC heavy duty complete with fittings, supports, valves and 6 mm thick closed cell elastomeric insulation as per specification to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and Erection of 32 MM G.I. drain piping of ‘B’ class or equivalent rigid PVC heavy duty complete with fittings, supports, valves and 6 mm thick closed cell elastomeric insulation as per specification to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and installation of 24G (GI Thickness) factory/site fabricated GI Ducting (Rectangular) with supports, dampers, vanes, nuts, bolts etc. as per ISI specifications to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and installation of 22G (GI Thickness) factory/site fabricated GI Ducting (Rectangular) with supports, dampers, vanes, nuts, bolts etc. as per ISI specifications to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and installation of 20G (GI Thickness) factory/site fabricated GI Ducting (Rectangular) with supports, dampers, vanes, nuts, bolts etc. as per ISI specifications to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and installation of 0.80 MM (20G/ 18G) factory/site fabricated Aluminium Sheet Metal Ducting with supports, dampers, vanes, nuts, bolts etc. as per ISI specifications to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Providing and fixing of 25 MM thick thermal insulation with `O` class nitrile rubber on ducts as per specification to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Providing and fixing of 19 MM thick thermal insulation with `O` class nitrile rubber on ducts as per specification to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of Extruded Aluminium grilles duly powder coated to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of Aluminium supply air grilles / Diffuser with damper to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of Aluminium return air grilles without damper to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Providing and fixing of Galvanised sheet fire dampers to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Providing and fixing of Smoke Sensors, Actuators for fire dampers and associated control wiring to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, Installation, Testing and Commissioning of Extruded aluminium exhaust air / fresh air louvres with frame, GI bird screen, pre-filter with frame, mounting arrangement etc. as per specifications and drawing to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, Installation, Testing and Commissioning of Vane Axial Flow Fans with suitable motor and drive assembly, with all accessories and fire rated flexible connections, mounting frame hangers etc. Motor shall be suitable for 415 V plus /- 10%, 3 phase, 4 wire, 50 plus /- 3% Hzs, electric supply. Fans shall be AMCA certified. The fan and motor should be fire rated for 90 minutes to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. The specifications of Vane Axial Flow Fan is as under:- Capacity. : 5900 CFM Static pressure: 25 mm Wg Fan speed: 1450 RPM Fan Motor: 3.0 HP Fan Dia: 600mm approx Noise Level: max. 75 db at 3.0 m from fan
Supply, Installation, Testing and Commissioning of Vane Axial Flow Fans with suitable motor and drive assembly, with all accessories and fire rated flexible connections, mounting frame hangers etc. Motor shall be suitable for 415 V plus /- 10%, 3 phase, 4 wire, 50 plus /- 3% Hzs, electric supply. Fans shall be AMCA certified. The fan and motor should be fire rated for 90 minutes to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. The specifications of Vane Axial Flow Fan is as under:- Capacity. : 11700 CFM Static pressure: 25 mm Wg Fan speed: 1450 RPM Fan Motor: 5.0 HP Fan dia: 800mm aprox. Noise Level: max. 75 db at 3.0 m from fan Fan Duty: fresh air supply
Supply, installation, testing and commissioning of wall-mounted sub panel boards for AHUs, Blower with switch, starters, lamps interconnections, current operated single phase preventer, A/M switch etc. as per specifications and drawings and as required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. For 18000-12000 CFM ( 11 Kw) OUTGOING : 1 No. MPCB with a suitable rating 1 No. Contactor as suitable 1 No. single phase preventer 1 No. ammeter with ASS and CT 2 Nos indicating lights 2 Nos. Push buttons
Supply, installation, testing and commissioning of wall-mounted sub panel boards for AHUs, Blower with switch, starters, lamps interconnections, current operated single phase preventer, A/M switch etc. as per specifications and drawings and as required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. For 11000-8200 CFM ( 7.5 Kw) OUTGOING : 1 No. MPCB with a suitable rating 1 No. Contactor as suitable 1 No. single phase preventer 1 No. ammeter with ASS and CT 2 Nos indicating lights 2 Nos. Push buttons
Supply, installation, testing and commissioning of 63 Amps TP Isolator outdoor weatherproof switch box of continuous welded construction, fabricated out of 1.6/2 mm thick G.I. sheet complete with water tight gasket with front openable and lockable door including earthing, painting, glands, danger boards etc. suitable for mounting on wall with M.S. angle iron frame of size 40x40x6 mm consisting of relevant I.S. specifications and drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Note : Isolator make LandT/Siemens/Schnieder
Suuplying, Installation, Testing and Commissioning of floor-mounted desk type Control Console in A/c plant room containing various indications and controls for the A.C. system comprising of 2 Nos. chilling machine, 4 Nos. pumps, 2 Nos. cooling tower, 15 Nos AHU/CSU with test push buttons facility. The panel shall be fabricated from minimum 1.633 thick M.S. Powder coated sheet of approved design. The A.C. module of the Central Control shall have the following accessories: Status indication (ON, OFF) for each compressor for each chilling machine and all pumps. Push Buttons and Indication lamps for remote start and stop and status indication for each of the AHUs. Push Buttons and Indication lamps for remote start and stop and status indication(ON, OFF and Fault) for each of the 3 Nos. Cooling Tower motors and low level indication for each of 3Nos. cooling tower. Hooter and Flashing lamps to indicate operation of any safety/shut down with necessary contractors, accept, reset and test push buttons complete as per specifications to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, Installation, Testing of 600 TR capacity (2W plus 1S) FRP vertical induced draft counter flow type cooling towers each complete with FRP basin, FRP body, fan and Motor reduce gear assembly, fill media, distribution basin pipe connections, Ladder etc. as per specifications and drawings (Double Fan), including Civil Foundation Work (including of VFD) to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Providing and fixing of pressurized Expansion Tank of 1000 Ltr. capacity duly insulated with 50mm thick insulation and as per specifications and drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated Copper armoured cable of size 1.5 Sqmm x 2 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and Erection of PVC insulated Copper armoured cable of size 2.5 Sqmm x 6 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work
Supply and Erection of PVC insulated aluminium armoured cable of size 50 Sqmm x 3.5 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated aluminium armoured cable of size 16 Sqmm x 4 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated aluminium armoured cable of size 10 Sqmm x 4 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated aluminium armoured cable of size 6 Sqmm x 3 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated aluminium armoured cable of size 4 Sqmm x 3 Core 1100 Volts grade as per drawings to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, installation, testing and commissioning of inline exhaust fan of capacity 700 CFM - 20 MM single phase motor of approved make and specifications. Fan shall be supplied with aluminium gravity louver, bird screen and 3-speed fan regulator including UL listed ozone generator with interlocking wiring to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated aluminium armoured cable of size 240 Sq. mm 3.5 Core Cable 1100 Volts grade to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
S/I/T/C of Duct acoustic lining 25 MM thick with glass wool insulation covered with 0.5 mm perforated aluminium sheet, nuts, bolts etc. complete as per specifications and drawings to complete the job in all respect.
S/I/T/C/ of self Balancing valves for FCUs of 20/25mm NB to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.
Minor Civil work for making holes and foundation etc. with all petty material and labour required to complete the job in all respect upto the entinre satisfaction of Engineer in Charge of work
Providing and fixing of 8 SWG dia copper wire for loop earthing with all petty material and labour required to complete the job in all respect upto the entinre satisfaction of Engineer in Charge of work
Supply, installation, testing Water Cooled Centrifugal Chilling M/c of 450 TR (Actual) capacity with VFD and harmonics filters at below mentioned operating conditions with Eco friendly non-poisioness / R-134a refrigerant, semi-hermetic/hermatic type compressors provided with unit mounted /Free standing starter driven by suitable KW Sq. cage induction motor complete with water cooled shell and tube type condenser, 19mm thick insulated shell and tube chiller, refrigerant piping, Refrigerant and Oil (First Charge ), Microprocessor based control panel and accessories etc. as per specifications, all mounted on M.S. frame complete factory fitted in all respect . Totally Enclosed Motor shall be suitable for 415 volts plus 10%, 50 Hz , three phase A.C. supply AHRI / EUROVENT certified with Factory fitted Air Cooled IP 54 VFD and IP 54 harmonic filters limiting THDI- 5%, THDV -5%. Including power and control cabling between starter and Chiller: cost of witness testing of chiller at 4 points at reducing condenser water temperature as per AHRI. Performance is to be winessed by the two Engineers of Department at vender/contractor`s cost. The Chilling Machine shall be inline with specifications having maximum IKW/TR upto 0.63 (at design conditions) and min. COP 6.4 and NPLV-0.36 at AHRI conditions. NPLV-0.37 COP-6.4 The Vendor shall submit ARI computational sheet duly stamped Chiller Water IN - 54 °F Chilled Water OUT - 44 °F Chilled water Flow - 1080 USGPM Fouling Factor - 0.0005 FPS Pressure drop across cooler not more than 5 Meter Condenser Condenser Water IN - 90°F Condenser Water OUT - 97.5°F Condenser Water Flow - 1800 USGPM Pressure drop across cooler not more than 5 Meter Fouling Factor - 0.001 FPS (2W plus 1S)
SKG INFRATECH PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .