Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹14.5 L+₹54,747.50 (3.92%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L3₹14.8 L+₹83,255 (5.97%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN L1 | |
| 4 | L4₹15.8 L+₹1.9 L (13.4%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN L1 | |
| 5 | L5₹17.8 L+₹3.9 L (27.8%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹18.2 L
EMD Value
₹36,400
Closing Date
27 Jun 2022, 6:00 pmClosed
CWE YOL
HQ CWE Yol, Pin-901260
REPAIR/ REPLACEMENT OF EXISTING UNSERVICABLE LT POLE, UG CABLE AND OTHER CONNECTED WORKS AT MIL STN DHARAMSALA
2022_MES_527387_1
CWE/Y-24/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
dharamshala
As per tender documents
9 documents required · 9 mandatory
₹500
AGE I Dharamshala
₹36,400
Yes
9 Sept 2022
30 May 2022
29 Jun 2022
30 May 2022
27 Jun 2022
15 Jun 2022
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed.
All as per Srl Item No 1.00 above but depth exceeding 1.5 mtr and not exceeding 3.0 mtr.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
SMC cable junction box of size 140x140x95mm suitable for street light/PTL, square type , weather proof , IP-54 including fixing of 10Amp MCB SP and clamps , nuts , bolts , washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit with 2 run of 1.5 sqmm FRLS flexible cable laying through PVC conduit from junction box to street light fitting complete all as specified and directed.
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 150 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 70 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 25 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 16 sqmm 2 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all as specified.
Cutting/ trimming of trees branches from LT/ HT lines upto 2 metre horizontal & 2 metre vertical distance from both sides of electric line including shifting of cut trees branches away from site complete all as directed. Note:- Distance between two adjacent poles irrespective of distance shall be considered as one span.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
Galvanized steel wire 4mm dia for earth wire/ guard wire onHT/ LT poles stretched without kinks, bend and binding with wire including fabrication of cradles hexagonal/ rectangular guards, spacers, road crossing etc., including taking down old wire of any type shape , size and removing from site, complete all as specified & directed .
Supply , fixing and straining of Aluminum conductor steel reinforced (ACSR) of any size on HT/LT over head line including necessary binding work, jumpering, maintaining proper sag as per IE rule including cutting of tree branches around the ACSR conductor within area of 5mtr complete all as specified & directed
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces and dismantling old structural steel work in cross arms and stacking at site, complete all as specified & directed.
Stay Assembly using stay rod of 20mm dia complete with accessories as shown in Electrical Plate No. 1 of SSR 2009 Part-I including galvanized steel stranded wire of size 7/4mm and taking out/ dismantling old stay assembly, complete all as specified (Loop type insulator, earth work and PCC shall be measured and paid for separately under respective items of BOQ)
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 90x140mm, clearance of hole 25.5 mm, complete all as specified and directed.
Renewal of Shackle type porcelain vitreous white, brown or green insulator working pressure 1100 Volts of 90mm dia 75mm height including galvanized mild steel strip of size 31x3mm ,size 12mm dia insulator bolt,washers and nuts complete all as apecified.
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 250 Amps 36 KA, MCCBs microprocessor release,overload adjustable = 0.4 to 1 x Inshort circuit adjustable 2.5 to 10 x Ir (250-400A) 2.5 to 8 x Ir (630A) time delay 0.1 - 0.2 sec. & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge. Note- Rate of extended terminal deemed to be included in this item.
S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 200 Amps, Icu 36 KA MCCBs, adjustable thermal and magnetic release & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge. Note- Rate of extended terminal deemed to be included in this item.
S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 160 Amps,Icu 25 KA MCCBs, adjustable thermal and magnetic release & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge. Note- Rate of extended terminal deemed to be included in this item
S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 100 Amps,Icu 25 KA MCCBs, adjustable thermal and magnetic release & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge. Note- Rate of extended terminal deemed to be included in this item
S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 63 Amps, Icu 40 KA MCCBs, adjustable thermal and fixed magnetic release & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge. Note- Rate of extended terminal deemed to be included in this item.
Cutting of existing road/ floor/ plinth/drain for taking out/laying of UG cable through GI pipe including necessary earth work excavation and making good to match with existing surface complete all as specified with PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) complete all as specified.
Painting to existing steel tubular HT/LT poles, 11m/9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed
Numbering of Poles with synthetic enameled paint complete all as specified and directed. (Note:- The numbering shall be hand written only stencils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width ).
Supply & fixed in repair UG LT PVC insulated armoured heavy duty cable end terminal joints (heat shrinkable) of along Pole etc suitable for aluminium conductor cable and testing after jointing of cable size 50-95 sqmm complete all as directed.
Supply & fixed in repair UG LT PVC insulated armoured heavy duty cable end terminal joints (heat shrinkable) of along Pole etc suitable for aluminium conductor cable and testing after jointing cable of size 150 sqmm complete all as directed.
Supply & fixed in repair HT/LT cable route indicator reading "MES LT UG 1100 V cable" and route of cable with arrow, made out of CI in square shape of size 200mm x 200mm x 10mm with 150mm leg, fixed in PCC pre-cast block of 250mm x 250mm x 1000mm complete all as directed.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 45 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of existing unserviceable driver for post top lantern LED fitting of capacity 25 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of existing unserviceable driver for post top lantern LED fitting of capacity 30 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 60 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of 25 watt LED new generation post-top energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source including necessary electric connection along with 40mm dia GI pipe 2.5 mtr long complete all as specified and directed.
Supply and fix in replacement of existing unserviceable SVL/HPSV fitting with new new generation energy saving and environmental friendly long life LED street light 30watt made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device including GI bracket of suitable size 1.5 mtr long bent to any shape required as per site and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box all as directed by Engr-in- Charge.
Supply, install, testing & commissioning of CPRI approval LT panel board, outdoor type IP-54 protection as per IS-8623 , floor mounted, factory made suitable for 415 Volt, 3 Phase, 4 wire, 50 HZ, AC supply system having bus bar chamber made out of size 1.2m x 1.2m x 45cm with angle iron of size 40 x 40 x 6 mm , duly supported with mild steel angle iron on plain cement concrete foundation (As per manufacturers instuctions) having height 60cms from ground level & 30 cms below ground level, with aluminium bus bars duly insulated by insulation of RYB colour 630 Amps rating mounted on porcelain insulators. The panels shall be factory made , double door, made out of 3.15 mm thick MS sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multi stranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:-
(a) MCCB 100Amps, 4Pole, 415 Volts AC supply, thermal magnetic release type 25 KA-01 No. (Incoming) (b) MCB 4 pole 63 Amp 415 V 50 Hz , AC supply - 03 Nos (c) MCB SPN 32 Amp 240 V 50 Hz , AC supply - 03 Nos (d) Current transformer rating 100/5, 5VA- Set of three (e) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current (0- 600 Amps) and frequency-01 No (f) RYB neon indicating lamp panel mounting type (Set of three ) - 01 N0. (g ) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses (h) Cable entry gland and two no earthing terminal
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32X6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 24 of tender doucments.
Mahashakti Enterprises
M/S MALHI CONSTRUCTIONS
surinder kumar jindal & bros.
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .