| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.3 L+₹2.2 L (19.6%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.4 L+₹2.3 L (20.3%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L3 | Rejected-Finance L3 | |
| 4 | L4₹13.6 L+₹2.5 L (22.3%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹13.8 L+₹2.7 L (24.4%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
1 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Bhamre Kiran S
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
COMPREHENSIVE REPAIRS TO SUMMER COOLING APPLIANCES AT AF STATION JAMNAGAR
2021_MES_428668_1
8791/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.1
₹22,000
Yes
28 May 2021
6 Mar 2021
2 Apr 2021
6 Mar 2021
1 Apr 2021
20 Mar 2021
60 days
Amount
Annual servicing of Inverter type split AC up to 2.0 ton capacity of any make, maintenance carried out by cleaning of cooling and condenser coil of indoor and outdoor units with descaling solution along with washing of filter and plastic body of indoor unit all as specified and directed by Engineer-in-Charge.
Dismantling Condenser fan motor of inverter Split type AC 1.5/2.0 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
Dismantling blower fan motor for indoor unit of Inverter type split AC 1.5 / 2 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
Supply and fix in repairs brass service valve of size 3/8" suitable for split ACs of any capacity.
Supply and fix in repairs brass service valve of size 5/8" suitable for split ACs of any capacity.
Supply and fix in repairs Copper tubing of size 3/8" suitable for split AC of any capacity with PVC insulation all around the pipe as per copper pipe size all as specified and directed by Engineer -in-charge
Supply and fix in repairs Copper tubing of size 5/8" suitable for split AC of any capacity with PVC insulation all around the pipe as per copper pipe size all as specified and directed by Engineer -in-charge
S&F in repairs Copper Condenser coil suitable for outdoor unit for Inverter type split type AC 1.5 TR / 2.0 TR cap of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections etc. all as specified and directed by Engineer-in-charge.
S&F in repairs Copper Chilling coil suitable for Indoor unit for Inverter type split type AC 1.5 TR / 2.0 TR cap of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections etc. all as specified and directed by Engineer-in-charge.
S&F in repairs PCB suitable for outdoor unit of inverter type split AC of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections etc. all as specified and directed by Engineer-in-charge.
S&F in repairs PCB suitable for indoor unit of inverter type split AC of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections etc. all as specified and directed by Engineer-in-charge.
Supply and fix in repair temperature sensor Suitable for indoor unit of Inverter type split AC.
Supply and fix in repair display suitable for indoor unit of Inverter type split AC 1.5/2.0 TR capacity of make LG/VOLTAS/BLUE STAR/CARRIER
Supply and fix in repair flexible PVC pipe for condense water outlet as per existing all as directed & as site requirement.
Material & labour for charging of refrigerant R-410A gas to 1.5/2.0 Ton capacity industrial type intelle split AC after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, including charging the unit with appropriate qty of gas as per manufacture's instruction complete all as directed by Engineer-In-Charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. Make :- ABB/LEGRAND/HAVELLS/L & T
Supply and fix in repair metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 10 Amps, 230 V, C type. Make of enclosure Legrand/Roma/Jaguar and Make of MCB ABB/LEGRAND/HAVELLS/L & T
M&L for replacement of new compressor including supply and charging the refrigerant gas, working on 230 V AC single phase in exchange of cut open compressor / UNCUT compressor suitable for split AC 1.5 TR capacity including Flushing the complete refrigerant system and supply including recharging the refrigerant to the required capacity after leak detection and repair if any in refrigerant piping and replacing the filter complete all as specified and directed. Make-Panasonic :- Model No :-5KS146EAA21 , Cap :- 1.5 TR cap or equivalent in Emerson Copeland / Godrej / Highly
M&L for replacement of new compressor including supply and charging the refrigerant gas, working on 230 V AC single phase in exchange of cut open compressor / UNCUT compressor suitable for split AC 2.0 TR capacity including Flushing the complete refrigerant system and supply including recharging the refrigerant to the required capacity after leak detection and repair if any in refrigerant piping and replacing the filter complete all as specified and directed. Make-Panasonic :- Model No :-5KS146EAA21 , Cap :- 2.0 TR cap or equivalent in Emerson Copeland / Godrej / Highly
Annual servicing of industrial type split AC 2.0 ton capacity of emerson make, maintenance carried out by cleaning of cooling and condenser coil of indoor and outdoor units with descaling solution along with washing of filter and body of indoor unit all as specified and directed by Engineer-in-Charge.
Material & labour for charging of refrigerant R-407 gas to 2.0 TR capacity industrial type intelle split AC after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, including charging the unit with appropriate qty of gas as per manufacture's instruction complete all as directed by Engineer-In-Charge.
Dismantling blower fan motor (HP-0.33 , V-415, RPM-920) of industrial type intelle split AC 2 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE.
Dismantling Condenser fan motor(KW-0.18,RPM-920,FRAME-S90, IP-44) of industrial type intelle Split AC 2.0 TR capacity and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE.
Supply and fix in repair LP switch 60 NO 35 PSI , 6A 250V suitable for compressor of industrial type intelle split AC 2.0TR Make - as per recommendation of OEM and approved by the GE.
Supply and fix in repair HP switch 400 NC 320 PSI suitable for compressor of industrial type intelle split AC 2.0TR capacity. Make - as per recommendation of OEM and approved by the GE.
Supply and fix in repair expansion valve suitable for industrial type intelle split AC 2.0 TR capacity. Model- TUBE 06802073 03989 , Make- Danfoss
Supply and fix in repair three pole contactor Model No. LC1D09 suitable for industrial type intelle split AC of 2.0 TR capacity.
Supply and fix in repair over load protection relay Model No. JRS4 09125D suitable for industrial type intelle split AC of 2.0 TR capacity.
Supply and fix in repair Supply Monitoring Device , Series-SM500,Type- PH, Neutral & Voltage Control suitable for control panel of industrial type intelle split AC. Cat id :- MACO4D0100E, Make - General industrial controls pvt ltd or or any other make as per recommendation of OEM and approved by the GE.
Supply and fix in repair transformer suitable for control panel of industrial type intelle split AC of 2.0 TR Capacity Emerson . Model:- 282500005012, Make-NANAP transformer pvt ltd or any other make as per recommendation of OEM and approved by the GE.
Supply and fix compressor Copeland scroll type , three phase , 415V, AC suitable for industrial type split Air Conditioner 2.0 TR Capacity working with R-407 Refrigerant gas including Flushing the complete refrigerant system and supply including recharging the refrigerant to the required capacity after leak detection and repair if any in refrigerant piping and replacing the filter complete all as specified and directed.
Make : Emerson Copeland Scroll, Model : 2R28K3E-TFD-522
Annual servicing of cassette type split AC upto 4.0 ton capacity of any make, maintenance carried out by cleaning of cooling and condenser coil of indoor and outdoor units with descaling solution along with washing of filter and body of indoor unit all as specified and directed by Engineer-in-Charge.
Dismantling Condenser fan motor of Cassette type Split AC upto 4.0 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
Dismantling blower fan motor for indoor unit of Cassette type Split AC upto 4.0 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
fakhrie apostrical
Ravi enterprise
Chamunda Kruparefrigeration
M/s Bombay Novelty Stores
Jyoti Refrigeration
Rameshwar Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .