| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAdmitted-Finance 1849 JUGRAJPUR SACHENDI KANPUR KANPUR NAGAR UTTAR PRADESH 208023 UDYAM UP 43 0012110 | KANPUR NAGAR | UTTAR PRADESH | 208023 | ₹4.2 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s. BALAJI CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|
| 1.00 | Supply of PLC Indoor panel Made out of 2 MM C.R sheet of size (800mm x 800mm x2100mm floor mounted)powdered coated 7 tank process with following component i.e,CPU should have 1 MB program memory with extended memory slut,Redundand-24VDC,SMPS 10Amp along with 24V DC SPD,IO count as DI-16,DO-20,AI-20,AO-08 & MODBUS-10 subsystem shall be same series as CPU,7inch Panel Mounted HMI,Modem should have support MQTT Protocol by default, 24volt DC Industrial switch with minimum 6 eathernate, 4 SFP Port each AI shall be equiped with sutitable signal isolator of 20Nos & surge protection device 20nos LIU Isolater, 230Volt AC/230volt AC torroidal transfermer,1KVA 230V AC UPS should have capacity to charge 3 nos 12 VDC 65 AH Battery Bank,DP MCB of Adequate current capacity,Led tube light 10inch 5 watt,door limit switch,Fan 6" with louver,4sqmm straight through terminal & fuse terminal 90 nos ,earthing plate.The Approved Make : (PLC- Siemens,Schnider,Phoenix,ABB,Mitsubishi SMPS-Phoenix,Siemens,Schnider Isolater-Masibus, Rishabh, Multispan SPD-Phoenix, Mersen, Dehn UPS-Vertive,Hitachi,High Rail,AVO, Eathernate switch-Siemense,Moxa,Phoenix) including cost of material with all taxes transporataion to Site/Storage with insurance. | 10 | Each | 2,82,000 ₹28,20,000 Lowest |
| 2.00Supply of electric powered electromagnetic full bore type IP 68 fully welded Flanged type water flow meter of Pulse DC type of Flow tube SS304, coil housing & electrodes SS316, SS ring type grounding etc with IP 68 signal converter remote mounting,input power supply 24V DC 4 - 20 mA,programable LCD display to show Actual flow rate, totalised flow, flow direction, flow velocity,conductivity with + or - 0.5 % accuracy etc & provision to diagnostics empty pipe detection, coil temperature, coil resistance etc & compatable to data communication modules with masibus & communication the data to remote SCADA station for live monitoring where ever required including providing data cable & power cable required as per site condition .The standard calibration certificate & guarantee certificate for flow meter & electromagnetic signal converter to be given for minimum one year from the date of installation.The Approved Make : (ABB,Krone,Immersion,Bermad,E & H) including cost of material with all taxes transporataion to Site/Storage with insurance. | ||||
| 3.00 | 350mm | 4 | Each | 4,15,000 ₹16,60,000 Lowest |
| 4.00 | 300mm | 4 | Each | 3,25,000 ₹13,00,000 Lowest |
| 5.00 | 250mm | 4 | Each | 2,74,000 ₹10,96,000 Lowest |
| 6.00 | 200mm | 14 | Each | 2,20,000 ₹30,80,000 Lowest |
| 7.00 | 150mm | 6 | Each | 1,74,000 ₹10,44,000 Lowest |
| 8.00Supply of double chamber DI Control valve (globe type) with solenoid , hydraulic operated with stem amd Positioner for feed back switch, selonoid valve, integral orifice plate assembly, differential control, reverse flow control, restriction orifice Body PN-1.6 can be integrated with PLC pannel for operation with a minimum Pressure in upstream 0.2 kg/cm2 to a maximum pressure of 8 kg/cm2 of The Approved Make : CLA,DOROT S-300,SINGER,BERMAD-700,VAG to control water supply including cost of material with all taxes transporataion to Site/Storage with insurance. | ||||
| 9.00 | 350mm | 4 | Each | 6,97,066 ₹27,88,264 Lowest |
| 10.00 | 300mm | 4 | Each | 5,88,247 ₹23,52,988 Lowest |
Tender Value
₹3.9 Cr
EMD Value
₹7.7 L
Closing Date
11 Oct 2022, 5:00 pmClosed
Chief Executive Officer
The Chief Executive Officer, WATCO Ground Floor, Unnati Bhawan, H.B. Colony, Satyanagar, Bhubaneswar-751007, Odisha, India (0674) 2391444
Procurement of Programme logic controller (PLC) panel, Flow Meter, Control Valve, Altitue valve, Chlorine Annalyser, etc for with 24x7 water supply to different 10 nos of DFT zones under WATCO Division, Cuttack
2022_WATCO_81876_1
WATCO (W)-26(5)/ 2022-23 Dt.28.09.2022
National Competitive Bid
Civil Works - Water Works
Item Rate
45 days
Cuttack
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,800
₹7.7 L
Yes
13 Oct 2022
1 Oct 2022
12 Oct 2022
1 Oct 2022
11 Oct 2022
1 Oct 2022
Amount
Supply of PLC Indoor panel Made out of 2 MM C.R sheet of size (800mm x 800mm x2100mm floor mounted)powdered coated 7 tank process with following component i.e,CPU should have 1 MB program memory with extended memory slut,Redundand-24VDC,SMPS 10Amp along with 24V DC SPD,IO count as DI-16,DO-20,AI-20,AO-08 & MODBUS-10 subsystem shall be same series as CPU,7inch Panel Mounted HMI,Modem should have support MQTT Protocol by default, 24volt DC Industrial switch with minimum 6 eathernate, 4 SFP Port each AI shall be equiped with sutitable signal isolator of 20Nos & surge protection device 20nos LIU Isolater, 230Volt AC/230volt AC torroidal transfermer,1KVA 230V AC UPS should have capacity to charge 3 nos 12 VDC 65 AH Battery Bank,DP MCB of Adequate current capacity,Led tube light 10inch 5 watt,door limit switch,Fan 6" with louver,4sqmm straight through terminal & fuse terminal 90 nos ,earthing plate.The Approved Make : (PLC- Siemens,Schnider,Phoenix,ABB,Mitsubishi SMPS-Phoenix,Siemens,Schnider Isolater-Masibus, Rishabh, Multispan SPD-Phoenix, Mersen, Dehn UPS-Vertive,Hitachi,High Rail,AVO, Eathernate switch-Siemense,Moxa,Phoenix) including cost of material with all taxes transporataion to Site/Storage with insurance.
Supply of electric powered electromagnetic full bore type IP 68 fully welded Flanged type water flow meter of Pulse DC type of Flow tube SS304, coil housing & electrodes SS316, SS ring type grounding etc with IP 68 signal converter remote mounting,input power supply 24V DC 4 - 20 mA,programable LCD display to show Actual flow rate, totalised flow, flow direction, flow velocity,conductivity with + or - 0.5 % accuracy etc & provision to diagnostics empty pipe detection, coil temperature, coil resistance etc & compatable to data communication modules with masibus & communication the data to remote SCADA station for live monitoring where ever required including providing data cable & power cable required as per site condition .The standard calibration certificate & guarantee certificate for flow meter & electromagnetic signal converter to be given for minimum one year from the date of installation.The Approved Make : (ABB,Krone,Immersion,Bermad,E & H) including cost of material with all taxes transporataion to Site/Storage with insurance.
Supply of double chamber DI Control valve (globe type) with solenoid , hydraulic operated with stem amd Positioner for feed back switch, selonoid valve, integral orifice plate assembly, differential control, reverse flow control, restriction orifice Body PN-1.6 can be integrated with PLC pannel for operation with a minimum Pressure in upstream 0.2 kg/cm2 to a maximum pressure of 8 kg/cm2 of The Approved Make : CLA,DOROT S-300,SINGER,BERMAD-700,VAG to control water supply including cost of material with all taxes transporataion to Site/Storage with insurance.
Supply of Chloroclam Quality WATER Quality Moniter for Residual Chlorine in Distributin Network,the Input Power Supply should be internal battery (2 of LSH 20 3.6V High Discharge Lithium Battery with Communication and Data Logging through GPRS Modem,Website,RS232 link to PC,RS232 link to Bluetooth dongle to mobile Device ,Storageof upto 55000 data points in the device and having Electrical Connections 1X 9Way Fischer Socket Yellow (102)Style for RS 232/Bluetooth dongle,1X 5Way Fischer Socket (103)Style for Chlorine Sensor,1X 9Way Fischer Socket red (102)Style for External Device,1X 7Way Fischer Socket Grey (102)Style for External Device having Environmental protection 1 P68 to 1m the Chloroclam is designed to fit within Standard Hydrant Chamber with Minimum of 300mm between the Hydrant outlet to the underside of the Chamber lid-150mm(w) x 164mm(h) Weight (The Chloroclam assembly weights approximately 1.5 kg with tubing acceseries and Regulator including cost of material with all taxes transporataion to Site/Storage with insurance.
Supply of DI Pilot Altitude Flow Valve of Double CHAMBER(Globe Type) with orfice plate for purpose to close valve at a maximum water level of ESR & to open to refill the ESR when the water level in the ESR at lowers.Altitude Control Valve should be worked at minimum pressure 1kg/cm2 .An altitude control valve controls the level of a tank. The altitude valve will remain open while the tank is not full and it will close when the tanks reaches its maximum level. The opening and closing of the valve will work without external power source (electric, pneumatic, or man power), it will work automatically,The body, Spool, & cover will be DI ASTM A-536 standard,Spring,steam, Jam Nut ,Cover bolt & cover washer should be SS , DI /SS Diaphragm plate,Nytril/Nylon diaphragm ,Bronze cover bushing,Seat plate & ring .The Approved Make : (VAG/SINGER/CLA/BURMAD-700/DOROT-S300)with 2 nos solenoid including cost of material with all taxes transporataion to Site/Storage with insurance.
Loading to ESR 350mm dia -
Loading to ESR 300mm dia -
Loading to ESR 250mm dia -
Loading to ESR 200mm dia -
Loading to ESR 150mm dia -
Supply of of PLC panel outdoor type double wall panel filled with glass wool/equivalent heat resistant material with panel mounted 230 V grade Air Conditioner outside wall should be of GI of 2mm with following component i.e,CPU should have 1 MB program memory with extended memory slut,Redundand-24VDC,SMPS 10Amp along with 24V DC SPD,IO count as DI-16,DO-20,AI-20,AO-08 & MODBUS-10 subsystem shall be same series as CPU,7inch Panel Mounted HMI,Modem should have support MQTT Protocol by default, 24volt DC Industrial switch with minimum 6 eathernate, 4 SFP Port each AI shall be equiped with sutitable signal isolator of 20Nos & surge protection device 20nos LIU Isolater, 230Volt AC/230volt AC torroidal transfermer,1KVA 230V AC UPS should have capacity to charge 3 nos 12 VDC 65 AH Battery Bank,DP MCB of Adequate current capacity,Led tube light 10inch 5 watt,door limit switch,Fan 6" with louver,4sqmm straight through terminal & fuse terminal 90 nos ,earthing plate.The Approved Make : (PLC- Siemens,Schnider,Phoenix,ABB,Mitsubishi SMPS-Phoenix, Siemens, Schnider Isolater-Masibus,Rishabh,Multispan SPD-Phoenix,Mersen,Dehn UPS-Vertive, Hitachi, High Rail, AVO, Eathernate switch-Siemense,Moxa,Phoenix) including cost of material with all taxes transporataion to Site/Storage with insurance.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.47 MB
BOQ_412067.xls
BOQ • 0.29 MB
DTCN.pdf
Tender Documents • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .