Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L1 | Accepted-AOC L1 AMONGST BONAFIDE BIDDERS | |
| 2 | L2₹27.9 L+₹60,066.92 (2.20%)Rejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-AOC NON BONAFIDE. QUOTED BELOW MINIMUM WAGES | |
| 3 | L3₹32.8 L+₹5.5 L (20.2%)Rejected-AOC | L3 | Rejected-AOC L3 AMONGST BONAFIDE BIDDERS | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Appropriate Category b(ii) | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Appropriate Category d(v) |
Tender Value
₹41.3 L
EMD Value
₹82,600
Closing Date
20 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR LIFT OPERATORS IN TYPE-II AND TYPE III BLOCK, DSC OR AND JCO QTRS, RAC, DIPR MAIN AND TECH BLDG AT KWC AREA UNDER GE I RND DELHI
2020_MES_360649_1
GE/RND-39/DLI/2020-2021
Open Tender
Manpower Supply
Item Rate
330 days
DELHI
Class-D, Cat d(v)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹82,600
Yes
25 Nov 2020
13 Jul 2020
22 Oct 2020
13 Jul 2020
20 Oct 2020
8 Oct 2020
60 days
Amount
PART-1 - OUTSOURCING SERVICES Outsourcing services for manning and operation of electrically operated lift of capacity 08 passangers - 02 Nos, (Make:- Schneider) suitable for G+7 (Ground+7 floors) installed at Type II and Type III Block to be operated in the three shift per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 Hrs 2nd Shift, 2200 hrs to 0600 Hrs 3rd Shift) in all working days including Sunday & Holidays by deploying one skilled Operator cum Mechanic per shift per day complete all as specified and as directed by Engineer-in-Charge.
Outsourcing services for electrically operated lift of capacity 08 passangers - 02 Nos, (Make:- Otis) suitable for G+4 (Ground+4 floors) installed at RAC Main building to be operated in the one shift per day (0830 hrs to 1730 hrs) from Monday to Friday by deploying one skilled Operator cum Mechanic per shift per day complete all as specified and as directed by Engineer-in-Charge.
Outsourcing of services for manning and operation RAC Main building electric substation and DG set along with pump house in the three shift per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 Hrs 2nd Shift, 2200 hrs to 0600 Hrs 3rd Shift) in all working days including Sunday & Holidays by deploying one skilled Operator cum Mechanic per shift per day complete all as specified and as directed by Engineer-in-Charge. The Installation mainly comprises of the following:
(A) LT Panel No-01 for RAC Main building consists of the following:- (i) Incoming ACB 800 Amps rating capacity-01 No (ii) Outgoing MCCB 630 Amps rating capacity-01 No (iii) Bus coupler 800 Amps rating capacity-01 No (iv) Outgoing MCCB 250 Amps rating capacity-01 No (v) Outgoing MCCB 200 Amps rating capacity-01 No (vi) Outgoing MCCB 100 Amps rating capacity-01 No (B) LT Panel No-02 for RAC office consists of the following:- (i) Incoming ACB 630 Amps rating capacity-01 No (ii) Outgoing MCCB 250 Amps rating capacity-01 No (iii) Outgoing MCCB 200 Amps rating capacity-01 No (iv) Outgoing MCCB 100 Amps rating capacity-10 No (v) Outgoing MCCB 63 Amps rating capacity-05 No (vi) Outgoing MCB 32 Amps TPN rating capacity-02 (vii) Outgoing MCB 40 Amps TPN rating capacity-01 (C) LT Panel No-03 for RAC Guest house consists of the following:- (i) Incoming MCCB 800 Amps of rating capacity-02 No (ii) Outgoing MCCB 400 Amps of rating capacity-02 No
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 3.00 above
Workers wage per person as per existing rules
ESIC (Employees state insurance contribution) as mentioned in tender document
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 4.01 to 4.03
LWC as mentioned in tender documents.
GST as mentioned in tender documents.
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost. (vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of lifts and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made.
(viii) Two pairs of uniform with name plate of operator and shoes shall be provided to each operator by the contractor. (ix) Cleaning of complete lift, machine room of lift, lift well greasing, tightening of nuts , bolts will be carried out by the operator employed by the contractor for every month. (x) First Aid box will be provided by contractor at each installation. (xi) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xii) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor. (xiii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiv) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of lifts for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xvi) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvii) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
PART-II: REPAIR/MAINTENANCE WORK S&F in repairs end termination joint 11 KV indoor type, heat shrinkable of size 50 Sqmm to 95 sqmm 3 core including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.
S&F in repairs cable jointing kit for 11KV (Earthed) grade cable for indoor termination, heat shrinkable of size 3 core 120 Sqmm to 185 Sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.
S&F in repairs straight through joint 11 KV heat shrinkable of size 3 core 50 Sqmm to 95 Sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.
S&F in repairs straight through joint 11 KV heat shrinkable of size 3 core 120 Sqmm to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.
S&F in repair of unreinforced Precast concrete cable cover, class HVP, Type 1 with peak, size 300mmx180mmx40mm complete all as specified and as directed.
S&F in repair of ACB 4 pole, 415 V, with Thermal magnetic release (Manual fixed type) of capacity 800 Amps including all necessary fixing arrangement suitable for fixing in existing panel complete all as specified and as directed.
S&F in repair of ACB 4 pole, 415 V, with Thermal magnetic release (Manual fixed type) of capacity 1250Amps including all necessary fixing arrangement suitable for fixing in existing panel complete all as specified and as directed.
S&F in repair of ACB 4 pole, 415 V, with Thermal magnetic release (Manual fixed type) of capacity 1600 Amps including all necessary fixing arrangement suitable for fixing in existing panel complete all as specified and as directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits). (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
Supply and laying in repair XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm 3 core complete all as specified and directed.
Supply and laying in repair XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 Sqmm 3 core complete all as specified and directed.
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 300 Sqmm 3 core complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm dia HDPE/GI pipe complete all as specified and directed
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB/OCB HT 11KV 400 to 630 amps of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component all as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load complete all as specified and directed Note:- (i) All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate for the same shall be included in quoted rates.
Calibration of relay of 11KV HT VCBs and 1.1KV ACBs installed at various sub stn at KWC area complete all as specified and directed. Note:- 1. All testing & calibration equipment with all accessories shall be brought by the contractor and rate for same is deemed to be included in quated rates. 2. The complete test report shall be submitted by the contractor to Engineer-in-Cahrge/GE duly signed by all concerned.
S&F in repair MCB of capacity 6 to 32 Amps 'C' curve 240 V 50 HZ complete all as specified and directed.
S&F in repair of fuse base suitable for cynlindrical/DIN type MCB of capacity 6 to 32 Amps complete all as specified and directed.
S&F in repair of closing spring assembly complete all as specified and directed.
S&F in repair of tripping spring assembly complete all as specified and directed.
S&F in repair of charging motor cut off limit switch complete all as specified and directed.
S&F in repair of spring charging handle motorized mechanism of VCB complete all as specified and directed. Make:- CG/ABB or equivalent approved.
S&F in repair of push button bracket assembly complete all as specified and directed. Make:- CG/ L&T or equivalent approved.
S&F in repair of bus bar (set of three) support insulator 75 mm dia including all fixing accessories complete suitable for VCB/HT Bus bar chamber all as specified and directed. Make:- Jaipuriya or equivalent approved.
S&F in repair of bus bar barrier as existing (set of three) with nuts bolts complete all as specified and directed. Make:- CG/ andrew Yule or equivalent approved.
S&F in repair of toggle switch for space heater complete with all accessories all as specified and directed. Make:- CG/ L&T or equivalent approved.
S&F in repair of Charged/Discharged indication assembly complete all as specified and directed.
M&L in replacement of control wiring matching with existing size/type including proper laying with the help of locking device as per manufacturer instruction complete all as directed.
Taking down repairable potential transformer of HT VCB 11 KV/ 110 V of any make, opening & dismentling the complete unit and refitting after carry out the following repairs/replacement :- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of the PT. (c) Replacement of wornout nuts/bolts and other minor parts including HRC Fuse. (d) Soldering / tightening of loose connections. (e) Replacement of potential transformer oil having dielectric strength upto 50 KV. (f) Painting of outer portion of PT with synthetic enameled paint of grey colour of approved make. (g) Testing of the PT's for proper functioning to the entire satisfaction of the engineer in charge.
S&F in repair of unserviceable/not repairable potential transformer of HT VCB 11 KV/110 V of any make complete all as specified and as directed by Engr-in-Charge
S&F in repair of 11 pin anti pumping relay 110V (set of three) DC complete all as specified and directed. Make:- CG/L&T/Andrew yule.
S&F in repair of bottom terminal with jaw (set of three) contact complete all as specified and directed. Make:- CG/L&T/Andrew yule.
S&F in repair of Top terminal with jaw contact (set of three) complete all as specified and directed. Make:- CG/L&T/Andrew yule
S&F in repair of space heater 230V AC 80W complete with all accessories all as specified and directed. Make:- CG/CE/ABB
S&F in repair of thermostate complete with all accessories all as specified and directed. Make:- CG/Andrew yule
S&F in repair of PT epoxy female bushing suitable for R-Y-B (set of three) phase complete all as specified and directed. Make :- CG/Andrew yule.
S&F in repair of PT epoxy male bushing suitable for R-Y-B phase (set of three) complete all as specified and directed. Make :- CG/Andrew yule.
S&F in repair of PT fuse 11 KV complete all as specified and directed. Make :- CG/Andrew yule.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and as directed.
Supply and topping up transformer oil having dielectric strength not less than 50 KV complete all as specified and directed. Make: Savita/Power.
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 400 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking the any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete to the entire satisfaction of engineer- in-charge.
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 500 to 1000 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking the any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete for entire satisfaction of engineer incharge.
Taking shut down from main substation and M&L for painting with using spray gun with two coats of synthetic enamel grey paint over a coat of red oxide primer including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of transformer including base frame, connected LT panels, duct covers including writing MES/SM No of existing size/surface complete all as directed.
S&F in repairs HT bushing (set of three) 11KV suitable for 200 to 1000 /1500KVA Transformer including brass rod and complete with gasket as per matching to existing all as specified and as directed.
S&F in repairs LT bushing (set of four) 1.1 KV suitable for 200 KVA to 1000 /1500 KVA transformer including brass rod and complete with gasket as per matching to existing all as specified and as directed.
S&F in repair of head gasket sheet 6mm thick suitable for Transformer 200KVA to 450 KVA capacity including replacement of nuts, bolts, washers complete including necessary T&P required at site all as specified and as directed.
S&F in repair of head gasket sheet 6mm thick suitable for Transformer 500KVA to 1000 KVA capacity including replacement of nuts, bolts, washers complete including necessary T&P required at site all as specified and as directed.
S&F in repair of Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 200 KVA to 1000KVA complete as per matching to existing all as specified and as directed by Engineer in charge.
S&F in replacement of temperature gauge analog type complete with all accessories as per matching to existing all as specified and as directed by Engineer in charge.
S&F in repairs voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and as directed.
S&F in repairs ammeter digital type for current range of (0-1000Amps) as per matching to existing including all accessories and wiring complete all as specified and as directed.
S&F in repairs power factor meter digital type for frequency range (45-65 Hz) as per matching to existing one including all accessories and wiring complete all as specified and as directed.
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing one including all accessories and wiring complete all as specified and as directed.
S&F in repair three phase overcurrent earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete all as specified and as directed.
S&F in repair three phase digital KV meter range up to 15 KV as per matching to existing one including all accessories i.e KVAH, KVAR, KW, Amp, Volt, frequency for each phase complete & control wiring complete all as specified and as directed.
S&F in repair of A/M Switch complete all as specified and directed.
S&F in repair of LED type Indicating lamp type of voltage AC/DC set of RYB (set of three) as per matching to existing.
S&F in repair of battery charger 12 volt suitable for charging batterry 12 Volt 180AH complete all as specified and directed.
S&F in repair of battery charger 24 volt suitable for charging batterry 02 Nos of 12 Volt 180AH complete all as specified and directed.
S&F in repair of Current Transformer (set of three) as per matching to exisitng complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of Multifunctional meter complete all as specified and as directed.
S&F in repair of VCB Power Pack unit 24 Volt DC 7 AH with baitary bank for backup including panel as per matching to exisitng complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed.
S&F in repair of 3 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed.
S&F in repair of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed.
S&F in repair of 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and as directed.
S&F in repair of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed.
S&F in repair of 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and as directed.
S&F GI cable tray 2 mm thick with top openable cover in 1.6 mm of size 75X 450X 75 mm with all necessary fittings and fixtures and fixing on walls to conceal the cable of various sizes all as specified and directed.
S&F in repair ACP retro sign board of size 2.2m x 1.2m using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT Sub Station detais, and Single line Schematic diagram. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on stainless steel tubular poles 10 feet height of 50mm dia including PCC 1:2:4 type B-1 for foundation including earth work in any types of soil and fixing of clamps, nuts, bolts, washer etc complete all as directed by Engineer-in-Charge.
S&F repair ACP retro sign board of size 1.5m x 1.1m using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT subtation Details, and Single line Schematic diagram. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on steel tubular poles 10 feet height of 50mm dia including PCC 1:2:4 type B-1 for foundation including earth work in any types of soil and fixing of clamps, nuts, bolts, washer etc complete all as directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for taking out and laying of LT Cables complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for taking out and aying of LT Cables complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed
Supply and laying GI pipe light grade of 150mm dia laid in trenches for protection of UG cable complete all as specified and directed.
Supply and laying in repair GI pipe light grade of 100mm dia laid in trenches for protection of UG cable complete all as specified and directed.
Supply and laying in repair GI pipe light grade of 50mm dia laid in trenches for protection of UG cable complete all as specified and directed.
S&F in repair of lift cabin light fittings as per existing fittings all as specified and directed by Engr-in-Charge.
S&F in repair of ARD Battery for lifts 12 Volts 7 AH all as specified and directed.
S&F in repair of Steel Wire Rope 13 MM dia for lifts all as specified and directed.
S&F in repair of lift cabin fan as per OEM specification as per the existing fitting complete all as specified and as directed
S&F in repair of lift door sensor as per OEM specification and existing model complete all as specified and as directed
S&F in repair of control wiring for lift panel with 2.5 sqmm multistranded FRLSH copper cable for the lift of existing make complete all as specified and as directed.
S&F in repair of push button with indicator as per OEM specification complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for repairing of road cuts/ hard standing etc complete all as specified and as directed.
BRIJ MOHAN LAL AND CO.
RUHI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .