Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹14.9 Cr
EMD Value
₹14.9 L
Closing Date
19 Jul 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Construction of Pre Engineered Structural building with RCC Foundation, Boundary wall, utility building, Road work, Water Tank, Fire fighting, Internal & External electrical work, STP, WTP, RWH, Internal and External Plumbing, Solar Panel light, landscaping and Horticulture work etc.
NBCCSBGRECEMNoida03~EW599cf677849932ac6ab7944c
NBCCSBGRECEMNoida03
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
₹14.9 L
19 Jul 2022
17 Jun 2022
19 Jul 2022
17 Jun 2022
19 Jul 2022
Bill of Quantity
S. NO DESRIPTION COST OF DSR ITEMS COST OF NON DSR ITEMS
2 FIRE FIGHTING WORKS 78,73,815.90 9,39,941.00
3 INTERNAL PLUMBING WORKS 7,88,460.00 2,68,098.00
4 EXTERNAL PLUMBING WORKS 35,72,206.00 2,70,075.00
6 ELECTRICAL WORKS 24,93,881.37 86,53,891.06
7 FIRE ALARM & PA SYSTEM WORKS 11,77,342.00 3,43,587.69
TOTAL COST OF DSR + NON DSR ITEMS 14,88,41,715
Digitally signed by ASHWANI
ASHWANI KUMAR BANSWA
KUMAR BANSWA Date: 2022.06.17 18:55:41
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
S.No. DSR 2021 Description Unit TOTAL QTY. RATE DSR 2021 RATE NON DSR TOTAL DSR AMOUNT
2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-incharge
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc.
in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and cum 1898.91 253.95 482229.02 0.00
watering, lead up to 50 m and lift upto 1.5 m.
3 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport
upto a lead of 5km also including ramming and watering of the earth in layers not exceeding cum 14430.54 368.65 5319819.65 0.00
20 cm in trenches, plinth,sides of foundation etc. complete.
2.26 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or
stacked materials.
5 2.27 Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming,
consolidating and dressing complete.
2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding
15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2.34 Supplying chemical emulsion in sealed containers including delivery as specified.
7 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Ltr. 1623.00 200.90 326060.70 0.00
Diluting and injecting chemical emulsion for POST CONSTRUCTIONAL
anti-termite treatment (excluding the cost of chemical emulsion) :
2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres /
sqm of the vertical surface of the substructure to a depth of 300mm including excavation
channel along the wall & rodding etc. complete:
8 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration meter 300.00 32.30 9690.00 0.00
4 CONCRETE WORK
9 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 342.07 6326.05 2163951.92 0.00
10 4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
5.00 REINFORCED CEMENT CONCRETE
5.9 Centering and shuttering including strutting, propping etc. and removal of form for
11 5.9.1 Foundations, footings, bases and foundations for shed columns sqm 720.14 307.95 221766.19 0.00
12 5.9.2 Walls ( any thickness) including attached pilasters, buttresses, plinth and string courses etc.
13 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 934.00 766.55 715957.70 0.00
14 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 700.37 608.35 426068.26 0.00
15 5.9.6 Columns, piers, abutments, pillars, posts and struts. sqm 1664.42 804.25 1338608.58 0.00
16 5.9.7 Stairs, (excluding landings) except spiral-staircases sqm 20.59 657.75 13543.40 0.00
17 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
18 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 128379.71 89.65 11509241.00 0.00
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in
position and binding all complete above plinth level.
19 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 55386.22 89.65 4965374.74 0.00
20 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of concrete
to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,
finishing and reinforcement as per direction of the engineer-in-charge; for the following
grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall
be payable separately. In case the cement content in design mix is more than 110% of the
minimum specified cement content, the contractor shall have discretion to either re-design
the mix or bear the cost of extra cement.
5.33.1 All works upto plinth level :
21 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 973.64 8683.80 8454895.03 0.00
5.33.2 All works above plinth level upto floor V level
22 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 214.45 10306.20 2210205.02 0.00
6.0 MASONRY WORK
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
23 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 88.87 6658.25 591749.26 0.00
6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level in all shapes and sizes in :
24 6.4.2 With F.P.S.(non modular) bricks cum 398.47 8288.35 3302689.52 0.00
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level.
25 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 45.12 1018.05 45934.42 0.00
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of
half brick masonry.
26 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300
mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at
6.47 sill level and lintel level with approved block laying polymer modified adhesive mortar all cum 142.52 6994.15 996802.76 0.00
complete as per direction of Engineer-in-Charge. (The payment of RCC band and
reinforcement shall be made for seperately).
8 CLADDING WORK
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations
of required size,approved shade, colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching
pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give
high gloss finish etc. complete at all levels.
8.2.2 Granite stone slab colour black, Cherry/Ruby red
8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including
machine polishing to edge to give high gloss finish etc. complete as per design approved by
Engineer-in-Charge.
9 WOOD AND P. V. C. WORK
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less
than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
30 9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer
(having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and
door width upto 700 mm), with necessary accessories and screws etc. complete.
9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic
coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and
shade, with necessary screws etc. complete.
31 9.101.2 Twin rubber stopper each 22.00 62.25 1369.50 0.00
32 9.128 Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of
required colour, size and design made by ResinTransfer Moulding (RTM) Machine Technology,
resulting in void free compact laminate in single piece, having smooth gradual slope curvature
for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2
mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50
mm flanges duly inserted and sealed in the wall complete in one single piece casted
monolithically, including all necessary fittings . The FRP Chajja should be manufactured using
unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand
mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for
complete resistance from the extreme of temperature, weather & sunlight (Only plan area of
chajjas shall be measured for making payment).
33 9.161 Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x
60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc
coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door
Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ .
The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on
horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made meter 10.80 1791.05 19343.34 0.00
Template for hinges is excluded). SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire
rated glazed shutter . The frame shall be finished with a approved fire resistant primer or
Powder coating of not less than 30 micron in desired shade as per the directions of Engineer -
in- charge . (Cost of SS ball bearing
34 9.162 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating
confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-charge,with suitable mounting on door frame, consisting of vertical
styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out
of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool
insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing
hinges of size 100x89x3mm of approved make, including applying a coat of approved fire
resistant primer or powder coating not less than 30 micron etc all complete as per direction of
Engineer-in-charge (panelling to be paid for seperately).
35 9.164 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with
G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of
size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and
150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of
not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc
complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of gineer-
in-charge with glass of required thickness having 120 minutes of fire resistance both integrity
& radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer
have to give test report/certification of fire glass and the glass should have the stamp
showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or
by any other accreditation body hich operates in accordance with ISO/IEC 17011 and
accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The
maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
36 9.139 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch &
Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the each 4.00 7145.90 28583.60 0.00
Engineer- in- charge, all complete.
10.0 STEEL WORK 0.00
10.11 Providing and fixing factory made ISI marked steel glazed doors, windows
and ventilators, side /top /centre hung, with beading and all members
such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled
steel sections, joints mitred and flash butt welded and sash bars tenoned
and riveted, including providing and fixing of hinges, pivots, including priming coat of
approved steel primer, but excluding the cost of other fittings, complete all as per approved
design, (sectional weight of only steel members shall be measured for payment).
37 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of
C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3
mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including
applying a priming coat of approved steel primer.
38 10.5.2 Using flats 30X6m for diagonal braces and central cross piece. sqm 12.60 4615.15 58150.89 0.00
10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths,
interlocked together through their entire length and jointed together at the end by end locks,
mounted on specially designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete, including the cost of
providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel
wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling shutters.
39 10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. sqm 44.00 3008.80 132387.20 0.00
10.8 Extra for providing mechanical device chain and crank operation for operating rolling shutters.
40 10.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area sqm 44.00 1108.70 48782.80 0.00
41 10.19 Providing and fixing mild steel round holding down bolts with nuts and washer plates
complete (Hardware/Bolt Conferming Grade-8.8/4.4).
Providing, fabricating and erection of structural steel work in factory fabricated machine
welded and finished structural elements with plates, angles, channels, beams etc. of specified
grade of Fe 345 WA/WB as per IS 2062 to form structural members for all span beams &
columns as per GA drawings to meet all IS codal requirements based on the design approved
by structural Engineer. The rate shall include trasporation of materials from steel
manufacturer's yard to factory fabrication yard and then to site of work, making all necessary
NON DSR arrangement for safe handling and erection and hoisting i.e. like making temporary sturdy
structure to take erection loads and loads of the fabricated sections/ materials during
execution, dismantling temporary structure after completion of structure etc. Applying Primer
(min. 50 micron thk) of approved make with min. 70 micron enamel paint of approved
make(colour to be approved by engineer in charge) and all work shall be carried out true to
line and levels as per approved drawings and specifications.
The rate shall include cost of preparation of shop & GA drawings based on approved
structural design and drawing sincluding incorporating modification and preparation of
revised shop drawing as per direction of Engineer-in-Charge, materials and all operation like
cuttings, bevelling, tack welding, fine welding and re-welding, filling and smoothening the
edges to remove any blurrs and additional welds, making holes to receive nuts and bots as
required at site and in factroy fabrication yard to maintain line & level, providing required
machinery like hydra, cranes, jigs & fixtures, all necessary tools and plants to handle
structurral material, temporary jointing and disjointing, labour for carrying erection and
geometrical control survey, field and lab testing charges etc. all complete as per approved
architectural, structural and shop drawings and direction of Engineer-in-Charge.
42 NON DSR built up/ Hot rolled section kg 227073.00 125.00 0.00 28384125.00
45 Providing and fixing 0.47mm Bare galvalume roof sheet AZ -150, ,550MPA including ridge,
NON DSR flashing, over lapping, etc complete (plan area should be measured, nothing extra shall be sqm 3400.00 650.00 0.00 2210000.00
paid for lap, profile (valley, crest) etc.)
46 Providing and fixing 0.5mm precoted galvalume wall cladding sheet AZ-150, 550MPA
NON DSR including flashing, trim , over lapping, etc complete (plan area should be measured, nothing sqm 1968.00 700 0.00 1377600.00
extra shall be paid for lap, profile etc.)
47 Providing and fixing Gutter in 0.5mm precoted galvalume 550MPA with supporting members.
48 NON DSR Providing and fixing 2mm thk ploycarbonete sheet for sky lights. sqm 144.00 1700 0.00 244800.00
49 Providing and fixing Metal deck sheet 250Mpa, 0.8mm thk (plan area should be measured,
nothing extra shall be paid for lap, profile etc.)
11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished
with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing
of steps etc. complete.
50 11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 588.86 545.00 320928.54 0.00
51 11.37 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sqm 247.18 935.60 231258.75
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in
white cement mixed with pigment of matching shade complete.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4
coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with
white cement and matching pigments etc., complete.
53 NDSR Vapour Barrier :- Providing and Laying one layer of LDPE sheet of 150 microns thk approved
quality on sub base of flooring with an overlapping of 150mm on longitudinal direction and
300mm on transvers direction joints etc complete as per engineer in charge.
NDSR Providing & Laying "TRIMIX VACCUM DEWATERING SYSTEM" with M - 30 Grade mix cement
concrete (Min. cement content @ 340Kg/Cum) for spreading, screeding, dewatering, floating
& troweling with the help of power trowelling floater of concrete floor as directed & specified
using necessary steel form work with M.S. Channels including providing & laying separation
layer of 150 micron (LDPE) expanded polythin foam sheets. Rate includes forming
construction & Construction joints 4 mm to 6 mm wide by cutting the floor upto 20 %(1/5th)
depth of thickness of the concrete depth using mechanical saw up to full depth of cutting
including providing & fixing M.S. dowells bars with bitumen painted of full length as shown in
drawing as to form the bays not exceeding 6.0 m x 4.5 m, including 4.0kg/sqm hardner,
Isolation Joint-Wall/Colunm, Providing & proper fixing of 10mm thick armour board for
isolation joints between Floor and walls etc. complete as per direction & as per Drawing &
Design approved by the Engineer Incharge. (Steel Reinforcement paid saparately)
12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone
aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3
fine sand) as per standard design :
56 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and
finishing the outlet complete.
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion,(i) Single socketed pipes.
Note :- Rates for external plastic are for height upto 10m from ground level in less
otherwise stated.
58 13.1.2 P/L 12mm cement plaster of mix 1:6 ( 1 cement : 6 Fine sand ) . sqm 3545.71 282.00 999891.26 0.00
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :
60 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion Per bags of 50kg cement
recommended by the manufacturers. used in the mix
13.16 6 mm cement plaster of mix :
13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than
50 gms/litre, of approved manufacturer, of required shade and colour complete, as per
manufacturer's specification.
62 13.42.1 Two or more coats on new work sqm 1778.29 92.75 164936.01 0.00
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
63 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primersqm 3392.64
13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even
64 13.61.1 Two or more coats on new work sqm 738.30 131.45 97049.27 0.00
65 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved
brand and manufacturer, over the plastered wall surface to prepare the surface even and sqm 2124.99 123.85 263180.14 0.00
smooth complete.
15 DISMANTLING AND DEMOLISHING
15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material
within 50 metres lead as per direction of Engineer - in - charge.
66 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) cum 2.00 1239.60 2479.20 0.00
15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and
disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- cum 5.00 2928.10 14640.50 0.00
15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable
material and disposal of unserviceable material within 50 metres lead as per direction of
Engineer-in-charge.
16.43 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/
runways, using cement content as per designmix, using coarse sand and graded stone
aggregate of 40 mm nominal size in appropriate proportions as per approved & specified
design criteria, providing dowel bars with sleeve/ tie bars wherever required,laying at site,
spreading and compacting mechanically by using needle and surface vibrators, levelling to
required slope/ camber,finishing with required texture, including steel form work with sturdy
M.S. channel sections, curing, making provision for contraction/expansion, construction &
longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and
filling joints with approved joint filler and sealants, complete all as per direction of Engineer-
in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per
design mix is payable/ recoverable separately.
69 16.43.2 Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to
site in transit mixer
16.46 Providing and filling in position rubberized bitumen hot sealing compound for sealing of
expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.
70 16.46.1 Using grade 'A' sealing compound conforming to IS: 1834. per cm
16.59 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick
aluminium sheet, face to be fully covered with high intensity encapsulated type heat
activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and
silver white or other colour combination including subject matter, message
(bilingual),symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive
backing which shall be activated by applying heat and pressure conforming to class -2 of
ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c
to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant
measures, mounted and fixed with 2 Nos.M.S. angles of size 35x35x5 mm to a vertical post
made up to M.S.Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm
at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S.
message plate of required size, steel work to be painted with two or more coats of synthetic
enamel paint of required shade and of approved brand & manufacture over priming coat of
zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white
colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint
over and including appropriate priming coat including all leads and lifts etc. complete as per
drawing , specification and direction of Engineer-in-charge.
71 Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm
with support length of 3650 mm
16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement
concrete in position to the required line, level and curvature, jointed with cement mortar 1:3
(1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints
except at sharp curve shall not to more than 5mm), including making drainage opening cum 54.54 8613.55 469783.02 0.00
wherever required complete etc. as per direction of Engineer-in-charge (length of finished
kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by
72 Engineer-in-charge).
16.78 Construction of granular sub-base by providing close graded Material conforming to
specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers
to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor
grader on prepared surface and compacting with vibratory power roller to achieve the desired
density, complete as per specifications and directions of Engineerin-
73 16.78.2 With material conforming to Grade-II (size range 75 mm to 0.075 mm ) having CBR Value-
74 16.79 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to
0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with
water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in
sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to
10 tonne capacity to achievethe desired density, complete as per specifications and directions
of Engineer-in-Charge.
16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in
footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness &
size/ shape, made by table vibratory method using PU mould, laid in required colour &
pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying
of inter locking paver blocks into the sand bedding layer through vibratory compaction by
using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size
and per direction of Engineer-in-Charge.pattern, finishing and sweeping extra sand. complete
75 16.91.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design &
76 P/Grouting GP2 of Fosroc make in bases of columns etc., including cleaning, sealing the edges
with C.mortar for grouting all complete as per standard specifications and the directions of kg 4250.00 25.00 106250.00
NDSR the Engineer in charge.
77 NDSR Providing, laying and fixing in slope as per drawing or as directed by Engineer-In-charge, 300
wide prefabricated saucer drain along the road to connect and take storm water catch basin, meter 393.00 750.00 294750.00
with average thickness of 80 mm in concrete grade of M-30.
78 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS
: 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112
mm space between protruded legs having 2 mm tread on top surface by ribbing or
chequering besides necessary and adequate anchoring projections on tail length on 138 mm
as per standard drawing and suitable to with stand the bend test and chemical resistance test
as per specifications and having manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6
(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per
19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape
and approved quality
79 19.19.3.1 Circular shape 560 mm internal diameter each 13.00 1494.20 19424.60
21 ALUMINIUM WORK
Providing and fixing aluminum work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/appropriate Z sections and other sections
of approved make conforming to IS:733 and IS: 1285, fixing with dash fastners of required dia
and size, including necessary filling up the gaps at junctions, i.e. at the top, bottom
and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing/paneling, C.P brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-
charge.(Glazing paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
80 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 954.42 466.30 445046.05
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall be paid for separately)
81 21.1.2.2 Powder coated aluminium (minimum
thickness of powder coating 50 micron)
21.20 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or
graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in
aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel
screwsetc. complete as per architectural drawings and directions of Engineerin- charge.
82 21.2.1 Pre-laminated particle board with decorative laminationon one side and balancing lamination
21.8 Filling the gap in between aluminium frame & adjacent RCC / Brick / Stone work by
providing weather silicon sealant over backer rod of approved quality as per architectural
drawings and direction of Engineerin-Charge complete.
83 21.8.1 Upto 5 mm depth and 5 mm width meter 146.50 85.25 12489.13
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the
directions of engineer-in-charge . (Cost of aluminium snap eading shall be paid in basic item):
84 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) sqm 80.67 1019.80 82267.27
21.4 Providing and fixing double action hydraulic floor spring of approved brand and manufacture
conforming to IS : 6315, having brand logo embossed on the body / plate with double spring
mechanism and door weight upto 125 kg, for doors, including cost of cutting
floors,embedding in floors as required and making good the same matching to the existing
floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with
slide plate etc. complete as per the direction of Engineer-in-charge.
85 21.4.1 With stainless steel cover plate minimum 1.25 mm thickness. each 2.00 2448.85 4897.70
86 21.13 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles
(best make of approved quality) for aluminium doors including necessary cutting and making each 7.00 449.55 3146.85
good etc.complete.
87 21.16 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc.
complete as per direction of Engineer-incharge
88 21.16.2 Powder coated minimum thickness 50 micron aluminium each 44.00 89.60 3942.40
22 WATER PROOFING
22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for
construction/ expansion joints between two RCC members and fixed to the reinforcement
with binding wire before pouring concrete etc. complete :
89 22.4.2 Dumb bell with central bulb (180 mm wide, 8 mm thick) meter 368.00 232.05 85394.40
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound
conforming to IS 2645 in recommended proportions including rounding off junction of vertical
and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
proofing compound in recommended proportion including rounding off junction of vertical
and orizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
90 (iV) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm
wide and pasted to each other with bitumen @ 1.7 kg/sqm).
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by
applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound
@ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours
(b) (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with
water layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
91 The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions
of pipes and masonry with polymer mixed slurry.
92 NDSR P/L cinder concrete in cement 1:15 (1 cement :15 cinder of 12.5 mm size) on terraced roof
laid to slope I/c consolidating the same.
23.0 RAIN WATER HARVESTING & TUBEWELLS
93 23.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge
pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in- cum 18.00 1302.30 23441.40
94 23.6 Supplying, filling, spreading & leveling coarse sand of size range 5 mm to 10 mm in recharge
pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of cum 10.33 1309.00 13524.59
Engineer -incharge
95 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge
pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of cum 4.61 1309.00 6031.87
Engineer -incharge
NEW TECHNOLOGIES & MATERIALS
26.22 Providing and fixing false ceiling at all heights with integral densified calcium silicate
reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved
texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal
level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of
0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T
runners of size 24x38mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid
module of size 600 x 600 mm,suspended from ceiling usinggalvanised mild steel items
(galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded
hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed
with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron
perimeter wall angle or size 24x24x0.40mm of length 3000 mm to be fixed on periphey wall /
partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry
wall S.S screws. The workshall be carried out as per pecifications, drawing and as per
directionsof the Engineer-in-Charge.
96 26.22.1 With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles sqm 90.00 1777.50 159975.00
HORTICULTURE & LANDSCAPING
97 2.10 Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60
days or more till the grass forms a thick lawn, free from weeds and fit for mowing including
supplying good earth, if needed (the grass and earth shall be paid for separately). sqm 4500.00 17.70 79650.00
In rows 5 cm apart in both directions
98 7.5 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag
of size 25 cm as per direction of the each 25.00 65.00 1625.00
officer-in-charge.
99 7.6 Supply and stacking of Bassia latifolia (Mahua) plant of height 90-105 cm. in big polybag of
size 25 cm as per direction of the officer-in-charge.
100 7.53 Supply and stacking of Mangifera indica (Mango-grafted ) plant of height
60-75 cm. in big poly bag of size 25 cm as per direction of the officer-incharge.
101 7.75 Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag
of size 30 cm as per direction of the officer-incharge.
102 7.83 Supply and stacking of Eugenia jambolana (Jamun) plant of height 150- 165 cm. in big poly
bags of size 25 cm as per direction of the officer-in-charge.
Total Amount 68421906.6 51090859.6
Total Amount 68421906.6 51090859.6
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
FIRE FIGHTING SYSTEM
S.No DSR 2019/NON Description Unit Qty Rate DSR-2019 Rate NON Amount DSR Amount NON
Pump shall be capable of handling not less than 150% of rated
capacity at a head not less than 65 % of rated head. The shut off head
shall not exceed 120% of rated head. HP of motor should be 20%
more than the calculated HP.
1 1 Supplying, installation, testing and commissioning of Electric driven
Main Fire Pump suitable for automatic operation and consisting of
following, complete in all respects, as required :
(a) Horizontal type, multistage, centrifugal, split casing pump of cast
iron body & bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous
speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50
Hz, AC supply with IP 55 protection for enclosure, horizontal foot
mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered with anti
vibration pads.
1.5 2280 lpm at 70 m Head (For Main Electric Hydrant Pump) Set 1 367296.00 367296.00 0.00
1.5 2280 lpm at 70 m Head (For Main Electric Sprinkler Pump) Set 1 367296.00 367296.00 0.00
1.9 1620 lpm at 56 m Head (For Main Electric Water Curtain Pump) Set 1 282515.00 282515.00 0.00
Note: *The head of the pump is selected in a manner so as to give a
minimum 3.5kgf/cm2 pressure at the highest/farthest point.
Note: *The head of the pump is selected in a manner so as to give a
minimum 1.4kgf/cm2 pressure at the highest/farthest point for Water
2 2 Supplying, installation, testing and commissioning of diesel engine
driven main fire pump suitable for automatic operation and
consisting of following, complete in all respects, as required :
(Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and
bronze impeller with stainless steel shaft, mechanical seal conforming
Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant IS standard complete with auto starting
mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly insulated
with 50 mm thick glass wool with 1.0 mm thick aluminium
sheet cladding, residential silencer, instruments and
protection as per standard specification, stop solenoid for auto
stop in the event of fault with audio indications, painted with post
office red colour etc. as required.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant IS standard complete with auto starting
mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly insulated
with 50 mm thick glass wool with 1.0 mm thick aluminium
sheet cladding, residential silencer, instruments and
protection as per standard specification, stop solenoid for auto
stop in the event of fault with audio indications, painted with post
office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
Note: *The head of the pump is selected in a manner so as to give a
minimum 3.5kgf/cm2 pressure at the highest/farthest point.
3 3 Supplying, installation, testing and commissioning of electric driven
pressurisation pump suitable for automatic operation and
consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal pump of cast iron body and
bronze impeller with stainless steel shaft, mechanical seal conforming
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class
of protection for enclosure, horizontal foot mounted type with Class-
'F' insulation,conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
ELECTRICAL SYSTEM
4 DSR-2019 ITEM CONTROL PANELS
5.5 Fabrication, supply, Insallation testing & commissioning of Electrical Set 1 449335.00 449335.00 0.00
control panel of cubical construction, floor mounted type, fabricated
out of 2mm thick CRCA sheet, compartmentalised with hinged
lockable doors, dust and vermin proof, powder coated of approved
shade after 7 tank treatment process, cable alley, inter-connection
with suitable size copper conductor cable/solid copper strip,
having switchgears and accessories, mountings and internal
wiring, earth terminals, numbering etc. complete in all respect,
suitable for main fire pump, pressurisation pump & diesel pump
set complete as per CPWD specification with following in coming
and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac
Supply with enclosure protection class IP 42 as required :
630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating
Digital Voltmeter 0-500V with selector switch
Ammeter (0-630 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 500Amps
( Note : All outgoing feeders for pumps should have digital
Ammeter with selector switches, and LED type ON, OFF, trip indicating
200 Amp, 50KA TPN MCCB, Ics=100% Icu, with fully automatic
Star/Delta starter suitable for 75 hp pump with overload
protection, current sensing type single phase preventor complete
with all acceessories and internal wiring required for automatic
operation, selector switch for local/remote, auto/manual/OFF
operation.- 3 sets
100 Amp, 50KA TPN MCCB, Ics=100% Icu, with Suitable HP
fully automatic Star/Delta starter with overload protection, current
sensing type single phase preventor complete with all acceessories
and internal wiring required for automatic operation, selector switch
for local/remote, auto/manual/OFF operation. - 2 sets
DIESEL ENGINE CONTROL
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempts starting device,
timers and relays as required, push buttons, start/stop in manual
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication
Battery charger suitbale for 12V/24 V DC with boost and trickle selector
switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter
All standard relays and accessories for automatic operation of
System Controller
Designing, Supply, Installation, Testing and commissioning of
system controller to control operation of main electric fire pump,
diesel pump, Pressurization pump, Terrace pump in sequence as
per specification consisting of relays, timers. Sensors,
annunciation window for fault indication, complete as per specification
5 DSR-2019 ITEM Supplying and fixing of fire brigade connection of cast iron body
NO-19 with gun metal male instantaneous inlet couplings complete with cap
and chain as reqd. for suitable dia MS pipe connection conforming
to IS 904 as required :
5.01 19.1 2 way - 100 mm dia M.S. Pipe (FOR RINGMAIN) Each 1 6590.00 6590.00 0.00
5.02 19.2 4 way-150 mm dia M.S. Pipe (FOR FIRE WATER TANK) Each 1 13822.00 13822.00 0.00
6 NON DSR-1 Providing and fixing fire brigade suction hose coupling (draw out Each 1 7452.00 0.00 7452.00
connection) with nut for female coupling as per IS-902 complete with
100mm dia. Suction pipe and foot valve (to be connected to static tank)
complete as required and as per enclosed specification. (FOR FIRE
7 DSR-2019 ITEM Providing & fixing of pressure switch in M.S. pipe line including Each 5 1508.00 7540.00 0.00
NO-22 connection etc. as required.
8 DSR-2019 ITEM Supplying and fixing single headed internal hydrant valve with Each 12 5987.00 71844.00 0.00
NO-9 instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with
cast iron wheel ISI marked conforming to IS 5290 (Type -A)
with blank Gunmetal/Stainless Steel cap and chain as required :
8.01 9.2 Single headed Stainless steel
9 DSR-2019 ITEM Supplying and fixing Single headed external yard hydrant valve with 1 Each 8 5987.00 47896.00 0.00
NO-10 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling
and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with
blank Gunmetal/Stainless Steel cap and chain as required :
9.01 10.2 Single headed Stainless steel
10 DSR-2019 ITEM Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm Each 20 1648.00 32960.00 0.00
NO-18 nominal internal diameter size nozzle conforming to IS 903
suitable for instantaneous connection to interconnect hose pipe
coupling as required :
10.01 18.2 Stainless Steel (Grade 304)
11 DSR-2019 ITEM Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm Each 40 4434.00 177360.00 0.00
NO-16 dia male and female couplings duly bound with GI wire, rivets etc.
conforming to IS 636 (type-A) as required :
11.1 16.2 Stainless Steel (Grade 304)
12 DSR-2019 ITEM Supplying and fixing first-aid Hose Reel with MS construction
NO-17 spray painted in post office red, conforming to IS 884
complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S.
Pipe and socket.
13 DSR BASED Providing and fixing angle iron (40mmx40mmx5mm) door frame and Each 12 7956.00 0.00 95472.00
MS sheet (6mm thick) cum glass shutter of size 2.1mtrx0.9mtr(N.S.)
with 25mmx25mmx3mm angle frame all around and stiffened in
between i/c hinges, handle, locking arrangement, painting with
approved synthetic enamel paint i/c sign writing on glass at internal
hydrant including providing & fixing S.S. sheet 2mm thick on remaining
portion above door to close opening i/c painting etc. as required. Glass
shall be 6 mm thick.
14 DSR BASED Providing & fixing of MS fire Hose cabinet outdoor type of size 0.90 Mx Each 8 6994.00 0.00 55952.00
0.60 Mx 0.50 M made of 6mm thick MS sheet with 6mm thick glazed
glass doors i/c necessary locking arrangement suitable to accomodate
2nos 15m long hoses, one no branch pipe, etc. and mounted on 400
mm height agle . The cabinet shall be painted with red colour shade
No. 536 of IS: 5 externally & white internally complete in all respects for
internal hydrant and as per enclosed specification.
15 NON DSR-4 Providing and fixing stainless steel standard fireman's axe with heavy Each 12 1282.00 0.00 15384.00
insulated rubber handle tested to 20000 volts as per IS : 926 complete.
16 DSR-2019 ITEM Providing laying, testing & commissioning of 'C' class heavy duty MS
NO-6 Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc. in ground including welding, excavation
& providing cement concrete blocks as supports, anticorrosive
treatment with coaltar/asphalt tape as per IS 10221, refilling the trench
etc. of following sizes complete as required.
17 DSR-2019 ITEM Providing, laying, testing & commissioning of 'C' class heavy duty MS
NO-7 pipe conforming to IS 3589/IS 1239 including Welding, fittings like
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe
on the wall/ceiling with suitable clamp/support frame and painting with
two or more coats of synthetic enamel paint
of required shade complete as required :
18 DSR-2019 ITEM Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6
NO-11 rating with bronze/gunmetal seat duly ISI marked complete with nuts,
bolts, washers, gaskets conforming to IS 13095 of following sizes as
19 DSR-2019 ITEM Supplying, fixing, testing & commissioning of double flanged sluice
NO-12 valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI
marked complete with nuts, bolts, washers, gaskets and conforming to
IS 780 of following sizes as required :
20 DSR-2019 ITEM Providing, installation, testing and commissioning of non-return
NO-14 valve of following sizes confirming to IS: 5312 complete with
rubber gasket, GI bolts, nuts, washers etc.as required :
21 DSR-2021-18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved
quality (screwed end) :
22 DSR-2019 ITEM Providing, installation, testing and commissioning of stainless steel
NO-15 Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade
304, sheet with 3 mm dia holes with stainless steel flange.
23 NON DSR-5 Providing & fixing of 25mm dia. gunmetal air release valve with all Each 3 1077.00 0.00 3231.00
fittings and forged ball valve on header complete as required and as per
enclosed specification.
24 NON DSR-6 Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) Each 25 768.00 0.00 19200.00
complete with shut off valve duly calibrated before installation
complete as required & as per enclosed specification.
25 DSR-2019 ITEM Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS Set 6 18009.00 108054.00 0.00
NO-20 sheet, 1200 mm in height with air release valve on top and flanged
connection to riser, drain arrangement with 25 mm dia gun metal
wheel valve with required accessories, pressure gauge and
paintingwith synthetic enamel paint of approved shade as required.
26 NON DSR-7 Providing and fixing reinforced neoprene rubber vibration
eliminators/expansion joints (to provide relief from stresses at pipe
flanges) suitable for upto 20 kg/cm2 pressure, complete as per
27 NON DSR-8 Providing, fixing, testing & commissioning of Air Vessel fabricated from Each 1 75404.00 0.00 75404.00
8 mm thick MS plate, 450 mm in diameter and 2 m in height with
dished ends fabricated from 8mm thick MS plate with Air release valve
with stop cock, flanged inlet connection and drain arrangement with
25mm dia valve, pressure gauge with gun metal stop cock complete
with all accessories as required and conforming to IS 4736-1968. (FOR
FIRE PUMP ROOM)
Recommended dia. : 450 mm
Height of shell : 2000 mm
Working pressure : 7 Kg/Sq.cm
Test Pressure : 10 Kg/Sq.cm
28 DSR-2018 E&M- Supplying and drawing following sizes of FRLS PVC insulated copper
1.17 conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required.
29 NON DSR-9 Providing and fixing heavy duty copper armored cables 1.1 KVA grade
including necessary support clamps at ceiling level and connection legs
complete in all respects.
29.01 Power cable 3 core 16 Sq.mm Metre 30 926.00 0.00 27780.00
29.02 Power cable 3 core 95 Sq.mm Metre 45 3836.00 0.00 172620.00
30 DSR-2018 E&M- Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop Metre 150 57.00 8550.00 0.00
5.16 earthing as requried.
31 DSR-2018 E&M- Supplying and installing following size of perforated painted with
4.1 powder coating M.S. cable trays with perforation not more than 17.5%,
in convenient sections, joined with connectors, suspended from the
ceiling with M.S. suspenders including bolts & nuts, painting suspenders
etc as required.
31.01 4.1.2 150mm width x 50mm depth x 1.6 mm thickness. Metre 40 531.00 21240.00 0.00
31.02 4.1.4 300mm width x 50mm depth x 1.6 mm thickness. Metre 30 621.00 18630.00 0.00
32 DSR-2018 E&M- Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below Metre 60 131.00 7860.00 0.00
5.9 ground as strip earth electrode, including connection/ terminating with
G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by
overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at
33 DSR-2019 ITEM Providing, fixing, testing & commissioning of installation
NO-24 control valve of cast iron body, brass/bronze working parts
comprising of water motor alarm, bronze seat clapper, clapper
arm and hydraulically driven mechanical gong bell to sound
continuous alarm when the wet riser/sprinkler system activates,
pressure gauges, emergency releases, strainer, pressure switch,
cock valve complete with drain valve and bypass, test control box,
ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of
follwing sizes as required :
34 DSR-2019 ITEM Providing & fixing flow switch in following sizes M.S. pipe including
NO-23 connection etc as required.
35 NON DSR-10 Providing, fixing, inspecting, testing of built in drain assembly with sight
glass for installation on Sprinkler System, in brass body consisting of
steel single lever ball valve for multiple test and drain functions,
including inlet connection of specified size, sight glass, connections to
the main header and line drain complete as per requirements. Product
shall suitable for min. 10 kg/cm2 working pressure and shall be UL
Listed / FM Approved.
50mm Drain size and 15mm (5.6K) Testing Orifice Set 4 11250.00 0.00 45000.00
AUTOMATIC SPRINKLER SYSTEM
36 DSR-2019 ITEM Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb
NO-21 type sprinklers of rating 68 degree centigrade with required
36.01 21.1 Pendent Sprinkler Each 262 484.00 126808.00 0.00
36.02 21.2 Upright Sprinkler Each 362 484.00 175208.00 0.00
37 DSR-2019 ITEM Supplying, installation, testing & commissioning of sprinkler
NO-25 flexible pipe (UL Listed) of stainless steel complete with 15 NPT
on reducer thread with maximum working pressure of 175 PSI test
pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male
thread to sprinkler head (Outlet) 15mm NPT female thread with
reducer, nipple, 2 side brackets, center bracket, stockbar of following
sizes complete as required.
38 DSR-2019 ITEM Providing, installation, testing & commissioning of adjustable rosette Each 10 207.00 2070.00 0.00
NO-29 plate for 15mm dia in white finish UL Listed or FM approved complete
39.00 DSR-2019 ITEM Supplying, installation, testing & commissioning of deluge valve (to be
NO-26 used for water curtains) UL listed with wet pilot basic trim assembly for
DVA with test and alarm, drip and drain valve with water motor gong
complete as required.
40.00 DSR-2019 ITEM Providing, installation, testing & commissioning of water curtain nozzle Each 42 663.00 27846.00 0.00
NO-27 15mm dia nickel chrome plated brass, BSPT, K-factor as per design
consideration complete as required.
FIRE EXTINGUISHER
41 NON DSR-11 Supply, installation, testing and commissioning ISI marked (IS:15683) Each 28 7842.00 0.00 219576.00
Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base
including valve, discharge hose of not less than 10 mm dia, 1M long and
complete in all respects including initial fill with CO2 gas conforming to
IS:307-1966 and wall suspension braket as required as per
specifications.
42 NON DSR-12 Supply, installation, testing and commissioning of 6kg ABC (Powder Each 28 3252.00 0.00 91056.00
Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with
pressure indicating gauge, internal tube, squeeze lever type valve fully
charged with ABC 90 powder (Mono Ammonium Phosphate) pressured
by Nitrogen complete in all respects including wall suspension bracket
and conforming to IS:15683 as required as per specifications.
43 NON DSR-13 Supply, installation, testing and commissioning ISI marked (IS:15683) Each 4 4504.00 0.00 18016.00
portable fire extinguisher, water (gas pressure) type capacity 9 ltr. with
gun metal cap and nozzle and complete in all respects including initial
fill and wall suspension brackets as required as per specifications. FOR
PUMP ROOM,GUARD ROOM & UTILITY BUILDING
44 NON DSR-14 Providing and fixing CO2 type fire extinguishers consisting of welded Each 2 22493.00 0.00 44986.00
M.S. cylindrical body automatic modular CO2 type extinguisher
actuated through a sprinkler head mounted on The extinguisher body
finished externally with red enamel with trolly mounted complete with
internal charge.(Capacity 22.5 Kg.) FOR PUMP ROOM & UTILITY
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
Internal Plumbing work
SI.No. DSR-2021/ NON Description of Item UNIT TOTAL QUANTITY DSR RATE NON DSR RATE DSR AMOUNT NON DSR AMOUNT
SUB HEAD - INTERNAL PLUMBING WORKS
A) SANITARY INSTALLATION
1.01 17.2 Providing and fixing white vitreous china pedestal type
water closet (European type W.C. pan) with seat and
lid, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and making
good the walls and floors wherever required.
17.2.1 W.C. pan with ISI marked white solid plastic seat and Each 2 5540.55 11081.10 0.00
1.02 17.1 Providing and fixing water closet squatting pan (Indian
type W.C. pan ) with 100 mm sand cast Iron P or S
trap, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device
(handle lever) conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and making
good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size Each 8 5781.35 46250.80 0.00
580x440 mm with integral type foot rests
1.03 17.80 Providing and fixing white vitreous china battery Each 8 7004.45 56035.60 0.00
based infrared sensor operated urinal of approx. size
610 x 390 x 370 mm having pre & post flushing with
water (250 ml & 500 ml consumption), having water
inlet from back side, including fixing to wall with
suitable brackets all as per manufacturers specification
and direction of Engineer-in-charge.
1.04 8.10 Providing and fixing stone slab with table rubbed,
edges rounded and polished, of size 75x50 cm deep
and 1.8 cm thick, fixed in urinal partitions by cutting a
chase of appropriate width with chase cutter and
embedding the stone in the chase with epoxy grout or
with cement concrete 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate 6 mm nominal size) as per
direction of Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade Sqm 3 3542.85 10628.55 0.00
1.05 18.21.2.1 Providing and fixing uplasticised PVC connection pipe Each 24 85.20 2044.80 0.00
with brass unions : 45 cm length , 15 mm nominal bore
1.06 17.7 Providing and fixing wash basin with C.I. brackets, 15
mm C.P. brass pillar taps, 32 mm C.P. brass waste of
standard pattern, including painting of fittings and
brackets, cutting and making good the walls wherever
17.7.4 White Vitreous China Flat back wash basin size Each 8 1679.60 13436.80 0.00
550x400 mm with single 15 mm C.P. brass pillar tap
1.07 17.31 Providing and fixing 600x450 mm beveled edge mirror Each 8 1411.15 11289.20 0.00
of superior glass (of approved quality) complete with 6
mm thick hard board ground fixed to wooden cleats
with C.P. brass screws and washers complete.
1.08 17.34 Providing and fixing toilet paper holder :
1.09 17.71 Providing and fixing PTMT liquid soap container 109 Each 6 146.30 877.80 0.00
mm wide, 125 mm high and 112 mm distance from
wall of standard shape with bracket of the same
materials with snap fittings of approved quality and
colour, weighing not less than 105 gms.
1.10 17.22A Providing and fixing CP Brass 32mm size bottle trap of Each 8 886.25 7090.00 0.00
approved quality & make and as per the direction of
engineer in charge.
1.11 17.72 Providing and fixing PTMT towel ring trapezoidal shape Each 6 204.70 1228.20 0.00
215 mm long, 200 mm wide with minimum distances
of 37 mm from wall face with concealed fittings
arrangement of approved quality and colour, weighing
not less than 88 gms.
1.12 NON DSR Providing and fixing Coat Hook. Each 10 786.91 0.00 7869.11
1.13 NON DSR Providing ,Fixing of straight / offset type flexible single Each 10 574.00 0.00 5740.00
body push fit type WC pan connector of with integral
single mould sealing fins made of flexible EVA body to
be fixed with manufacture supplied grease, including
rubber bush / adaptor for use with uPVC pipe as
supplied with the pan connector.
1.14 18.49 Providing and fixing C.P. brass bib cock of approved Each 2 434.20 868.40 0.00
quality conforming to IS:8931 :
1.15 17.16a Providing and fixing 8mm dia C.P./S.S. Jet with flexible Each 2 299.35 598.70 0.00
tube upto 1meter long with S.S. Triangular plate to
european type W.C. Of approved quality and make as
approved by engineer in charge.
1.16 18.51 Providing and fixing C.P. brass long body bib cock of
approved quality conforming to IS standards and
weighing not less than 690 gms.
1.17 18.53.1 Providing and fixing C.P. brass angle valve for basin Each 24 500.35 12008.40 0.00
mixer and geyser points of approved quality
conforming to IS:8931 15mm nominal bore
1.18 18.65 Providing and fixing PTMT soap Dish Holder having Each 2 96.75 193.50 0.00
length of 138mm, breadth 102mm, height of 75mm
with concealed fitting arrangements, weighing not less
1.19 17.73 Providing and fixing PTMT towel rail complete with
brackets fixed to wooden cleats with CP brass screws
with concealed fittings arrangement of approved
quality and colour.
17.73.1 450 mm long towel rail with total length of 495 mm, Each 2 573.60 1147.20 0.00
78 mm wide and effective height of 88 mm, weighing
not less than 170 gms
1.20 NON DSR Providing & Fixing of Grab bar 600 mm of non slipping Each 4 4910.00 0.00 19640.00
grip as per standard specification of use in disabled
toilet complete with brackets suitable for wall
installation as per approved sample complete in all
TOTAL FOR SANITARY INSTALLATION 184641.00 33249.00
B) WATER SUPPLY
2.01 18.8 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded
fittings, i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings with
one step CPVC solvent cement and the cost of cutting
chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making
good the walls etc.
e) Based on DSR-2021 40 mm nominal bore Mtr. 18 459.90 8094.24 0.00
2.02 18.7 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded
fittings, including fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings with
one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
2.03 NON DSR Providing and fixing Forged Brass Ball Valve (Screwed).
with setting and gland of superior quality having
minimum working pressure of 16 kg/cm2.
a) 15 mm nominal bore Each 2 593.00 0.00 1186.00
b) 20 mm nominal bore Each 2 784.00 0.00 1568.00
c) 25 mm nominal bore Each 1 1158.00 0.00 1158.00
d) 32 mm nominal bore Each 2 1903.00 0.00 3806.00
e) 40 mm nominal bore Each 4 2720.00 0.00 10880.00
2.04 18.62 Providing and fixing PTMT Ball cock of approved
quality, colour and make complete with Epoxy coated
aluminium rod with L.P./ H.P.H.D. plastic ball.
a) 18.62.4 40 mm nominal bore, 206mm long, weighing not less Each 1 653.40 653.40 0.00
2.05 18.48 Providing and placing on terrace (at all floor levels) per litre 30000 9.70 291000.00 0.00
polyethylene water storage tank, ISI : 12701 marked,
with cover and suitable locking arrangement and
making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for
2.06 NON DSR Providing & fixing Auto Air vent for cold water supply
risers, suitable for pressure not less than 15 Kg/Sq.cm.
TOTAL FOR WATER SUPPLY 417401.00 19516.00
C) INTERNAL DRAINAGE
Providing and fixing soil, waste and vent pipes
3.01 NON DSR Providing, fixing & testing uPVC SWR pipes confirming
to IS 13592 (Type B) alongwith all required fittings like
tees, bends, crosses with or without access doors
jointed with approved solvent cement as per
manufacturer's recommendations, fixed to walls and
ceilings with clamps complete including cutting and
making good the floors and walls where required
complete of outer diameter.
3.02 NON DSR Providing, fixing, jointing and testing in position the
following uPVC pipes conforming to IS 4985 of 6
kg/sqcm pressure rating including all fittings, solvent
weld joints, testing complete for drainage system cut
to required length to be laid under floor including
covering all around with cement concrete and making
good the same complete as required.
For waste pipes
(a) 40mm OD (6 kg pressure) Metre 11 381.00 0.00 4191.00
(b) 50mm OD (6 kg pressure) Metre 7 505.00 0.00 3333.00
(c) 63mm OD (6 kg pressure) Metre 13 749.00 0.00 9886.80
3.03 NON DSR Providing and Fixing 110x110 mm uPVC 'P' trap with
Height riser/Saddle as required size ftting with seal 50
mm of self cleansing design floor/urinal trap without
vent suspended with supporting clamp or in sunken
portion including cutting and making good the walls
and floors wherever required complete in all respects.
3.04 NON DSR Providing and Fixing uPVC floor drain of following
size inlet and outlet including cutting and making good
the walls and floors wherever required complete in all
3.05 NON DSR Providing and fixing 125 mm dia, 3 mm thick Stainless
steel grating with frame for floor traps or drains of
required pattern including cutting and making good
the floors complete.
3.06 NON DSR Providing & fixing PVC clean out plug with suitable
insert keys for opening in: brass cap, male threaded
joint with threaded uPVC socket fixed to uPVC pipe
joints as required complete in all respects.
TOTAL FOR DRAINAGE 0.00 215333.00
D) RAIN WATER WORK
4.01 12.41 Providing and fixing on wall face unplasticised Rigid
PVC rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes.
4.02 12.42 Providing and fixing on wall face unplasticised - PVC
moulded fittings/ accessories for unplasticised Rigid
PVC rain water pipes conforming to IS : 13592 Type A
including jointing with seal ring conforming to IS : 5382
leaving 10 mm gap for thermal expansion.
a) 12.42.2 Single Push fit coupler
b) 12.42.3 Single Tee with door
c) 12.42.5 Bend 87.5 Deg
d) 12.42.6 Shoe (Plain)
4.03 12.44 Providing and fixing to the inlet mouth of rain water Each 35 47.90 1676.50 0.00
pipe cast iron grating 15 cm diameter and weighing
not less than 440 grams.
4.04 12.43 Providing and fixing unplasticised -PVC pipe clips of
approved design to unplasticised - PVC rain water
pipes by means of 50x50x50 mm hard wood plugs,
screwed with M.S. screws of required length, including
cutting brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the wall etc.
4.05 12.22 Making khurras 45x45 cm with average minimum Each 5 266.60 1333.00 0.00
thickness of 5 cm cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate of 20 mm
nominal size) over P.V.C. sheet 1 m x1 m x 400 micron,
finished with 12 mm cement plaster 1:3 (1 cement : 3
coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
TOTAL FOR RAIN WATER WORK 186418.00 0.00
TOTAL INTERNAL PLUMBING 788460.00 268098.00
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External Plumbing Work
SI.No. DSR-2021/ NON DSR Description of Item UNIT TOTAL DSR RATE NON DSR DSR AMOUNT NON DSR
QUANTITY RATE AMOUNT
SUB HEAD - EXTERNAL PLUMBING WORKS
A) EXTERNAL WATER SUPPLY
1.01 18.12 Providing and fixing G.I. pipes complete with G.I.
fittings including trenching and refilling etc.
a) 18.12.6 50 mm nominal dia Pipes Metre 230 654.20 150466.00 0.00
b) 18.12.5 40 mm nominal dia Pipes Metre 40 558.35 22334.00 0.00
1.02 18.40 Painting G.I. pipes and fittings with two coats of anti-
corrosive bitumastic paint of approved quality :
a) 18.40.6 50 mm dia nominal bore Metre 230 25.25 5807.50 0.00
b) 18.40.5 40 mm dia nominal bore Metre 40 20.95 838.00 0.00
1.03 18.41 Providing and filling sand of grading zone V or coarser
grade alround the GI pipes in external work.
a) 18.41.6 50mm dia nominal bore Metre 230 176.90 40687.00 0.00
b) 18.41.5 40mm dia nominal bore Metre 40 170.50 6820.00 0.00
1.04 18.13 Making connection of G.I. distribution branch with
G.I. main of following sizes by providing and fixing
tee, including cutting and threading the pipe etc.
1.05 19.6 Providing and laying non-pressure NP2 class (light
duty) R.C.C. pipes with collars jointed with stiff
mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc.
a) 19.6.1 100 mm dia. R.C.C. pipe (hume pipe) Metre 10 447.25 4472.50 0.00
1.06 18.60 Providing and fixing enclosed type water meter (bulk
type) conforming to IS : 2373 and tested by Municipal
Board complete with bolts, nuts, rubber insertions
etc. (The tail pieces if required will be paid separately)
1.07 Based on DSR-E&M- Providing & fixing of following sizes of butterfly valve
2018,16.11.1 of rating PN 16, wafer type, in cast iron body with
Ductile Iron disc, EPDM seal, SS single piece shaft,
conforming to IS-13095 of the following sizes
complete with cast iron hand lever companion
flanges, bolts, nuts, washers & inserted rubber
gaskets, as required and as per enclosed specification.
1.08 18.34 Constructing masonry Chamber 90x90x100 cm inside,
in brick work in cement mortar 1:4 (1 cement : 4
coarse sand) for sluice valve, with C.I. surface box 100
mm top diameter, 160 mm bottom diameter and 180
mm deep (inside) with chained lid and RCC top slab
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size ), i/c necessary
excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal
size ) and inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per
standard design :
a) 18.34.1 With common burnt clay F.P.S.(non modular) bricks Each 1 17577.90 17577.90 0.00
of class designation 7.5
TOTAL FOR EXTERNAL SUPPLY 266344.00 0.00
B) GARDEN IRIGATION SUPPLY
2.01 18.12 Providing and fixing G.I. pipes complete with G.I.
fittings including trenching and refilling etc.
a) 18.12.6 50 mm nominal dia Pipes Metre 372 654.20 243362.40 0.00
b) 18.12.3 25 mm nominal dia Pipes Metre 11 417.95 4597.45 0.00
2.02 18.40 Painting G.I. pipes and fittings with two coats of anti-
corrosive bitumastic paint of approved quality :
a) 18.40.6 50mm dia nominal bore Metre 372 25.25 9393.00 0.00
a) 18.40.3 25mm dia nominal bore Metre 11 15.25 167.75 0.00
2.03 18.41 Providing and filling sand of grading zone V or coarser
grade alround the GI pipes in external work.
a) 18.41.6 50 mm dia nominal bore Metre 65 176.90 11498.50 0.00
2.04 19.6 Providing and laying non-pressure NP2 class (light
duty) R.C.C. pipes with collars jointed with stiff
mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc.
a) 19.6.1 100 mm dia. R.C.C. pipe (hume pipe) Metre 32 447.25 14312.00 0.00
2.05 Based on DSR-E&M- Providing & fixing of following sizes of butterfly valve
2018,16.11.1 of rating PN 16, wafer type, in cast iron body with
Ductile Iron disc, EPDM seal, SS single piece shaft,
conforming to IS-13095 of the following sizes
complete with cast iron hand lever companion
flanges, bolts, nuts, washers & inserted rubber
gaskets, as required and as per enclosed specification.
2.06 NON DSR Providing & fixing in position 25 mm dia lawn Each 11 2843.00 0.00 31273.00
hydrants consisting of 25 mm dia Ball valve, GI nipple
and threaded hose receiver complete as required.
TOTAL FOR GARDEN IRIGATION SUPPLY 285875.00 31273.00
C) EXTERNAL SEWAGE WORK
3.01 2.10 Excavating trenches of required width for pipes,
cables, etc including excavation for sockets,
anddressing of sides, ramming of bottoms, depth up
to 1.5 m, including getting out the excavated soil, and
then returning the soil as required, in layers not
exceeding 20 cm in depth, including
consolidatingeach deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil
as directed,within a lead of 50 m :
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia but not metre 77 417.35 32135.95 0.00
exceeding 300 mm dia
3.02 2.8 Earth work in excavation by mechanical means
(Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10
Sqm on plan), including dressing of sides and ramming
of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil
as directed, within a lead of 50 m.
3.03 NON DSR Supplying and laying of following size DWC SN8 pipe
ISI marked along with all accessories like socket,
bend, couplers etc. conforming to IS 16098, Part II
complete with fitting and cutting,jointing etc.direct in
ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand
cushioning and protective covering etc., complete as
3.04 19.2 Providing and laying cement concrete 1:5:10 (1
cement : 5 coarse sand : 10 graded stone aggregate
40 mm nominal size) all-round S.W. pipes including
bed concrete as per standard design :
a) 19.2.3 200 mm diameter S.W. pipe metre 77 1276.70 98305.90 0.00
3.05 19.4.1.1 Providing and fixing square-mouth S.W. gully trap Each 3 2453.55 7360.65 0.00
class SP-1 complete with C.I. grating brick masonry
chamber with water tight C.I. cover with frame of
300x300 mm size (inside) the weight of cover to be
not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design: 100x100 mm size P
type. With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
3.06 19.7 Constructing brick masonry manhole in cement
mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top
slab with 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40 mm nominal size),
inside plastering 12 mm thick with cement mortar 1:3
(1 cement : 3 coarse sand) finished with floating coat
of neat cement and making channels in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) finished with a
floating coat of neat cement complete as per
standard design :
Inside size 90x80 cm and 45 cm deep including C.I.
cover with frame (light duty) 455x610 mm internal
dimensions,total weight of cover and frame to be not
less than 38 kg (weight of cover 23 kg and weight of
19.7.1.1 With common burnt clay F.P.S.(non modular) bricks Each 2 11687.10 23374.20 0.00
of class designation 7.5
3.07 19.8 Extra for depth for manholes:
Size 90x80x90 cm
19.8.1.1 With common burnt clay F.P.S.(non modular) bricks Mtr 0.30 8127.45 2438.24 0.00
of class designation 7.5
3.08 19.9 Constructing Brick Masonry circular type manhole
0.91 m internal dia at bottom and 0.56m dia at top
with FPS bricks class designation 75 in cement
mortar 1:4 (1 cement : 4 Coarse sand), inside cement
plaster 12mm thick with cement mortar 1:3 ( 1
cement : 3 coarse sand) finished with a floating coat
of of neat cement, foundation concrete 1:3:6 mix ( 1
cement : 3 coarse sand : 6 graded stone aggregate
40mm nominal size) and making necessary channel in
Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4
Graded Stone Aggregate 20mm nominal size) finished
with a floating coat of neat cement complete as per
standard design.
19.9.1 0.91m deep with SFRC cover and frame (heavy duty
HD-20 grade designation) 560mm internal diameter
conforming to I.S:12592, total weight of cover and
frame to be not less than 182Kg. fixed in cement
concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded
stone aggregate 20mm nominal size) including
centering, shuttering all complete.(Excavation foot
rests and 12mm thick cement plaster at the external
surface shall be paid for separately)
19.9.1.1 with common burnt clay F.P.S.(non module) brick of Each 4 11886.45 47545.80 0.00
class designation 7.5
3.09 19.10 Extra depth for circuler type manholes 0.91 m internal
dia ( at bottom ) beyond 0.91m to 1.67 m .
19.10.1 with common burnt clay F.P.S.(non module) brick of Meter 0.4 6986.80 2794.72 0.00
class designation 7.5
3.08 19.16 Providing orange colour safety foot rest of minimum Each 16 487.10 7793.60 0.00
6 mm thick plastic encapsulated as per IS : 10910, on
12 mm dia steel bar conforming to IS: 1786, having
minimum cross section as 23 mmx25 mm and over all
minimum length 263 mm and width as 165 mm with
minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or
chequering besides necessary and adequate
anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend
test and chemical resistance test as per specifications
and having manufacture's permanent identification
mark to be visible even after fixing, including fixing in
manholes with 30x20x15 cm cement concrete block
1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per
3.09 13.7 12 mm cement plaster finished with a floating coat of
neat cement of mix :
TOTAL FOR EXTERNAL SEWAGE WORK 232617.00 60137.00
D) EXTERNAL STORM WATER WORK
4.01 2.10 Excavating trenches of required width for pipes,
cables, etc including excavation for sockets,
anddressing of sides, ramming of bottoms, depth up
to 1.5 m, including getting out the excavated soil, and
then returning the soil as required, in layers not
exceeding 20 cm in depth, including
consolidatingeach deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil
as directed,within a lead of 50 m :
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia but not metre 510 417.35 212848.50 0.00
exceeding 300 mm dia
2.10.1.3 Pipes, cables etc. exceeding 30 mm dia but not metre 102 651.55 66458.10 0.00
exceeding 600 mm dia
4.02 2.8 Earth work in excavation by mechanical means
(Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10
Sqm on plan), including dressing of sides and ramming
of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil
as directed, within a lead of 50 m.
4.03 19.6 Providing and laying non-pressure NP2 class (light
duty) R.C.C. pipes with collars jointed with stiff
mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc.
For storm water pipe
19.6.3 250 mm dia. R.C.C. pipe For Electrical Road Crossing metre 50 811.15 40557.50 0.00
19.6.4 300 mm dia. R.C.C. pipe For Electrical Road Crossing metre 200 902.05 180410.00 0.00
4.04 19.35 Providing and laying Non Pressure NP-3 class
(Medium duty) R.C.C. pipes including collars/spigot
jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including
testing of joints etc. complete
For storm water pipe road crossing
4.05 19.3 Providing and laying cement concrete 1:5:10 (1
cement : 5 coarse sand : 10 graded stone aggregate
40 mm nominal size) up to haunches of RCC. pipes
including bed concrete as per standard design :
d) Analysed dsr 19.3.5 450 mm dia. R.C.C. pipe metre 70 1573.20 0.00 110124.00
19.3.4 250 mm dia. R.C.C. pipe For Electrical Road Crossing metre 50 943.90 47195.00 0.00
19.3.5 300 mm dia. R.C.C. pipe For Electrical Road Crossing metre 200 1089.10 217820.00 0.00
4.06 19.2 Providing and laying cement concrete 1:5:10 (1
cement : 5 coarse sand : 10 graded stone aggregate
40 mm nominal size) all-round RCC pipes including
bed concrete as per standard design :
For Storm Water road crossing
a) Analysed dsr 19.2.4 450 mm dia. R.C.C. pipe metre 32 2141.90 0.00 68540.80
4.07 19.9 Constructing Brick Masonry circular type manhole
0.91 m internal dia at bottom and 0.56m dia at top
with FPS bricks class designation 75 in cement
mortar 1:4 (1 cement : 4 Coarse sand), inside cement
plaster 12mm thick with cement mortar 1:3 ( 1
cement : 3 coarse sand) finished with a floating coat
of of neat cement, foundation concrete 1:3:6 mix ( 1
cement : 3 coarse sand : 6 graded stone aggregate
40mm nominal size) and making necessary channel in
Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4
Graded Stone Aggregate 20mm nominal size) finished
with a floating coat of neat cement complete as per
standard design.
19.9.1 0.91m deep with SFRC cover and frame (heavy duty
HD-20 grade designation) 560mm internal diameter
conforming to I.S:12592, total weight of cover and
frame to be not less than 182Kg. fixed in cement
concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded
stone aggregate 20mm nominal size) including
centering, shuttering all complete.(Excavation foot
rests and 12mm thick cement plaster at the external
surface shall be paid for separately)
19.9.1.1 with common burnt clay F.P.S.(non module) brick of Each 21 11886.45 249615.45 0.00
class designation 7.5
4.08 19.10 Extra depth for circuler type manholes 0.91 m internal
dia ( at bottom ) beyond 0.91m to 1.67 m .
19.10.1 with common burnt clay F.P.S.(non module) brick of Meter 2.1 6986.80 14672.28 0.00
class designation 7.5
4.09 19.16 Providing orange colour safety foot rest of minimum Each 63 487.10 30687.30 0.00
6 mm thick plastic encapsulated as per IS : 10910, on
12 mm dia steel bar conforming to IS: 1786, having
minimum cross section as 23 mmx25 mm and over all
minimum length 263 mm and width as 165 mm with
minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or
chequering besides necessary and adequate
anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend
test and chemical resistance test as per specifications
and having manufacture's permanent identification
mark to be visible even after fixing, including fixing in
manholes with 30x20x15 cm cement concrete block
1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per
4.10 13.7 12 mm cement plaster finished with a floating coat of
neat cement of mix :
4.11 19.28 Constructing brick masonry road gully chamber
45x45x77.5 cm with bricks in cement mortar 1:4 (1
cement : 4 coarse sand ) with precast R.C.C. vertical
grating complete as per standard design :
19.28.1 with common burnt clay F.P.S.(non module) brick of Each 32 6258.20 200262.40 0.00
class designation 7.5
4.12 19.29 Constructing brick masonry road gully chamber
110x50x77.5 cm with bricks in cement mortar 1:4 (1
cement : 4 coarse sand) including 500x450 mm
precast R.C.C. horizontal grating with frame and
vertical grating complete as per standard design :
19.29.1 with common burnt clay F.P.S.(non module) brick of Each 11 10596.95 116566.45 0.00
class designation 7.5
4.13 19.21 Making connection of drain or sewer line with existing
manhole including breaking into and making good the
walls, floors with cement concrete 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) cement plastered on both sides
with cement mortar 1:3 (1 cement : 3 coarse sand),
finished with a floating coat of neat cement and
making necessary channels for the drain etc.
19.21.3 For pipes 350 to 450 mm diameter Each 1 1134.65 1134.65 0.00
TOTAL FOR EXTERNAL STORM WATER WORK 2542513.00 178665.00
E) RAIN WATER HARESTING PIT BOREWELL
5.01 23.1 Boring/drilling bore well of required dia for casing/
strainer pipe, by suitable method prescribed in IS:
2800 (part I), including collecting samples from
different strata, preparing and submitting strata
chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for
the job, all complete as per direction of Engineer-in-
charge, upto 90 metre depth below ground level.
Depth of Boring as per site condition
23.1.1 All types of soil
5.02 23.3 Supplying, assembling, lowering and fixing in vertical
position in bore well, unplasticized PVC medium well
casing (CM) pipe of required dia, conforming to IS:
12818, including required hire and labour charges,
fittings & accessories etc. all complete, for all depths,
as per direction of Engineer -in-charge.
23.3.3 200 mm nominal size dia Metre 60.00 951.95 57117.00 0.00
5.03 23.4 Supplying, assembling, lowering and fixing in vertical
position in bore well unplasticized PVC medium well
screen (RMS) pipes with ribs, conforming to IS: 12818,
including hire & labour charges, fittings & accessories
etc. all complete, for all depths, as per direction of
Engineer-in-charge.
23.4.3 200 mm nominal size dia Metre 90.00 1099.25 98932.50 0.00
TOTAL HARVESTING PIT BOREWELL 244857.00 0.00
TOTAL EXTERNAL PLUMBING 35,72,206.00 2,70,075.00
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
STP & WTP works
SI.No. DSR-2021/ NON DSR Description of Item UNIT TOTAL DSR RATE NON DSR DSR AMOUNT NON DSR
QUANTITY RATE AMOUNT
SUB HEAD- STP & WTP WORKS
A) WATER SUPPLY PUMPS & EQUIPMENTS
1.01 NON DSR Pumps
Supply Installation testing and commissioning of Vertical/horizontal
monoblock centrifugal transfer pumping set with SS-316 body and SS-316
impeller, SS-316 shaft mechanical seal, connected to a TEFC induction motor
suitable for 415 volts ± 3% phase 50 cycles AC supply with a common suction
header with valves on main connecting & pumps inlet and a common
delivery header with valves, includingt water shock absorber, non return
valves with MS galvanized supports and painting with one coat of primer and
two coats of synthetic enamel paint including a 100mm dia pressure gauge,
Vibration eliminating pads under foundation, all mounted on a common base
plate of MS 80x40mm I section bolted to RCC foundation, including control
panel complete in all respects.
(i) NON DSR FOR FILTER FEED PUMP
No. of Pumps: 2 (1 Working + 1 Stand by )
Capacity : 90 LPM
(ii) NON DSR FOR GARDEN IRRIGATION PUMP
No. of Pumps: 2 (1 Working + 1 Stand by )
Capacity : 70 LPM
(iii) NON DSR FOR DOMESTIC WATER SUPPLY PUMP
No. of Pumps: 2 (1 Working + 1 Stand by )
Capacity : 90 LPM
1.02 NON DSR Submersible single stage single entry pumps with C.I.body and C.I. two vane
enclosed type impeller connected to TEFC submersible motor for 415 volts, 3
phase, 50 cycles including MCC panel with level controllers, auto control,
sequential change over facility with one proper working at low level & two
proper working at high level with an audible alarm including all
interconnectivity cables, with both pumps connected to common outlet
header including valves, non return valves, lifting chains etc. complete in all
(one working + one standby/both working in high flow conditions)
PUMP ROOM SUMP PUMP
(Solid handiling capacity 10-12mm)
Capacity- 200 lpm (Each)
1.03 Providing and fixing vertical type skid mounted of required diameter. The
shell shall be fabricated from M.S. plates conforming to IS: 2041 suitable to
withstand design pressure. The minimum thickness of shell shall be 6 mm &
dished shall be 8 mm thick which shall include corrosion allowance and mill
allowance respectively. The scaling allowance on dished ends to be
considered by the bidder as per requirement of IS:2825.
a) One no. pressure tight manholes and at least one no. pressure tight side
hole for maintenance purposes.
b) Initial charge of Filter Media.
c) Complete underdrain system and raw water distributor as per
manufacturer's design.
Complete MS C Class frontal face piping conforming to IS:1239) and valves
battery with CI Butterfly valves, pressure gauges and sampling points at inlet
and outlet. etc. covering all functions of service, backwash, rinse, air release
e) Pressure gauges (100 mm dia bourdon type pressure gauge)/ sampling
points as per manufacturer design.
f) All internal parts of the filtration plant shall be coated with two coats of
epoxy paint after thorough sand blasting. All external surfaces of the plant
including piping shall be coated with two coats of red iron oxide/zinc
chromate primer followed by two coats of high gloss enamel paint .
g) The filter shall be complete with all gaskets/fasteners of standard quality as
h) The filter shall be designed to give rated output at given raw water quality
and flow rate without any operational problem and should not get any loss of
performance as long as the operating pressure remains within the given
range. Any additional provision is required to make the item complete, the
same should be included herein.
i) Filter shall be painted inside with minimum two coats of non-toxic corrosion
resistant paint and one coat of red oxide primer outside.
a) Dual Media filter
Capacity : 5400 lph
Filtration rate : 11500 lph/m
Filter dia approx. : 800 mm
Working pressure : 3.0 kg/cm
Test pressure : 4.5 kg/cm
1.04 POST CHLORINATION OF WATER
Supply Installation testing and commissioning of On line electronic chemical
solution dosing system comprising of electronic metering pump (with both
frequency and stroke length controls to control the dosage rate between 10-
100 % of rated maximum capacity), virgin HDPE chemical grade solution tank
of rquired capacity, necessary injection fitting assembly, foot valve cum
strainer and suction and delivery tubing etc. upto the point of injection
complete in all respects as required.
For Cholorination of filtered water
NON DSR Dosing capacity : 0-6 ltrs. per hour, Dosing Head : 3.5 kg/cm
1.05 NON DSR To switch on the pumps (including Raw Water Pump, Domestic water
supply pump etc.) when the level of water in the supply water tank is low
and to cut off the pump when the level in the receiving water tank is high
and switch off the pumps when the level of water in the supply water tank is
To indicate 5 levels of water in all tanks through a control panel with LEDs
To start the pumps in a cyclic order.
The system shall be complete to ensure automatic quotation of pump in
accordance to water level in respective tanks.
The Contractor will include all the under ground and over head tanks and all Set 2 13647.00 0.00 27294.00
the pumps as required for level control in this item
1.06 Based on DSR-E&M- Providing & fixing of following sizes of butterfly valve of rating PN 16, wafer
2018,16.11.1 type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft,
conforming to IS-13095 of the following sizes complete with cast iron hand
lever companion flanges, bolts, nuts, washers & inserted rubber gaskets, as
required and as per enclosed specification.
1.07 DSR-2018 E&M-1.17 Supplying and drawing following sizes of FRLS PVC insulated copper
conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required.
1.08 DSR-2018 E&M-5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop Metre 120 57.00 6840.00 0.00
earthing as requried.
1.09 DSR-2018 E&M-4.1 Supplying and installing following size of perforated painted with powder
coating M.S. cable trays with perforation not more than 17.5%, in convenient
sections, joined with connectors, suspended from the ceiling with M.S.
suspenders including bolts & nuts, painting suspenders etc as required.
a) 4.1.2 150mm width x 50mm depth x 1.6 mm thickness. Metre 30 531.00 15930.00 0.00
b) 4.1.3 200mm width x 50mm depth x 1.6 mm thickness. Metre 30 597.00 17910.00 0.00
1.10 NON DSR Design, fabrication, assembling, wiring, supply, installation, testing and
commissioning of motor control centre shall be fabricated out of 14 gauge
CRCA sheet steel in form in 3b formation with reinforcement of suitable size
angle iron, channel ‘T’ sections irons and /or flats wherever necessary. Cable
gland plates shall be provided on top as well as at the bottom of the panels.
Panels shall be treated with all anticorrosive process before painting as per
specifications with 2 coats of red oxide primer and final approved shade of
powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase,
4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of
large panels. Approval shall be taken for each panel before fabrication.
Cadmium Plated hardware shall be used in fabrication of panels. Quoted
rates shall inclusive of cables, cable trays, earthing (in accordance to
specification) with earthing from panel to each motor / equipment.
MCC for Plumbing system
2 Nos. 150A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu =
100%) with with O/L , S/C & E/F protection as per specification and with
following accessories
1 No. Digital MFM meter and 3 nos. CTs of ratio 100/5A , Class I accuracy and
10 VA burden. digital multifunction meter suitable to measure voltage,
Ampere, Frequency, Power Factor with RS-485 Port
1 Set of ON/ OFF/TRIP Indicating LED Lamps with 2 Amp MCB.
1 Set of phase indicating LED lamps with 2 amp back up MCB.
1 No. 200A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu =
100%) with with O/L , S/C & E/F protection with 1 Set of ON/ OFF Indicating
LED Lamps with 2 Amp MCB.
4P copper bus bars of 163A capacity with heat shrinkable coloured sleeves
and i/c, SMC bus bars supports at required intervals complete for cross
section, size supports & their spacing etc. for withstanding fault level of 35 KA
2 No. MPCB of 32 Amp. i/c 1.1 KW DOL starter and providing outgoing feeder
of 3 core, armoured coper cable of size of 6 Sq. mm to Filter feed pump
(including 1 No. as standby). Each compartment shall contain auto / manual
selector swtich and indicating and pushbutton lamps etc. as required.
2 No. MPCB of 32 Amp. i/c 1.1 KW DOL starter and providing outgoing feeder
of 3 core, armoured coper cable of size of 6 Sq. mm to Domestic Water
Transfer pump (including 1 No. as standby). Each compartment shall
contain auto / manual selector swtich and indicating and pushbutton lamps
etc. as required.
2 No. MPCB of 25 Amp. i/c 1.1 KW DOL starter and providing outgoing feeder
of 3 core, armoured coper cable of size of 6 Sq. mm to Sump pump (including
1 No. as standby). Each compartment shall contain auto / manual selector
swtich and indicating and pushbutton lamps etc. as required.
Spare MCCBof following capacities:
25 amps 4P MCCB 2 Nos.
Necessary cable alleys, internal wiring, and interlocking, earthing for all
equipment shall also be included.
a. All MPCBs shall be of 35 KA breaking capacity and suitable for motor duty
b. Provision shall be made to ensure system protection from dry running of
c. All incomers and Buscoupler breakers shall be electrical and mechanical
interlocked with suitable accessories.
d. 2 Nos. Type-2 SPD 65kA 4P with 1No. Red Indicator Light for SPD with
1Set. SPD Back up fuse 1P 50A 20kA including all necessary accessories.
For Plumbing System as described above. Set 1 327527.00 0.00 327527.00
TOTAL FOR WATER SUPPLY PUMPS 118392.00 1259858.00
B) STP PACKAGED TYPE 20 KLD
2.01 Design, Supply, Installation testing & commisioning of Sewerage treatment
plant in MBBR (MOOVING BED BIO REACTOR TECHNOLOGY) process with all
the required item completely for Domestic Sewege capciaty 20 cum/day.
Outlet Parameter should be match for using the water for Gardening
purpose. Bidder should include following items as specified below suitable for
20 cum/day STP. (Bidder Must visit the site before quote) Depth of
Incomming sewer 1.3m to be consider.
A The stp shall be designed based on the following parameters:
Daily average flow - 20 Cum / Day
S. Solids - 150 Mg/L
COD - 300 – 500 Mg/L
Oil & Grease -20 Mg / L
B Effluent discharge standard after treatment
BOD5 - Less than 30 Mg/L
S. Solids - 10 Mg/L
Oil & Grease - 10 Mg / L
c Sewerage treatment plant contaning following Tank and Electro Mech.
1.01 All the tanks are MSEP tanks except Equalization Tank Set
1.02 1 Nos. Stainless Steel-316 Perforated Corrugated Screen of fabricated
through 5mm thick plate having holes of 8 mm at a distance of 10 mm with Set
suitable lifting arrangement
1.03 mechanical punched hole fine screen for 2-3 mm size complete as required
1.04 Level and Measurmement Control.
1.05 sight tube (of 3.5 to 4.5 m length) with isolation valve at top/bottom
1.06 Equalization Transfer pump (1 Working +1 standby) Set
1.07 2 No. twin type rotary air blowers (1W + 1S) for Aeration Tank and Equlisation
1.08 Disc type, EPDM membrane based, non clog type air dispersion system for
Imported fine bubble membrane diffusers for equalisation tank, aeration tank
& sludge holding tank, MBBR tank,MS pipe (C Class),SS Piping ( Schedule
10),Butterfly Valve,Non-Return Valve,Ball Valve,MS Class 'B'with hot dip
galvanized puddle flange,instrument for the auto operation of System and
1.09 MBBR module immersed type with permeate Set
1.10 Automation of complete plant from raw effluent pump to permeate pump
out put with proper flow control
1.11 Tertiary treatment with multimedia filter Set
1.12 MBBR Permeate pump (1 Working +1 standby) Each
1.13 Sludge Recycling Pump (1 Working +1 standby) (Solid handling size for this
pump shall be 7-10 mm)
1.14 Hypo solution dosing pump comprising of FRP tank with inlet / outlet
1.15 Ultravoilet dis-infection unit
1.16 Basket type Centrifuge Machine 48'' with Perforated Plate-4mm thick, SS 304
Main Shaft-En 8, Base Frame-MS Channel.Basket Size: 1500 (Dia) Set
1.17 Self priming sludge Feed pump (1 Working +1 standby) Set
1.18 Electrical Panel with Cable, Earthing Set
1.19 It also include the transportation charges to the site Set
Sewerage treatment plant 20 cum/day complete following above items. Each 1 1569401.00 0.00 1569401.00
TOTAL FOR STP 0.00 1569401.00
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
A SUPPLY, LAYING AND TERMINATION OF 11KV HT CABLES
1.0 11KV HT CABLE SUPPLY
1.1 NON DSR Supply of 11kV 3Cx 240 sqmm (E) XLPE cable conforming to IS 7098 II. Mtrs 300 2,296 6,88,878
2.0 11KV HT CABLE LAYING
2.1 DSR-2018 (8.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV
Page No. 31 grade of following size direct in ground including excavation, sand cushioning,
protective covering and refilling the trench etc. as required.
2.2 DSR-2018 (8.1.2) Above 120 sq. mm and upto 400 sq. mm
3.0 TERMINATION OF H.T. CABLES
3.1 DSR-2018 (10.4) Supplying and making indoor cable end termination with heat shrinkable jointing kit
Page No. 37 complete with all accessories including lugs suitable for following size of 3 core, XLPE
aluminium conductor cable of 11 kV grade as required.
3.3 DSR-2018 (10.5) Supplying and making outdoor cable end termination with heat shrinkable jointing kit
Page No. 37 complete with all accessories including lugs suitable for following size of 3 core, XLPE
aluminium conductor cable of 11 kV grade as required.
4.0 NON DSR Supply, Erection, Testing & Commissioning of 11kV LA/GO/DO Switch complete with all
hardware fittings & accessories. Each 1 - 46,629 46,629
5.0 NON DSR Supply and Erection of 11 Meter long HT PCC Pole as per UPPCL / SEB specifications.
6.0 DSR-2018 (11.1) Erection of RCC/ PCC pole of following length in brick ballast and ramming the
Page No. 39 foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with
including excavation and refilling etc. as required.
6.1 DSR-2018 (11.1.3) Above 8.0 meter and upto 11.0 meter
7.0 NON DSR Supply, fabrication and fixing of mild steel material like channel, angles, flats, across
ametres, clamps, hardware, nut-bolts etc. as required. Kg 500 - 151 75,507
8.0 NON DSR Supply & providing stay set in H.T./L.T. line as per requirement. Set 1 - 3,789 3,789
TOTAL of SH (A) HT CABLE 2,56,181 8,51,100
B SUPPLY, LAYING AND TERMINATION OF LT CABLES
1.0 SUPPLY OF MV CABLING
The Cable and Cable Containment System specified herein, must confimetre to
technical Specifications, in addtion to the description given in respective items of BOQ,
whether explicitly specified or not. In case of contradiction between specifications and
description in BOQ, the most stringent of the condition will apply.
All the items / parts mentioned in relevant clauses of the technical specifications and
not specifically mentioned in BOQ shall be deemed to be included in the quoted rates,
unless specifically excluded.
It may be noted that Contractor will be required to carry out cable sizing based on
actual cable lengths, as per Working Drawings developed by him and after
incorporating any changes in load requirements from the tendering stage. Optimisation
must be carried out during cable sizing to reduce the cable requirement and size.
Further, Contractor must obtain Engineer's approval on the Cable SIzing Calculation.
1.1 1.1 Supply of LT Cable
Supply of multi core / single core, stranded / solid aluminum / copper conductor, XLPE
/ FRLS PVC insulated armoured, PVC outer extruded sheathed 1100V grade cables of
the following sizes confirming to IS 1554 & IS 7098 part I.
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1.1.1 NON DSR 3.5 Core, 300 Sqmm stranded Al, XLPE, Armd Cable. Mtrs 26 - 1,633 42,470
1.1.2 NON DSR 3.5 Core, 150 Sqmm stranded Al, XLPE, Armd Cable. Mtrs 126 - 833 1,04,970
1.1.3 NON DSR 3.5 Core, 120 Sqmm stranded Al, XLPE, Armd Cable. Mtrs 142 - 716 1,01,645
1.1.4 NON DSR 3.5 Core, 50 Sqmm stranded Al, XLPE, Armd Cable. Mtrs 105 - 343 35,994
1.1.5 NON DSR 4 Core, 25 Sqmm stranded Al, XLPE, Armd Cable. Mtr 290 - 224 64,816
1.1.6 NON DSR 4 Core, 16 Sqmm stranded Al, XLPE, Armd Cable. Mtr 368 - 171 62,983
1.1.7 NON DSR 4 Core, 10 Sqmm stranded Al, XLPE, Armd Cable. Mtr 675 - 145 97,858
1.1.8 NON DSR 4 Core, 6 Sqmm stranded Al, XLPE, Armd Cable. Mtr 75 - 123 9,250
1.1.9 NON DSR 4 Core, 6 Sqmm stranded Cu, PVC, Armd Cable. Mtr 285 - 344 97,986
1.1.10 NON DSR 3 Core, 6 Sqmm stranded Cu, PVC, Armd Cable. Mtr 90 - 255 22,924
1.1.11 NON DSR 4 Core, 4 Sqmm stranded Cu, PVC, Armd Cable. Mtr 152 - 236 35,885
1.1.12 NON DSR 3 Core, 4 Sqmm stranded Cu, PVC, Armd Cable. Mtr 105 - 182 19,134
1.1.13 NON DSR 3 Core, 2.5 Sqmm stranded Cu, PVC, Armd Cable. Mtr 2800 - 110 3,08,674
1.1.14 NON DSR 1 Core, 16 Sqmm stranded Cu, Flexible Cable. Mtr 85 - 211 17,971
1.2 Laying of LT Cable
1.2.1 DSR-2018 (7.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV
Page No. 29 grade of following size direct in ground including excavation, sand cushioning,
protective covering and refilling the trench etc. as required.
a) DSR-2018 (7.1.1) Upto 35 sq. mm
b) DSR-2018 (7.1.2) Above 35 sq. mm and upto 95 sq. mm
1.2.2 DSR-2018 (7.5) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV
Page No. 29 grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) DSR-2018 (7.5.1) Upto 35 sq. mm
b) DSR-2018 (7.5.3) Above 95 sq. mm and upto 185 sq. mm
c) DSR-2018 (7.5.4) Above 185 sq. mm and upto 400 sq. mm
1.2.3 DSR-2018 (7.8) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of
Page No. 30 1.1 kV grade of following size on cable tray as required.
a) DSR-2018 (7.8.1) Upto 35 sq. mm (clamped with 1mm thick saddle)
1.2.4 DSR-2018 (7.9) Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2
Page No. 30 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at
the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription
duly engraved as required. Each 42 530 22,260 -
1.2.5 DSR-2018 (7.10) Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate
Page No. 30 with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm
long and fixing the same in ground as required. Each 42 383 16,086 -
1.3 Terminations of LT Cable
DSR-2018 (9.1) Supplying and making end termination with brass compression gland and aluminium
Page No. 33 lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 kV grade as required.
1.3.1 DSR-2018 (9.1.22) 3.5 Core, 50 Sqmm stranded Al, XLPE, Armd Cable. Sets 2 329 658 -
1.3.2 DSR-2018 (9.1.25) 3.5 Core, 120 Sqmm stranded Al, XLPE, Armd Cable. Sets 10 489 4,890 -
1.3.3 DSR-2018 (9.1.26) 3.5 Core, 150 Sqmm stranded Al, XLPE, Armd Cable. Sets 12 555 6,660 -
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1.3.4 DSR-2018 (9.1.30) 3.5 Core, 300 Sqmm stranded Al, XLPE, Armd Cable. Sets 2 936 1,872 -
1.3.5 DSR-2018 (9.1.33) 4 Core, 16 Sqmm stranded Al, XLPE, Armd Cable. Sets 10 250 2,500 -
1.3.6 DSR-2018 (9.1.34) 4 Core, 25 Sqmm stranded Al, XLPE, Armd Cable. Sets 6 250 1,500 -
1.3.7 DSR-2018 (9.1.32) 4 Core, 10 Sqmm stranded Al, XLPE, Armd Cable. Sets 38 219 8,322 -
1.3.8 NON DSR 4 Core, 6 Sqmm stranded Al, XLPE, Armd Cable. Sets 4 - 517 2,067
1.3.9 NON DSR 4 Core, 6 Sqmm stranded Cu, PVC, Armd Cable. Sets 4 - 562 2,247
1.3.10 NON DSR 3 Core, 6 Sqmm stranded Cu, PVC, Armd Cable. Sets 2 - 562 1,123
1.3.11 NON DSR 4 Core, 4 Sqmm stranded Cu, PVC, Armd Cable. Sets 6 - 513 3,076
1.3.12 NON DSR 3 Core, 4 Sqmm stranded Cu, PVC, Armd Cable. Sets 6 - 460 2,758
1.3.13 NON DSR 3 Core, 2.5 Sqmm stranded Cu, PVC, Armd Cable. Sets 290 - 432 1,25,236
1.3.14 NON DSR 1 Core, 16 Sqmm stranded Cu, Flexible Cable. Sets 16 - 98 1,568
1.4 DSR-2021 (19.7) Constructing brick masonry manhole in cemtn mortar 1:4 (1 cement : 4 coarse sand)
Page No. 439 with R.C.C. top slab with 1:1 5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded
stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering
12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating
coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement complete as per standard design:
1.4.1 DSR-2021 (19.7.1) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
Page No. 439 455x610 mm internal dimeter, total weight of cover and frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg):
1.4.1.1 DSR-2021 (19.7.1.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1.4.2 DSR-2021 (19.7.2) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty)
Page No. 439 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg
(weight of cover 58 kg and weight of frame 58 kg):
1.4.2.1 DSR-2021 (19.7.2.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1.4.3 DSR-2021 (19.8) Extra for depth for manholes:
1.4.3.1a DSR-2021 (19.8.1.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1.4.4.1 DSR-2021 (19.8.2.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
TOTAL of SH (B) LT CABLES 9,54,772 11,60,635
C CABLE TRAY, BENDS AND TEES
1.0 CABLE TRAY
Supplying and installing following size of perforated painted with powder coating M.S.
cable trays with perforation not more than 17.5%, in convenient sections, joined with
connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts,
painting suspenders etc. as required.
1.1 NON DSR 50 mm width X 25 mm depth X 1.6 mm thickness Mtrs 31 - 363 11,252
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1.2 DSR-2018 (4.1.2) 150 mm width X 50 mm depth X 1.6 mm thickness
1.3 DSR-2018 (4.1.4) 300 mm width X 50 mm depth X 1.6 mm thickness
1.4 DSR-2018 (4.1.6) 450 mm width X 50 mm depth X 2.0 mm thickness
1.5 DSR-2018 (4.1.7) 600 mm width X 50 mm depth X 2.0 mm thickness
2.0 CABLE TRAY BENDS
Supplying and installing following size of perforated painted with powder coating M.S.
cable trays bends with perforation not more than 17.5%,, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
2.1 NON DSR 50 mm width X 50 mm depth X 1.6 mm thickness Each 2 - 672 1,343
2.3 DSR-2018 (4.2.2) 150 mm width X 50 mm depth X 1.6 mm thickness
2.4 DSR-2018 (4.2.4) 300 mm width X 50 mm depth X 1.6 mm thickness
2.5 DSR-2018 (4.2.6) 450 mm width X 50 mm depth X 2.0 mm thickness
3.0 CABLE TRAY TEE
Supplying and installing following size of perforated painted with powder coating M.S.
cable trays Tee with perforation not more than 17.5%, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
3.1 NON DSR 50 mm width X 50 mm depth X 1.6 mm thickness Each 1 - 811 811
3.3 DSR-2018 (4.3.2) 150 mm width X 50 mm depth X 1.6 mm thickness
3.4 DSR-2018 (4.3.4) 300 mm width X 50 mm depth X 1.6 mm thickness
3.5 DSR-2018 (4.3.6) 450 mm width X 50 mm depth X 2.0 mm thickness
4.0 CABLE TRAY REDUCER
Supplying and installing following size of perforated painted with powder coating M.S.
cable trays Reducer with perforation not more than 17.5%, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc. as required.
4.1 NON DSR 50 mm width X 50 mm depth X 1.6 mm thickness Each 2 - 625 1,251
4.3 DSR-2018 (4.5.2) 150 mm width X 50 mm depth X 1.6 mm thickness
4.4 DSR-2018 (4.5.4) 300 mm width X 50 mm depth X 1.6 mm thickness
4.5 DSR-2018 (4.5.6) 450 mm width X 50 mm depth X 2.0 mm thickness
4.6 DSR-2018 (4.5.7) 600 mm width X 50 mm depth X 2.0 mm thickness
5.0 CABLE TRAY SUPPORTS
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
NON DSR Supply, installation of hangers and supports for cable tray, cable tray of various width in
one/two/three or five tier fashion either on one side of the wall or on two sides of the
wall/column/truss or at other places as required as per drawing. The work involve
fabrication of clamps, hooks, suspension rod or strip painted with two coats of red
oxide and one coat afterward with paint as per the approved colour. Before
fabricating, the contractor has to get the design approved. In this, item shall be
inclusive of square section, channel, angle etc. Kgs 3500 - 172 6,02,734
TOTAL of SH (C) CABLE TRAY, BENDS AND TEES 2,74,791 6,17,391
D MAIN LT PANEL & SUB DISTRIBUTION PANELS
1.0 NON DSR LT ISOLATOR PANEL (OUTDOOR TYPE) (IP-55) (Ics = 25kA)
Supply, installation, testing & commissioning of LT Isolator panels (Outdoor type).
These will be floor mounted, free standing, outdoor duty in IP-55 enclosure, dust proof,
vermin proof, front operated, electrical panel fabricated as per specifications laid in
this document and will be complete with the main and auxiliary bus bars,
interconnection, earth bus and will be powder coated finish with 70 micron thickness.
The Panel will be made as per detailed specifications & drawings forming part of this
document. There should be double door throughout for all chambers with canopy of
not less than 1.2mm thickness.
1 No. 400A TPN incomer feeder comprising 1 no. 400A FP MCCB with microprocessor
based O/C, S/C & E/F release and ON/OFF indications. Suitable links shall be provided
for min 2Rx3.5cx240 Sq.mm AL XLPE Armoured power cables for both incoming &
outgoing. Incomer shall have following.
1 No. digital multifunction meter (Elite-444 or equivalent) with harmonics
communicating on modbus & RS 485 port with matching cast resin CT's of class 0.5.
3 nos. indicating lights for ON/ OFF/ TRIP position.
1 No. 0-500V 96 sqmm digital voltmeter with selector switch, 3 Nos. phase indicating
lamps to show the incoming power with control MCB.
Other items such as
1 Lot of control wiring.
1 Set of designation plates. No 1 - 99,432 99,432
2.0 NON DSR MAIN LT PANEL
Supply, installation, testing & commissioning of Main LT Panel. This will be floor
mounted, free standing, indoor duty, dust proof, vermin proof, front operated,
electrical panel fabricated as per specifications laid in this document and will be
complete with the main and auxiliary bus bars, interconnection, earth bus and will be
powder coated finish with 70 micron thickness. The Main LT Panel shall use all draw
out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system.
Each incoming & outgoing breaker will have microprocessor based releases. The Panel
will be made as per detailed specifications & drawings forming part of this document.
(Each MCCB will have variable current setting for over current and short circuit, front
extended lockable handle, pad lockable in off position, indication light for ON,
shrouding on incomer side, termination shall be suitable for aluminium bus bars.)
2.1 Main LT Panel Expandable Type (Ics = 25kA)
Incomers:- Three numbers (1x800A FP EDO ACB uP based from Trafo + 1x200A FP
MCCB µP based from 100kVA DG).
2.1a Incomer :- One number (1x800A, 4P EDO ACB from transformer)
One no. (1X800A 4P EDO ACB) with microprocessor based over current, short circuit &
earth fault release. ACB releases shall have over current different time settings, short
ckt. release with variable setting, short time delay, instantaneous current setting, earth
fault release, earth fault time delay. Suitable links shall be provided for min.
3Rx3.5x300 Sq.mm AL XLPE Arm cables. Incomer shall have following.
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1No. digital multifunction meter (showing harmonics along with all other electrical
parameters such as voltage current, KW, KWHr, PF.) with RS 485 port with matching
cast resin CT's.
1No. 0-500V 96 sqmm digital voltmeter with selector switch.
3Nos. Phase indicating lamps to show the incoming power with control MCB.
1No. ON/OFF indication.
1No. 3 phase voltage monitoring relay cum phase sequence meter
1No. 800/400/5A CT of Class.05.
2.1b Incomer:- One number (1x200A, 4P MCCB from DG)
1No. 200A TPN incomer feeder comprising 1no. 200A FP MCCB with µP based O/C, S/C
& E/F release and ON/OFF indications.
1No. digital multifunction meter (showing harmonics along with all other electrical
parameters such as voltage current, KW, KWHr, PF.) with RS 485 port with matching
cast resin CT's.
1No. 0-500V 96 sqmm digital voltmeter with selector switch.
3Nos. Phase indicating lamps to show the incoming power with control MCB.
1No. 3 phase voltage monitoring relay cum phase sequence meter.
1No. ON/OFF indication.
1No. RPR relay with 1no. 120/5A cast resin CT of class 0.5
2.1c Bus Coupler
1 No. number 400A 4 Pole MCCB with thermal magnetic based over current and short
circuit release as bus coupler. Necessary interlocking both electrical & mechanical shall
be done between all incomer feeders and buscoupler.
A Set of TPN Aluminium bus bar rated for 500A (after considering all necessary
deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for
calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere
given in the BOQ The conductivity of bus bar shall not be less than 57% and earth bus
size shall be be as per bus fault level of panel.
A Set of TPN Aluminium bus bar rated for 800A (after considering all necessary
deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for
calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere
given in the BOQ The conductivity of bus bar shall not be less than 57% and earth bus
size shall be as per bus fault level of panel.
(Under no case temperature of main LT panel shall be more at any point of the panel.
To avoid heating necessary exhaust fans shall have to be provided along with top
2.3 Outgoings:-
Outgoing on First Bus Bar
2Nos. 100A TPN feeders. Each having 1no. 100A TP MCCB with isolable neutral &
ON/OFF indication with thermal magnetic based release, 1no. digital multifunction
meter with RS 485 port and matching cast resin CT's.
1No. 100A TPN feeder having 1no. 100A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release.
3Nos. 63A TPN feeders. Each having 1no. 63A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release.
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1No. 40A TPN feeder having 1no. 40A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release, 1no. digital kWHr meter with RS 485
port and matching cast resin CT's.
2Nos. 40A TPN feeders. Each having 1no. 40A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release.
1 No. fabrication compartment space for 100A MCCB.
Outgoing on Second Bus Bar
2Nos. 400A TPN feeders. Each having 1no. 400A TP MCCB with isolable neutral &
ON/OFF indication with thermal magnetic based release, 1no. digital multifunction
meter with RS 485 port and matching cast resin CT's.
1No. 400A TPN feeder having 1no. 400A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release, 1no. digital multifunction meter with
RS 485 port and matching cast resin CT's. Feeder shall be tapped from trafo incomer
- 1No. 160A TPN feeder having 1no. 160A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release, 1no. digital multifunction meter with
RS 485 port and matching cast resin CT's.
- 1No. 160A TPN feeder having 1no. 160A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release.
- 1No. 125A TPN feeder having 1no. 125A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release, 1no. digital multifunction meter with
RS 485 port and matching cast resin CT's.
- 1No. 63A TPN feeder having 1no. 63A TP MCCB with isolable neutral & ON/OFF
indication with thermal magnetic based release.
2 Nos. fabrication compartment space for 100A MCCB.
- 1No. 4 mode MOV type phase to neutral & neutral to earth type 1+2 surge suppresor
(25kA) with HRC fuses (HRC fuses as per manufacturer recommendation). SPD shall
withstand 440V for 2 hrs.
- Other items such as
- Interlocking logic between two incomers and 1no. bus coupler through PLC.
- 1 Lot of control wiring
- 1 Set of designation plates No 1 - 6,29,256 6,29,256
3.0 MDB / PDB / PANEL
Supply, installation, testing commissioning of PDB’s / MDB's. These will be floor
mounted, free standing, indoor duty, dust & vermin proof, front operated, having front
hinged lockable doors, electrical panel fabricated as per specifications laid in this
document and will be complete with the main and auxiliaries bus bars,
interconnection, earth terminals, earth bus and will be powder coated finished with 70
micron. The PDB & MDB panel shall use all for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire
supply system. The panels will be made as per detailed specifications and drawings
forming part of this document. The incoming and outgoing for different PDBs shall be
- (Each MCCB will be variable current setting for over current and short circuit, front
extended lockable handle, pad lockable in off position, indication light for ON,
shrouding on incomer side, termination shall be suitable for aluminium bus bars.)
- Bus bar shall be of Aluminium and continuous throughout the width of the panel and
vertical cross section of bus bar shall be equal to the total ratings of feeders fed by the
vertical bus bars subjected to minimum size being used as per fault level. Bus bar shall
have minimum conductivity of 58%.
3.1 NON DSR PANEL (L+P)-1 (WAREHOUSE) (Ics = 10kA)
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
- 1No. Incomer 125A FP MCCB with microprocessor based releases for O/C, S/C, 3 Nos.
phase indicating lamps to show the incoming power with control MCB, 1no. ON/OFF
indication, 1no. voltmeter, voltage selector switch, 1no. KWHr Meter and matching
cast resin CT's.
- A Set of TPN Aluminium bus bar rated for 150A (after considering all necessary
deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for
calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere
given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus
size shall be as per bus fault level of panel.
- The outgoing feeders are as follows :
- 2Nos. 63A TPN feeders. Each having 1no. 63A TP MCCB with isolable neutral.
- 2Nos. 63A 4P feeders. Each having 1no. 63A 4P MCB (Curve `C').
- 5Nos. 40A 4P feeders. Each having 1no. 40A 4P MCB (Curve `C').
- 2Nos. 40A DP feeders. Each having 1no. 40A DP MCB (Curve `C').
- 1 set of complete wiring No 1 - 1,00,757 1,00,757
4.0 NON DSR FEEDER PILLAR (OUTDOOR TYPE) IP 65
Supply, Installation, testing & commissioning of Outdoor type feeder pillar with epoxy
paint and locking arrangement. This panel shall be mounting on concrete /mesonary
pedestal upto 400mm high from finished floor level, compartmentalized, cubical, dust,
vermin proof and outdoor type (IP65) fabricated as per specification laid in document
with following incoming and outgoing feeders including making connections / inter-
connections with lugs / glands crimping tools testing and earthing etc. required.
4.1 Feeder Pillar - 1 (Ics = 10kA)
- 1No. Incomer 100A FP MCCB with microprocessor based releases for O/C, S/C, 3Nos.
phase indicating lamps to show the incoming power with control MCB, 1no. ON/OFF
indication, 1 no. voltmeter, voltage selector switch, 1no. ammeter, ammeter with
selector switch and matching cast resin CT's.
- A Set of TPN Aluminium bus bar rated for 150A (after considering all necessary
deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for
calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere
given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus
size shall be as per bus fault level of panel.
- The outgoing feeders as follow:
- 1No. 40A TPN feeder having 1no. 40A TP MCCB's with isolable neutral.
3Nos. 40A FP MCB (Curve 'C')
1No. 63A 4P feeder followed by: (Please refer SLD also)
1No. Incomer 63A 4P RCBO followed by 70A FP Contactor with Digital Synchronising
timer with all accessories complete in everyway & outgoing shall be followed.
A Set of TPN Alm. bus bar rated for 100A (after considering all necessary deratings) 3
phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of
bus bar sizes. The conductivity of bus bar shall not be less than 58% and earth bus size
shall be as per fault level.
- 7Nos. 10A FP MCB (Curve 'C')
- 1 Set of complete wiring No 1 - 1,39,305 1,39,305
5.0 NON DSR CHANGEOVER PANEL (FIRE FIGHTING)
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
Supply, unloading, installation, testing & commissioning of ON load change over switch
panel. This will be indoor duty, dust proof, vermin proof, front operated, electrical
panel fabricated as per specifications laid in this document and will be complete with
incoming & outgoning terminals suitable for XLPE arm cables. cable and will be powder
coated finish with 70 micron thickness. The Panel shall use on 400A 4P On Load
Change Over Switch suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply
system. Each incomer shall have three sets of 3 indicating lights for incoming power, 1
Voltmeter 0-500 V with voltmeter selector switch & outgoing shall have ammeter with
selector switch along with suitable links on input and output side. All cable entry and
exit shall be from top.
- 1 set of complete wiring No 1 - 73,991 73,991
6.0 NON DSR 80kVAr Capacitor Panel (Ics = 25kA) (Expandable Type)
80 kVAr CAPACITOR PANEL SHALL HAVE (2x5kVAr+4x10kVAr+2x15kVAr). THESE
CAPACITOR VALUES SHALL BE DERATED FROM 440V TO 415V.
Supply, testing & commissioning of 80kVAr at 415V capacitor panel having 1 no.
incomer 400 Amps TPN isolator as incomer. Incomer to have 3 control fuses,
3indicating lights for incoming power, 1no. Volt meter 0-500 V, 96 sqmm with volt
meter selector switch, 1no. auto manual selector switch, 3 Nos. of CT's, PF meter and
1no. APFCR (14 steps) with display of all parametrs and suitable 15 VA CT’s. Each
vertical feeder will have minimum 800 cfm fan for forced cooling and necessary louvers
will be provided only at bottom.
A Set of TPN Aluminium bus bar rated for 500A (after considering all necessary
deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for
calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere
given in the BOQ. The conductivity of bus bar shall not be less than 58% and earth bus
size shall be as per bus fault level of panel.
- 2nos. x 5kVAr capacitor banks. Each 5kVAr section will have 32A magnetic type TP
MCCB with 1no of 32A TP contactor, 1no. heavy duty 5.6kVAr (at 440V) capacitor with
hot spot temperature. of 80 degree C, 1 set lights ON/OFF, 1 set of ON/OFF push
buttons, 1no. CT operated ammeter 0-50A.
- 4nos. x 10kVAr capacitor banks. Each 10kVAr section will have 63A magnetic type TP
MCCB with 1no of 70A TP contactor, 1no. heavy duty 11.2kVAr (at 440V) capacitor with
hot spot temperature. of 80 degree C, 1 set lights ON/OFF, 1 set of ON/OFF push
buttons, 1no. CT operated ammeter 0-50 amps.
- 2nos. x 15kVAr capacitor banks. Each 15kVAr section will have 63A magnetic type TP
MCCB with 1no of 70A TP contactor, 1no. heavy duty 16.8kVAr (at 440V) capacitor with
hot spot temperature. of 80 degree C, 1 set lights ON/OFF, 1 set of ON/OFF push
buttons, 1no. CT operated ammeter 0-50 amps.
Each capacitor bank shall be able to operate in either manual or auto mode individually
through APCR relay and separately in auto mode.
- 1 set of complete wiring No 1 - 2,17,197 2,17,197
TOTAL of SH (D) MAIN LT PANEL & SUB DISTRIBUTION PANELS - 12,59,937
1.1 DSR-2018 (5.2) Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and
Page No. 26 providing masonry enclosure with cover plate having locking arrangement and
watering pipe etc. with charcoal / coke and salt as required. Each 11 5,308 58,388 -
1.2 DSR-2018 (5.4) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,
Page No. 26 and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
1.3 DSR-2018 (5.6) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories,
Page No. 26 and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
1.4 NON DSR Supply and laying, testing and commissioning of copper / GI Strips / wire for
interconnecting the earthing stations to panels, DB's etc. of the following sizes in built
up trenches / surface / wall / ground complete with holes and fixing jointing /
temetreinating accessories as per specifications and drawing as required (Quality shall
be paid as per the approved drawings as executed).
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
a 50 x 6 mm thick GI strip Each 224 - 404 90,503
b 40 x 5 mm thick GI strip Each 20 - 340 6,809
c 25 x 6 mm thick GI strip Each 450 - 225 1,01,339
d 25 x 6 mm thick Cu strip Each 30 - 1,881 56,432
1.5 DSR-2018 (5.7) Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor
Page No. 26 earth electrode, including connection/ termination with GI thimble etc. as required.
1.5.1 DSR-2018 (5.16) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as
Page No. 27 required. Metre 30 57 1,710 -
1.5.2 NON DSR Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for
connections etc. as required. Metre 30 - 3,161 94,821
TOTAL of SH (F) Earthing 2,29,498 3,49,904
F LIGHTNING PROTECTION SYSTEM AS PER IEC62305
1.1 NON DSR Supply, instalation, testing & commissioning of 8mm dia aluminium solid round
conductor for height of building. Supply of 8mm Aluminum solid round conductor to
meet the requirements of IS / IEC 62305 and IEC 62561-2. Mtrs 578 - 177 1,02,473
1.2 NON DSR Supply, instalation, testing & commissioning of stainless steel or polyamide with steel
base parapet conductor holder at every one metre at every one metre for for 8-10mm
aluminium solid round conductor above concrete parapet with fixing screws meet the
requirements of IS / IEC 62305. Tested for electrical, mechanical and chemical as per as
1.3 NON DSR Supply, instalation, testing & commissioning of stainless steel or polyamide with steel
base metal roof conductor holder at every one metre for 8-10mm aluminium solid
round conductor for horizontal air terminal above metal sheet with fixing screws meet
the requirements of IS / IEC 62305. Tested for electrical, mechanical and chemical as
1.4 NON DSR Supply, instalation, testing & commissioning of stainless steel cross connector for 8mm
solid round aluminium conductor to meet the requirements of IS/IEC 62305. Tested for
electrical, mechanical and chemical as per IEC 62561. Nos 23 - 335 7,733
1.5 NON DSR Supply, installation, testing & commissioning of vertical air terminal 1mtr with rigid
mounting accessories on metal sheet to meet the requirment for IS/IEC62305. Nos 4 - 925 4,070
1.6 NON DSR Supply, instalation, testing & commissioning of expansion piece to compensate the
expansion and contraction of solid round aluminium conductor during temperature
variations to be provided on conductor length over 20 meters with expansion piece
connector to connect solid round aluminium conductor at both ends to meet the
requirements of IS/IEC 62305. Nos 31 - 307 9,458
1.7 NON DSR Supply, instalation, testing & commissioning of aluminium ferrule for connecting
expansion piece at both ends to meets the requirement of IS / IEC 62305. Tested for
electrical, mechanical and chemical as per IEC 62561. Nos 62 - 69 4,264
1.8 NON DSR Supply, instalation, testing & commissioning of 8mm dia aluminium solid round
conductor for height of building. Supply of 8mm aluminum solid round conductor to
meet the requirements of IS/IEC 62305 and IEC 62561-2 Tested for electrical,
mechanical and chemical as per IEC 62561. (Only for LCD). Mtrs 158 - 177 28,107
1.9 NON DSR Supply, instalation, testing & commissioning of stainless steel metal roof conductor
holder for 8-10mm aluminium solid round conductor for horizontal air terminal above
metal sheet with fixing screws meet the requirements of IS/ IEC 62305. Tested for
electrical, mechanical and chemical as per as per IEC 62561-2. Nos 106 - 164 17,276
1.10 NON DSR Supply, instalation, testing & commissioning of stainless steel conductor holder or
polyamide with steel base for fixing the (wall) down conductor after test joint for
holding 8-10mm solid conductor to meet the requirement of IS/IEC - 62305. Nos 53 - 199 10,499
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1.11 NON DSR Supply, instalation, testing & commissioning of bridging 16 sqmm Cu cable insulated
with heat shrink sleeve (1.0Mtrs length) with connecting accessories for connecting
8mm dia aluminium conductor in a metal building to meet the requirement of IS/IEC
1.12 NON DSR Supply, instalation, testing & commissioning of bridging 16 sqmm Cu cable insulated
with heat shrink sleeve (1.5Mtrs length) with connecting accessories for connecting
8mm dia aluminium conductor in a metal building to meet the requirement of IS/IEC
1.13 NON DSR Supply, instalation, testing & commissioning of test joint round to round suitable
connector for 8 mm round aluminium conductor & 10 mm round copper coated
conductor with polycarbonate enclosure to meet the requirement of IS/IEC - 62305.
Tested for electrical, mechanical and chemical as per IEC 62561. Nos 13 - 629 8,306
1.14 NON DSR Supply, instalation, testing & commissioning of lightnig counter-LCD screen shows the
number of lightning strikes, hour and date of lightning events. Buttons enable
TIME/DATE setting and log viewing. Replaceable battery, working life minimum five
years, complies with IEC/EN 62561-6. No 1 - 42,913 47,205
EARTHING SYSTEM IN SOIL
1.15 NON DSR Supply, instalation, testing & commissioning of 10mm minimum 250 micron copper
bonded round steel solid conductor for ring earthing meet the requirements of IS / IEC
1.16 NON DSR Supply, installation, testing & commissioning of 10 feet. UL listed MS rod of 14mm dia
copper bonded with 250 micron steel. The earthing rod shall be interconnected to grid
mesh with in soil exothermic welding. The work involves digging pit in the soil,
connecting earthing rod to stud / clamp, interconnecting further from clamp to
earthing mesh (appx distance 1.5 mtr) with appropriate exothermic welding. Earthing
grid on periphery is laid by copper bonded conductor & exothermic welding from
earthing rod to earth grid / mesh shall have similar material. Nos 4 - 8,073 35,521
1.17 NON DSR Supply,Installation,testing & commissioning of UL listed exothermic welding Joint: T-
Joint, L-Joint / Straight Joint / X-Joint. Nos 44 - 629 27,686
TOTAL of SH (F) Lighting Protection as per IEC62305 - 6,45,219
G SUB STATION SAFETY EQUIPMENTS
1.0 Supply and erection of the following equipment at suitable place in the sub-station
building as required and as per detailed specifications.
1.1 NON DSR Carbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming
to IS 2876 with cylinders fully charged of capacity 9.0 Kgm). Nos 1 - 8,132 8,132
1.2 NON DSR G.I buckets of followings capacity paint and written with white paint Fire and mounted
on M.S. angle iron bracket of sizes 50 mm x 50 mm x 6 mm thick and 500 mm long
including grouting in wall etc. as required including filling with dry sand 9 ltr capacity.
1.3 NON DSR First aid box as approved by St. John Ambulance Brigade/Indian Red Cross Conforming
1.4 NON DSR Shock treatment chart at least in three languages duly mounted ona wooden frame
with glass as required. Nos 1 - 1,711 1,711
1.5 NON DSR Rubber mat 1000 mm wide and 2.5mm thick to withstand 1.1 KV dielectric strength as
per IS 15652-2006. ammended IS. Mtrs 16 - 1,169 18,704
1.6 NON DSR Rubber mat 1000 mm wide and conforming to IS15652-2006 withstand 11 KV dielectric
strength. Mtrs 2 - 947 1,893
1.7 NON DSR Providing Single Line Diagram on 5mm thick Aluminium sheet in A0 Size duly laminated.
1.8 NON DSR Providing Single Line Diagram on 5mm thick Aluminium sheet in A1 Size duly laminated.
1.9 NON DSR Supplying of Rubber hand gloves suitable for 11 kV. Pair 1 - 1,255 1,255
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1.10 DSR-2018 (2.21) Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel,
Page No. 14 at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in
single red colour on front side as required. Nos 2 226 452 -
1.11 DSR-2018 (2.22) Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel,
Page No. 14 at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in
single red colour on front side as required. Nos 2 244 488 -
Total of SH (G) Substation equipments 940 44,810
H EXTERNAL LIGHTING
1 NON DSR SINGLE ARM STREET LIGHTING POLE (9.5 Mtr.)
Supply, installation, wiring, connection, testing and commissioning of external
boundary lighting system conforming to the technical specifications & drawings
forming part of this document. The work for each light point comprises of: - of 9.5
meter long MS tubular pole. Weighing 129Kgs (as per IS 2713 1980 of pole code 410 SP
35) + end bracket wt.5Kg. / mtr. + base plate 300x300x10mm plate Wt 4.3Kg. + Nipple
Wt. 800gm. Fixture will come at top of the pole along with reducer.
- Providing weather proof electrical junction box on surface.
- Digging for making foundation of the pole.
- Erecting the pole by grouting in concrete foundation (The civil construction materials
are the part of the supply against this assignment) made out of 1:3:6: mixture of
cement concrete.
- Supply of weather proof MS junction box of 250mm x 200mm with 1A DP MCB and
arrangement for terminating incoming and outgoing three phase cable.
- Mounting the street light fixture or approved equal on the pole top.
- Connecting the fixture by using 3Cx 2.5mm PVC flexible copper wires of colour green,
red and black to the junction box.
- Testing the connections and completing the installation.
- Providing two numbers 38 mm GI Pipe for incoming and outgoing cables from cable
laying depth to outside foundation.
- Painting the pole with 2 coats of red oxide and 2 coats of aluminium paint.
- The incoming cable work, out going cable work and the earthing of poles are covered
under the cabling and earthing. Nos 14 - 29,806 4,17,278
2 NON DSR POLE FOR SOLAR LIGHT (7.5 Mtr.)
- Supply, installation, testing and commissioning of 7.5mtrs MS tubular pole conforming
to the technical specifications & drawings forming part of this document. Each 7.5
meter long 60mm dia 3.65mm thick MS tubular pole shall have barcket for mounting
Solar Light at top, 300x300x6mm base plate. Solar Panel will come at top of the pole.
This scope cover Digging for making foundation of the pole. Erecting the pole by
grouting in concrete foundation (The civil construction materials are the part of the
supply against this assignment) made out of 1:3:6: mixture of cement concrete.
3 NON DSR BRACKET LIGHT AT BUILIDING / COLUMN
- Supply, Installation, wiring, connection, testing and commissioning of bracket lighting.
- Supply of GI tubular 38mm dia 2 Mtrs bracket with tubular support.
- Mounting the junction box on the wall / cable tray.
- Welding / fixing the bracket on the wall /column .
- Mounting the street light fixture on the bracket top.
- Connecting the fixture by using 3C x 2.5sq. mm PVC flexible copper wires of color
green, red and black to the junction box.
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
- Testing the connection and completing the installation.
- Painting the bracket with two coats of red oxide and three coats of ALuminium paint.
- The incoming cable work, out going cable work and the earthing of poles are covered
under the cabling and earthing. Nos 11 - 2,053 22,586
4 NON DSR Supply, Installation, wiring, connection, testing and commissioning of an outdoor street
lighting fixtures of 45W LED luminare with Epoxy Powder Coated Pressure die casted
aluminium housing; IP 66 UV Stabilised, IK 08 Front Glass cover; Power factor >0.95;
Total current Harmonics <10%; The LED source used shall be medium/high power
complying with LM80 standards & system efficacy of 100 lms/w.The system lumen
output of the luminaire of a minimum of 4500 lumens with color temprature of 5700
deg K (ANSI Bin) and CRI>80. Integral Driver with constant current constant voltage
(CVCC), P.F>0.95 and Surge Protection of atleast 5KV. INDIABULLS CAT NO. Spectra
LED IORL02-45WH HSP or equivalent with att required accessories and hardware.
5 NON DSR Supply, Installation, wiring, connection, testing and commissioning of LED Mirror Light
fixture with Maximum 9 Watt with minimum 850 lumen, CCT of 5700K with IP20
Protection. INDIABULLS CAT NO. IIBN02-09 XX or equivalent with all required harware
and accessories complete in everyway line junction box, connectors, loop in loop out
strip, flexible cable etc. Nos 6 - 232 1,391
6 NON DSR Supply, Installation, wiring, connection, testing and commissioning of LED SURFACE
MOUNTED Light fixture with Maximum 24 Watt with minimum 1800 lumen, CCT of
5700K with IP20 Protection. INDIABULLS CAT NO. IRLDS21SQ or equivalent with all
required harware and accessories complete in everyway line junction box, connectors,
loop in loop out strip, flexible cable etc. Each 8 - 1,346 10,767
7 NON DSR Supply, Installation, wiring, connection, testing and commissioning of LED SURFACE
MOUNTED Light fixture with Maximum 40 Watt with minimum 4800 lumen, CCT of
5700K with IP65 Protection. INDIABULLS CAT NO. IIEL03-04 WH120 or equivalent with
all required harware and accessories complete in everyway line junction box,
connectors, loop in loop out strip, flexible cable etc. Each 55 - 2,186 1,20,216
8 NON DSR Supply, Installation, wiring, connection, testing and commissioning of LED RECESSED
MOUNTED Light fixture with Maximum 18 Watt with minimum 1650 lumen, CCT of
6500K with IP20 Protection. INDIABULLS CAT NO. IRLDR01RD or equivalent with all
required harware and accessories complete in everyway line junction box, connectors,
loop in loop out strip, flexible cable etc. Each 28 - 629 17,618
9 NON DSR Supply, Installation, wiring, connection, testing and commissioning of LED HIGHBAY
Light fixture with Maximum 80 Watt with minimum 8000 lumen, CCT of 5700K with
IP65 Protection. INDIABULLS CAT NO. IIBL12RD-80 WH (90 DEG) or equivalent with all
required harware and accessories complete in everyway line junction box, connectors,
loop in loop out strip, flexible cable etc. Each 142 - 3,709 5,26,697
10 NON DSR Supply, Installation, wiring, connection, testing and commissioning of LED HIGHBAY
Light fixture with Maximum 120 Watt with minimum 12000 lumen, CCT of 5700K with
IP65 Protection. INDIABULLS CAT NO. IIBL19RD-120 WH (60 DEG) or equivalent with
all required harware and accessories complete in everyway line junction box,
connectors, loop in loop out strip, flexible cable etc. Each 30 - 4,570 1,37,105
11 Supply, installation, testing and commissionin of following polycarbonate weather
proof (IP-65) junction boxes including terminal / connector block complete as required.
11.1 NON DSR One way Nos 2 - 442 885
11.2 NON DSR Two way Nos 2 - 442 885
11.3 NON DSR Three way Nos 2 - 442 885
12 NON DSR Supply, Installation, wiring, connection, testing and commissioning of an outdoor 35W
LED Stree Lighting fixtures with 6000 with lumens with Aluminium Pressure die casted
anti-corresive coating and poly carbonate cover; IP 65, CRI>70, CCT-5700k. Solar Street
light fixture shall have 60watt solar panel module, 12V DC, 384AH inbuilt battery bank
(LiFePo4), PIR sensor. The fixture shall have integrated MPPT charger with driver. This
fixture shall be pole mounted and shall have adjustable angle upto 0-15 degre. The
fixture shall have driver with efficienncy 90%. Philips Cat No. LED BRP710LED60 CW
MR HY FDIN20 SOLAR IN or equivalent with att required accessories and hardware.
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
Total of SH (H) External Lighting - 14,70,235
I SUBSTATION WIRING & ACCESSORIES
1.1 DSR-2018 (1.3) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
Page No. 1 PVC insulated copper conductor single core cable in surface / recessed steel conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
a DSR-2018 (1.3.3) Group C
1.2 DSR-2018 (1.54) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
Page No. 9 point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed steel conduit, and earthing the point
with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as
a DSR-2018 (1.54.3) Group C
1.4 DSR-2018 (1.5) Wiring for light / power plug with 2X4 sq. mm FRLS PVC insulated copper conductor
Page No. 1 single core cable in surface / recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC
insulated copper conductor single core cable for loop earthing as required.
1.5 DSR-2018 (1.7) Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR /
Page No. 2 FRLS PVC insulated copper conductor in the surface / recessed ISI marked 20 mm dia
MS conduit alongwith MS inspection / bends, MS sockets, iron staples / saddles /
screws, fasteners and terminating pipe at both ends using suitable MS adaptor as
required. Rates shall be all inclusive of wiring, MS conduits, suspenders and all other
related accesories as required in complete.
a DSR-2018 (1.7.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Page No. 4 Meter 17 75 1,238
Page No. 4 Meter 109 117 12,741
1.7 DSR-2018 (1.18) Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper
Page No. 5 conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC
conduit as required.
Page No. 5 Meter 40 20 800
1.8 DSR-2018 (1.20) Supplying and fixing of following sizes of steel conduit along with accessories in
Page No. 5 surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required.
a DSR-2018 (1.20.1) 20 mm dia ISI mark Steel conduit
b DSR-2018 (1.20.2) 25 mm dia ISI mark steel Conduit
c DSR-2018 (1.20.3) 32 mm dia ISI mark steel Conduit
d DSR-2018 (1.20.4) 40 mm dia ISI mark steel Conduit
1.9 DSR-2018 (1.24) Supplying and fixing following modular switch / socket on the existing modular plate &
Page No. 6 switch box including connections but excluding modular plate etc. as required.
a DSR-2018 (1.24.1) 5/6 amps switch
Page No. 6 Each 8 85 680 -
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
c DSR-2018 (1.24.3) 15/16 A switch
d DSR-2018 (1.24.4) 3 pin 5/6 amp socket outlet
Page No. 6 Each 8 111 888 -
e DSR-2018 (1.24.5) 6 pin 15/16 A socket outlet
f DSR-2018 (1.24.6) Telephone socket outlet
Page No. 6 Each 4 119 476 -
1.10 NON DSR 2 module RJ-45 socket outlet in existing outlet complete in every way as required. Each 4 - 1,093 4,371
1.11 NON DSR Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed
Steel / PVC conduit as required. Metre 40 - 49 1,961
1.12 NON DSR Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper
conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC
conduit as required. (For Telephone) Metre 40 - 30 1,200
1.13 DSR-2018 (1.25) Supplying and fixing two module stepped type electronic fan regulator on the existing
Page No. 6 modular plate switch box including connections but excluding modular plate etc. as
required. Each 2 342 684 -
1.14 DSR-2018 (1.26) Supplying and fixing modular blanking plate on the existing modular plate & switch box
Page No. 6 excluding modular plate as required. Each 4 32 128 -
1.15 DSR-2018 (1.27) Supplying and fixing following size / modules, GI box alongwith modular base & cover
Page No. 6 plate for modular switches in recess etc as required.
a DSR-2018 (1.27.1) 1 or 2 Module (75mmX75mm)
Page No. 6 Each 4 243 972 -
b DSR-2018 (1.27.2) 3 Module (100mmX75mm)
c DSR-2018 (1.27.3) 4 Module (125mmX75mm)
1.16 DSR-2018 (1.28) Supplying and fixing following Modular base & cover plate on existing modular metal
Page No. 7 boxes etc. as required.
a DSR-2018 (1.28.1) 1 or 2 Module
Page No. 7 Each 4 114 456 -
b DSR-2018 (1.28.2) 3 Module
c DSR-2018 (1.28.3) 4 Module
1.16 DSR-2018 (1.33) Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden
Page No. 7 block including connection etc as required. Each 116 65 7,540 -
1.17 DSR-2018 (1.38) Supplying and fixing call bell / buzzer suitable for single phase, 230 V, complete as
Page No. 8 required. Each 1 92 92 -
1.18 DSR-2018 (1.45) Installation, testing and commissioning of ceiling fan, including wiring the down rods of
Page No. 8 standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,
single core cable, including providing and fixing phenolic laminated sheet cover on the
fan box etc. as required. Each 2 203 406 -
1.19 DSR-2018 (1.49) Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
1.20 DSR-2018 (1.50) Installation of exhaust fan in the existing opening, including making good the damage,
Page No. 8 connection, testing, commissioning etc. as required.
a DSR-2018 (1.50.1) Upto 450 mm sweep
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
b DSR-2018 (1.51) Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.
1.21 NON DSR Supply of 300mm diameter single phase, 230 V AC, 50 Hz Industrial exhaust fan for
toilets complete with motor, capacitor, fan assembly mounting frame & louvers with 3
core flexible wire.. Each 11 - 4,570 50,272
1.22 NON DSR Supply of 450mm diameter single phase, 230 V AC, 50 Hz Industrial exhaust fan for
toilets complete with motor, capacitor, fan assembly mounting frame & louvers with 3
core flexible wire.. Each 6 - 5,391 32,349
1.23 NON DSR Supply of 48/56 inch diameter, three blade, single phase, 230 volt AC, 50 Hz, ceiling fan
complete with the motor, starting capacitor, fan assembly, hang pipe, top bottom
domes, required hardwares etc. Each 2 - 2,570 5,140
TOTAL of SH (I) Supply & Fixing of Fans 5,53,754 95,293
J. MCCB, MCB & DBs
1.1 DSR-2018 (2.3) Supplying and fixing following way, single pole and neutral, sheet steel, MCB
Page No. 11 distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
a DSR-2018 (2.3.1) 6 way , Double door
b DSR-2018 (2.3.2) 8 way , Double door
c DSR-2018 (2.3.3) 12 way , Double door
1.2 DSR-2018 (2.4) Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,
Page No. 12 MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB / RCCB / Isolator)
a DSR-2018 (2.4.1) 4 way (4 + 12), Double door
b DSR-2018 (2.4.2) 6 way (4 + 18), Double door
c DSR-2018 (2.4.3) 8 way (4 + 24), Double door
1.3 NON DSR Supply, installation, testing and commissioning of wall mounted, vermin proof, dust
proof, indoor duty, front door for access SDB's will have FOUR TIER PPI type 12 Ways
TPN DB metal casing with double door and shall be of fabricated with minimum 1.4
mm thick CRCA sheet and powder coated, as mentioned in this document and shall
have lockable front door and this lock shall be flushed with main door with common
key for all SDB. (This item excludes MCBs and incomer). Each 2 - 8,488 16,975
1.4 DSR-2018 (2.5) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V,
Page No. 12 TPN MCB distribution board of sheet steel, dust protected, duly powder painted,
inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for
mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type
MCB TPDB is normally used where 3 phase outlets are required.)
a DSR-2018 (2.5.1) 4 way (4 + 12), Double door
b DSR-2018 (2.5.2) 8 way (4 + 24), Double door
1.5 DSR-2018 (2.10) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit
Page No. 12 breaker suitable for inductive load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as required.
a DSR-2018 (2.10.1) Single pole
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
b DSR-2018 (2.10.4) Triple pole
c DSR-2018 (2.10.5) Triple pole and neutra
1.6 DSR-2018 (2.11) Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as
Page No. 12 required. Each 5 8 40 -
1.7 DSR-2018 (2.12) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
Page No. 12 MCB DB complete with connections, testing and commissioning etc. as required.
1.8 DSR-2018 (2.13) Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB
Page No. 13 DB complete with connections, testing and commissioning etc. as required.
1.9 DSR-2018 (2.14) Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,
Page No. 13 residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and commissioning etc. as
8.10 DSR-2018 (2.16) Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A,
Page No. 13 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as
required. Each 1 848 848 -
8.11 DSR-2018 (2.18) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and
Page No. 13 earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket out let and
complete with connections, testing and commissioning etc. as required. Each 10 1,232 12,320 -
8.12 DSR-2018 (2.19) Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and
Page No. 13 earth, metal enclosed plug top alongwith 20 A, “C” curve, TP MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket out let and
complete with connections, testing and commissioning etc. as required. Each 5 1,690 8,450 -
TOTAL of SH (J) MCCB, MCB & DBs 2,23,946 16,975
K 11KV HT METERING
1 NON DSR Supplying fixing connecting testing and commissioning of 11 KV metering cubicicle
panel complete with CT's and PT's and Trivector Meter with MDI complete with
necessary accessories and connections etc as required
3 Each 11kV/110V Single phase cast resin PT's (50 VA) burden, Accuracy Class 0.5)
3 Each 15/5A, 11kV cast resin CT's (15 VA) burden, Accuracy Class - 0.5)
1 No. electrtic digital Trivector Meter with MDI (Accuracy Class 0.5)
HT Cable Box suitable for 2 Each 3 Core x 185 sqmm HT AL cable (incoming and
Thje contractor shall get tested and arrange approval of metering panel as well as
equipment including their sealing etc. from UPPCL as required.
The erection rate shall include meter testing charges etc.
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
In case State Electricity Board provides above panel then this item will not be executed.
Contractor has to get approval from State Electrical Board before procuring this panel.
Total of SH (K) HT METERING - 1,25,780
L 11 KV HT VCB PANEL
1.0 NON DSR Supply, unloading, placing to foundation, erection, testing and commissioning of
OUTDOOR TYPE (IP55) ICOG Panel Board / HT Panel - 11 KV, 630A, 3 Phase, 50 Hz,
metal clad, dead front, 350MVA repturing capacity VCB incoming & outgoing as per
specification and and schematic drawing including connections etc. complete with
following incomer and outgoings including door interlocking and expendable as
1No 630A, 18.3kA for 3sec motorised type drawout VCB circuit breaker horizontally
insulated horizontal drawout, electrical motor operated, spring charged with facility of
manual closing.
1No. Three phase 11kV/√3/110V/√3/110V/√3 Fixed PT star/star/satar rated 50 VA for
1st secondary, class 0.5 for metering & 50 VA for second secondary, class 3P for
protection connected to incoming side of the breaker through fuse on H.T side &
through MCB on LT side along with auxiliary contacts. PT shall be manufactured and
tested as per IEC standard.
1 Set of Phase indicating lamps with suitable MCB
1 No 0-15 kV Digital Voltmeter with selector switch
1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP
CIRCUIT HEALTHY.
Push botton for ON, OFF, TRIP & TRIP circuit healthy.
3 Nos combined 11kV cast resin 30/15/5+5A current transformer 1st winding of
5P20,10VA class for protection, 2nd winding of 0.5 class for metering. CT burden shall
be minimum 10 VA for metering and protection. The CT shall have short links. The CT
shall be manufactured and tested as per IEC standard for partial discharge. The CT shall
with stand fault level of 18kA for 1 sec.
One no. numerical combined based three phase over current with earth fault relay
having IDMT and instantaneous with high set element, 1 no. trip circuit supervision
relay, 1 no. master trip relay, 1 no. anti-pumping relay. Only master trip relay and trip
supervision relay will be electro mechanical. The main numerical relay shall be micro-
processor based.
1 No 0-630 Digital Amps ammeter with slector switch
1 Set of undervoltage relay and Overvoltage relay
1 No. power pack with 24V DC, 17AH (minimum) battery bank capacity.
1 Set of MCB, control wiring, protection wiring, and other item required for the desired
operation of the unit selector switch to indicate the currents.
1 Set indicating light for Spring Charge / Discharge. The spring shall immediately charge
itself for next operation.
Annunciator window (minimum 6 window) for all electrical fault.
Cable entry to the breaker can be from bottom as per site conditions.
All interconnected control wiring. Set 1 - 5,61,275 5,61,275
1.1 NON DSR Supply, unloading, placing to foundation, erection, testing and commissioning of
OUTDOOR TYPE (IP55) ICOG Panel Board / HT Panel - 11 KV, 630A, 3 Phase, 50 Hz,
metal clad, dead front, 350MVA repturing capacity VCB incoming & outgoing as per
specification and and schematic drawing including connections etc. complete with
following incomer and outgoings including door interlocking and expendable as
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1No 630A, 18.3kA for 3sec motorised type drawout VCB circuit breaker horizontally
insulated horizontal drawout, electrical motor operated, spring charged with facility of
manual closing.
1No. Three phase 11kV/√3/110V/√3/110V/√3 Fixed PT star/star/satar rated 50 VA for
1st secondary, class 0.5 for metering & 50 VA for second secondary, class 3P for
protection connected to incoming side of the breaker through fuse on H.T side &
through MCB on LT side along with auxiliary contacts. PT shall be manufactured and
tested as per IEC standard.
1 Set of Phase indicating lamps with suitable MCB
1No 0-15 kV Digital Voltmeter with selector switch
1 Set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP
CIRCUIT HEALTHY.
Push botton for ON, OFF, TRIP & TRIP circuit healthy.
3 Nos combined 11kV cast resin 30/15/5+5A current transformer 1st winding of
5P20,10VA class for protection, 2nd winding of 0.5 class for metering. CT burden shall
be minimum 10 VA for metering and protection. The CT shall have short links. The CT
shall be manufactured and tested as per IEC standard for partial discharge. The CT shall
with stand fault level of 18kA for 1 sec.
One no. numerical combined based three phase over current with earth fault relay
having IDMT and instantaneous with high set element with 1 no. seperate static
standby earth fault relay, 1 no. trip circuit supervision relay, 1 no. master trip relay, 1
no. anti-pumping relay, 5 nos. two element transformer auxiliary relay for oil & winding
temperature, Buck holz , Oil surge and PRV. Only master trip relay and trip supervision
relay will be electro mechanical. The main numerical relay shall be micro-processor
1 no. gap less surge suppressor at 10 kV with minimum 5kA discharge current for 8/20
microsecond heavy duty type meeting IEEE std.
1No 0-630 Digital Amps ammeter with slector switch
1No. Multifunction meter of class 0.5
1 Set of undervoltage relay and Overvoltage relay
1No. Digital Power factor meter.
1 No. power pack with 24V DC, 17AH (minimum) battery bank capacity.
Breaker shall have 24V DC cloosing and tripping.
- 1 Set of MCB, control wiring, protection wiring, and other item required for the desired
operation of the unit selector switch to indicate the currents.
- 1 set indicating light for Spring Charge / Discharge. The spring shall immediately charge
itself for next operation.
Annunciator window (minimum 12 window) for all electrical fault.
1.1a Cable entry to the breaker can be from bottom as per site conditions.
1.1b Any extra item which is required to execute the above work satisfactorily as per specs
Total of SH (L) 11 KV HT VCB PANEL Rs. - 11,76,466
M TRANSFORMER (200 KVA)
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
External & Internal Electrical works
DSR-2018 / DSR-2018 NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY
NON DSR RATE AMOUNT RATE AMOUNT
1 NON DSR Supply, installation, testing and comissioning of 200 kVA oil filled, 11kV/433V, ONAN
type copper wound out door type with OCTC, weather proof type transformer with
Impedence 4.5% and transformer losess shall be as per efficiency level 2 (50% load
losess -0.78kW and 100% load losess -2.3kW). Transformer shall have cable box for
both HT & LT side and with 9 steps from +10% to -10% tap in step of 2.5%. Transformer
shall be designed with ambient temperature at 50 degree. Permissible temperature
rise above ambient shall be 40 degree in oil and 45 degree in winding. The transformer
shall have oil temperature gauge and transformer shall be complete with all
accessories making all connection and carrying out all routine test before
commissioning. No. 1 - 6,42,278 6,42,278
Total of SH (M) TRANSFORMER - 6,42,278
N INVERTER SYSTEM
1.1 5KVA INVERTER
NON DSR Supply, installation, testing, rectification and commissioning of 5kVA 1ph inverter with
maintenance free batteries (Tubular), upto 90 minutes back-up complete with M.S.
batteries rack / trolley & with connecting wires. Nos. 1 - 1,36,915 1,36,915
1.2 0.5KVA INVERTER
NON DSR Supply, installation, testing, rectification and commissioning of 0.5kVA 1ph inverter
with maintenance free batteries (Tubular), upto 90 minutes back-up complete with
M.S. batteries rack / trolley & with connecting wires. Nos. 3 - 20,318 60,954
Total of SH (N) INVERTER - 1,97,869
TOTAL AMOUNT 24,93,881 86,53,891
TOTAL AMOUNT 24,93,881 86,53,891
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
Fire alarm & PA works
DSR-2018 / DSR-2018 RATE NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY REMARKS
NON DSR RATE AMOUNT RATE AMOUNT
A FIRE ALARM AND PUBLIC ADDRESS SYSTEM
1.0 AUTOMATIC ADDRESSABLE FIRE DETECTION & ALARM SYSTEM
1.1 DSR-2018 Supplying, installation, testing and commissioning of micro processor based
(17.2.1) intelligent addressable main fire alarm panel, central processing unit with
Page No. 65 the following loop modules and capable of supporting not less than 240
devices (including detectors) and minimum 120 detectors per loop and loop
length up to 2 km, network communication card, minimum 320 character
graphics/ LCD display with touch screen or other keypad and minimum 4000
events history log in the non volatile memory (EPROM), power supply unit
(230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have facility to connect
printer to printout log and facility to have seamless integration with
analog/digital voice evacuation system (which is part of the schedule of
work under SH: PA System) and shall be complete with all accessories. The
panel shall be compatible for IBMS system with open protocol BACnet/
Modbus over IP complete as per specifications.
1.1.1 DSR-2018 Two Loop Panel.
1.2 DSR-2018 Supplying, installation, testing & commissioning of repeater panel wih 320
(17.2.3) character/ Touch screen LCD display with inbuilt reset, acknowledge and
Page No. 66 silence switches complete as required. No 1 1,08,572 1,08,572 -
1.3 DSR-2018 Supplying, installation, testing & commissioning of intelligent analog
(17.2.4) addressable photothermal detector complete with mounting base complete
Page No. 66 as required. Nos 164 2,846 4,66,744 -
1.4 DSR-2018 Supplying, installation, testing & commissioning of response indicator on
(17.2.5) surface/recessed MS Box having two LED, metallic cover complete with all
Page No. 66 connections etc as required. Nos 10 263 2,630 -
1.5 DSR-2018 Supplying, installation, testing & commissioning of addressable beam
(17.2.12) detector with short circuit isolator (inbuilt or seperate) complete with
Page No. 66 emitter and receiver including connections with remote test features etc
complete as required. No 1 74,778 74,778 -
1.6 DSR-2018 Supplying, installation, testing & commissioning of addressable manual call
(17.2.14) point complete as required.
1.7 DSR-2018 Supplying, installation, testing & commissioning of addressable horn cum
(17.2.15) strobe complete as required.
1.8 NON DSR Supplying & laying of 2C x 2.5 sqmm Copper armoured FRLS cable complete
in everyway. Mtrs. 1500 - 83 1,23,832
2.0 PAVA SYSTEM
2.1 DSR-2018 Supplying, installation, testing & commissioning of 6 zone, voice alarm
(17.3.1) controller with USB, MP3 player (including 6 zone button paging station)
Page No. 67 with seamless integration facility with main fire alarm panel for voice
evacuation complete as required. No. 1 1,26,399 1,26,399 -
Name of Work- Construction and development of Pre Engineered Manufacturing Unit at Industrial Plot No. B-208, at sector Phase-II, Noida
Fire alarm & PA works
DSR-2018 / DSR-2018 RATE NON DSR
Sr. No. DESCRIPTION OF ITEM UNIT QTY REMARKS
NON DSR RATE AMOUNT RATE AMOUNT
2.2 NON DSR Supply, Installation,Testing & Commissioning of Duel channel 250W Power
Amplifier with high efficiency, low power consumption with self indicator
testing function, self-protection from overheat, overcurrent,
overvoltage,under voltage, overload and short circuit, balanced and
unbalanced audio inputs. Make: Henrich/Bosch/Ateis No. 1 - 55,637 55,637
2.3 NON DSR Supply, Installation, Testing & Commissioning of wall Mounted Voice
Evacuation horn type Speaker having power taps upto 30W and cable tags
and Ferruling etc. complete as required.Complete Aluminum grille and
Metal baffle, line matching transformer 100/70V line. Make:
Henrich/Bosch/Ateis No. 9 - 4,636 41,728
2.4 NON DSR Supply, Installation, Testing & Commissioning of 20W Bidirectional
projection loudspeakers with following features:-component 2*6",
Complete metal grille and line matching transformer 100/70V line. Variable
wattage tapings of 5/10/20W, Effective frequency range 100-15kHz
(BS6840), SPL@1m/1W=91dB, Peak SPL 110dB complete with necessary
mounting hardware & accessories. Make: Henrich/Bosch/Ateis/Ahuja
2.5 DSR-2018 Supplying, installation, testing & commissioning of 1.5/3/6W metal box
(17.3.2) ceiling/wall speakers complete as required.
2.6 DSR-2018 Supplying, installation, testing & commissioning of 1.5/3/6W metal box
(17.3.3) ceiling/wall speakers complete as required.
2.7 NON DSR Supplying & laying of 2C x 2.5 sqmm Copper armoured FRLS cable complete
in everyway. Mtrs. 600 - 83 49,533
Total of SH (O) FIRE ALARM AND PUBLIC ADDRESS SYSTEM 11,77,342 3,43,588
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
NIT.pdf
Tender Document
GCC2019FinaL17.pdf
Tender Document
List of Make.pdf
Tender Document
TECHNICAL SPECIFICATIONS.pdf
Tender Document
Integrity Pact.pdf
Tender Document
Instruction to bidder.pdf
Tender Document
SCC.pdf
Tender Document
Tender Drawings.pdf
Tender Document
Final BOQ.pdf
Tender Document
corrigendum-836-Corrigendum 02 uploaded.pdf
pdf • 0.68 MB
corrigendum-809-Corrigendum 01.pdf
pdf • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .