AEE (C), IWD on behalf of IISER Kolkata
IISER Kolkata, IWD Section, Mohanpur, Nadia, West Bengal, 741246
Construction of a small chicken experimental shed adjacent to the Behaviour and Ecology Field Station
2024_IISER_799559_1
IISER-K/Civil/23-24/24
Open Tender
Civil Works
Works
60 days
IISER Kolkata, Mohanpur
As per tender document
9 documents required · 9 mandatory
₹500
IISER Kolkata
₹10,830
5 Apr 2024
8 Mar 2024
26 Mar 2024
8 Mar 2024
23 Mar 2024
8 Mar 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
(i) All kinds of soil
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
(i) All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
(i) Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
(i) Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
(i) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
(ii) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
(i) Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
(i) Mild steel and Medium Tensile steel bars
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
(i) Cement mortar 1:4 (1 cement :4 coarse sand)
12 mm cement plaster of mix :
(i) 1:6 (1 cement: 6 fine sand).
15 mm cement plaster on the rough side of single or half brick wall of mix :
(i) 1:6 (1 cement: 6 fine sand)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
(i) Using flats 30x6mm for diagonal braces and central cross piece.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.
(i) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
(i) 40 mm thick with 20 mm nominal size stone aggregate sqm
Neat cement punning.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
(i) Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade :
(i) New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
(i) Two or more coats on new work
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
With 15mm thick tegular edged light weight calcium silicate false ceiling tiles
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
(i) Ridges plain (500 - 600mm).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). metre
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (a)Kitchen sink without drain board
(i) 610x510 mm bowl depth 200 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
(i) 32 mm dia
Providing and fixing PTMT bib cock of approved quality and colour.
(i) 15 mm nominal bore, 122mm long, weighing not less than 99 gms
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
(i) 25 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work:
(i) 15 mm nominal dia Pipes
(ii) 20 mm nominal dia Pipes
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
(i) 75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Single tee with door
(i) 75x75x75 mm
(b) Bend 87.5° , (i) 75 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Cutting holes up to 30x30 cm in walls including making good the same:
(i) With common burnt clay F.P.S. (non modular) bricks
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
(i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm).
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.
(i) 300 mm weighing not less than 200 grams
Providing and fixing anodized glazed aluminium work for partition made up with 1.5 mm thick aluminium tubular section 2.5" x 1.5"as frame, fixed with rawl plugs and screws etc. including cleat angle, aluminium snap beading for glazing/ panelling, with fixing clip or with expansion hold fastners including necessary filling up of gap at junctions at top, bottom and sides with required PVC/ neoprene felt, rubber gasket along with aluminium beading, taper clip of required section etc., panel to be covered with 4 mm thick ACP (Aluminium composite panel) board including rubber gasket and taper clip etc. all complete as per direction of Engineer-in-charge.
Providing and fixing anodized aluminium work for door shutter, frame made up with 1.5 mm thick aluminium tubular section 1 3/4"x1 3/4" as vertical member, top and middle section - 2"x1 3/4", bottom section 4"x 1 3/4" and with fixing clip or with expansion hold fastners including necessary filling up of gap at junctions at top, bottom and sides with required PVC/ neoprene felt, rubber gasket along with aluminium beading, taper clip of required section etc., 4 mm thick ACP (Aluminium composite panel) board and 5.5 mm thick plane float glass including rubber and taper clip and ISI marked SS hinge, rolling wheel, G channel, 6"aluminium handle, locking arrangement with conceal lock etc. all complete as per direction of Engineer-in-charge. i) Door shutter (sliding/hinged).
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .