Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.6 LAccepted-AOC ARUVEETTIL HOUSE KARUVAMBRAM POST ACHIPILAKKAL MANJERI MALAPPURAM DIST | MANJERI | MALAPPURAM | KERALA | 1 | Accepted-AOC L1 BIDDER ACCEPTED. Contract value shown is excluding GST | |
| 2 | 2₹12.0 L+₹37,629 (3.24%)Rejected-Finance THANDUPARAKKAL HOUSE VANIYAMBALAM P O WANDOOR MALAPPURAM 679339 | WANDOOR | MALAPPURAM | KERALA | 679339 | 2 | Rejected-Finance L2 Rejected | |
| 3 | 3₹13.5 L+₹1.8 L (15.7%)Rejected-Finance | 3 | Rejected-Finance L3 Rejected | |
| 4 | Rejected-Technical GOPIKA HOUSE KOTTAKUNNU S BATHERY POST WAYANAD KERALA PIN 673 592 | S BATHERY | WAYANAD | KERALA | 673592 | - | Rejected-Technical Rejected |
Tender Value
₹12 L
EMD Value
₹30,000
Closing Date
13 Feb 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dairy Manager
MRCMPU Ltd, Milma Wayanad Dairy, Chuzhali, Kalpetta PO, Wayanad
Construction of Night Shelter Facility for Lady employees at Milma Wayanad Dairy
2024_KCMMF_644312_1
WYD/ENGG/129/NSF/2023-24/1786
Open Tender
Civil Works - Buildings
Item Rate
60 days
Kalpetta
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,500
₹30,000
17 Apr 2024
15 Jan 2024
14 Feb 2024
15 Jan 2024
13 Feb 2024
15 Jan 2024
Amount
Work Items
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.
Supplying and filling with approved local sand (M-sand) free from pebbles, debris etc in sunken slab including ramming consolidating and dressing complete.
Providing and laying in position plain cement concrete of mix 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) including the cost of centering and shuttering - All work up to plinth level
Providing and laying in position reinforced cement concrete for reinforced cement concrete work of mix 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size), but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All works above plinth level
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers
Centering and shuttering including strutting, etc. and removal of form above plinth level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Thermo - Mechanically Treated bars of grade Fe-500 or more
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and Laying of 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Providing & Applying two coat of water thinnable cement primer of approved brand and manufacture on wall surface:<br>Water thinnable cement primer
Providing and Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and laying double charge vitrified floor tiles in floors, skirting etc in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make in all colours and shades laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), complete.Size of Tile 600 x 600 mm. (make: johnson/kjaria/rak/nitco/equivallant)
Providing and laying vitrified matt floor tiles in different sizes (8-12mm thickness) with water absorption less than 0.08% and conforming to IS : 15622, of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand),including 3mm spacer joints and filled with epoxy tile joint filler etc., complete. (make: johnson/kjaria/rak/nitco/equivallant)
Providing and fixing vitrified glazed tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make in all colours, shades of any size as approved by Engineer -in-Charge, in wall over tile adhesive for wall tile fixing including pvc corner beading complete.(make: johnson/kjaria/rak/nitco/equivallant)
Providing and fixing fully panelled side hung doors with frame, made of powder coated aluminium extruded architectural sections of specified size with shutter comprising of section having bottom rail of size 100mmx44.5mm, lock rail of size 50 mm x 45 mm , top rails 50mm x 44.45 mm , vertical style 50mm x 44.45 mm and outer frame comprising P section of size 63.5mmx46.5mm all with a minimum thickness of 1.2mm. The top and bottom rail shall be reinforced with 8/10mm dia rods. The door shall be panelled with 5/6mm thick Thomoson multiwood panel including handle, EPDM gasket, screws, fastners, lock & key, door stopper etc. as per the drawing and specifications. (Out to out area of door frame shall be measured in sqm for payment.)
Providing and fixing powder coated fully glazed two track two paneled sliding windows made of powder coated aluminium extruded architectural sections of 27mm series frames 45x45mm and 65x27.1 mm shutter frame all having wall thickness of 1.4 ± 0.2 mm and glazing with 5mm thick approved clear/reflective type glass including necessary glazing bead of appropriate dimension, handle, lock, EPDM/Neoprene gasket, screws, fasteners etc. as per enclosed technical specifications, drawings and/or directions of Engineer in charge. The gap in between aluminium frame and adjacent rcc/brick/stone work shall be sealed by weather silicon sealant over backer rod of approved quality. (Out to out area of the window frame shall be measured in sqm for payment.)
Providing and fixing louvered ventilator made of 5mm thick shaded glass fixed to powder coated aluminium extruded frame of size 63.5x38.1x1mm including fastners, screws etc. complete including provision for exhaust fan as per requirement
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including two coat priming coat with approved steel primer and two coat enamel paint all complete.
Steel work in built up M.S tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved two coat steel primer and two coat enamel paint, including welding and bolted with special shaped washers etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.45 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Tata/JSW)
Providing and fixing precoated galvanised steel sheet ridge 0.45 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:
Providing and fixing Square UPVC gutter of minimum 160mm wide and 100mm depth including fittings, drop, clamp etc. complete.
Providing and fixing false ceiling with 9mm TKT thick PVC panel board (make: sintex/johnson or equivalent) ceiling of approved quality including aluminium frame work with necessary screws to fix the PVC panel to aluminium hollow sections which is in the form of grid and the grid is fixed to the roof truss/purlins/ structural member by using aluminum sections and runners as per technical specifications.complete.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed/open work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed/open work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed/open work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed/open work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed/open. 40 mm pipe 10 kgf/ cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/ clips/ at 1.00 m spacing. This includes jointing of pipes and fittings with one step PVC solvent cement and testing of jointscomplete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Exposed on wall/slab
Providing and fixing PVC pipes, fittings including jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/ clips/ at 1.00 m spacing. This includes jointing of pipes and fittings with one step PVC solvent cement and testing of jointscomplete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Exposed on wall/slab
Providing and fixing PVC pipes, fittings includings jointing of pipes and fittings with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed/open. 50 mm pipe 6 kgf/ cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
Providing and fixing UPVC ball valve of approved quality: 20mm nominal bore
Providing and fixing UPVC ball valve of approved quality: 25mm nominal bore
Providing and fixing UPVC ball valve of approved quality: 32mm nominal bore
Providing and fixing UPVC ball valve of approved quality: 40mm nominal bore
Providing and fixing CP brass angle cock conforming to IS 8931, 15mm nominal bore
Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 8931: 15mm NB
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps
Supply and Labour for installation of PVC Multi Inlet floor trap 110x75x50/40mm. (Supreme/Astral/ Finolex)
125x125mm CP Stainless Steel Gratings with Cockroach Protection for multi inlet floor trap.
Supplying approved make PVC gully trap of size 110 x 110mm and grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 110mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge
Supply and Labour for Installation, testing and commissioning of PVC type Manholes, valvechamber, sandtrap etc.. with suitable PCC around it with fit and finish and including excavation, back-filling,PCC, disposel, waterproofing etc upto 1 mtr depth/as per the site condition all in accordance with the drawing/ specification or relevant standards and its Cover with suitable frame and accessories 300mmx300mm ( Supreme/Finolex/Astral or equivallant)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Aneesh T P
GRACE ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .