Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.3 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹84.5 L+₹2.6 L (3.14%)Rejected-Finance GANGA NAGAR NEAR TUSHARCHAKRA MISAMARI 784506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹84.9 L+₹3.0 L (3.69%)Rejected-Finance HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹85.5 L+₹3.6 L (4.42%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹86.5 L+₹4.6 L (5.62%)Rejected-Finance GORUBANDHA MISSAMARI SONITPUR ASSAM 784506 | SONITPUR | SONITPUR | ASSAM | 784506 | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹77.5 L
EMD Value
₹1.4 L
Closing Date
11 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI SAURABH, IDSE
HQ CWE TENGA PIN-900194 C/O 99 APO
SPL REPAIR TO BLDG. NO T-14, T-22 AND T-39 OF FD REGT UNDER GE MISSAMARI
2025_MES_708001_1
8535/E8
Open Tender
Civil Works
Item Rate
GE MISSAMARI
C (a) (i)
8 documents required · 8 mandatory
₹1,000
Yes
GE MISSAMARI
₹1.4 L
Yes
19 Jul 2025
14 May 2025
18 Jun 2025
14 May 2025
11 Jun 2025
4 Jun 2025
Amount
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings. complete all as Specified and directed.
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as Specified and directed.
S&F pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as Specified and directed.
Taking down/Dismantlinig wrought iron or mild steel work of any description not otherwise proveded for complete all as Specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe-290 (Gde E- 165) complete all as Specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as Specified and directed.
S&F for Anodised aluminium/ GI snap grid power coated framed work of size main runner 39x24.70x0.80 mm, cross tee size 29.x24.70x0.80 mm, wall angle 22.2x22.2x0.65 mm and size of grid 605x605 mm for false ceiling all as specified with 4mm thick GI suspender complete all as specified and as directed.
M & L for 4m thick Non Asbestos of size 600 x 600mm fixed in ceiling designed Cement E board incl two coats of distempering in one side, complete all as specified and direction as per directed by the Engineer-in-charge.
Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as Specified.
M&L Glazed ceramic coloured tiles in vertical surfaces of size 600 x 300 x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match including rendering backing coat 10 mm thick in cement mortar 1:4 completed all as Specified and directed.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes complete all as Specified and directed.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes complete all as Specified and directed.
S&F in repairs 10 Ltrs, Capacity PVC flushing cistern low level with all accessories, flush pipe etc complete all as specified and directed.
S &F in repairs Vitreous china urinals, Half stall type white with grating and union for discharge pipe , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws complete all as Specified and directed.
S&F in repairs Vitreous China squatting pan "Orissa" patern size 630x450mm white with integral foot rest (Excluding flushing cistern & flush pipe) complete all as Specified and directed.
S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including cutting for and pinning ends of brackets or erecting stand complete all as Specified and directed.
PVC connection 15 mm bore 450 mm long complete all as Specified and directed.
S&F in repairs brass chromium plated towel rail 20 mm dia D type 60 cm long between flanges complete all Specified and directed.
Taking down rain water pipes inculding all fittings any size and pattern complete all as Specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as Specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls complete all as Specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as Specified and directed.
S & F 110 mm bore PVC (SWR) Vent Cowl complete all as Specified and directed.
Supply & fix 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as Specified and directed.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar of dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as Specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing complete all as Specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing complete all as Specified and directed.
Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supply and laying 25 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as Specified and directed.
S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as Specified and directed.
S&F in repairs 15mm bore angular stop cock with flange screwed down high pressure with crutch or butter fly handdle screwed both end for iron pipe complete all as Specified and directed.
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws,vitreous China white, Approximate size 160x 160x90 complete all as Specified and directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as Specified and directed.
S&F Grating doom 100 mm dia. with waste hole of CP (minimum weight 40 gms), complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) floor trap 100 mm plain with grating including jointing with solvent cement complete all as Specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including removal to rubbish complete all as specified and as directed.
M&L for brick work with burnt modular bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius and all as directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as Specified and directed.
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 in two layers (10+5 mm) top layer mixed with WPC as per manufacturer instruction and finishing the surface even and smooth without any extra cement complete all as specified and directed. (Note:- WPC shall be measured and paid separately as per supply only items).
Supply only Integral water proofing compound complete all as Specified and directed.
M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth complete all as Specified and directed.
Preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of Red Oxide, zinc chorme and applying two coat of synthetic enamel paint complete all as Specified and directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of synthetic enamel paint complete all as Specified and directed.
M & L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface complete all as Specified and directed.
M & L for Complete removal of old surface for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as Specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper over 1 mm thick wall care putty complete all as Specified and directed.
M&L for complete removal of old surfaces of walls and applying two coats of acrylic distemper over 1 mm thick wall care putty complete all as Specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames) complete all as Specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) complete all as Specified and directed.
S & F Solid pvc Door Frame of size 95 x 50 mm made out of 5mm wood grain colour PVC Sheet reinforced with MS Square etc complete all as Specified and directed.
Supplying and fixing in frame at site, factory made solid panel pvc moulded door shutter 28 to 30 mm thick (style) with 2,4,or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as Specified and directed.
S & F Second class hard wood kiln seasoned and chemically pressure treated plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as Specified and directed.
S & F 35 mm thick Second class hard wood kiln seasoned and chemically pressure treated Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc complete all as Specified and directed.
S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as Specified and directed.
S&F for 2nd class hard wood 30mm thick glazed and skeleton shutter open rebated and prepared to receive glass gauge etc divided into square with rebated sash bars any number edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauge etc (size of members of shutters as specified in SSR Par –I section 8 Clause 8:24 (b) complete all as specified and directed.
S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sqm in each pane complete all as Specified and directed.
S & F Figured glass 4mm thick, pin head type and glazing with gasket in squares n exc 0.5 Sqm in each pane complete all as directed
Supplyand fixed GI wire cloth with 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium stapple complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges and fixed complete all as Specified and directed.
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges and fixed complete all as Specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as Specified and directed.
S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as Specified and directed.
S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as Specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as Specified and directed.
S & F aluminium alloy 300mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy and fixed complete all as Specified and directed.
S & F in repairs Harrison rails, mild steel, chromium plated fixed alongwith 2 Nos. of brackets, stops, rollers etc, complete all as specified.
S & F in 6 mm Plywood, grade BWP,type BB, fixed with screws to timber framework complete all as Specified and directed.
Dismantling framed timber scantlings 40 Sq. cm and over in section and in any position complete all as Specified and directed.
M&L 2nd class hard wood in scantling wrought timber framed and fixed complete all as Specified and directed.
M&L for preparation of new wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as Specified and directed.
Demolition of stone slabs tiles of any description or thickness in floors aprons laid bedded and pointed in any mortar etc complete all as Specified and directed.
M& L for Kota stone slab flooring of 22-25 mm thick over cement screed jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding and polishing complete incl 20 mm thick screed bed 1:6 CM in floors complete all as Specified and directed.
M& L for Granite of any type 20 mm thick cut beded and jointed with grey cement slurry and pointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 20 mm thick Screed bed 1:6 CM in floors complete all as Specified and directed.
All as per items No 74 above but of 18-20 mm thick fixed in vertical surfaces of wall but on 10 mm thick backing coat in Cement Mortar 1:4 complete all as Specified and directed.
Demolition of un- reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as Specified and directed.
M&L for 75 mm thick cement concrete as in plinth protection/ path etc type C-2 1:3:6 (using 40mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified and directed.
M&L for 100mm thick PCC type D2 1:4:8 using (40mm gradded aggregate) as in sub base complete all as Specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 50mm thick sand cushion complete all as specified and directed.
Dismantling PVC/RCC water tanks and removing to store exc 250 & not exc 500 ltrs complete all as Specified and directed.
S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as Specified and directed.
M&L for Post construction Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear mtr including drilling and plugging holes etc. complete all as directed.
M&L for Post construction Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as directed.
M&L for Post Construction Anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution)@ 0.5 litre/ hole by drilling 6mm dia holes at a downward angle of 45 degree a 150mm centre to centre and sealing the same complete all as directed.
Taking down carefully existing unserviceable copper/ aluminium point wiring (light,call bell, two way, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators,bracket light fittings and making good to the disturbed surface complete all as directed by Engr-in-Charge.
Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified by Engr-in- Charge.
Taking down carefully unsv aluminium submain wiring of any type /loc including conduit /casing and earth wire and making good the distributed surface of walls /ceiling matching with existing finishes all as directed by Engr-in-Charge.
Taking out unsv UG Cable any cross sectional area and connection of any description of any description laying in trenches or fixing with wall or poles all as specified and directed.
M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light/Fan/Bell Point controlled by One 1-Way Switch 5 Amp, duly fixed with copper lugs and flexible pipe from ceiling rose to fitting/fixtures complete all as specified and as directed.
Description all as per item No 90 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as Specified and directed.
Description all as per item No. 90 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as Specified and directed.
Description all as per item No 90 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as Specified and directed.
S & F Switch piano (White) flush type single pole one way 5 Amp, 230 Volts complete all as specified.
S & F Socket outlet (White) 2 in 1, 5 pin, 5 Amps complete all as specified and directed.
S & F Switch socket combination(White) flush type multipurpose 5 pin 5 Amps two in one , 230 volts complete all as specified
S&F Switch socket combination (White) 2 in 1 5/6 pin, 15 Amp flush type universal complete all as Specified and directed.
S&F ceilling rose (White) three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all specified
S & F ceiling fan regulator (White) step type 2 Module, flush type heavy duty suitable to work on 230 Volt AC supply complete all as specified.
S & F Lamp holder (White) with insulated body, with back plate suitable for batten fittings complete all as directed.
S & F LED ADORE 10 W B22 CDL 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified.Make-Make- Havells, Cat No: LHLDEUEBML8Z010 or equivalent in CG or Surya complete all as Specified and directed.
S & F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete all as specified and directed :- Make-L&T or equivalent in Schneider/ Legrand complete all as Specified and directed.
S & F MCB FP 415 volts suitable for fixing in MCB TPN DB of capacity 63 amps complete all as specified and directed. Make-L&Tor equivalent in Schneider/ Legrand complete all as Specified and directed.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with locking system complete grouted on walls complete all as specified. Make -L&T/Schneider/ Seimens /Legrand complete all as Specified and directed.
S & F sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with locking system complete grouted on walls complete all as specified and directed. Make -L&T/Schneider/ Seimens/Legrand complete all as Specified and directed.
S & F MCB SPN 230 volts suitable for fixing on MCB DB of capacity 40 Amps complete all as specified. Make -L&T/Schneider/Seimens/Legrand complete all as Specified and directed.
S & F MCB SP, 240 volts, 6-32A Amps 50 Hz ,confirms to IS/IEC 60898 Breaking Capacity of 10 kA, B-curve, complete all as specified and directed. Make -L&T/ Schinder/ Legrand/ Seimens.
Supply and fixing LED Tube Light Batten fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F in replacement decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base made out of polycarbonate with unbreakable globe/frame suitable for LED bulb and provision of LED bulb 09 watts complete incl removal of old unsv fitting all as specified and as directed. Model No. LHFOECE1TZ1O014 of Havells or Equivalent in Crompton /Philps / Surya
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape duly fixed with Clamps nuts and bolts complete all as directed by Engineer-in-Charge. Make- Havells Cat Part No. LHEXAYP7PN6K020 or equivalent in /CG/Surya / Philips
Excavation in trenches n exc 1.50 m wide and n exc 1.50 m depth in soft /loose soil and getting out for lying of cable and errection pipe etc complete all as directed.
Returning, filling in, trenches in soft /loose soil including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed.
Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed.
M & L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed.
Supply & Laying well burnt brick , locally available best quality (sub class "B" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified.
Supply & Laying XLPE LT heavy duty UG Cable of size 35 Sqmm 3.5 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed.
Supply & Laying XLPE LT heavy duty UG Cable of size 16 Sqmm 2.0 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed.
S & F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed.
Taking down ceiling fan/ Exhaust Fan of any sweep, keeping with safe custody and refixing the same with replacement of unsv core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal over hauling the fan duly painted with two coats of synthetic enamel paint complete all as specified and as directed.
M&L for replacement Sub main wiring 2 x 4.0 Sqmm multi-strand FRLSH PVC insulated copper conductor unsheathed cable including concealed conduit and continuous earth wire of FRLSH PVC insulated multi-strand copper conductor of size 4.0 sqmm complete all as specified and directed. Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles complete all as Specified and directed.
M&L for replacement Sub main wiring 2 x 6 Sqmm multi-strand FRLSH PVC insulated copper conductor unsheathed cable including concealed conduit and continuous earth wire of FRLSH PVC insulated multi-strand copper conductor of size 6.0 sqmm complete all as specified and directed. Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles complete all as Specified and directed.
Material and Labour for AC Socket with MCB DP 25 Amps , starter switch and Socket with Plug Top and indicator complete complete all as specified and directed.
Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item complete all as Specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, check nuts and washers including excavation earth work provisioning of PCC chamber made of PCC 1:3:6 RCC cover funnel with wiremesh 20mm dia watering pipe Medium grade, GI protection pipe 20mm dia bore all as specified in Electrical Plate No.3 of SSR Part I.
Supply and Fix Cable end termination kit for LT 1.1 KV Cable for Cable 25 /3.5 Core cable complete all as specified and directed .
Supply and Fix Cable end termination kit for LT 1.1 KV Cable for Cable 10-16 /2 Core cable complete all as specified and directed .
S&F in replacement Octane LED 2X2 PANEL ultra slim recess mounted edgelit LED 36Watt module with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling complete incl removal of old unsv fitting all as specified and as directed. Make Havells or Equivalent in Crompton /Philps / Surya
M&L in replacement for earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to Copper strips 20X3 mm by means of copper nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed. NOTES : The unit rate includes for protection pipe and Copper strip from top of earth plate up to 7.00 meter above ground level.
S&F in repair air termination, single pointed copper rod, 12 mm dia and 600 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
S&F Epoxy electrical insulator(heavy duty) for fixing of Copper/Aluminium Strip/GI wire complete all as specified and directed.
S& F in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over epoxy electrical insulators or any other indicated situation for loop earthing etc as required with 20 x 3mm copper strip duly brazed complete all as specified and directed.
Supply and Fix Aluminium strip 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and over roof over porcelein insulators complete all as specified and directed
S & F in replacement Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw in a test point box complete all as specified and as directed.
S&F in replacement GI Pipe of 32 mm Dia, ISI Marked , light grade to cover the earth strip complete all as Specified and directed.
Supply and Fix in replacement Thermoplastic Cable Junction Boxes IP66/67 "weather proof" , for outdoor installation without mounting plate with Transparent Lid of Size 217 X 253 X 115 mm for mounting of Test Point and including Necessary civil works and complete all as specified and directed by Engr-in-Charge. Make Cat No. KG9003 of Hensel or equivalent in sintex
M/S K.K.TRADERS (BID ID -3318564)
Markson (BID ID -3318585)
M/S RANA ENGINEERING ENTERPRISE (BID ID -3318716)
S M STORE (BID ID -3318362)
M.P.SUPPLY (BID ID -3318900)
M/S L R ENTERPRISE (BID ID -3319389)
R K ENGINEERING ASSEMBLE (BID ID -3319676)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .