Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹4.9 L+₹34,610 (7.59%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹5.2 L+₹64,811 (14.2%)Rejected-AOC 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹5.4 L+₹85,150 (18.7%)Rejected-AOC | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹6.7 L+₹2.1 L (46.6%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹8.0 L
EMD Value
₹16,000
Closing Date
15 Jan 2020, 6:00 pmClosed
GE I RNDDEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ REPLACEMENT OF AC, REFRIGERATION, WATER COOLER AND GEYSERS AT DEAL UNDER GE (I) RND DEHRADUN
2019_MES_309168_1
GE(I)RND/8971/E8/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEHRADUN
Class E Category b(i)
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹16,000
Yes
15 Feb 2020
24 Dec 2019
17 Jan 2020
24 Dec 2019
15 Jan 2020
31 Dec 2019
24 Dec 2019 - 31 Dec 2019
Amount
Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, painting the bottom with one coat of black synthetic enameled paint, brazing, reassembling and testing of the AC complete all as specified and directed
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed. NOTE :- (Applicable for Sch ‘A’ Item No. 1 &2) (i) Window / Split ACs / Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis. (ii) Window/ Split ACs are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window / Split ACs / Water cooler / Refrigerator /Deep Freezer in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (iv) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’. (v) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : Carrier /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 1.5 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : Carrier /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : Carrier /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for window type AC of any type/ any capacity complet, all as specified and directed by Engr-in-charge. (Make : Carrier /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for Split type AC of any type/ any capacity complet, all as specified and directed by Engr-in-charge. (Make : Carrier COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for Window type AC 1.5 ton/2.0 ton capacity 1/5 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge.
Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge.
M&L for replacement of for cooling coil unit for window/Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge.
M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).
Disconnecting and taking out defective / nonfunctional capacitor and Supply & fixing running capacitor 45 Mfd complete all as specified and directed . (Make : Syscap / Asian/ JYOTI/KELTRON )
Disconnecting and taking out defective / nonfunctional capacitor and Supply & fixing starting capacitor 80/100 Mfd, 240 Volts suitable for 1.5 TR/2TR AC complete all as specified and directed. (Make : Syscap / Asian/ JYOTI/KELTRON/
Disconnecting and taking out defective / nonfunctional capacitor and Supply & fixing starting capacitor 100/120 Mfd, 240 Volts suitable for 1.5 TR/2TR AC complete all as specified and directed. (Make : Syscap / Asian/ JYOTI/KELTRON/
Disconnecting and taking out defective / nonfunctional capacitor and Supply & fixing running capacitor 36 Mfd suitable complete all as specified and directed. (Make : Syscap / Asian/ JYOTI/KELTRON )
Disconnecting and taking out defective / nonfunctional capacitor and Supply & fixing running capacitor 25 Mfd complete all as specified and directed. (Make : Syscap / Asian/ JYOTI/KELTRON )
Disconnecting and taking out defective / nonfunctional thermostat switch and Supply & fixing Thermo stat Switch with Knob 230 Volts suitable for window AC 1.5 TR/2TR complete all as specified and directed. (Make : Indfos/AnnaPurna/Ranutrol)/Daspass)
Disconnecting and taking out defective / nonfunctional relay and Supply & fixing thermal over load relay 20 to 30 Amp capacity suitable for 1.5 TR/2TR capacity AC complete all as specified and directed (Make : L&T/BCH)
Disconnecting and taking out defective / nonfunctional PVC knob and Supply & fixing Chromium plated PVC Knob any type any size suitable for window AC 1.5 TR capacity complete all as specified and directed (Make : Blue Star/ Voltas / Carrier/LG/Videocon)
Disconnecting and taking out defective / nonfunctional PVC grill and Supply & fixing PVC grill any type/any size suitable for window type AC 1.5 TR/2TR capacity complete all as specified and directed (Make : Voltas / Blue Star / Carrier/LG/Videocon/Usha/Feeder Lloyd )
Disconnecting and taking out defective / nonfunctional relay and Supply & fixing potential type relay 1622 for window/Split type AC 1.5 to 2 TR cap. complete all as specified & directed (Make : L&T/BCH)
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for window type/Split A/C complete all as specified and directed. Make – Athlete / John Flower
Disconnecting and taking out existing defective / unserviceable remote control assembly with PCB of any description and in any position of any type of split AC & Supplying & fixing new remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG )
Disconnecting and taking out existing defective reverse cycle valve and Supply & fixing reverse cycle valve in window type AC of 1.5 / 2 TR cap. and welding, brazing including copper tubing of proper size and charging of Gas R-22 and testing complete all as specified and directed. Make : Renutrol/Pacific
Supply & charging of refrigerant Gas R-410 a to make up the required pressure complete all as specified and directed.
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed.
Disconnecting and taking out existing defective cable and Supply & fixing PVC insulated and sheathed cable 3 core 2.5 sqmm stranded copper conductor complete all as specified and directed. Make :-PLAZA/ FINOLEX/HAVELLS /POLYCAB/SHALABH/NATIONAL
Disconnecting and taking out burnt / non functional metal clad plug top and socket and supply and fixing new metal clad plug and top 3 pin, 20 Amp capacity complete all as specified and directed. Make : Standard / Havells / C & S Electrics/ Siemens
Disconnecting, dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 3 to 5 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. NOTE :-The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’
Supply & fixing transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 5 KVA of approved make complete all as specified and directed. .
All as per Item No 31 here in above but of capacity 4 KVA complete all as specified and directed.
Supply & fixing relay 12/24 volts suitable for 4 -5 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make complete all as specified and directed.
Supply & fixing electromechanical type voltmeter 0 to 300 volts Single Phase , AC, 65 mm square/round for stabilizer as per requirement complete all as specified & directed. Make – AE or equivalent approved.
Supply & fixing DC electronic circuit for relay of capacity 24/12 volts stabilizer for 4 to 5 KVA of approved make complete all as specified & directed.
Supply & fixing 3 way connector 230 volts 50 Hz AC, 32 Amp of approved make & existing shape and size complete all as specified and directed.
Supply & fixing toggle switch 20/30 Amp two way of approved make complete all as specified and directed.
Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position, capacity 40 ltr to 150 ltr, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, checking serviceable parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed. NOTE :-The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’.
Disconnecting and taking out existing defective tap and Supply & fixing CP brass Push cock, 15 mm. Dia (ISI marked) inner/outer threaded complete all as specified and directed
M&L for painting of existing water coolers of any description and any position and capacity with applying one coat of synthetic enameled paint (white) by spray machine including preparation of existing decorated surface of water coolers including writing MES No/ SM No in capital letters of height not less than 20 mm on water cooler body in MES pattern complete all as specified and directed.
M & L for preparation of the steel surfaces of desert cooler and applying one coat of synthetic enameled paint on all exterior surfaces and applying one coat of black bituminous paint on all interior surfaces including bottom surfaces and writing MES No of the desert cooler in the pattern as approved by the Engineer-in-Charge with different tint / colour complete all as specified and directed.
Supply & fixing PVC distributor 3 way, suitable for 15mm dia water distribution complete all as specified and directed.
Supply & fixing PVC insulated and sheathed cable 3 core 1.5 sqmm stranded copper conductor round 1100 volt grade as in connection to desert coolers/geysers/water coolers complete all as specified and directed Make :-PLAZA/ FINOLEX/HAVELLS/POLYCAB/ SHALABH/NATIONAL
Supply & fixing new wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.
Supply & fixing,inreplacement of UNSV Vertical Pump, 230 volts, 45 watt, 1400 RPM, with ball bearings complete all as specified and directed (Make : Crompton / AUE / Khaitan/ Bajaj )
Disconnecting and taking out burnt / non functional plug top and supply and fixing 3 pin, 15/16 Amp capacity complete all as specified and directed. Make : Anchor (Penta deluxe) or equivalent as approved by GE.
Disconnecting and taking down the existing Geyser of any description and any capacity (25 / 50 Ltrs) and any position from the existing location and Dismantling the Geyser of any capacity and of any description material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , ‘U’ assembly etc. with brush, cleaning rod, and using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately
S&F fill glass wool for geysers including taking down old glass wool complete all as specified & directed.
Taking down of old unserviceable thermal cut out & S&F thermal cutout unit as per existing type complete all as specified & directed..
Taking down old unserviceable sypohon assembly & S&F sypohon assembly as per existing model/shape made out of chromium plated brass suitable for 25 Ltr capacity geyser complete all as specified and directed.
All as per item No. 50 here in before but suitable for 50 Ltr capacity geyser complete all as specified and directed by Engr in-charge.
Taking out old unserviceable rubber gasket any type complete & S&F rubber gasket round in shape 8 to 9 holes suitable for 25/50 Liter capacity geyser complete all as specified and directed.
Taking out old unserviceable inner tank & S&F inner shell as per existing type/size/shape suitable for 25 Ltr capacity geyser made out of cooper complete all as specified and directed.
Taking out old unserviceable inner tank & S&F inner shell as per existing type/size/shape suitable for 50 Ltr capacity geyser made out of cooper complete all as specified and directed..
S&F stop valve cast copper alloy, chromium plated screwed down, high pressure, with crutch or butterfly handle screwed both end cock 15mm dia made out of brass complete all as specified and directed.
M&L for Painting of geysers size 25 liter any make with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/rust and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2 mm width letter on geyser body with black enameled paint complete all as specified and directed.
M&L for Painting of geysers size 50 litre any make with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/rust and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2 mm width letter on geyser body with black enameled paint complete all as specified and directed.
Disconnecting & taking out defective existing ‘U’ assembly of 25 Ltr cap any description and in any position from Geyser and supply and fixing new ‘U” assembly to match with the existing system complete all as specified and directed. Make – Recold / Bajaj,/ Daspass
Disconnecting & taking out defective existing ‘U’ assembly of 50 Ltr cap any description and in any position from Geyser and supply and fixing new ‘U” assembly to match with the existing system complete all as specified and directed. Make – Recold / Bajaj,/ Daspass
Disconnecting & taking out defective Thermostat and supply and fixing new Thermostat with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Disconnecting & taking out defective Fusible plug/safety valve supply and fixing new Fusible plug/safety valve as per sample ISI marked having melting point 90°C to 95°C complete all as specified and directed
Taking down old bottom plate of geysers 25/50 liters capacity & supply & fix new bottom plates of same sizes and shape complete all as specified & directed.
Supply & fix new air release valve 15 mm bore for geyser as per existing type including taking down old unserviceable air release valve’s complete all as specified and directed.
Disconnecting & taking out defective Geyser element and supply and fixing new Geyser element of 1500 Watt, 230 volts, complete all as specified and directed Make - Dasspass or equivalent make as approved by GE.
Disconnecting & taking out defective Geyser element and supply and fixing new Geyser element of 2000 Watt, 230 volts, complete all as specified and directed Make - Dasspass or equivalent make as approved by GE.
Disconnecting & taking out defective Indicating lamp and supply & fixing Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
Disconnecting and taking up/down existing unserviceable PVC connection and supply and fixing new PVC connection 15 mm dia 450 mm long having brass nut and washer on both end suitable for Hot/Cold water complete all as specified & directed. Make - Prayag or equivalent make as approved by GE.
Taking out defective sealed unit compressor of water cooler of capacity 40 Litre/Hrs of any make and transportation to company for repair and thereafter fixing back the repaired compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure for leakage & testing with charging of Refrigerant Gas and testing & commissioning of water cooler complete all as specified and directed.
Taking out defective sealed unit compressor of water cooler of capacity 80 Litre/Hrs of any make and transportation to company for repair and thereafter fixing back the repaired compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure for leakage & testing with charging of Refrigerant Gas and testing & commissioning of water cooler complete all as specified and directed.
Taking out defective sealed unit compressor of water cooler of capacity 150 Litre/Hrs of any make and transportation to company for repair and thereafter fixing back the repaired compressor of original make in the existing water cooler, including welding, brazing of gas pipe line, vacuum pressure for leakage & testing with charging of Refrigerant Gas and testing & commissioning of AC complete all as specified and directed. (Note for item No. 73 & 74:- Refrigerant Gas required for charging of compressor shall be measured separately under respective item of this Schedule.)
Disconnecting and taking out old rusted angle iron, MS sheet etc. from rusted and perished body and frame of water cooler/ refrigerator and supply and fixing new MS sheet and angle iron frames etc. using ordinary quality of steel complete including welding and grinding etc. complete all as specified and directed.
Supply and fixing in replacement stainless steel plate with water drainage tray of water cooler of any capacity and of make as approved by GE. complete all as specified and directed
Supply and fixing in replacing refrigerant copper tubing 3/8" with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete.
Supply and fixing in replacing refrigerant copper tubing 1/4" with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete.
Supply and fixing in replacment foam type insulation sleeve for copper tubing 1/4", binding and securing the insulation firmly with copper tubing as per site requirement complete.
Supply and fixing in replacment foam type insulation sleeve for copper tubing 1/2", binding and securing the insulation firmly with copper tubing as per site requirement complete.
M&L for earthing complete for bldg/poles with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed . NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover
MAHADEV ELECTRICALS
Tarachand gurudutt
NAVEEN ENGINEERS AND CONSULTANTS
Bedi Refrigeration Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .