| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 LAccepted-AOC KALARICKAL H ELAMBRA | KOTTAYAM | KERALA | 686001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.7 L+₹18,155.20 (11.7%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹1.8 L+₹21,480.83 (13.9%)Rejected-AOC VARAMBATHUKUDIYIL BLDG NELLIKUZHY P O KOTHAMANGALAM 686 691 | KOTHAMANGALAM | ERNAKULAM | KERALA | 686691 | 3 | Rejected-AOC L2 |
Tender Value
₹1.8 L
EMD Value
₹4,408
Closing Date
30 Oct 2024, 5:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer LSGD Subdivision Kothamangalam
Pachira DWS Construction of Pachira Drinking Water Scheme Construction of Well, Motor pump pipeline Electrification Electrical Work
2024_LSGD_693859_2
PachiraDWS
Open Tender
Electrical Works
Item Rate
240 days
Pachira
Please refer Tender documents.
5 documents required · 5 mandatory
₹555
₹4,408
2 Dec 2024
23 Oct 2024
1 Nov 2024
23 Oct 2024
30 Oct 2024
23 Oct 2024
23 Oct 2024 - 30 Oct 2024
Amount
Providing Pump Set -
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD235956/2023-2024:Supply, conveyance, installation, testing and commissioning of Bulk head light fittings with 7/9 W LED bulb directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS making good the damages, colour washing etc as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD77753/2024-2025:Supply, conveyance, installation, testing and commissioning of 5 HP , 4 stage Open well Submersible motor pump set of pipe size 50 mm having a head range of 34 to 77 mtr with a discharge of 275 to 75 Lpm working suitable for three phase , 440V, 50 Hz AC supply and giving connections and trail run on full load. .( model DECCAN- 5DQM/4 , Kirloskar / Texmo or equivalent make etc as required )
OD235958/2023-2024:Supply and providing BCH make Star Delta Starter control with protection against overload, single phasing, phase reversal & severe unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1 specifications suitable for 5 HP submersible motor pump set complete duly internally connected
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
OD235959/2023-2024:Supply and providing Cable Joint Tape etc. as required.
OD235960/2023-2024:Supply and Providing 50 mm or nearest size UPVC Adaptor Set DC CI with accessories etc
OD235961/2023-2024:Supply and fixing 50mmx 12" GI Barrel nipple
OD235962/2023-2024:Supply and fitting 50 mm or nearest size GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
OD235963/2023-2024:Supply and fitting 50 mm or nearest size Sluice valve on existing GI pipe with flanges etc
OD235964/2023-2024:Supply and fitting 50 mm or nearest size Non Return valve using required bolt and nut and flange etc
OD235965/2023-2024:Supply and providing clamp set CI 50mm Heavy
OD235966/2023-2024:Supply and fixing 25mm Ball Valve with 15mm nipple and 15mm socket duly welded as required
OD235967/2023-2024:S&I of Pressure meter with accessories and stopper valve etc on delivery side of 50 mm GI pipe line as required
OD235968/2023-2024:Supply and fitting 50 mm GI socket etc. as required.
OD235969/2023-2024:Supply and Providing 50 mm GI pipe (Medium class) Cutting threading welding and with accessaries etc
OD235970/2023-2024:Supply and provide NYLON ROPE MAXIMA LG 12MM or nearest size for hanging submersible pump set
OD235971/2023-2024:Supply and providing Cotton waste etc. as required.
OD235972/2023-2024:Supply and providing Shellac 50 ml etc. as required.
OD235973/2023-2024:Supply and fixing 20mm corrugated flexible pvc conduit
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD235974/2023-2024:Supply and providing 25x3mm brass nut and bolt etc. as required.
OD235975/2023-2024:Supply and fixing 63 A 415 V , 2 way neutral link mounted on DMC / SMC base in the existing meter board and giving connection etc.
OD235976/2023-2024:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
OD235977/2023-2024:Supply and Installation of dust and vermin proof , wall mounting , Sintex 3 Phase meter box of size 650x350x250 mm suitable for fixing KSEB meter ,fuse units etc, hinged door connection for the front side with compartments if necessary , providing vision panel for the meter component , knock out for cable entry and exit.( GSMB?6535 )
OD77837/2024-2025:Supply and providing iron hook for binding service wire
ALIYAR T K
SK ELECTRICAL
Bidder Name
ALIYAR T K
K R ASOKAN
SK ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1090310.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .